Document pmYyQ1B5E5yr9Z1xOvY1MXb77

suaniuxiMi .uxiuoid -- 1 3/ SGP 0023636 1976 SGP 0023637 DT Document Index ............... 2 MR Manufacturer Testing Facilities............................. 4 UA Uses, Applications, Limitations ......................... 4 PP Product Presentation......... 5 OP Overall Production Place . . 6-27 Al Construction, Assembly, Installation .......................... 14-27 MF Materials, Finishes ............ 28-34 CS Coatings, Surfaces ............ 28-34 TC Technical Support............. 35 CC Code Acceptability, Certification ....................... 35 SGP 0023638 2 GeorgiaFScific TESTING AND RESEARCH FACILITIES Georgia-Pacific's Gypsum Product Development and Technical Service laboratory is located at Tigard, Oregon, This is where new products such as Predec gypsum paneling, tile backer board, sound deadening board, SentinelTM board, Denscote, Denscal and Densite plasters, and Firestop* gypsum board had their beginnings. The G-P family of joint system products, the G-P sound comrol systems and the G-P fire rated systems, including the shaft wall systems, were also developed here. The increase in multi family living has made fire safety and sound privacy of utmost importance. The technical personnel at the Gypsum Lab also deal with quality and produc tion problems. The effort to offer reliable products at the lowest possible cost is a never-endirg task. Georgia-Pacific must be technically competent in these continually changing times in orderto be able to furnish the products required by the construction industry. 3 SGP 0023639 MINING AND MANUFACTURING GYPSUM AND GYPSUM PRODUCTS Georgia-Pacific interior gypsumboards are non-load bearing panels. Regular Gypsumboard panels are not recommended for use under extremely moist conditions. G-P Tile Backer Board is to be used in bathrooms or other high moisture areas. V*" gypsumboard should only be used as an application over existing walls or as the first layer in a sound rated system. Because of the limita tions of manufacturing equipment, the maximum length available in gypsum board is 16 feet. 4 SGP 0023640 GeorgiaF&cific GEORGIA-PACIFIC THE COMPANY Georgia-Pacific began its history distributing lumber domestically and abroad from the South, then en tered the fields of plywood manufacture and timber ownership and management. It believed in inte grated manufacturing and each phase of using a tree's residue produced something new ... lumber hardboard, particleboard, pulp, paper (fine papers, working papers, containers, tissues, food board, etc.), chemicals from paper residues, chemicals to help make wood products, chemicals for broad market sales, new kinds of plywood, recycling of wood and chemical materials, development of new and better trees, better timber management methods. Other resources include ... gypsum (gyp-.urn products), natural gas, metallurgical and other coal, oil, silica, ceramic clays and many other minerals. G-P is also a nationwide distribution system in every major market in the United States and Canada, and a transportation company with fleets of trucks and railcars to ensure good service with good products. Georgia-Pacific owns timber throughout the U S. and in Brazil and Canada; timber rights in Indonesia and the Republic of the Philippines. It also manu factures wood products in Brazil, the Philippines and Indonesia selling to both Asia and America G-P is a highly decentralized company with over 34,000 employees working in 47 states, the District of Columbia and several foreign countries. Georgia-Pacific .., The Growth Company. 5 SGP 0023641 GYPSUM BOARD NAILS & SCREWS SELECTOR GUIDE b b * o HlPMibMriit rat rfw- - n --t * Oypeeai board to Wood DttorfptJM Applications 1 V* ' GWB-54 Annular Rina Nail 12ft ga.; with a slight taper to a small fillet at shank. Bright finish: med. diamond pt. to', to' and to' Gypsum board, to' and to' Gypsum Backer Board to wood frame 1ft" Annular Ring Nail (Same as GWB-54 except for length) ft" Gypsum board to wood frame 2%' 7d naif 13 ga., V* * diamond head to' Firestop Gypsum board face layers over to' Sound Deadening Board or 2 layers to* Firestop to Wood Studs 1%' Qd Nail 13 ga.. V* " diamond head to' and to' Gypsum board over existing surface, wood frame 1ft* 6d Naif 13 ga., to * diamond head to* Firestop Gypsum board to wood frame to* 5d Nail I3to ga., diamond head 1ft' Matching Color Head Nail (Steel) 1ft' Matching Color Head Nail (Steel) to' Firestop Gypsum board to wood frame Predecorated Gypsum board to wood frame over existing surface, wood frame 1 ft * Matching Color Head Nall (Brass) Predecorated Gypsum board (colors) to wood frame 1' Gypsum board Screw Type S Single Layer Gypsum board to 25 Gauge Steel Studs. Gypaum board to Resilient Channel. Gypsum board to Metal Purring. 1to" Gypaum board Screw Type S 19b' Gypsum board Screw Type S 1' core unite to L Runner in 2' Solid and Semi-Solid Partition Systems 1ft* Gypsum board Screw Type S Double-Layer Gypsum board to 25 gauge Steel Studs. Double-Layer Gypsum board to Metal Furnng. 1 ft ' Gypsum board Screw Double-Layer Gypsum board Type S 1 ' Gypsum board Screw Type S-12 Also available in ft', 1ft' and 1M" lengths For single or multi-layer application of Gypsum board to heavy gauge steel (up to 12 gauge). 1% 'Gypsum board Screw Single Layer Gypsum board Type W to Wood Framing. aGryopawua dbiobaord lo 1 ft * Gypsum board Screw Type G 1ft* Gypsum board Screw Type G Gypsum board to Gypsum Ribs in Seml-Solld Partition Systems. Wood Trial to Metal Traoilaa 1ft' Gypaum board Screw Type S Trim Head 2ft' Gypaum board Screw Type S Trim Head Wood trim over single layer of Gypsum board on 25 gauge Steel Studs. Wood trim over double layer Gypsum board on 25 gauge Steel Studs. Motal tbrdi to Door PraaMa and Raanora ft' Gypsum board Screw S-12 Pan-Head Metal Door frame to 12 gauge (max.) Steel Studs. Metal Studs to Metal Runners. ^IMVolBt^aHllaTIIllbIPaim,MDRoa|or Hlngaa ft' Type S-18 Oval Head Also available in ft', 1ft' & 1' lengths Door hinges to doorframe and aluminum components to metal. Horizontal and Vortical Application: TYPE S--Motal stud* or furring spacad 24' on contar. Screws should be spaced 12' on center unless otherwise noted in the detailed assemblies shown in Georgia-Pacific literature. TYPE Q--Laminated systems and other gypsum to gypsum applications. TYPE W--Wood studs 16" or 24" on center. Screws should t>e spaced 12' on cantor unless otherwise noted in the detailed assemblies Shown in G-P literature. Selection of the proper nail for each application Is extremely important, par ticularly for fire-rated construction. The nails recommended comply with per formance standards adopted by the Gypsum Association G-P GYPSUM BOARD OR DENS-COTE VENEER PLASTER SYSTEMS. The following tables are summaries only, based on tests at Underwriters' Lab., National Bureau of Stan dards, Univ. of Calif., Ohio State Univ., Geiger and " Hamme, Riverbank Lab. and/or Ohio Research Corp sponsored by the G-P Gypsum Division, Gypsum Association, or others. Fire rating, weight, and sound characteristics are based on a combination of spe cific details as tested and published. Where carpet and pad is used in sound tests, carpet is 44 oz. and pad 40 oz. weights. All systems are ranked by STC number in each category. Fire tests conducted according to ASTM El 19. Sound tests conducted according to ASTM E90. COST INDEX BASIS: For wood and gypsum parti tions, 100 is for 2x4 studs, 16" o.c., Vz" Regular Gypsum board each side. For metal stud partitions, 100 is for 2Vz" studs, 24" o.c., Vs" Firestop each side. Other assemblies are rated against those two. Allow for local differences in labor and material costs. FIRE HAZARD (FLAME SPREAD) CLASSIFICA TION: Official Underwriters' Tests. Vz" and Va" Firestop, 10-15 (Labeled); Vi"and W G-P, 10-15 (Not Labeled). More complete listings and details are available. Tests conducted according to ASTM E84. Inconsistencies in test results are due to tests over a period of many years and variations in laboratory facilities. 1. STC under sound characteristics is Sound Transmission Class. 2. Official Underwriters' Tests have proven joint finishing is not required for the rating in assem blies of Firestop under certain conditions. 3. Under "Building Code Approvals" (A) refers to International Conference of Building Officials; (B) refers to Southern Building Code Congress; (C) refers to Building Officials Conference of America. Additional approvals requested. Check with local building officials for verification of approvals as may be required. 4. Not all code jurisdictions belong to Model Code Groups. Therefore, we advise consultation with local building officials if acceptance of these test results are in doubt. Combustible Assemblies--For all 45 minute and 1 hour ratings W structural interior plywood or particleboard underlayment grade, over building paper, over Vz" structural interior plywood with ex terior glue CD grade may be used over the wood joists with ceilings as detailed. Noncombustible Assemblies--Ceilings for all 1 hour, 1 Vz hour and 2 hour incombustible floor and ceiling construction assemblies with 2" or 2Vz" con crete floor on metal lath over steel bar joints, unless otherwise specified, may be directly attached or suspended. Firestop is listed by Underwriters for U.S.A. and Canada and carries the UL Label for 45 minutes, 1, 2 and 3 hour Fire Resistance in various designs and with a Fire Hazard Classification of Flame spread 15, fuel contributed 15, smoke developed 0. SOUND CHARACTERISTICS--References: Geiger and Hamme, Inc.; Riverbank Labs; Kodaras. More complete listings and details are available. Inconsistencies in test results are due to tests over a period of many years and variations in laboratory facilities. All sound rated assemblies require caufking top and bottom, and other locations where sound leaks may develop. SGP 0023642 6 TECHNICAL DATA WALLS AND COLUMN CONSTRUCTION G-P GYPSUM BOARD OR DENS-COTEVENEER PLASTER SYSTEM G-P 8yL # Fir* Resist. Ratine Taat Rsfar. Sound Tran*. STC Taat Rafar. Coat Index Part Weight Thick par ness Sq. FL Georgia-Fbcific & Construction Wall Surface References Bldg. Detail Cod* Info App Pag* WOOD PARTITIONS (STUDS--2 x 4,16" O.C.) 080 20 min. EST 31 EST 90 4y4" 5.2 e" Gypsum board Both Sides 082 30 min. EST 32 EST 100 4 Va" 5.9 Va" G-P Gypsum board Both Sides 084 45 min. U. 317 32 EST 110 AVa" 5.9 Va" Firestop Both Sides 086 1 hr. U. 305 34 OR-64-8 115 W*' 7.0 5/a" Firestop* Both Sides (U.L. 5) Basic 1 Hr. Fire Rated Wall 087 1 hr. U. 305 34 OR-64-8 125 4%' 7.0 G-P Tile Backer Board (U.L. 5) Both Sides 092 1 Va hr. EST 37 CR-64-11 135 SVa" 9.5 %' Firestop, 1 Layer, One Side, 2 Layers Other Side 094 1 hr. G.A. 38 EST 135 4%' 8.2 %" G-P Gypsum board, 2 Layers, Both Sides 096 1 Va hr. GA 39 NBS 140 5%' 9.9 Va" G-P Gypsum board, 2 Layers, Both Sides 098 2 hrs. T-194 41 OR-64-12 160 5%" 12.0 %" Firestop, 2 Layers, Both Sides ---- ABC -- BC -- ABC 14 ABC -- ---- A-- C-- ABC 14 WOOD PARTITIONS/GYPSUM SOUND DEADENING BOARD (STUDS--2 x 4,16' O.C.) 100 1 hr. U. 312 (U.L. 30) 45 BW-27-FT 145 4V" 7.96 Va * Firestop, 1 Layer Strip Laminated Over Vi' Gypsum Sound Deadening Board, 2 Sides ABC 14 102 1 hr. U. 312 47 BW-28-ST 160 5'A' 8.3 (U.L. 30) Ya" Firestop, 1 Layer Laminated over V * Gypsum Sound Deadening Board, Both Sides ABC 15 104 1 hr. Va" Firestop, 1 Layer over V*." Sound EST 47 BW-29-ST 175 6Va" 8.79 Deadening Board, Both Sides Laminated, -- -- Staggered Studs 106 1 hr. U. 312 50 BW-35-ST 175 5V" 8.7 (U.L. 30) %* Firestop, 1 Layer Strip Laminated over Vi' Gypsum Sound Deadening Board, 2 Sides, 2" Insulation ABC 15 105 1 hr. Va" Firestop, 1 Layer over V*" Gypsum EST 52 BW-30-ST 190 67/e" 8.92 Sound Deadening Board, 2 Sides, 2" Insulation, Staggered Studs ---- See Page 6 for Notes *Firestop is a registered trademark of Georgia-Pacific Corporation. SGP 0023643 7 Q-P y*t # FlmRcrtrt. Tort* -- Rafar. Sound Trans. STC Tort Rafar. Cort Index Part Weight Thick- P*r naaa SC. Ft Construction Wall Surface WOOD STUDS/RESILIENT CHANNELS 112 1 hr. T-3127 44 OR-64-7 135 5Vs" 6.3 Vs" Firestop* 1 Layer Nailed 1 Side, 1 Layer on Resilient furring other side 114 IVi hr. EST 48 OR-64-15 155 5*' 8.8 Vs" Firestop, 2 Layer 1 Side, 1 Layer on Resilient furring other side References Bldg. Code App Detail Info P9 ABC 16 -- 16 WOOD STUDS/RESIUENT CHANNELS/INSULATING BLANKETS y8' Firestop, 1 Layer Nailed 1 Side, 116 1 hr. T-3127 50 OR-64-16 150 5Vs" 6.4 1-Layer on Resilient furring other side, plus fiberglass insulation in stud space ABC 16 STAGGERED STUD WALLS 150 1 Vt hr. EST 43 EST 175 7%' 11.0 Vi ' G-P Regular, 2 layers, Both Sides 152 2 hrs. EST 47 TL-69-210 190 evs' 12.7 Vs" Firestop, 2 layers, Both Sides ---- ABC -- Based on 154 1 hr. U. 305 48 (U.L. 5) - EST 140 6%" 7.0 Vs" Firestop, 1 layer each side, 2x6 plate, 2" insulation ABC -- DOUBLE WOOD STUDS 106 J hr. Vi" Firestop, 1 Layer Laminated over EST 50 BW-31-ST 225 10' 9.14 V* " Gypsum Sound Deadening Board, Both Sides, Double Studs 109 1 hr. Vi" Firestop, 1 Layer Laminated over EST 55 BW-32-ST 240 10' 9.29 V*" Gypsum Sound Deadening Board, 2 Sides, 2" Insulation, Double Studs 170 1 hr. EST 46 / 175 2J1rs. WP297 FM 57 EST RAL 215 9'A" Vs" Firestop, 1 layer each side double 7.5 row of studs 1" apart on separate 2x4 plates, insulation in stud space -- 11 y2' -- Vi" Firestop Gypsum board, 2 layers face each side of wall, 1 layer attached to each stud inside, with 1" space between inside layers Lot Line Wall ABC -- -- 15 ---- -- 17 WOOD STUDS/FIBER SOUND BOARD 116 1 hr. T-3006 46 OR-64-73 165 5%' 8.5 Vs" Firestop, 1 layer over Vi" Fiber Sound Deadening Board, Both Sides See Page 6 for Notes *Firestop is a registered trademark of Georgia-Pacific Corporation. ABC 17 f( SGP 0023644 8 Georgia-Ffecific in G-P Sy*t Fir* RaaiaL Rating T**t R*l*r. Sound Tran*. STC Taat Rafar. Coat Indax Part Waight Thlck- par naaa Sq.FL Conatruction Wall Surfaca Rafarancaa Bldg. Cod* App EXTERIOR WALLS 500 2 hrs. U302 (U.L. 23) 50 EST -- 5%" -- 5/u" Firestop*2 layers interior; Vi" Gypsum Sheathing, Brick Exterior ABC -- 501 1 hr. U305 (U.L. 5) -- -- 4 %" -- plus -- siding 5/e" Firestop (Interior), %" Firestop Tile Backer or Vs" Firestop Gypsum Sheathing (Exterior) Wood Siding -- SOLID GYPSUM BOARD PARTITIONS (NON-LOADBEARING) 230 2 hrs. G.A. 36 232 2 hrs. G.A. 36 234 2 hrs. EST 37 G.A. G.A. G.A. 90 2" 95 2" 100 2'A" Vi" Firestop, 1 Layer Each Side, 8.1 1" Coreboard, height limit 9 ft. based on L/120, 5 lbs. PSF Vi" G-P Gypsum board, 1 Layer Each 8.1 Side, 1" Laminated Coreboard, height limit 9 ft. based on L/120, 5 lbs. PSF 9.1 W Firestop, 1 Layer Each Side, 1" Coreboard ABC 17 ABC -- ---- DOUBLE SOLID GYPSUM BOARD PARTITIONS (NON-LOADBEARING) 224 2 hrs. U502 35 TFt-57-42 -- 4' (U.L. 7) 222 3 hrs. U501 40 TR-57-43 -- 5' (U.L. 5) 200 2 hrs. T-2575 47 OFt-64-39 -- 6' 13.4 Vi" Firestop, 2 Layers Each Side, 1" Rib Coreboard 13.4 5/s" Firestop, 2 Layers Each Side, 1" Rib Coreboard 13 Vi" G-P Gypsumboard over 1" Coreboard Each Side of 3" air space ABC -- ABC -- ABC 17 TRIPLE SOLID GYPSUM BOARD PARTITIONS 204 3 hrs. EST 51 OR-64-58 -- 6' 202 3 hrs. EST 57 OR-64-59 -- 6" Vi" G-P Gypsum board, 1 Layer over 1" 17 Coreboard both sides of 3" air space with 1' Coreboard Vi "G-P Gypsum board, 1 Layer over 1" . 7 ,, Coreb'd. Each side of 3" air space with 1' 1" Coreb'd centered in air space and fiberglass insulation in space on 1 side ---- -- 18 TRIPLE SOLID GYPSUM BOARD PARTITIONS (NON-LOADBEARING) G-P 1 Vs" core unit plus two face layer 206 2 hrs. T-4958 -- -- -- 2%" 10.5 Vi" G-P regular screw-laminated, track and vertical "T" splines 2 hrs. G-P 1 Ve" core unit, angle runners, 2Vi" 208 Chase T-4991 -- -- -- 73/4' 9.0 metal studs, one facing layer of %" Wall Firestop screwed to studs G-P 1 %" core unit, plus face layer %" 210 1 Vi hr. T-4982 -- -- -- 2Vi " 8.4 Firestop screw-laminated. Track and vertical "T" splines on 24" centers See Page 6 for Notes -- ---- ---- SGP 0023645 9 Mar. Sound Tram. Taat ,TC Coat Part Wstyit Thick- par naaa Sq.FL Construction Wall Surface Rotaianeas Bldg. OataN Coda Into *PP P*9a METAL STUDS/INSULATING BLANKETS 24' O.C. 328 1 hr. j- T-5316 41 OR-86-5 110 3%' Va" Firestop* 1 layer each side, 2 Vi" 4.3 fiberglass insul. in stud space, 2Y2 * studs. 1 CM 300 1 hr. T-2316 44 OR-64-81 115 5.0 Vi' Firestop, plus 2 fiberglass insul. in stud space, 1 Vi' studs Vi" Firestop, 1 layer 1 side, Vi' 316 1 hr. T-4848 48 OR-66-6 125 5V4' 7.0 regular G-P Gypsum board, 2 layers other side (insulatnn in cavity for STC), 3%' studs . ! CO 330 1 hr. T-2316 48 OR-64-80 145 Vi' Firestop, 1 lay* r 1 side, 2 layers 7.2 other side, 2' fibe ilass insul. in stud space, 1 Vi' studs 334 1 hr. EST 48 OR-66-6 130 4* Vi' Firestop, 1 layer 1 side, 2 layers 6.3 other side plus 2' fiberglass insul. in stud space, 2Vi' studs Vi' Firestop, 2 layers each side, STC 310 2hrs. T-3218 48 BW-12-FT 155 *,W 8.0 based on 2' insul. in stud space, 2Vi' studs 318 1V4 hrs. T-3126 50 OR-64-51 150 5V4' Vi" Firestop, 1 layer 1 side, 2 layers .8.0 other side plus 3 fiberglass insul. in stud space, 3 Vi' studs 324 2hrs. T-2557 52 OR-64-50 170 6Vi* 11.1 Vi' Firestop, 2 layers both sides plus 2' fiberglass in stud space, 3Vi* studs '4: METAL 8TUDS/GYPSUM SOUND DEADENING BOARD 24- O.C. 304 1 hr. U410 .5 (U.L 32)) 40 BW-16-FT 130 4' Vi * Firestop, 1 layer, laminated over 7.0 V*' S.D. Board, both sides screw attached, 2Vi' studs 308 1 hr. U410 e (U.L 32)) 50 BW-17-FT 140 4' Vi' Firestop, both sides, 1 layer, , . laminated to V*" S.D. Board, screw attached, 2'fiberglass friction fit in stud space, 2Vi' studs Vi' Firestop, both sides, 1 layer 308 1 hr. U410 (U.L 32)) 54 BW-18-FT 145 4Y2' a . laminated to Vi" S.D. Board, screw 01 attached, 2'fiberglass friction fit in stud y space, 2Vi' studs -- ABC -- ABC -- ABC -- ABC ABC ARr DU . Br 18 18 20 -- -- 20 21 22 19 19 19 METAL STUDS/FIBER SOUND DEADENING BOARD 24- O.C. y 320 1 hr. EST 44 OR-65-10 125 5Vi' 5.8 338 1 hr. EST 49 OR-65-11 135 5%' -- Vi' Firestop, 1 layer 1 side, other side, 1 layer over Vi " fiber S.D. Board, 3Vi' studs Vi' Firestop, 1 layer over Vi' fiber S.D. Board, both sides 3Vi' studs -- 21 ---- STEEL STUD CHASE WALL (144- METAL STUDS 24* O.C.--- x 12--Vi' GYPSUMBOARD SPACERS) 326 1 hr. EST 47 BW-33ST -- 7Vi' 6.7 Vi" Firestop, 1 layer laminated over V*' S.D. Board, both sides 327 1 hr. Vi' Firestop, 1 layer laminated over EST 52 BW-34ST -- 7V4' 6.9 Vi' S.D. Board both sides, plus 2' insul. in stud space See Page 6 for Notes 10 SGP 0023646 Georgia-ffecific ^ G-P Syit # Fir* Radit. Rating T*at R*f*r. Sound Tran*. STC T**t R*f*r. METAL STUD PARTITIONS 24" O.C. Coat Index Part. Weight Thick- per n**a Sq. Ft. Construction Wall Surface R*(*r*nc* Bldg. Cod* App Detail Info Pag* 340 35 min. EST 35 OR-65-2 90 3Vi" -- Va" G-P Gypsum board, 1 layer each side, -- 2 Vi" studs -- 302 1 hr. T-2J16 35 TL-62-72 95 27/e" 5.2 Ye" Firestop, 1 layer each side, 1 ye" studs ABC 18 CO 342 1 hr. T-2898 35 OR-64-65 130 -- ye" Firestop, EternawallTU, 1 layer each side, 2Va" studs ABC -- 344 1 hr. T- '069 39 OR-63-1 100 33A" -- ye" Firestop, 1 layer each side, 2Vi" studs ABC -- 346 1 hr. T-2016 42 OR-63-11 105 4%" 6.0 ye" Firestop, 1 layer each side, 3 ye" studs ABC -- 312 1 Va hr. EST 43 OR-63-2 135 4%" 7.5 ye" Firestop, 1 layer 1 side, 2 layers other side, 2Va" studs -- 20 313 1 Va hr. EST 43 OR-64-32 140 5'/i" 8.0 y" Firestop, 1 layer 1 side, 2 layers other side, 3Ve" studs ---- 314 2 hr. T-2557 46 EST 150 5' 10.4 ye" Firestop, 2 layers, 2 sides, 2 Vi" studs ABC 20 322 2 hr. T-2557 47 OR-64-52 -- 61/#' 11.0 ye" Firestop, 2 layers, 2 sides, 3ye" studs ABC 21 350 2 hr. T-2406 47 EST -- 6Ve' 10.4 ye" Firestop, 2 layers, 2 sides (face layer--Eternawall), 3ye" studs ABC -- STEEL COLUMN FIREPROOFING -- 1 hr. C..A. -- -- 1 hr. EST -- -- 1 Va hr. G.A. -- -- -- -- -- 2 hr. , X520 -- (U.L. 20) -- 2 hr. X517 -- (U.L 8) -- -- -- 3 hr. X513 -- (U.L. 39) -- 3 hr. X509 -- (U.L. 18) -- 4 hr. X501 -- (U.L. 26) -- -- -- See Page 6 for Notes -- -- -- Va " G-P Gypsum board, 2 layers -- -- -- y*" Firestop, 1 layer -- -- -- Vi" G-P Gypsum board, 3 layers -- -- -- Vi" Firestop, 1 layer -- -- -- y*" Firestop, 2 layers -- -- -- Vi" Firestop, 2 layers -- -- -- y*" Firestop, 3 layers -- -- -- y*" Firestop, 4 layers ---- AB -- ---- ---- ABC -- ---- ABC -- ABC -- SGP 0023647 11 SOUND CONTROL AND FIRE RESISTANCE TECHNICAL DATA G-P SyiL Sq. Ft. Sound Haling Rating Taat Rat. Fire Raeiftance Rating Taat Rat.* fldg. Detan od Into *PP- Peg, WOOD JOISTS 1* O.C. FINISHED FLOOR ON ROUGH SUBFLOOR, EXCEPT AS NOTED 400 3/s' G-P Regular, 1 layer nailed -- 401 Va" G-P Regular, 1 layer nailed 11.4 402 Vi" Firestop*, 1 layer applied to metal furring channel 16" o.c. with 1" xS" T. & G. subflooring, 1 layer of resin building paper, and 1" x4" T. &G. finished flooring, or 2 layers plywood -- -- STC47 IIC 39 -- 15 mm. -- -- 25 min. -- TL64-155 1 hr. L502 (UL-33) ABC -- ABC -- ABC 22 403 Vi" Firestop, 1 layer nailed. 404 Ve" Firestop attached to i "silient metal fur ring 24" o.c. with 5/s" plywood subfloor and carpet and pad 405 Vs" Firestop, 1 layer naileu, 1 layer 1" x 6" or plywood subfloor, 1 layer 1" x 4" or plywood finish floor 406 Vs" Firestop, 1 layer attached to 2" x 8" joists 16" o.c. and 2" x4" joists 16" o.c. Vt" plywood subfloor attached to 2" x 8'' joists 16" o.c. with rug and pad, 3" insulation in cavity 11.4 -- -- STC 48/ IIC 68 -- 45 min. U.L. No. 1 L-2243 &4 1 hr. EST. 12.0 STC, 38, IIC 34 (EST.) 1 hr. L501 (U.L. No. 1) -- STC 51 / KAL-224- 1 hr. IIC 79 14 + 15 -- AB ABC AB " -- 23 -- 23 407 Vs" Firestop, 1 layer nailed; 2nd layer s/a" 16.0 Firestop applied to resilient furring channel 24" o.c. between layers -- 408 Ve" Firestop, nailed, 15/s" lightweight concrete -- STC 53/ 5/8" plywood, wood joists, 16" o.c. insulation, IIC 73 resilient furring, carpet and pad 409 Vi" Firestop, 1 layer nailed, 1" x 6" T.&G. or 13.0 plywood subfloor, 1" x 4" or plywood finish floor STC 35 IIC 32 -- 2 hr. L505 ABC -- (U.L. No. 217) L-22427 & 28 1 hr. EST. A-- G.A. 1 hr. L503 ABC -- (U.L. No. 46) 411 Vs" G-P Regular, 2 layers nailed -- 413 Vi" G-P Regular, 2 layers nailed -- 415 Vi" Firestop, 1 layer, laminated and nailed to V*" G-P Gypsum Sound Deadening Board, with floor of CD plywood, Vi" particleboard underlayment, carpet and pad 417 5/s" Firestop, Vfayer laminated and nailed to 'A " G-P Gypsum Sound Deadening Board with floor Vs"-CD plywood, Vi" particleboard under layment, carpet and pad -- -- STC 41/ IIC 75 STC 42/ IIC 75 -- 30 min. -- 1 hr. BW-2MT 1 hr. (EST.) 1 hr. EST. EST. EST. EST. ---- ---- A 22 ABC 420 Vi" Firestop, 1 layer screwed to resilient channel 24" o.c., Va" plywood subfloor with 3/8" particleboard over wood joists 16" o.c., 3" insulation, carpet and pad STC 53/ IIC 72 OC 3-MT 1 hr. FC 181 (FM) 23 422 W Firestop, nailed, 1 Vs" lightweight concrete, Ve' plywood, wood joists 16" o.c., insulation, carpet and pad -- STC 47/ IIC 65 L-22429 & 30 1 hr. EST. A SGP 0023648 12 Georgia-Ffecific G-P 8yst- tt Weight Sq. Ft Sound Rating Rating Tast Rat. Firs Rasistanca Rating Tast Rat.* Bldg. App. Datail Page WOOD JOISTS 24' O.C. 475 Vs" Firestop, 1 layer attached to resilient channel 16" o.c., ***" T.&G. plywood subfloor, glue-nailed, over 2" x 10" joists 24" o.c. -- STC 50 EST. 1 hr. U.L. L513 -- 23 PREFABRICATED FLOOR PANELS SPACED 12' O.C.--COMBUSTIBLE 410 Vi" Firestop, 1 layer over Vi" Sound Deadening Board (direct attached) 6.5 -- -- 1 hr. U.L. No. 47 A -- 2' CONCRETE FLOOR ON METAL LATH OVER STEEL BAR JOISTS 24' O.C.--INCOMBUSTIBLE 421 Vs" Firestop nailed or screwed to metal furring 16" o.c. 34.2 -- -- 1 hr. U.L. No. 2 ABC -- 423 Vs" Firestop Backer, nailed or screwed to metal furring 16' o.c. 34.2 -- -- 1 hr. U.L. No. 2 ABC -- 425 Vs" Firestop, 1 layer, metal furring 24" o.c. 32.0 -- -- 1 hr. G501 ABC -- (U.L. No. 19) 427 Vi" Firestop, metal furring 24" o.c. 33.9 -- -- 1 Vi hr. G502 ABC -- (U.L. No. 17) 429 Vs" Firestop Type XXX,metal furring 24" o.c. 36.4. -- -- 2 hr. G505 ABC -- (U.L. No. 259) 431 Vs'Firestop, metal deck 24" o.c. 37.0 -- -- 2 hr. U.L. File ABC -- R4024-12 2%' CONCRETE FLOOR ON METAL LATH OVER STEEL BAR JOISTS 24' O.C.--INCOMBUSTIBLE 440 y2" Firestop, metal furring 24" o.c. 38.5 -- -- 2 hr. G504 (U.L. No. 237) 442 Vs" Firestop, metal furring 24" o.c. 39.3 -- -- 2 hr. U.L. No. 69 2%' CONCRETE FLOOR ON METAL LATH OVER OPEN WEB STEEL JOISTS 24' O.C.--INCOMBUSTIBLE -- Vi" Firestop, Chicago metallic steel framing 48" o.c. -- 2 hr. G523 ABC -- STEEL-WOOD COMBINATION JOISTS 450. Vs" Firestop, 18" deep combination steelwood joists 32" o.c., 3" insulation, resilient furring, carpet and pad, IVs" plywood subfloor -- 452 Vs" Firestop, 18" deep combination steel- -- wood joists 16" o.c., 3" insulation, Vs" plywood, lightweight concrete deck, carpet and pad STC 47/ INR + 18 STC 46/ INR + 11 L-22435 4 36 L-22437 4 38 1 hr. 1 hr. EST. EST. ---- ---- BEAM PROTECTION -- Vs" Firestop, 2 layers ---- -- 2 hr. N501.N502 -- -- (U.L. No. 254, 255) 'Many of these are new numbers assigned by Underwriters' Laboratories. (Old numbers are in parentheses.) See Page 6 for Notes 13 SGP 0023649 SYSTEM INSTALLATION DETAILS %" FIRESTOP* GYPSUM BOARD 1 LAYER BOTH SIDES (BASIC 1 HR. FIRE RATED WALL) #086 STC/34 SOUND TEST OR-64-8 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L. U305 (U.L 5) Materials Usad 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. Vi ' Gypsum board Firestop %" FIRESTOP' GYPSUM BOARD 2 LAYER 2 SIDES #098 STC/41 SOUND TEST OR-64-12 FIRE RATING/2 HR. COMBUSTIBLE FIRE TEST T-194 Materials Used 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x4" Wood Plates 3. V$" Firestop Type X Gypsum board 4. 6d and 8d Nails Vz" FIRE 1TOP' GYPSUM BOARD LAMINATED TO Va" GYPSUM SOUND DEADENING BOARD #100 STC/45 SOUND TEST G&H BW 27FT FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L. U312 (U.L. 30) Materiala Uaad 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. Vi " Gypsum Sound Deadening Board 4. 'h " Firestop Type XXX Gypsum board or Firestop EternawallTM 5. 5d cc Nails SGP 0023650 14 f to" FIRESTOP* GYPSUM BOARD LAMINATED TO Va" gypsum ) SOUND DEADENING BOARD #102 STC/47 SOUND TEST G&H BW 28FT FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L U312 (U.L 30) Material* Uaad 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates .J. Vi" Gypsum Sound Deadening Board 4 V" Firestop Type X Gypsum board or Firestop Etemawall'" 5. Joint Compound GeorgiaF&cific to" FIRESTOP- GYPSUM BOARD TYPE X, 1 LAYER LAMINATED TO to" S.D.B., 2 SIDES WITH Ito" INSULATION #106 STC/50 SOUND TEST G&H BW 35FT FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L U312 (U.L 30) Material* Uaad 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. %" Gypsum Sound Deadening Board 4. y" Firestop Type X Gypsum board or Firestop EternawallTM Gypsum board 5. Joint Compound 6. 4d Finishing Nails to" FIRESTOP* GYPSUM BOARD LAMINATED TO to" GYPSUM SOUND DEADENING BOARD #105 STC/47 STC/52 WITH INSULATION SOUND TEST G&H BW 29ST/G&H BW 30ST FIRE RATING/1 HR. COMBUSTIBLE/EST. Malarial* Uaad 1. 2" x 4" Wood Studs staggered 8" o.c. on opposite sides of 2" x 6" Wood Plate 2. 2" x 6" Wood Plate 3. y " G-P Gypsum Sound Deadening Board 4. Vi" Firestop Type XXX or Firestop EternawallTM Gypsum board 5. G-P Joint Compound 6. 4d Finishing Nails and 4d Common Nails 7. 5d Common Nails 8. 2" Insulation Batts (on BW-30ST for STC/52) STAPLED INSULATION to" FIRESTOP* GYPSUM BOARD LAMINATED TO Va" GYPSUM SOUND DEADENING BOARD #109 STC/50 STC/55 WITH INSULATION SOUND TEST G&H BW 31ST/G&H BW 32ST FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Used 1. 2" x4" Wood Studs (double row) 16" o.c. 2. 2" x 4" Wood Plates--1" apart 3. y " G-P Gypsum Sound Deadening Board 4. Va" Firestop Type XXX or Firestop EternawallTM Gypsum board 5. 4d Finishing Nails, 4d Nails 6. 5d Nails .7. G-P Joint Compound 8 2" Insulation Batts (on BW 32ST with insulation for STC/55) I 2x4 STAGGERED STUDS 15 SGP 0023651 ft" FIRESTOP' GYPSUM BOARD ON RESILIENT CHANNEL #112 STC/44 SOUND TEST OR-64-7 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST T-3127 Materials Uead 1. 2" x 4" Wood Studs 16' o.c. 2. 2" x 4" Wood Plates 3. %" Firestop Type X Gypsum board 4. Resilient Channels 5. 1V*' Type W Gypsum board Screws ft" FIRESTOP* GYPSUM BOARD 2 LAYERS 1 SIDE/1 LAYER ON RESILIENT CHANNEL OTHER SIDE #114 STC/48 SOUND TEST OR-64-15 FIRE RATING/1 ft HR. COMBUST1BLE/EST. Materials Ussd 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. '"--Firestop Type X Gypsum board 4. Resilient Channels 5. 1 y ' Type W Gypsum board Screws 6. 1" Type S Gypsum board Screws S/r FIRESTOP 2x4 WOOD STUDS RESILIENT METAL FURRING CHANNELS 1/2* GYPSUM FILLER 2x4 WOOO PLATES. FLOOR AND CEILIN' ft" FIRESTOP* GYPSUM BOARD ON RESILIENT CHANNEL WITH INSULATION IN CAVITY #116 STC/50 SOUND TEST OR-64-16 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST T-3127 Material* Used 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. %" Firestop Type X Gypsum board 4. 2" Insulation 5. Resilient Channels 6. 1V* " Type W Gypsum board Screws 7. 1" Type S Gypsum board Screws 2x4 WOOD STUDS RESILIENT CHANNELS 5/8" FIRESTOP 1/r GYPSUM FILIEF 2*4 WOOO PLATES SGP 0023652 16 %" FIRESTOP' GYPSUM BOARD OVER FIBER SOUND DEADENING BOARD 2 SIDES #118 STC/46 SOUND TEST OR-64-73 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST T-3006 Malarial* Uaad 1. 2" x 4" Wood Studs 16" o.c. .2 2" x 4" Wood Plates .3 2" x 4" Wood Fire Blocks 4. Vi " Fiber Sound Deadening Board 5. y" Firestop Type X Gypsum board 6. 5d Cement Coated Nails and 8d Box Nails 7. Laminating or Joint Compound Georgia-ffecific W FIRESTOP' GYPSUM BOARD 1 LAYER EACH SIDE OVER T. & G. COREBOARD #230 STC/36 SOUND TEST G.A. FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST G.A. Malarial* Uaad 1. 1" T. & G. Coreboard, "V" edge 2. Vi" Firestop Gypsum board 3. Metal Track 4. Laminating Adhesive ^ FIRESTOP' GYPSUM BOARD 2 LAYERS ON FACE, 1 LAYER INSIDE, BOTH SIDES #175 STC/57 STC/59 WITH INSULATION SOUND TEST R.A.L. FIRE RATING/2 HR. COMBUSTIBLE FIRE TEST FM WP-297 Malarial* Uaad 1. 2" x 4" Wood Studs 24" o.c, 2. Fireblocks--2" x 4" x 22y2 " 3. Vi" Firestop Type X Gypsum board 4. 8d Coated Box Nails 5. 6d Coated Box Nails 6. 6d Nails 7. 12d Common Nails W GYPSUM BOARD OVER COREBOARD #200 STC/47 SOUND TEST OR-64-39 FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST T-2575 Malarial* Uaad 1. 3" x 1 Vt" Wood Perimeter Framing 2. 1" x 24" Tongue & Groove Coreboard 3. Vi" Gypsum board 4. Laminating Compound 5. 8d Nails 17 Vi* QYPSUM BOARD OVER CORE BOARD WITH INSULATION IN CAVITY #202 STC/57 SOUND TEST OR-64-S9 FIRE RATING/3 HR. NON-COMBUSTIBLE/EST. Material* Used 1. 1"x1i" Wood Strips 2. 1' x 24" Tongue & Groove Coreboard 1. Vi' Gypsum board 4. 2" Insulation 5. Laminating or Joint Compound 6. 5d and Sd Nails FIRESTOP* GYPSUM BOARD 1 LAYER EACH SIDE #300 STC/35 SOUND TEST OR-64-81 FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST T-2316 Materials Used 1. IVt' Steel Studs, 24" o.c. 2. 1 V " Floor and Ceiling Track 3. ' Firestop Type X Gypsum board 4. 1" Type S Gy->sum board Screws Vt" FIRESTOP* GYPSUM BOARD 1 LAYER EACH SIDE WITH INSULATION IN CAVITY #328 STC/41 SOUND TEST OR-66-5 FIRE RATING/1 HR. NON-COMBUSTIBLE Materials Used 1. 2Vi" Metal Stud 24" o.c. 2. 2Vi" Metal Track Top and Bottom 3. Vi "firestop Gypsum board 4. ?h' Insulation rB. 1" Gypsum board Screws %" FIRESTOP* GYPSUM BOARD 1 LAYER EACH SIDE WITH INSULATION IN CAVITY #302 STC/44 SOUND TEST OR-64-81 FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST T-2316 Materials Ussd 1. 1a" Steel S'.uds, 24" o.c. 2. 1 " Floor and Ceiling Track 3. b" Firestop Type X Gypsum board 4. 1 Vi" Insulation I SGP 0023654 18 I r Vi" FIRESTOP GYPSUM BOARD f_ 1 LAYER OVER Va " GYPSUM SOUND deadening board each side #304 STC/45 SOUND TEST BW16FT FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST T-3854 & U410 (U.L 32) Materials Uaed .1. 2Vi " Steel Studs, 24" o.c. 2 2Va" G-P Steel Track X y* Gypsum Sound Deadening Board 4. 1" Type S Gypsum board Screws 5. Va' Firestop* Type ' XX Gypsum board or Firestop EtemawalP6 Gypsur board Georgia-Fbcific Vi" FIRESTOP* GYPSUM BOARD OVER Va " GYPSUM SOUND DEADENING BOARD WITH INSULATION IN CAVITY #306 STC/50 SOUND TEST BW17FT FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST UL U410 Materials Used 1. 2ya" G-P Steel Studs, 24" o.c. 2. 2ya" G-P Steel Track X 2" Insulation A. V*" G-P Gypsum Sound Deadening Board 5. 1' G-P Type S Gypsum board Screws 6. Ya' Firestop Type XXX Gypsum board or Firestop EternawallTM Gypsum board %" FIRESTOP* GYPSUM BOARD OVER Va" GYPSUM SOUND DEADENING BOARD WITH INSULATION IN CAVITY #308 STC/54 SOUND TEST BW18FT FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST UL U410 Materials Used 1. 2'/a * G-P Steel Studs, 24" o.c. 2. 2'/a" G-P Steel Track X 2" Insulation 4. '/* G-P Gypsum Sound Deadening Board 5. 1" G-P Type S Gypsum board Screws 6. V*" Firestop Type X Gypsum board or Firestop EternawallTM Gypsum board 7. 1 y" G-P Type E Gypsum board Screws | 5/8* FIRESTOP TYPE X APPLIED VERTICALLY 2" FIBERGLASS INSULATION 2V," STEEL STUDS 1/4" GYPSUM SOUND DEADENING BOARD APPLIED VERTICALLY 2V4" STEEL TRACK 19 SGP 0023655 Vi" FIRESTOP* GYPSUM BOARD, LAYERS 2 SIDES WITH INSULATION IN CAVITY #310 STC/48 SOUND TEST BW12FT FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST T-3218 (fiberglass insulation not required for fire rating) Materials Used 1. Z'h " G-P Steel Studs, 24" o.c. 2. 2Vi" Poor and Ceiling Tracks 3. Vi ' Firestop Type XXX Gypsum board 4. 2" Insulation 5. Laminating or. .int Compound %" FIRESTOP' GYPSUM BOARD, 2 LAYERS 2 SIDES #314 STC/46 EST. FIRE RATING/2 HR. NON-COMBUSTIBLE/EST. FIRE TEST T-2557 Materials Used 1. 2Vi" G-P Steel Studs, 24" o.c. 2. 2Vj" Floor and Ceiling Track 3. %" Firestop Gypsum board, 2 layers each side 4. 1" TypeS Screws %" FIRESTOP* GYPSUM BOARD, 1 LAYER 1 SIDE, 2 LAYERS OTHER SIDE #312 STC/43 SOUND TEST 1R-63-2 FIRE RATING/1 % HR. NON-COMBUSTIBLE/ EST. Materials Used 1. 2Vi " G-P Steel Studs, 24" o.c. 2. 2Yi" Poor and Ceiling Track 3. V".Firestop Type X Gypsum board 4. t^and 1 y" Type S Gypsum board Screws Vi" FIRE rOPr GYPSUM BOARD, 1 LAYER 1 SIDE, Vi" G-P REGULAR, 2 LAYERS OTHER SIDE #316 STC/48 EST. FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST T-4848 Materials Used 1. 3Ve" Steel Studs, 24" o.c. 2. 3%" Track 3. '/2" Firestop* Type XXX Gypsum board 4. 'h " Regular Gypsum board. 2 layers 5. 1 Vi" Insulation (not required for fire rating) 6. 1" and 1W Type S Screws SGP 0023656 20 M" FIRESTOP* GYPSUM BOARD, 2 LAYERS 1 SIDE, 1 LAYER OTHER SIDE WITH INSULATION IN CAVITY #318 STC/50 SOUND TEST OR-64-51 FIRE RATING/1 % HR. NON-COMBUSTIBLE FIRE TEST T-3126 Material* Uaad 1. 3y" Steel Studs, 24" o.c. 2. 3V" Floor and Ceiling Track .3 V" Fi restop Type X Gypsum board 4. 3" insulation 5. Laminating Compound 6. 1" and 17* " Type S Gypsum board Screws %" FIRESTOP' GYPSUM BOARD, 1 LAYER 1 SIDE, 1 LAYER OVER W FIBER S.D. BOARD OTHER SIDE #320 STC/44 SOUND TEST OR-65-10 FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST T-2557 Material* Uaad 1. 3V" Steel Studs, 24" o.c. 2. 3V" Floor and Ceiling Track 3. Vi" Fiber Sound Deadening Board 4. Laminating Compound 5. Vi" Firestop Type X Gypsum board 6. 1" and 1 Vi' Type S Gypsum board Screws 5/8" FIRESTOP 3H" STEEL STUDS 1/2" SOUND DEADENING BOARO 3W" FLOOR TRACK %" FIRESTOP" GYPSUM BOARD, 2 LAYERS 2 SIDES #322 STC/47 SOUND TEST OR-64-52 FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST T-2557 Material* Uaad 1. 3ye" Steel Studs, 24" o.c. 2. 3yB" Floor and Ceiling Track 3. Laminating Compound 4. ya" Firestop* Type X Gypsum board 5. 1" and 1 y" Type S Gypsum board Screws SGP 0023657 21 %" FIRESTOP* GYPSUM BOARD, 2 LAYERS 2 SIDES WITH INSULATION IN CAVITY #324 STC/52 SOUND TEST OR-64-50 FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST T-2557 Materials Used 1. 3V" Steel Studs, 24'' o.c. 2. 3Va" Floor and Ceiling Track 3. V>" Firestop Type X Gypsum board 4. 2" Insulation 5. Laminating or Joint Compound 8. 1" and 1 Vt" Type S Gypsum board Screws W FIRESTOP* GYPSUM BOARD, OVER y4 " GYPSUM SOUND DEADENING BOARD #415 STC/41; IIC 75 (WITH CARPET & PAD) SOUND TEST G&H BW 2-MT FIRE RATING/1 HR. NON-COMBUSTIBLE EST. BASED ON L 503 (U.L. 46) Materials Used 1. 2" x 10" Wood Joists 2. Carpet and Pad 3. Va" Particleboard Underlayment 4. Va" CD Grade Plywood Subfloor 5. Vt " G-P Gypsum Sound Deadening Board 6. Vi" Firestop* Type XXX Gypsum board 7. 4d Ring Shank Nails; 6d Common Nails; 8d Common Nails %" FIRESTOP' GYPSUM BOARD, OVER V4" GYPSUM SOUND DEADENING BOARD #326 STC/47 STC/52 WITH INSULATION* SOUND TESTS: BW-33ST/BW 34ST FIRE RATING/1 HR. NON-COMBUSTIBLE Materials Uaed 1. 1 Va" Steel Studs, 24'' o.c. 2. 1 Va" Floor and Ceiling Track 3. Vi" G-P 'A" Gypsum Sound Deadening Board 4. Va" Firestop Type XXX Gypsum board or Firestop Eternawall'" Gypsum board 5. 1 y* " Type S Gypsum board Screws "8. 1'A" Type S Gypsum board Screws .7. 1/a''x6"x12" Gypsum board Spacers 8 2" Insulation Batts (on BW-34ST for 52 STC) 1/4" GYPSUM SOUND DEADENING BOARD APPLIED VERTICALLY 1/2" FIRESTOP TYPE XX* APPLIED VERTICALLY 1H- STEEL STUDS GYPSUMBOARD SPACERS FIRESTOP' GYPSUM BOARD ON RESILIENT METAL FURRING (FLOOR/CEILING) #402 STC/47 SOUND TEST TL 65-155 FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST L502 (U.L. 33) Materials Used 1. 2" x 10" Wood Joists 2. Rosin Building Paper 3. 1" x 6" Tongue and Groove Subflooring 4. 1" x 4" Tongue and Groove Finished Flooring 5. Donn DG-B Resilient Channels 6. Va" Firestop* Type XXX Gypsum board 7. 1" Type S Gypsum board Screws and 8d Nails i m" floor track 22 SGP 0023658 ft" FIRESTOP GYPSUM BOARD ON RESILIENT METAL FURRING (FLOOR/CEILING) #404 STC/48 SOUND TEST L-224-4 FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Uaad 1. 2" x 8" Wood Joists--16" o.c. 2. y" Plywood 3. 44 oz. Wool Carpet 4. 40 oz. All Hair Pad 5. 3" Insulation 6. Resilient Channels 7. ye" Firestop Type X Gypsum board .8 8d Nails 9. 1 * and 1V*" Gypsum board Screws GeorgiaF&cific ft" FIRESTOP` GYPSUM BOARD ON RESILIENT METAL CHANNEL 24" O.C. #420 STC/53; IIC 72 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST FC 181 (FM) Materials Used 1. 2" x 10" Wood Joists 2. Vs" Plywood Subflooring 3. 3/e" Particleboard 4. 1 Vi " Nails 5. 8d Nails 6. '/2 " Firestop* Type XXX Gypsum board 7. Resilient Channel 8. 8d Nails 9. 1" Gypsum board Screws 10. 3'/2 " Insulation 11. Carpet and Pad ^ ft" FIRESTOP` GYPSUM BOARD INSULATION WITH CEILING INDEPENDENT OF FLOOR #406 STC/51; INR + 29 SOUND TESTS: KAL-224-14, KAL-224-15 FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Uaad 1. 2" x 8" Wood Joists 2. V2" Plywood 3. 44 oz. Wool Carpet 4. 40 oz. All Hair Pad 5. 8d Nails. 6. 2" x 4"'Joists .7. 3" Insulation 8 V*" Firestop* Type X Gypsum board ft" FIRESTOP' GYPSUM BOARD ON RESILIENT METAL CHANNEL #475 STC/50/EST.; IIC/70/EST. (WITH CARPET & PAD) FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L. L513 Materials Used 1. 2%2" T. & G. Plywood 2. Adhesive 3. ye" Gypsum board Strips 4. 2" x 10" Wood Joists 5. Resilient Furring Channels 6. ye" Firestop Type X Gypsum board 5/8" FIRESTOP GYPSUM80ARD 23 SGP 0023659 H"F/SrOP GYPSUM BOARD2 HR. RATING-INCOMBUSTIBLE, FLOOR/CEILING Gypsum board U.L Design G505 (UL 259)--2 Hr. (with 2" concrete) G-P produces lighter weight board and better fire resistance! Vs" Firestop Gypsum board reinforced with glass fibers covers many rating listed by Under writers' Laboratories for the %" thick material. This means that G-P fire-rated board can be used in most kinds of wall, floor and ceiling assemblies. The 10% reduction in weight can result in savings in labor and materials in multiple story construction. Concrete Floor Metal Lath Steel Bar INSTALLATION DETAILS APPLICATION OF RIGID PREDECORATED PANELS TO GYPSUM SUBSTRATE Use W or Vi" gypsum board. Attach to studs with 1 %" gypsum board nails, 1 " gypsum board screws (metal studs) or drywall stud adhesive. Joints need not be taped or sealed. Install the gypsum board vertically with the edges centered on the framing members. The rigid predecorated panels should be applied using a bead of panel adhesive over each stud. Se cure paneling at top and bottom plates with 4d finishing nails 12" o.c. Field fasteners not required unless panels are bowed. The addition of gypsum board as a substrate when using predecorated panels provides increased FIRE RESISTANCE and SOUND CONTROL. TEST RESULTS Paneling Paneling with H" (No Gypeum) Gypeum Paneling with Yt" Gypeum Burn thru Time Better Sound Rating Better Impact Resistance 8 min. 42 min. 73 min. (plus) 28 STC 40 STC 40 STC 26 82 82 Metal Furring Channel UL Design G505 attachment details 24 SGP 0023660 application over masonry WALLS On masonry walls either above or below grade, be sure the wall is properly waterproofed before furring is applied. Although moisture barrier gypsum board are available--there is obviously no substitute for proper waterproofing. Wood Strip* or Metal Channel*: Apply furring horizontally or vertically. Space 16" o.c. for V*" and Vs" gypsum board, and 24" o.c. for Vz" and Vs" gypsum board. Use concrete stub nails or power driven fasteners to install furring. Gypsum board should be applied perpendicular to furring. Use G-P insulating Gypsum board. Georgia-fecific WATER RESISTANT GYPSUM BOARD G-P Tile Backer Board is a water-resistant gypsum product with a light blue face paper, designed for use as a base for the adhesive application of ce ramic, metal or plastic tile. The gypsum core consists of incombustible gypsum rock, combined with an emulsion giving high water resistance. This product is ideal for bathrooms, kitchens, powder rooms and all high moisture areas. For fire rated partitions between bathrooms or in terior areas subject to moisture use Ve' Firestop* Tile Backer proven by Underwriters' Laboratories in a 1 -hour assembly over wood studs. The raw edges of Tile Backer Board (end joints, cut edges, cut-outs) are to be caulked with a coating of the waterproof compound used in applying the tile. As an alternate to caulking, G-P can provide a spe cial 2Vz" wide self-adhering vinyl tape to place over edges and cut-outs. Grabltn', a Masonry Adhesive: Apply 1' ribbons of Grabit to each edge and 16" o.c. in field of back of each piece of gypsum board. Be sure face to be covered is reasonably straight, and free of frag ments of mortar or other protrusions. The adhesive fills in irregularities in the masonry surface. Grabit may also be used to apply gypsum board to polystyrene insulation material that has been used against the masonry. Grabit may be used without waterproofing on exterior walls which are above grade. Temporary fasteners or bracing may be necessary until Grabit sets. *Grabit is a trademark of Georgia-Pacific Corporation. SGP 0023661 'For fir* and sound rated construction the Tile Backer Board must extend to the floor. 25 SOLID AND SEMI-SOLID GYPSUM PARTITIONS Partition systems composed entirely of gypsum board have the added values of increased fire re sistance and maximum use of space. In the following four systems the common factor in each is that they are all constructed (except for floor ceiling runners) entirely of gypsum incombustible materials. 2" SOLID LAMINATED-- (NON-LOAD BEARING) A 1' gypsum coreboard with Vi " gypsum board laminated to each side; no air space. A 2' solid wall system has a 2 hour fire rating, an STC rating of 35, produces smooth monolithic walls and creates extra usable floor space. 2" SOLID LAMINATED FLOOR AND CEILING DETAILS CiuikiAg ' Mt tiptng lo citin| fibtrflits or noft-eombuttibt* resilient materiel Ctuiking Concrete nail or power shot fastener. CONCRETE CEILING CONCRETE CHUNG insulation. Outer section of wall (on both sides) is Vi" gypsum board laminated to 1* coreboard (this gives a IVi" wall on both sides of center section) This system has a three hour fire rating, a 57 decibel STC and produces smooth monolithic walls. A ^ COLUMN FIREPROOFING Fireproofing with Firestop Gypsum board provides a fast, efficient and economical method of protect ing steel columns. Fire resistant assemblies of two, three and four hours are obtainable depending upon the number of layers of %" or Vi" Firestop Gypsum board .sed. These layers are held in place by a combination of screws and metal studs. The two, three and four hour fire rated assemblies of Firestop Gypsum board have passed Official Fire Tests conducted by the Underwriters' Laboratories. Fire Resistor --For three hour protection, two layers of Vi ' irestop Type XXX can be used. Test No. X513 (UL 19-3 hour). Two hour protection can be obtained usin' 1 layer of Vi" Firestop Type XXX Gypsum boar Test No. X520 (UL 20-2 hour). These are for heavyweight columns (14 W.F. 228). For lightweight columns (10 W.F. 49) use 4 layers of Va" G-P Firestop Type X for 4 hour protection, 3 layers for 3 hours. Test No. X509 (UL 18) and 2 layers for 2 hour, Test No. 517 (UL 8). Lighter--As compared to other types of fireproof ing, a dead load savings of from 50 to 75% can be realized with G-P Firestop Column Fireproofing. Speed of Erection--Firestop Gypsum board can be installed quickly and easily when used for column fireproofing following G-P details. Minimum amount of the wire and adhesives are used. WOOD FLOOR DETAIL CONCRETE FLOOR DETAIL 2Vi" SEMI-SOLID LAMINATED GYPSUM BOARD 214' Semi-Solid Laminated--(Non-Load Bear ing)--A center vertical rib (or stud) composed of 2 layers of laminated gypsum board (1 "x6* rib, 24" o.c.) is the base upon which gypsum board is laminated to each side. This leaves intermittent 1' dead spaces for wiring. The 2VSt' system has a 1 hour fire rating, money saving simplicity of installa tion, a 30 decibel STC, creates smooth walls and provides extra floor space. Y*" DOUBLE SOLID LAMINATED-- (NON-LOAD BEARING) Consists of laminating Vt ' gypsum board to a 1' tongue and groove coreboard homogenous or lam inated on each side of a 3* air space. There is abso lutely no connection over the air space except at the jambs. This system has a 2 hour fire rating, greater strength than standard frame or thin solid wall, a 47 decibel STC and produces smooth wall surface. TRIPLE SOLID LAMINATED-- (NON-LOAD BEARING) The center piece is a 1' gypsum core panel running the height and length of wall, on one side of which is dead space the other side is filled with fiberglass 26 THREE-HOUR fire rated steel column assembly with V" Firestop. X509 (UL 18). Minimum size of column W10X49. TWO HOUR fire rated steel column assembly with V" Firestop. X517 (UL 8). Minimum size of column W10X49. SGP 0023662 Georgia-Ffecific ^ WOOD AND STEEL STUD APPLICATION There are many different kinds of construction sys tems and ail are based on the requirements of your particular building installation. Basically, the main considerations are usually: Fir* Resistance, Sound Transmission, Relative Strength of the installa tion, Dimensional Restrictions and Economy. After the wall and floor/ceiling constructions have been selected, it is important that they be installed properly. The following orecautions should be taken during installation to avoid situations or conditions which will detract from the sound control properties of the assembly. Avoid connecting plenum chambers, ducts, vents, etc. These permit the jnrestricted flow of sound. Corrective measures are to make partitions full height, and use ducts lined with absorbent material. Materials: All gypsui board shall be G-P Gypsum board Vi' or Vs' ,hick Regular or Firestop*, 4' wide x ceiling height 'or vertical application or up to 16' long for horizontal application, tapered edge. All joint treatment products are to be G-P materials. Framing: Prior to the gypsum board application, all framing members should be true and firmly fastened in a plane surface. Provide double studs at all cor ners. Both inside and outside intersections are formed by extending one edge of a panel over the other edge in a flush position and covering with tape and joint treatment. In single ply installation, all ends and joints of gypsum board shall occur over framing members, except that this is not required for treated joints at right angles to framing members. Application: Gypsum board may be applied hori zontally or vertically to framing with nails or screws. (Alternate method-stud adhesive may be applied to studs before applying gypsum board.) The gypsum board shall be attached with nails meeting ASTMC514 or with 1V*" long G-P Type "W" gypsum board screws or 1* long G-1 Type "S" gypsum board screws, for wood and metal or framing, respectively. SINGLE PLY GYPSUM BOARD MAXIMUM FRAMING SPACING* Thickness Maximum Spacing Application Vk* on walls Vi" on walls W* on walls Vi* on callings Vi* on callings* Vi' on callings* Si" on ceilings 16* o.c. 24" o.c. 24* o.c. Not recommended 16* o.c. 24' o.c. 16'' or 24' o.c. Horizontal or Vartica! Horizontal or Vartical Horizontal or Vartical Not recommended Parallel* or Perpendicular Perpendicular* only Parallel or Perpendicular 'Important Notea: Water based spray texture finishes are not to be applied to G.P. Vi' thick gypsum board applied parallel to joists spaced 16' o.c., or to G.P Vi* thick gypsum board applied perpen dicular to joists spaced 24* o.c. For these installations. Vi* thickness must be applied. Do not install Vi' thickness parallel to joists that are spaced 24' o.c. NAILING OR SCREW SPACING FOR SINGLE-PLY GYPSUM BOARD Gypsum bosfd Thickness Single Nailing Double Nailing 44' sidewalls................ 8" o.c. Max..................12" o.c. Max. Vi" sidewalls.................8" o.c. Max................. 12" o.c. Max. ys" ceilings...................7" o.c. Max..................12" o.c. Max. 44" sidewalls................ 8" o.c. Max..................12" o.c. Max. ceilings...................7" o.c. Max..................12" o.c. Max. Qypeum board TNcfcnaaa Framing 16" o.c. Framing 24" o.c. Screw Spacing Screw Spacing Vt" sidewalls............. 16" o.c. Max................. -- V4' sidewalls................. 16" o.c. Max.............. 12" o.c. Max. 44" sidewalls................. 16* o.c. Max.............. 12" o.c. Max. Vi' & 44" ceilings... 12" o.c. Max..................12" o.c. Max. NOTE: Nails or screws should be dhven not less than Vs" from edges or ends of panels. While fasteners are being driven, the gypsum board shall be held In firm contact with the underlying supports. Preferably, application of fasten ers should proceed from the central portion of the gypsum board to the ends and edge. Dimple nails or screws with out breaking the face paper. Joints.* All joints should be taped and finished with tape and joint compound, nail or screw heads should be finished with joint compound. Ex terior angles are covered with G-P Metal Casing Beads and finished with joint compound. 27 SGP 0023663 GYPSUM BOARD PRODUCTS Georgia-Pacific Gypsum Division manufactures a full range of products to meet the needs of the con struction industry. The versatile gypsum product provides builders with lightweight construction materials that are workable, fire and noise resistant and time saving. G-P research facilities have re sponded to the industry's requests and have de veloped the following multi-use, highly reliable, low cost products. G-P GYPSUM BOARD EDGES T--Tapered S--Square RE--Tapered v th Round Edge B--Beveled (Sf acial Order) T & G--Tongue and Groove MB--Modified "'eveled Edge See page 31 for detailed description G-P REGULAR GYPSUM BOARD G-P Regular Gypsum board is faced with a strong, cream colored paper which will accommodate almost any type of decorative treatment. The back paper, which is gray, is as strong as the face paper. The V2" and %" tapered and round edge gypsum board are recommended for single layer application in new construction. They are designed to be rein forced with G-P Joint System products resulting in a smooth, seamless surface. Square edges are recommended for use where joints will be exposed. The resistance to fire exposure and sound transmission increase with thickness and the number of layers of board used. Bevel edges can be used where a panel effect is desired. G-P V4" GYPSUM SOUND DEADENING BOARD G-P V*" Incombustible Gypsum Sound Deadeninn Board meets the requirements of the most sophisti cated sound control systems available with the added convenience of being one of the easiest sound control materials to install. When combined with other gypsum board, it reduces sound trans mission, has high structural strength, is non combustible. It has a distinctive green face paper When applied over 2 Vi" steel studs or 2 x 4 wood studs, one layer of Vi" Firestop Tvpe XXX Gypsum board over one layer of Vi" Gypsum Sound Deadening Board produces a 1-hour fire resistive wall and a 45 S.T.C. Thickness Width* Length* ----1 Edg* I 'A" 4' 8' S! G-P REGULAR TILE BACKER BOARD This is a water-resistant gypsum product with a light blue face paper, designed for use as a base for the adhesive application of ceramic, metal or plastic tile. The gypsum core consists of non-combustible gypsum rock, combined with an asphalt wax emulsion giving high water resistance. Ideal for bathrooms, kitchens, powder rooms and other moisture areas. G-P Tile Backer Board can be erected as easily as regular gypsum board and requires no finishing of joints or nail heads with joint treatment nor further waterproofing under tile applied adhesively unless required bv local code. ThicknH Width* Lengths Edg* V2" 4' 8' tol? T Thickn*** Va" %" Vi" %" Vfdth* 4' Length* 6' to 16' in even feet Edge T, S, B, RE FIRFSTOP9 GYPSUM BOARD Fin&stop Gypsum board develops 45 minute to 3 hour fire resistant ratings in various wood and steel wall, floor/ceiling assemblies and column and beam protection. Textile glass filaments and other ingre dients keep the core intact, even after the chemically combined water has been released. Thickness Vi" Widths 4' Lengths 6'to 16' in even feet Edge T, S, B, RE FIRESTOP' TILE BACKER BOARD Same as Regular Tile Backer Board plus the addi tion of glass fiber reinforcement gives increased fire protection and strength. Where fire rated assemblies are required in areas subject to moisture, such as partitions between bathrooms and other interior areas, most building codes allow the use of Firestop Tile Backer Board. The use of 5/s" Firestop Tile Backer Board will give the same fire resistant rating as other Firestop board. Only in design 5-- 1 hr. rating. Thickness Widths 4' Lengths 8' to 12' Edge T G-P REGULAR INSULATING GYPSUM BOARD Regular Insulating Gypsum board with bright aluminum foil laminated to the back surface. The foil paper provides a continuous vapor barrier on the warm side of the wall. To have reflective insulation value, the foil must face a minimum air space of The aluminum foil, facing a %" minimum space, reflects 90% of radiant heat, providing insulation qualities equal to Vz" of fibreboard insulation (tested by U.S. Bureau 28 SGP 0023664 Georgia-F&cific of Standards). Panels must be installed with foil side against the studs. ThicknsM %" Vi" %" Widths 4' Lengths 6' to 16' Edgs T, S, RE FIRESTOP* INSULATING GYPSUM BOARD This is the regular insulating gypsum board with the addition to the core of glass fiber for increased fire protection. Through the proper use of this produot desired fire-rated assemblies can be achieved. ThickiMM Widths Lengths Edge 4' 6' to 16' | T, S, RE ______________ 1_____________ G-P REGULAR ETERNAWALLTM-- VINYL SURFACED GYPSUM BOARD Standard Une. Colors--Avocado, Gold, Flax, White, Beige, Stucco, Buff, Willow Green, Fawn, Snowdrift White, Alabaster, Tangerine, Cherry, Pecan and American Walnut. Special Colors and Textures. Colors--Honey Maple, Shadow Beige, Teak, Rosewood, Oak, Desert Yellow, Smokey Mint, Spanish Haze, Winter Green, Tarnished Gold, Powder Brown, Chocolate Malt, Autumn Orange, Burnt Sugar, Pebble White. This panel has the vinyl surface factory laminated to Regular Gypsum board. Available in a variety of colors and textures, it provides beauty and utility to commercial, institutional and home interiors. Eternawall is strong and resilient. The solid gypsum core is non-combustible. Eternawall color won't fade. The deep linen-textured vinyl surface can be scrubbed without damage to color, texture or design. Because of its ability to take hard wear and to resist stains, Eternawall Gypsum board is ideal for restaurants, hotels, clubs, tnd hospitals as well as home use. It is also ideally suited for movable partitions. ThicknsM Vi" (Special order %"&%") Widths 4' Lengths 8' (Other lengths available on special order.) Edgs MB FIRESTOP* ETERNAWALLTMVINYL SURFACED GYPSUM BOARD This panel has the vinyl surface factory laminated to a Firestop panel which has glass fibers added to the core to give it additional fire resistance. With this technically designed gypsum core, a 1 hour or greater fire rating may be obtained on wall assem blies. Same colors available as with regular Eternawall Gypsum board. Thickness __W__id_th_*__ Vi" 4' _________ Lengths 8' (Other lengths available on special order.) Edge MB GYPSUM SHEATHING Treated--G-P Gypsum sheathing consists of non combustible gypsum rock combined with an asphalt emulsion to provide high resistance to water. All G-P Gypsum sheathing is manufactured to meet A.S.T.M. C79, including requirement for water resistance. This eliminates the need for building paper (except where required by local building code). An untreate i (non-water resistant) gypsum sheathing is available. The 2' wide sheathing, applied horizontally, is made with precision formed tongue and groove edges and square edges. The 4' wide square edge sheathing, applied vertically, eliminates the need for corner bracing. It is designed to meet the require ments of F.H.A. Technical Circular 12 (no corner bracing). There are two types of sheathing, Firestop sheathing, which, combined with s/e" Firestop wallboard on the interior wall side, meets a 1 hour fire resistance rating, and Vt" Regular sheathing, used where no fire resistance rating is required. ThicknsM Widths Lengths Edge Vz' Reg., 4k " Firestop' Vz' Reg., %" Firestop- 2` 4' 8' 8' & 9' T&G S GYPSUM FIRES 'OP' BACKER BOARD Vs" Firestop Gypsum Backer is used as a back ing for decorative surface treatments of acoustical plasters, tile, plywood and various veneers. A single layer application of %" G-P Firestop Gypsum Back er on both sides of wood or steel framing, enables loadbearing or non-loadbearing wall assemblies to resist temperatures rising to 1700 F. in one hour following the ASTM standard time temperature curve. Firestop Gypsum Backer consists of a gypsum core with literally miles of high tensile strength glass fibres, firmly bonded to a fibrous gray paper on both sides. ThicknsM Width* i Lengths Edge Vi" 2' & 4' i 8' to 16' S, T&G ; G-P REGULAR BACKER BOARD G-P Gypsum Backer Board is designed for first or base layers in field lamination of gypsum board, for acoustical tile and other compatible materials. Pro vides low cost, even surfaces for further decorative treatments. It may be applied over loadbearing or non-loadbearing wood or metal framing with nails, screws or staples. ThicknsM Widths Lengths Edge %" 2' & 4' 8' to 16' S.T&G Vi" 29 SGP 0023665 ! i i I PREDEC " TEXTURED GYPSUM BOARD This combination of non-combustible gypsum board with factory applied, distinctive, evenly balanced textures is a new development in the construction industry. The textures are baked on and are available in 2 patterns, sand and stucco. The panels are fts", Va" and Va" thick with square edges. The texture is a thermo-set in White, Beige, Gold and Light Green water resistant paint. This product eliminates job site finishing and instal lation time. It is impact and abrasion resistant and ideal for residential construction, factory built mobile and modular homes and movable or fixed partitions. It can be cleaned with a damp cloth and mild soap and water. PreDec has a flame spread rating of 20. Samples available on request. This product also available without the texture under the name "PreDec Blanks." Thickness 5/16" (%"&%" special order) Widths 4' Lengths cut to size Edgs S SENTINEL " BOARD Developed particularly for mobile homes, Sentinel board has a tough, stain resistant, special decorated paper face laminated to the wallboard. It has a 20 flame spread rating and its incombustibility makes this product highly desirable for mobile homes. Pat terns are Oak and Pecan designs. atop metal "J" track and bottom "U" track Metal "I" studs 2Va '' deep separate each shaft liner boarri and have opposed tabs 12" o.c. The 1 " shaft liner panels are secured by a friction fit between the tah and the flange of the "I" stud. A cavity space iy2"DS deep is provided and the cut-outs in the studs facili tate horizontal services. The required Va" Fireston ' Type XXX facing layers are screw attached to the face of the `T stud. Height limit varies depending upon gauge metal and depth of stud. Fire resistance rating is two hours based on ASTM E-119 test. Thickness 1%" or r Core plus facing layers Widths 2' Lengths cut to size Edge S G-P 1" COREBOARD 1" Gypsum Coreboard is available in two styles. a. A homogenous core with a tongue and grooved joint. b. Two layers of Va" backer board, laminated. 1 * Gypsum Coreboard is used for the core material in various, all-gypsum partition assemblies. Thickness 1" Widths 2' Lengths Custom cut up to 14' Edgs S.T&G Thickness 5/16" Widths 4' Lengths cut to size Edge S SHAFT LINER M SYSTEMS The shaft liner systems are non-load bearing gypsum board partitions for enclosing elevator shafts, stairs, smoke towers and other vertical openings. They are designed for resistance to air pressure (lateral force) without excess deflection. These systems can reduce weight over 20 lbs. per sq. ft., compared to masonry, are non-combustible and can be erected from one side, eliminating the need for scaffolding. They/ere also excellent fire rated separation walls. "T" Spline System: The partition consists of a basic factory or field laminated liner panel 1 Va" thick by 24" wide which fits into a top metal "J" track and bottom "L" runner. Metal "T" splines separate each panel which is then screw attached to the "T" splines and top and bottom runners. The required facing layers are attached to the liner panel for the solid type, to furring channel for the cavity type, or to metal studs for the chase wall. G-P shaft liner panels are available in lengths up to 16 ft. With splicing and auxiliary bracing, heights beyond 16 ft. are attain able. Various fire resistant ratings in accordance with ASTM E-119 and sound ratings in accordance with ASTM E-90 are available. Fire tests were con ducted by UL and Ohio State University. "I" Stud System: This partition consists of a single shaft liner board 1 * thick by 24" wide which fits into G-P SOFFIT BOARD G-P Gypsum Soffit Board is used on exterior soffits where not exposed directly to the weather. It's an in expensive soffit material for schools, shopping cen ter malls, apartments and houses. It finishes and decorates like interior gypsum board with no nails or joints showing. It has light blue face paper for identification. Thickness Va", %" Widths 4' Lengths 8' Edge RE G-P FIRE FIGHTER GYPSUM BOARD New product designed for use on roofs, over rafters, and under sheathing and roof covering. Tests prove it blocks roof fires from entering attic and living areas. It has a special core and paper. Thickness Va" Widths 2' Lengths 8' Edge S DENS-COTE* GYPSUM PLASTER BASE A 4' wide, long length, tapered edge, plaster base. For use as a base layer for G-P Dens-Cote* veneer plaster. It has a highly absorbent face with pinholed surface. SGP 0023666 30 Georgia-Ffecific Thickness Vz" %" Reg. and Vz" and Fi restop* Widths 4' Lengths 8', 10', 12' Edgs T ; DENS-COTE* VENEER PLASTER j One coat and two coat systems give a strong durI able finish with maximum speed and minimum mai terial. Apply total thickness of . Available in ' smooth or textured finishes. 80 lb. bags. I TAPERED EDGE: ^ The tapered edge was originally ! called the "recessed edge" but is | now commonly called tapered, because of the incline from the edge to about 2" into ' the board. This taper allows space for tape and joint ; treatment to be applied and the completed job will be flat, smooth and monolithic. I 1 SQUARE EDGE: J i The gypsum board square edge was the original wallboard edge. Initially designed to be a base with I a final covering such as wallpaper, paneling, or tile, , square edge can be finished with joint compounds to form a clean monolithic wall suitable for paint. Also can be used where an exposed joint is desired. 9tAPEREDw/ROUND EDGE: Georgia-Pacific round edge (RE) r~r--i gypsum board can be used for wall and ceilings in both new construc tion and remodeling. It is designed to reduce the 1 beading and ridging problems commonly associated with standard type gypsum board. The edge forma tion provides a stronger, more rigid joint and reduces joint beading or ridging. BEVELED EDGE: The beveled edge is a suitable edge to give a paneled effect. After fasteners are covered with joint compound the board is ready for paint with grooves exposed. "T & G" EDGE: Georgia-Pacific's "tongue and groove" edge is used on 2' wide sheathing and backer boards. t-'- i I MODIFIED BEVELED EDGE: The modified beveled edge is available only on EternawallTM panels. This particular edge more readily accommodates the vinyl surface decoration, which is delivered completely edge wrapped. The vinyl surface material is available in 15 standard patterns and colors and 15 new colors and textures. JOINT SYSTEM PRODUCTS G-P Joint System products are designed to conceal joints and nail heads and surface-weld'' gypsumboard panels together. Properly used, these prod ucts assure smooth, seamless appearance of walls and ceilings, with joints stronger than the gypsumboard itself. Many G-P joint system products come with an asbestos free formulation. Check with your nearest G-P Distribution Center. G-P BEDDING COMPOUND Bedding Compound is designed to provide maxi mum adhesion of tape to the joints and for initial ap plication to nail heads and corner bead. It spreads smoothly and may be hand or machine applied. Coverage: 15 to 20 lbs. per 1,000 sq. ft. (Used in conjunction with 40 to 45 lbs. of Topping Com pound.) 25 lb. bags. G-P TOPPING COMPOUND G-P Topping Compound is specifically designed for the second and third coats over the bedding com pound. Since it is used only for topping, the amount of adhesive can be reduced and other materials in corporated which reduce the shrinkage and make it easier to sand and work. Coverage is approximately 40 to 45 lbs. per 1,000 square feet. (Used in con junction with 15-20 lbs. of G-P Bedding.) Available in 25 lb. bags. TRIPLE DUTY " JOINT COMPOUND Triple Duty Gypsum board Joint Compound is a vinyl multipurpose joint system product. A single bag offers taping, topping and texturing. It can be used for all coats in the reinforcing and concealing of joints in gypsumboard construction. The binder, a vinyl, gives this product a wet life of 30 to 60 days duration. This allows premixing in large quantities prior to application. Triple Duty can be applied using standard hand or mechanical tools. There is low shrinkage and it is easily sanded. When the applica tion is completed, the surface is ready for priming and decoration as desired with no further prepara tion necessary. Coverage: 60 lbs. per 1,000 sq. ft. 25 and 50 lb. bags. Can be used as a Texture. Cov erage: 12-50 lbs. per 1,000 sq. ft. G-P READY MIX JOINT COMPOUND Ready Mix Joint Compound is an easy-working ma terial for embedding the joint reinforcing tape and the filling and finishing of joints in gypsum board construction. Furnished in cans and cartons ready to use, this stable, all-purpose compound is also ex cellent for use in covering nail heads and forming interior and exterior angles. Ready Mix Joint Com pound assures a standard mixture for uniform work ability throughout the job. It has a long wet life and will not spoil even when the container is left open. Ready Mix Joint Compound produces an excellent surface for any type of decoration. Ready Mix Topping Compound also available. For best results, the surface should be primed before being deco rated. Coverage: 5 gal. per 1,000 sq. ft. Package-- 1 and 5 gal. cans, 4 gal. cartons. G-P ALL PURPOSE JOINT COMPOUND G-P All Purpose Joint Compound is used for bed ding tape, topping, corner bead, nail spotting and texturing. When taping be sure the compound under the tape, and the first coat over the tape is thorough ly dry before applying the next coat over the joints. When used for texturing, for best results, apply a 31 SGP 0023667 vinyl primer to the entire area before texturing. The texture may be applied with a roller, sponge, brush or can be sprayed, depending on the type of config uration desired. Coverage: 60 lbs. per 1,000 sq. ft. 25 lb. bag and packaged 18 lbs. of compound plus 250' roll of tape. SPEED SET Speed Set Joint Compound makes possible the taping and finishing of all gypsum board joints within a single day. It can be used for all coats. Speed Set is a setting rather than a drying type of compound, and will not shrink once it has set. Comes in two ways--for 1 hour working time, use Speed Set 90, for 2 hour working time use Speed Set 150. 25 Lb. Bag. WALL TEXTURES G-P Wall Texture is an unaggregated texture com pound for hand tool or spray application. When ap plied with a spray, a splatter or orange peel texture is formed. When applied by hand, a stipple, swirl, or brocade texture can be produced. G-P Wall Texture can be applied immediately after G-P Ceiling overspray wipedown. It is made for fast, volume application. Because of its formulation, G-P Wall Texture matches G-P Ceiling Textures, and al lows them to blend together. Coverage: 12-50 lbs. per 1,000 sq. ft. depending upon texture. 25 Lb. Bag. CEILING TEXTURES G-P Ceiling Textures are designed for spray appli cation over ceilings constructed with gypsum board or concrete. The resulting texture simulates acousti cal texture finish. VermicuIHe--A 40 lb. bag of this aggregate is avail able in 3 particle sizes (fine, medium and coarse). An ideal product for concealing surface defects. Coverage: 200-300 sq. ft. per bag. Texture samples available on request. Polystyrene--A new powder product in a 32 lb. baq This rich white texture finish has strong adhesion y with maximum coverage and excellent hiding quali ties. The fragments of this very rough texture retain their size and shape during mechanical mixing. Cov erage: 200-300 sq. ft. per bag. Especially designed for volume operations, these products give unsurpassed economy. The texture dries harder and tighter. The texture maintains a high quality white decorative finish, and gives exceptional coverage if used as instructed. G-P GYPSUM BOARD TAPE G-P Tape is a full 2" width, "Miracle Crease" spark perforated tape with skived edges and sanded sur face both sides. Excellent bonding qualities. Available in 60', 250' and 500' lengths. GRABIT ADHESIVE Grabit adhesive is an adhesive which permits direct attachment of gypsum board to masonry walls. It may be used on poured concrete, cinder block or concrete block walls which are reasonably straight and true and are free from surface treatment, decora tions, or protrusions. Grabit adhesive may be used on exterior walls which are above grade level without waterproofing. Grabit adhesive can be used to adhere gypsum board to polystyrene insulation material. Adhesion is secure and permanent, with no need for furring strips or fasteners. After being mixed with water as directed, Grabit adhesive can be applied with blade or caulking gun. Only four 1" ribbons are needed for each 4' wide gypsum board panel. The adhesive fills in all normal irregularities in the masonry. In 3 to 4 hours, Grabit adhesive sets hard, and joint taping and finishing operations may then be started. This adhesive may be used wherever there is need to attach gypsum board to masonry walls: in homes, apartments, hotels, offices, and plants. Coverage: Up to V lb. per sq. ft. depending on roughness of base surface. 50 Lb. Package. Texture rWall Texture Vermiculite Ceiling Texture Polystyrene Ceiling Texture Finish St FM &C C Bag Size Water Mix* 251b. 401b. 321b. Add 2% Gallons Add 3Vz Gallons Add 6 Gallons Remix Do not exceed 3% Gallons Do not exceed 5 Gallons Do not exceed 8 Gallons Average Coverage Gypsum board Spray 1,000 sq. ft. Trowel 200 sq. ft. Concrete Spray 400 sq. ft. 300 sq. ft. Spray 400 sq. ft. 300 sq. ft. *Mix until dry powder is wetted and well dispersed. Then allow to soak for 20 minutes. Remix and adjust to desired consistency. If desired, up to 1 Vi gallons of compatible water based paint may be added, per bag, to impart color. tS--Smooth (no aggregate) F--Fine M--Medium 32 C--Coarse SGP 0023668 ETERNAWALLtu GYPSUM BOARD COMBINES GYPSUM BOARD WITH THE BEAUTY OF SHEET VINYL These fire-resistant panels are factory laminated with a quality, washable vinyl sheet providing a per manent scuff, crack and chip-resistant surface. Col ors are fade-resistant and the texture or design will not be impaired when cleaned. Eternawall panels are available in 12 standard colors and 3 simulated woodgrains plus 15 new vinyl sur faces, including 10 colors in G-P's Burlap texture, 2 colors in weave and 3 new woodgrains. The long edge is completely wrapped with vinyl and eased to form a modified beveled edge*. Georgia-Pacific Firestop EternawallTM Gypsum board is available for use when the wall construc tion requires the gypsum board to be of fire rated construction. Firestop EternawallTM has a gypsum board base containing greater glass fiber reinforce ment and unexpanded vermiculite. SPECIFICATIONS All vinyl surfaced gypsum board scheduled and/or indicated on the drawings shall be Georgia-Pacific EternawallTM as manufactured by the Gypsum Divi sion of Georgia-Pacific Corporation. The panel con struction shall consist of supported or unsupported vinyl of "wall surfacing grade" factory laminated to G-P Regular or Firestop Gypsum board. The long panel edges shall be a modified bevel and com pletely wrapped with vinyl. The colors and patterns shall be as selected from the EternawallTM Gypsum board Standard Line or special new colors and textures. (See page 34 for colors.) Georgia-Racific Thickness: %" v, ,, board, %" and pfr^, /8,^e9ular Gypsum Regular ^3?^ Standard sizes: 4' x 8', 9' and 10' SDecial lenaths ava'lawe upon request ,n one toot avlLlle on soft erand width> ^ Vi" and % gypsum board consisting of qyn- sum core, surfaced on both sides with paper or with a vinyl facing on one side. Fir* Hazard ClaaaHicatlon Basle Board With Vinyl Facing Flame Spread 15 25 Fuel Contributed 15 io Smoke Developed 0 20-50 Classified by Underwriters' Laboratories, Inc. UL labeled Eternawall available. Color coated stainless steel nails are available to match all Standard colors and woodgrains. Trim ac cessories are available in 8' and 10' lengths to match all standard colors and woodgrains. Snap-On Corner Bead Snap-On Interior Trim EternawallTM Gypsum board Surfaced. These fire and sound rated vinyl-surfaced gypsum board systems eliminate the need for battens. Firestop EternawallTM is laminated directly to G-P 'A" incombustible Gypsum Sound Deadening Board. They are not only simple to install but they are inexpensive and provide a very durable wall, and very high STC ratings. Vi 0UILOING INSULATION DEMOUNTABLE PARTITIONS Demountable wall systems are installed by using any of the appropriate or approved color-matched mold ings. To laminate to existing wall surfaces, use G-P Laminating Compound and secure panels mechan ically at top and bottom plates. Panels may be applied with adhesive directly to metal studs, wood framing or furring strips. For application directly to masonry walls, use G-P GrabitTM Masonry Adhesive. Swatches are available by writing Georgia-Pacific Corporation, 900 S.W. Fifth, Portland, Oregon 97204. Fire Test U.L. U312 Fire Rating--1 Hour Combustible STC 50 System-106 Fire Test U.L U410 Fire Rating--1 Hour Incombustible STC 50 System #306 `Insulation not required for fire rating. 33 SGP 0023669 ETERNAWALU" GYPSUM BOARD I Tangerine GP-702 Walnut Design GP-682 Alabaster GP-703 Fawn GP-652 Cherry Design GP-681 Flax Design GP-688 Beige GP-687 New cglare and textures > > < ' r . ' i i < 1 . 11 . ' i` i i i*i t . i .. ' / i i i' iii Pebble White GP-101 Honey Maple GP-206 JHUk Pecan Design GP-683 White GP-686 i J >J. ) , | . i . T III* sv < i r 1i i <i i M 4 J ; s > 1 '* ` * ' ' 4 I I 1I < 1 I!l |/tJjliT* i >lj >i l , i1 i 1 M Desert Yellow GP-110 > s > 3 ; -- Powder Brown GP-102 Teak Design GP-695 ja&: Smotoy Mint <3^114 Chocolate Malt GP-107 -v>- Rosewood Design GP-696 Spanish Haze GP-112 Autumn Orange GP-105 SGP 0023670 Shadow Beige GP-205 Tarnished Gold GP-111 Georgia-ffecific ^ U.S. AND CANADIAN SPECIFICATION DIRECTORY - GYPSUM BOARD PRODUCTS Product G-P REGULAR GYPSUM BOARD Tapered Edge Square, Tapered or Round Edge Thleknasa Width 4' w 4' Vi" 4' w 4' Langth 6' to 12' 6'to 16' 6' to 16' 6' to 16' ASTM & CSA Standard* C 36 CSA A82 27 USOA Federal Specification SS-L-30d Type III--Grade R G-P INSULATING GYPSUM BOARD Square, Tapered Edge or Round Edge Vt" 4' 6' to 16' I C 36 SS-L-30d Vi" 4' 6' to 16' > CSA Type III--Grade R y8" 4' 6' to 16' \ A32.27 ETERNAWALUM GYPSUM BOARD Modified Beveled Edge SS-l-30d Vz " %" 4' 4' 8' Std.t 8' Std.t C 36 a CSA A82.27 Type III--Grade R or Grade X Class III FIRESTOP* GYPS M BOARD Square, Tapered dge or Round Edge Vz n Vt" 4' 4' 6' to 16' 6'to 16' C 36 CSA A82 27 SS-L-30d Type III--Grade X FIRESTOP* INSUL .TING GYPSUM BOARD Square, Tapered 2dge or Round Edge Vi" Vt" 4' 4' 6'to 16' 6'to 16' I C36 V CSA \ A82.27 SS-L-30d Type III--Grade X Q-P TILE BACKER BOARD Tapered Edge Vt" Vt" 4' 4' 8', 11' and 12' C630CSA A62.27 SS-L-30d Type VII Grade R, X, W G-P GYPSUM SOUND DEADENING BOARD Square Edge %' 4' 8' Std.f C 442 "CSA A82.35 SS-L-30d Type IV--Grade R G-P BACKER BOARD Square or T & G Edge Vt" 4' 8' Std.t I C 442 Vi" 2' 8' Std.t > CSA W 2' trstcTt \ A82.35 SS-L-30d Type IV Grade R Grade X FIRESTOP* GYPSUM SHEATHING Long-Edges - Square Edge Core-treated or non core-treated Square or Tongue and Groove Core-treated or non core-treated Vi" Vi" C 79 4' 8' & 9' a CSA A82.27 C 79 2' 8' Std.t CSA A82.27 SS-L-30d Type II Grade R&W (V2") or Grade X&W (%'') DENS-COTE* PLASTER BASE C 588 Vi" 4' 6' to 12' CS - Vt" A62~27 SS-L-30d Type VI Grade R FIRESTOP' DENS-COTE* PLASTER BASE C 588 Vt" 4' 6' to 12' CCA SS-L-30d Type VI Grade X DENS-COTE* PLASTER C 587 Brand- G-P G-P G-P Product JOINT SYSTEM MATERIALS METRO-MIXTM FORM BOARD ASTM* Standard* C 475 C 317 C 318 Federal Spec. SS-J-570a 10/24/66 SS-L-30d Type V--Grade R tStandard Length--Other Lengtha on Order. 'All ASTM Standard!--Per Lataat Revlaion. All Canadian Standarde In Blue Any questions not answered by the information on this page or available from local sources should be referred to Georgia-Pacific, Gypsum Division, 900 S.W. Fifth, Port land, Oregon 97204. CC CODE ACCEPTABILITY CERTIFICATION WARRANTY The assemblies and information in this brochure have been developed based on practical construction methods. However, since the Georgia-Pacific Gypsum Division does not have any prior knowledge of a specific building design and its construction or the methods of application used with its products, no warranty of performance is made. All tests have been obtained under controlled laboratory testing conditions where en vironmental variables are reduced to a minimum, in the field, such laboratory conditions are not always met, since many other variables may be produced. Laboratory results may exceed field test results but the laboratory tests under controlled conditions are the only logical way to compare the performance of different assemblies. The Gypsum Division of the Georgia-Pacific Corporation makes no warranty that the performance of assemblies in the field will have a performance equal to or better than that developed in the test. 35 SGP 0023671 DISTRIBUTION CENTERS United Statu ALABAMA Birmingham 3400 Ball St. (205} 041-0415 Huntsville 570 Highway 20 East Madison, Alabama (205) 772-0601 Mobil* 3451 Goorofa-Pacilic Ave (205) 479-0604 Montgomery 4542 Baldwin Ava. (205) 268-7200 ALASKA Fairbanks 272 Illinois St. (907) 452-2103 ARIZONA Phoenix 4001 Wait Collar St (602) 939-1413 Tucson 450 E. Irvington Rd. (602) 889-5701 ARKANSAS Ft. Smith 6901 Janny Lind Road (501) 646-4361 urn* Rock 3101 Dugan St. (SOI) 374-0212 Texarkana 3500 Tennessee load (501) 773-4616 CALIFORNIA Anaheim 1700 Lewis St. (714) 634-4641 Fresno 5288 East Home Ave. (209) ttl-6471 Lee Angeles 14750 Nelson Ave. City ot Industry (213) 966-5551 Oakland 2300 Poivorosa Ave San Leandro (415) 352-5100 Riverside 1450 Citrus Ave. (714) 684-5353 Sacramento 2951 Orange Grove Ave North Highlands (916) 481-4444 Salines 1031 industrial Ave. (408) 758-0913 San Diego 901 West 24th St. National City (714) 262-6955 San Fernando 7891 Deenng Ave Csnoga Park (213) 987-3211 San Jeoe 660 East Gish Rd. (406) 297-7S00 Santa Reas 3417 Standiah Road (707) 544-3040 COLORADO Denver 3900 Uvalde St. (303) 371-1500 CONNECTICUT Hartford 776 North Main St. Manchestar. Conn. (203) 646-8700 Wallingford 805 North Colony St (203) 260-8725 DELAWARE Wilmington Rlttenhouse Ind. Pk. Tormina) Ave & Christiana (302) 658-6203 FLORIDA Ft. Myers 3567 Work Drive (813) 332-3857 Jacksonville 1333 Hemet St. (904) 356-9711 Miami 3201 N.W. 110th St. (305) 688-6603 Orlande 2721 Reoent Ave. (305) 293-5761 4601 McCoy Dr. (904) 434-5501 Tallahassee 889 Mabry St. (904) 576-2148 Tamga 3701 East Columbus Dr. (613) 621-1351 West Palm Beach 900 West 15th Riviera Beach (305) 844-6371 QEOROIA Albany 1013 Worth St. (912) 432-5106 Atlanta 2351 Sutton Gwinnett Dr. Norcrosa, Ga (404) 449-7400 Augusta 1153 Gordon Highway (404) 724-0578 Columbus 1401 Blanchard Dr. (404) 327-6521 Meeen 7591 N E. Ind. Blvd. (912) 761-9700 Savannah Telfair Rd. and SCL Drive (912) 233-0071 IDAHO Boise 1675 Commercial Ava. (208) 345-6441 IOWA Dot Moines 5631 Northeast 17th St. (515) 265-5251 ILLINOIS Chicago 10450 Wave! and Ave. Franklin Park (312) 678-2990 17040 Lathrop Ave. Harvey (312) 928-3338 Bloomington 422 White Oak Rd. Normal. Illinois (309) 452-9422 Quad Cities 300 East Fourth Ava Milan, III. (309) 787-6121 INDIANA Elkhart 225 Collins Rd. (219) 294-5481 Evansville 520 North Congress Ave. (812) 477-8123 Fort Wayne 6620 Biuffton Road (219) 747-1691 Indianapolis 1477 South Franklin Road (317) 357-8754 KANSAS Wichita 401 West 47th St. South (316) 522-4831 KENTUCKY Louisville 2716 Grassland Drive (502) 491-5440 LOUISIANA tBoaitol nLeReoauvgileie St. (504) 343-7461 Lafayette 814 S. W. Evangeline Thruway (318) 232-2551 New Ortaana 7500 Almonaster Ave. (504) 241-2380 Shreveport 2801 Valley View Or. (318) 688-8771 MAINE Bennott St & Hildreth (207) 947-0142 Portland 508 Warren Ave. (207) 797-6564 MARYLAND Bottlmore 6613 Quad Ave. (301) 285-4700 Salisbury Armstrong Parkway & Marvel Rd. (301) 546-2181 MASSACHUSETTS Beaton 250 Ballardvale St. Wilmington (617) 444-6300 Springflold 121 Memorial Drive Memorial Ind. Park (413) 781-7030 MICHIGAN Detroit 11800 Sears Ind. Dr. Livonia (313) S22-5100 Grand Rapids 825 Buchanan Ava., S.W. (616) 241-1628 Saginaw 3720 E Wash. Rd. (517) 752-8134 MINNESOTA Minneapolis 6175 County Line Rd 16 (612) 425-6811 MISSISSIPPI Jackson 555 Gulf Lino Rd. (601) 939-6420 MISSOURI Capo Girardeau Nash Road (314) 334-0533 Kansas City 1445 Tansy St. North Kansas City (816) 642-3366 St. Louie 6025 Byassee Dr. Hazelwood (314) 731-0161 Springfield 3220 East Cherry St. (417) 669-1641 MONTANA Billings 600 Daniel St. (406) 245-3136 Greet Fell* 901 River Drive S (406) 453-5471 NEBRASKA Lincoln 545 "L" St. (402) 432-7525 NEW HAMPSHIRE Manchester 300 Gay St (603) 627-3661 NEW JERSEY Clifton 400 Ailwood Rd. (201) 773-1000 Trenton 530 U S. Route *130 Vardviiie (606) 565-1100 NEW Mexico Albuouorgue 1820 BeHameh N.W. (505) 242-2791 NEW YORK Albany Brown and Ind. Rds. (516) 459-8060 Binghamton Broome Ind. Pk. Kirkwood (607) 775-1120 Buffalo 2585 Weldon Ave. (716) 685-2323 Nassau 175 Underhill Blvd. Syosaet (516) 921-7200 New York City 1 Hudson River Dr Croton-on-Hudson (914) 271-8201 Rochester 1460 East Hanriatta Rd. (716) 442-1600 Suffolk Yaphank Ava and Park St. Yaphank (516) 924-7400 Syracuse Midler Park Or. (315) 437-1201 NORTH CAROLINA. Asheville Rout* *2. Azalea Road (704) 298-5274 Charlotte 3300 Parkside Dr. (704) 394-3171 Greensboro 3005 Flagstone Or. (919) 27S-9431 Raleigh 3501 Tarheel Dr. (919) 876-4430 Wilmington 319 Marlboro St (919) 799-5200 OHIO Akron 2644 Gilchrist Rd. (216) 794-1140 Cincinnati 4710 Dues Or (513) 874-4123 Cleveland 19100 Holland Rd. (216) 234-1376 Columbus 2100 Refuges Rd. (614) 445-8256 Dayton 5150 Webster St. (513) 276-5986 Toledo 2815 Hill Ave (419) 536-3721 OKLAHOMA Oklahoma City 5519 N W. Fourth St (405) 946-0737 Tutaa 5717 North Mingo (918) 272-2211 OREGON Eugene 3445 W 1st Ave. (503) 345-4358 Portland 10515 S W. Alton Avenue Beaverton (503) 643-8611 PENNSYLVANIA Lancaster 3639 Hemptield industrial Park (717) 285-4544 Philadelphia 601 First Ave King of Prussia (215) 265-4600 Pittsburgh Hunker Rd. and Rt 119 New Stanton (412) 242-9100 Scranton 150 PiltSton Ave Yateaviiie-Pittston (717) 855-2901 RHODE ISLAND Providence 170 Jeflerson Blvd Warwick (401) 463-7700 SOUTH CAROLINA Charleston Bennett Ind. Park (603) 554-8191 Columbia 855 Brookwood Dr. (803) 771-7740 Greenville Hayward Road (803) 288-2020 TENNESSEE Bristol 100 Paty Indus Blvd (615) 966-4121 Chattanooga 201 East 28th St. (615) 696-8076 Knoxville 1301 Mitchell St , N E (615) 546-4441 Memphis 4287 Pilot Dr. (901) 365-2100 Nashville 331 26th Ave . N (615) 383-7160 TEXAS Amarillo 80 Lakeside Dnve (806) 372-5706 Austin 2416 East Sixth St (512) 478-7406 Beaumont 6550 Oakcrest Drive (713) 692-6720 Corpus Christ! 230 Omaha Dr. (512) 884-3231 Oellea 1800 John Connally Dr. Carrollton (214) 242-4251 El Paso 6990 Market St. (915) 776-6353 Fort Worth 4747 Mark IV Parkway (817) 625-2351 Houston 650 Gsllhorn Dr. (713) 675-1721 Lubbock 702 East 44th St. (806) 747-3626 San Antonio 535 North W W White Rd (512) 333-6110 Tyler 8th Street $ Lswhon Ave. Owentown (214) 877-3181 UTAH Salt Lake City 2875 S. 300 W. (601) 486-9261 VERMONT Burlington Pmo Haven Shore Road Shelburne. Vt. (602) 965-2511 VIRGINIA Graves Mil! Rd Timberlake (804) 239-9241 Norfolk 200 Price St. Virginia Beach (804) 499-5981 Richmond Corner Dabney 6 Bethlehem Rds (804) 355-9167 WASHINGTON 829 Cornwall Avenue (206) 733-6000 Seattle 12615 N E. 176th St Woodinvilie (206) 466-0741 Spokane 6815 E Misson (509) 926-3030 Tacoma 2302 Ross Way (206) 383-4576 WASHINGTON, D.C. Washington, D.C. 8121 Ardwick-Ardmore Road Landover. Maryland (301) 322-2270 Waat Washington, D.C. 11800 Belts Ford Rd. Manaaaaa. Virginia (703) 361-5147 WEST VIRGINIA Charleston Rock Branch Ind. Pk. Poca, W. va. (304) 755-8153 WISCONSIN Madison 703 Mayfair Ave. (608) 241-3874 Milwaukee 5059 North 119 i St (414) 484-7900 Wausau 809 S 62nd Ave. (715) 842-0651 Canadian Branch** Georgia-Pacific Building Materials, LTO. Calgary 8209-30th St S.E. Calgary Alberta (403) 279-4438 London 100 Themes Street North ingersoli. Ontario, (519) 485-4431 Montreal 4650 Notre Dame St. East Montreal. Quebec (514) 253-0300 Quebec City P.0 Box 15250 Postal Terminal Quebec City. Quebec (416) 692-2671 Toronto 173 Carrier Drive Rexdaie. Ontario (416) 745-2444 Vancouver 916 River Dr. Richmond. B.C. 1604) 273-7621 Winnipeg 1500 Clarence Avenue Winnipeg, Manitoba (204) 453-9027 GYPSUM/SALES OFFICES CALIFORNIA F.O. Bex 24373 Oakland 418/383-8180 DELAWARE Wilmington Marine Terminal F.O. Box 310 Wilmington 302/888-7221 GEORGIA 128 Ottley Drive N.E. P.O. Box 13SOS SIS. K. Atlanta--404 / 873-8361 ILLINOIS 10480 Weveland Ave. Franklin Fork--312/87*4888 TEXAS 1800 John Connelly Drive Carrollton--214/242-4211 WASHINGTON, D.C. 121 Artfwfck-Ardmore Road F.O. Bex 14SS Landover, Md.--301/773-3320 SGP 0023672 GYPSUM EXPORT DEPT. PENNSYLVANIA ISOS Raca St Philadelphia. Pa.--21S/SSS-7S11