Document pmR93mx419070bek27jE8rDra

PLAINTIFF'S EXHIBIT INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/27/78__________ BUILDING NAME Main Lab BLDG. NUMBER 422 UNIT IN WHICH BLDG. LOCATED Main Office HOOD TYPE slot HOOD LOCATION Bottle Wash RoomMATERIAL EXHAUSTED Acids, Esters Ketones, etc. OVERALL HOOD DIMENSIONS (INCHES): LENGTH HEIGHT -- WIDTH -- DEPTH -- FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS --FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT ~~ WIDTH -- FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM 40 AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM 2000___________ ^ FACE VELOCITY AT NORMAL WORKING POSITION IN FPM HEIGHT ~~ WIDTH ~~ PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION ~~________________________________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION 26 AREA 1.25 SQUARE FEET VELOCITY 2000 FPM VOLUME 2500 CUBIC FEET PER MIN (Q VA) Q VOLUME V VELOCITY A AREA FAN TYPE Centrifugal____________ FAN SIZE BVF-150 CFM MOTOR HORSEPOWER 1.5____________ RPM ____ REMARKS: Excellent capture velocity, solved the problems in the bottle wash room. es BRE 0119 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78 BUILDING NAME Main Lab BLDG. NUMBER 422 UNIT IN WHICH BLDG. LOCATED . Main Office HOOD TYPE Vent ___________________________________________ to HOOD LOCATION Solutions RoomMATERIAL EXHAUSTED SOg, Pyriden, Acids, etc. OVERALL HOOD DIMENSIONS (INCHES): LENGTH HEIGHT 59 WIDTH 39 DEPTH 28 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 25FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT /MIN: HEIGHT 24" WIDTH - 39 FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM ~~ AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM "_________ _ FACE VELOCITY AT NORMAL WORKING POSITION IN FPM 100 HEIGHT 24 ^ WIDTH 39 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Average Reading___________________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION -- AREA 6,.5 . SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 100 FPM VOLUME 650 V VELOCITY A AREA CFM * FAN TYPE Squirrel Cage FAN SIZE MOTOR HORSEPOWER _________ RPM BRE 0120 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION BATE 10/30/78 BUILDING NAME Main Lab BLDG. NUMBER 422 UNIT IN WHICH BLDG. LOCATED Main Office- HOOD TYPE Vent HOOD LOCATION VFA Room MATERIAL EXHAUSTED Acids. Esters-. Ketones, etc. OVERALL HOOD DIMENSIONS (INCHES): LENGTH -- HEIGHT 29 WIDTH 23 DEPTH 21 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 25FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT 9" WIDTH 23 FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM _________ " AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM " FACE VELOCITY AT NORMAL WORKING POSITION IN FPM 25 HEIGHT 29 WIDTH 23 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Average Reading_____________________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION ~ AREA 4-632 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 25 FPM VOLUME U6 CFM V VELOCITY A AREA FAN TYPE Squirrel Cage FAN SIZE _ MOTOR HORSEPOWER __________________ RPM___ ___________________________________ REMARKS: This hood normally handles only small amounts of contaminants BRE 0121 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION L, DATE 0/27/78 BUILDING NAME Main Lab BLDG. NUMBER 422 UNIT IN WHICH BLDG. LOCATED Main Office______________________ HOOD TYPE Canppy HOOD LOCATION AA Mini-labMATERIAL EXHAUSTED Combustion Products OVERALL HOOD DIMENSIONS (INCHES): LENGTH 12 HEIGHT -- WIDTH 12 DEPTH -- FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 350FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT -- WIDTH -- FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM ~__________________________ AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM -- FACE VELOCITY AT NORMAL WORKING POSITION IN FPM 30 HEIGHT 11" WIDTH -- PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION _________________ Avg. Reading________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION 1 -- i t AREA 1.0 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 350 . FPM VOLUME 350 CFM V VELOCITY A AREA FAN TYPE Centrifugal____________ FAN SIZE MOTOR HORSEPOWER ___________ RPM BRE 0122 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/27/78___________ BUILDING NAME Main Lab BLDG. NUMBER 422 UNIT IN WHICH BLDG. LOCATED Main Office HOOD TYPE Vent, Compensating HOOD LOCATION _______A .A. Mini Lab MATERIAL EXHAUSTED Acids, Esters, Ketones, etc. OVERALL HOOD DIMENSIONS (INCHES): LENGTH -- HEIGHT 26 WIDTH 40 DEPTH 28 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 300FT /MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT 26 WIDTH 40 FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM " AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM ~~ FACE VELOCITY AT NORMAL WORKING POSITION IN FPM 300 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION HEIGHT 2(> WIDTH 4 Average Reading______________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION ___________ " area 7,22 SQUARE FEET VELOCITY 300 FPM l VOLUME 2166 CFM CUBIC FEET PER MIN (Q VA) Q VOLUME V VELOCITY A AREA FAN TYPE Centrifugal_________ FAN SIZE MOTOR HORSEPOWER RPM REMARKS: Inner door must be in top position for good flows, or air will bypass directly to fan and fumes will back up into worker's breathing zone. BRE 0123 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/27/78 BUILDING NAME Main Lab UNIT IN WHICH BLDG. LOCATED _______ Main Office BLDG. NUMBER 422 HOOD TYPE Vent Compensating HOOD LOCATION E.P. Mini-lab MATERIAL EXHAUSTED Misc. Reagents OVERALL HOOD DIMENSIONS (INCHES): LENGTH -- HEIGHT 26 WIDTH 40____ DEPTH FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 300 ______FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT 26 WIDTH 40 FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM ____ ] FACE VELOCITY AT NORMAL WORKING POSITION IN FPM 300 HEIGHT 26 WIDTH 40 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Average Reading FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION AREA 7.22 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 300 FPM VOLUME 2166 V VELOCITY A AREA CFM FAN TYPE Centrifugal FAN SIZE MOTOR HORSEPOWER RPM REMARKS: Inner door must be in top position for good flows, or air will bypass directly to exhaust fan and fumes will back up into worker's breathing zone. BRE 0124 i) INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE LQ/30/78 BUILDING NAME Main Lab BLDG. NUMBER 422 UNIT IN WHICH BLDG. LOCATED Main Office HOOD TYPE Vent HOOD LOCATION Chemicals Bench, West Side MATERIAL EXHAUSTED Acids, Esters, Ketones, etc. OVERALL HOOD DIMENSIONS (INCHES): LENGTH " HEIGHT 28 WIDTH 42 DEPTH 27 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 200FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT 28 WIDTH 42 FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM _____________ _______________ AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM " FACE VELOCITY AT NORMAL WORKING POSITION IN FPM * 200 HEIGHT 2? WIDTH 42 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Average Reading FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION 21 AREA 8.167 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 200 FPM VOLUME 1633 V VELOCITY A AREA CFM FAN TYPE Disc_______________ FAN SIZE MOTOR HORSEPOWER RPM ~1 i ; 1 REMARKS: * Flow is aided by draft from air conditioner vent. 5 BRE 0125 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78 BUILDING NAME UNIT IN WHICH BLDG. LOCATED Main Office HOOD LOCATION Chemicals Bench, East Side Main Lab BLDG. NUMBER HOOD TYPE Vent MATERIAL EXHAUSTED Acids, Esters, Ketones, etc. OVERALL HOOD DIMENSIONS (INCHES): LENGTH -- HEIGHT 28 WIDTH 42 DEPTH 27 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 125"FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT 28 WIDTH 42 FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM _________ -- AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM -- FACE VELOCITY AT NORMAL WORKING POSITION IN FPM * 225 HEIGHT 2gWIDTH 42 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Average Reading_____________________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION -- % AREA 8.167 SQUARE FEET VELOCITY 125 FPM VOLUME 1021 CFM CUBIC FEET PER MIN (Q VA) Q VOLUME V VELOCITY A AREA FAN TYPE Centrifugal_________ FAN SIZE MOTOR HORSEPOWER RPM REMARKS: * Flow is aided by draft from air conditioner vent. BRE 0126 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78 BUILDING NAME Main Lab UNIT IN WHICH BLDG. LOCATED Main Office HOOD TYPE BLDG. NUMBER Vent 422 HOOD LOCATION Southwest Side of Lab MATERIAL EXHAUSTED Acids. Ketones , Steam, etc. OVERALL HOOD DIMENSIONS (INCHES): LENGTH -- HEIGHT ' 28.5 WIDTH 41.5 DEPTH 26.5 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 50" FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT 17" WIDTH 41.5 FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM -- _________ AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM -- FACE VELOCITY AT NORMAL WORKING POSITION IN FPM * 100 I[EIGHT 17. WIDTH 41.5 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION _________ Lrpraop. Rp.atHnff____________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM.THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION " AREA 4.9 SQUARE FEET CUBIC FEET PER MIN (Q VA) VELOCITY Q VOLUME 100 V FPM VOLUME VELOCITY 'A I 490 AREA CFM FAN TYPEFAN SIZE _____ MOTOR HORSEPOWER RPM BRE 0127 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78__________ BUILDING NAME Main Lab BLDG. NUMBER 422 , UNIT IN WHICH BLDG. LOCATED Main Office H00D TYPE Vent_________________________________________________ HOOD LOCATION Southeast Side of LabMATERIAL EXHAUSTED Acids, Esters, Ketones, etc. OVERALL HOOD DIMENSIONS (INCHES): LENGTH ' " HEIGHT 59 WIDTH 40 DEPTH 28 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS * 60FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT 24" WIDTH 40 (, FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM ~ AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM________ "__________ FACE VELOCITY AT NORMAL WORKING POSITION IN FPM * 100 HEIGHT 24 WIDTH 40 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Average Reading_____________________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION -- AREA 6.67 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 100 FPM VOLUME 667 V VELOCITY A AREA CFM FAN TYPE :_____________________________ FAN SIZE MOTOR HORSEPOWER . RPM_______________________________________________ _________ 2 doors + OH venjt open =25 ft/min; 2 doors open, OH vent closed = 50 ft/min * 1 door open = 60 ft/min I i ! i REMARKS: * There are 3 hoods in this system. These measurements were made with the other 2 hoods closed. BRE 0128 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78 BUILDING NAME Main Lab_______________________________________ BLDG. NUMBER 422 UNIT IN WHICH BLDG. LOCATED Main Office HOOD TYPE Vent HOOD LOCATION Distillation BenchMATERIAL EXHAUSTED Acids. Ketones, Esters, etc. OVERALL HOOD DIMENSIONS (INCHES): LENGTH -- HEIGHT 90 WIDTH 47.5 DEPTH 24 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS ________ "___________ FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT -- WIDTH -- FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM -- AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM "___________ DEPTH FACE VELOCITY AT NORMAL WORKING POSITION IN FPM * 100 fBSg 24 WIDTH 47,5 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Average Reading FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION " AREA 7.917 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME FAN TYPE FAN SIZE 100 FPM VOLUME 792 V VELOCITY A AREA CFM MOTOR HORSEPOWER _____ RPM _____ REMARKS: * Doors are all closed in normal operating condition. Flow measurement was made in a horizontal plane inside the enclosure at about raid height. Doors were closed on the other 2 hoods in this 3-hood system. BRE 0129 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78 BUILDING NAME UNIT IN WHICH BLDG. LOCATED . Main Office HOOD LOCATION E.P. Bench Southwest OVERALL HOOD DIMENSIONS (INCHES): LENGTH Main Lab BLDG. NUMBER 422 HOOD TYPE Vent MATERIAL EXHAUSTED Acids HEIGHT 29 WIDTH 41.5 DEPTH 2.7 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 50 ________ FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT 15" WIDTH 41.5 FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM --____ AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM FACE VELOCITY AT NORMAL WORKING POSITION IN FPM 100 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION HEIGHT 15" WIDTH 41 *5 Average Reading FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION ____________ ____________ AREA 8.358 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 50 FPM VOLUME 418 V VELOCITY A AREA CFM FAN TYPE Squirrel Cage FAN SIZE MOTOR HORSEPOWER RPM ______ REMARKS: BRE 0130 G INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78 BUILDING NAME Main Lab BLDG. NUMBER 422 UNIT IN WHICH BLDG. LOCATED Main Office HOOD TYPE Slot/Booth HOOD LOCATION E.P. Bench Steam Bath MATERIAL EXHAUSTED Steam, Solvents, AcgQ OVERALL HOOD DIMENSIONS (INCHES) : LENGTH 22 HEIGHT " WIDTH 15 DEPTH " FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 150FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT -- WIDTH ~~ FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM6^ AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM 1000 with doors closed FACE VELOCITY AT NORMAL WORKING POSITION IN FPM -- HEIGHT WIDTH ________ " PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Average Reading__________________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION Inside Slot AREA 0.229 SQUARE FEET VELOCITY 1000 FPM VOLUME ' 229 CUBIC FEET PER MIN (Q VA) Q VOLUME V VELOCITY A AREA CFM FAN TYPE Squirrel Cage_________ FAN SIZE MOTOR HORSEPOWER ________________ RPM REMARKS: & BRE 0131 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78________ BUILDING NAME Control Room BLDG. NUMBER 522 UNIT IN WHICH BLDG. LOCATED Recovery HOOD TYPE Vent, Compensating HOOD LOCATION Recovery Lab MATERIAL EXHAUSTED Acids^ Esters. Ketones, etc. OVERALL HOOD DIMENSIONS (INCHES): LENGTH -- HEIGHT 26 WIDTH 38.5 DEPTH 23 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 150FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT f 26 WIDTH 38.5 FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM ___________-- AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM -- FACE VELOCITY AT NORMAL WORKING POSITION IN FPM 150 HEIGHT 26 WIDTH 38.5 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Average Reading FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION " AREA 6.951 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME ^ FAN TYPE Centrifugal___________ FAN SIZE 150 FPM VOLUME 1043 V VELOCITY A AREA CFM MOTOR HORSEPOWER _________________ RPM ______ ___________________ REMARKS: This hood has two blowers, but it seems that only one is working; it should be, inspected by electricians. BRE 0132 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78_________ BUILDING NAME Control Room _______________ BLDG. NUMBER 731 UNIT IN WHICH BLDG. LOCATED Reaction #1 HOOD TYPE Slot/Booth HOOD LOCATION _______ Reaction #1 LabMATERIAL EXHAUSTED Acids, Butane, etc. OVERALL HOOD DIMENSIONS (INCHES): LENGTH 29 HEIGHT 18 WIDTH -- DEPTH 11.5 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS ________ ~__________ FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT -- WIDTH -- FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM Edge of Sink AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM 900 FACE VELOCITY AT NORMAL WORKING POSITION IN FPM 170 HEIGHT WIDTH -- PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION ________ Avg. Reading________________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION 18 AREA 2.417 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 170 FPM VOLUME 411 CFM V VELOCITY A AREA FAN TYPE Squirrel Cage FAN SIZE MOTOR HORSEPOWER RPM REMARKS: BRE 0133 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78 BUILDING NAME Control Room BLDG. NUMBER 821 UNIT IN WHICH BLDG. LOCATED Reaction #2 HOOD TYPE Slot/Booth _____________________________________ _ HOOD LOCATION Reaction #2 Lab MATERIAL EXHAUSTED AcOH, Butane, etc. OVERALL HOOD DIMENSIONS (INCHES): LENGTH 33 HEIGHT 18 WIDTH -- DEPTH 10 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 60FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT -- WIDTH --________ ( FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM __________________ -- AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM 250 FACE VELOCITY AT NORMAL WORKING POSITION IN FPM 60* HEIGHT PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Avg. Reading WIDTH -- FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION 14 AREA 3.438 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME | FAN TYPE Squirrel Cage FAN SIZE 250 FPM VOLUME 860 CFM V VELOCITY A AREA MOTOR HORSEPOWER _________________ RPM _____ ________ REMARKS: * Low flow BRE 0134 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78________ BUILDING NAME Carpenter Shop BLDG. NUMBER 16^ UNIT IN WHICH BLDG. LOCATED Maintenance HOOD TYPE Vacuum Canister HOOD LOCATION Radial Arm SawMATERIAL EXHAUSTED Dust Collection OVERALL HOOD DIMENSIONS (INCHES): LENGTH HEIGHT WIDTH DEPTH FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT /MIN: HEIGHT WIDTH FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM FACE VELOCITY AT NORMAL WORKING POSITION IN FPM HEIGHT `WIDTH PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION _________________________________________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION AREA SQUARE FEET VELOCITY FPM VOLUME CFM CUBIC FEET PER MIN (Q VA) Q VOLUME V VELOCITY FAN TYPE FAN SIZE MOTOR HORSEPOWER_________________ RPM A AREA REMARKS: Keeps the fine dust particles away from the workers BRE 0135 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78________________ BUILDING NAME Machine Shop BLDG. NUMBER 424 UNIT IN WHICH BLDG. LOCATED Maintenance HOOD TYPE Vent HOOD LOCATION DeZurik Valve Room MATERIAL EXHAUSTED Chlorothane OVERALL HOOD DIMENSIONS (INCHES): LENGTH ~~ HEIGHT 185 WIDTH 44 DEPTH 24.5 DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT 18 5 WIDTH 44 FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM --_____________________ f. AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM -- FACE VELOCITY AT NORMAL WORKING POSITION IN FPM 150 HEIGHT 18.5 WIDTH 44 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Avg. liendiru. > FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION ' _______________ AREA 5.653 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 150 FPM VOLUME 850 V VELOCITY A AREA FAN TYPEDisc___________________________ FAN SIZE GFM MOTOR HORSEPOWERRPM REMARKS: BRE 0136 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78___________ BUILDING NAME PRV Room BLDG. NUMBER 424 UNIT IN WHICH BLDG. LOCATED Maintenance HOOD TYPE Vent/Booth HOOD LOCATION PRV RoomMATERIAL EXHAUSTED Paint Fumes OVERALL HOOD DIMENSIONS (INCHES): LENGTH " HEIGHT 29.5 WIDTH 30 DEPTH 30 FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS 180FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT -- WIDTH * ~ FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM 21 AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM ~~ FACE VELOCITY AT NORMAL WORKING POSITION IN FPM * 180 HEIGHT 29.5 WIDTH 30 PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION _________ Avg. Reading_______________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION ___________^ AREA 5.15. SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 180 FPM VOLUME 1107 CFM V VELOCITY A AREA FAN TYPE Squirrel Cage FAN SIZE MOTOR HORSEPOWER ._________________ RPM REMARKS: * Very Good Flow BRE 0137 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78__________ BUILDING NAME Welding Shop BLDG. NUMBER 42^ UNIT IN WHICH BLDG. LOCATED Maintenance HOOD TYPE Cone _____________________________________________ HOOD LOCATION Southeast of ShopMATERIAL EXHAUSTED Welding Fumes OVERALL HOOD DIMENSIONS (INCHES): LENGTH 8.5 HEIGHT 85 WIDTH 8-5 DEPTH ~~ FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS ________ "__________ FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT ~~ WIDTH ________ " FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM -- AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM 1000 ; FACE VELOCITY AT NORMAL WORKING POSITION IN FPM HEIGHT 'WIDTH PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Avg. Reading at Opening________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION 6-9 AREA 0.394 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 1000 FPM VOLUME 394CFM V VELOCITY A AREA g FAN TYPE Squirrel Cage________ FAN SIZE MOTOR HORSEPOWER RPM REMARKS: BRE 0138 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78_________ BUILDING NAME Welding Shop BLDG. NUMBER 424 UNIT IN WHICH BLDG. LOCATED Maintenance H00D TYPE Cone HOOD LOCATION Southwest of Shop MATERIAL EXHAUSTED Welding Fumes OVERALL HOOD DIMENSIONS (INCHES): LENGTH 8.5 HEIGHT 8.5 WIDTH 8.5 DEPTH -- FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT -- WIDTH -- FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM _______________ ____________ AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM 1500 FACE VELOCITY AT NORMAL WORKING POSITION IN FPM _______ -- HEIGHT WIDTH ~~ PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Avg. Reading at Opening______________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION 6-9 AREA 0394 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 1500 PPM VOLUME 591 CFM V VELOCITY A AREA FAN TYPE Squirrel Cage_______ fan SIZE MOTOR HORSEPOWERRPM REMARKS: BRE 0139 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78__________ BUILDING NAME Welding Shop BLDG. NUMBER UNIT IN WHICH BLDG. LOCATED Maintenance HOOD TYPE Cone ____________________________________________ HOOD LOCATION Northeast of Shop MATERIAL EXHAUSTED Welding Fumes OVERALL HOOD DIMENSIONS (INCHES): LENGTH 85 HEIGHT 8'5 WIDTH 8'5 DEPTH ~~ FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS ________ "__________FT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT ~~ WIDTH ~~ FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM"__________________________ AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM 1000 FACE VELOCITY AT NORMAL WORKING POSITION IN FPM ~~ PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION HEIGHT WIDTH Avg. Reading at Opening_____________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION 6-9 AREA 0.394 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 1000 FPM VOLUME 394 V VELOCITY A AREA i FAN TYPE Squirrel Cage FAN SIZE CFH MOTOR HORSEPOWER __________________ RPM _____ REMARKS: BRE 0140 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION DATE 10/30/78 BUILDING NAME Insulation Shop U5BLDG. NUMBER UNIT IN WHICH BLDG. LOCATED HOOD TYPE Slot HOOD LOCATION Band Saw **. OVERALL HOOD DIMENSIONS (INCHES): LENGTH MATERIAL EXHAUSTED Insulation Dust -- HEIGHT WIDTH -- DEPTH FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS JFT/MIN. DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT WIDTH FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE VELOCITY IS 100 FPM ""___________ AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM * 5000 FACE VELOCITY AT NORMAL WORKING POSITION IN FPM ~~ HEIGHT WIDTH PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION Avg. Reading_____________________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION "" _____ AREA 0.087 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 5000 FPM VOLUME 434 CFM V VELOCITY A AREA FAN TYPE ________________________ FAN SIZE _________ MOTOR HORSEPOWER** RPM 1200 Avg. both bench vents on;2500 Avg. one on 5000+ both off ** 2 slots 2" X 1" Top and 3" X 3.5" Bottom REMARKS: * This is a 3-hood system. Measurements were made with only one open. Opening another cuts flow in half. C BRE 0141 INDUSTRIAL HYGIENE EVALUATION AND SURVEY - VENTILATION E DATE 10/30/78 BUILDING NAME Insulation Shop BLDG. NUMBER A3.5T U UNIT IN WHICH BLDG. LOCATED Maintenance __________________ HOOD TYPE Slot/Booth I HOOD LOCATION North SideMATERIAL EXHAUSTED Insulation Dust OPENINGS c OVERALL HOOD DIMENSIONS (INCHES): LENGTH -- HEIGHT 5.5 WIDTH 11 XSEEEB 8 I FACE VELOCITY WITH DOOR(S) WIDE OPEN AT ABOVE DIMENSIONS ______________ FT/MIN. E DOOR OPENING IN INCHES AT WHICH FACE VELOCITY IS 100 FT/MIN: HEIGHT . WIDTH --________ I FOR SLOT HOODS THIS MEASUREMENT WOULD BE THE DISTANCE FROM THE SLOT IN INCHES WHERE CAPTURE V VELOCITY IS 100 FPM _________ " A AVERAGE SLOT VELOCITY AT THE SLOT OPENING IN FPM* 1000_____________ _ F FACE VELOCITY AT NORMAL WORKING POSITION IN FPM ~~ HEIGHT __________WIDTH " E PROBE HEIGHT FROM HOOD BASE FOR NORMAL WORKING POSITION _________ Avg. Reading__________________________ FOR SLOT HOODS THIS IS THE DISTANCE IN INCHES FROM THE SLOT TO EDGE OF THE SOURCE FOR NORMAL WORKING POSITION ___________ " AREA 5.361 SQUARE FEET VELOCITY CUBIC FEET PER MIN (Q VA) Q VOLUME 1000 FPM VOLUME 3361 V VELOCITY A AREA CFM I FAN TYPE ____________ .___________ FAN SIZE N MOTOR HORSEPOWER ___________ RPM O t> rtg I REMARKS : _____________________ * This is a 3-hood system. Measurements were made with only one open. Opening 2 cuts flow in half. BRE 0142 I INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION CHEMICALS AND PLASTICS P. O. BOX 3370, BROWNSVILLE, TEXAS 78520 To (Name) Company Location Mr. K. G. Townsend Brownsville Plant Copy to Date November 2, 1978 Originating Dept. Answering letter date Subject Ventilation Survey The semi-annual Industrial Hygiene Survey of ventilation equipment at the Brownsville plant has been completed. Flow measurements and eval uations were performed on 21 fume hoods and two dust collectors. Their locations in the plant are as follows: Laboratory Recovery Lab Reaction #1 Lab Reaction #2 Lab Carpenter Shop Machine Shop Welding Shop Insulation Shop 13 1 1 1 1 (Dust Collector) 2 3 1 (Dust Collector) Several points of interest were noted during the survey: 1. The laboratory made several improvements since the last survey. A. A new hood was installed over the bottlewashers sink. It has excellent flows, 150 FPM at edge of sink and 100 FPM out to 40 inches, and 2000 FPM at each of the six slots for a total of 2500 CFM of flow. The only minor problem found is that when chemicals are poured into sink, some fumes back up through the drain of the next sink, but this could be remedied by installing a trap under the sink. B. The old E.P., A.A. bench hood (now E.P.,I.H.) was relieved of most of its use, since the A.A. instrument was moved to the mini-lab, and its infrequent use and small amounts of chemicals required does not create a significant problem. C. The chemicals bench east side hood was improved by the simple expedient of turning the air conditioning vent to blow directly at its door and it now has 125 FPM with the door wide open. However the old problem of not being able to close the door, in case of major spill, still exists and should be corrected. BRE 0117 Mr. Townsend -2 November 2, 1978 D. The steam bath hood no longer has a branch leading to the A.A. instrument, but the branch was left open and should be capped. 2. Recovery Lab - This hood is of the compensating type, but nff air was detected coming in between the door and front baffle. It is possible that the outside air intake is closed, or if equipped with inblowing motor, that it is not operating. The exhaust flows are still good (150 FPM) but it probably puts a strain on the air con ditioning system and could even create a negative pressure inside the lab. 3. Reaction #1 Lab - No problems. 4. Reaction #2 Lab - Low flows and poor ventilation, engineering is working on improvements. ^ 5. Carpenter Shop - Same problem as before, the poor location of the radial arm saw (in front of I-beam) makes it difficult for the saw dust to fall down into the box and it blows back to the operator instead. 6. Machine Shop - No problems. 7. Welding Shop - No problems. 8. Insulation Shop - This dust collector has three branches, two on workbenches and one for the band saw, and the flows are very good even with all branches open, but the noise problem it creates ( ;> 90 dB(A))may induce some workers not to turn it on when needed. Please see the individual hood evaluation sheets for further details. MG:mfw