Document pmLbVd1wq7wKQYp71eoobyVad

60 CHAPTER 4 1962 Guide And Data Book above which no heat is required by the structure) from Fig 12 at the intersection of the day heat loss line and the sero load line. 3. Determine the Balance Point Temperatures for the calculated day and night heat losses and the system capacity. These tern- Citurea are obtained from Fig. 12 at the intersection of the t loss and system capacity lines. 4. Obtain the average outdoor temperature and hours of occurrence below the chemgeoocr temperature by tabulating the weather data in the form given by Table !. The day and night structure heat loss, as well as the system heating capacity at this average outdoor temperature, can then be obtained from Fig. 12. Also, it will be necessary to obtain, from manufacturer's data, the kilowatt demand of the compressor and the heat-source, heat sink auxiliary equipment, such as outdoor coQ fans or deep well pumpe, at the average outdoor temperature. The kilowatt-hours of the compressor-outdoor fan combination below the changeover temperature is, therefore, the product of (structure heat loss times the hours of occurrence divided by the system heating capacity) and (the kilowatt demand of com pressor-outdoor fan combination) at the average outdoor tem perature below the changeover temperature. 5. Obtain the average outdoor temperature and hours of occur rence below the balance point by tabulating the weather data in the form given by Table 1. The day and night structure heat losses, as well as the system heating capacity at the average temperature below the balance point, can then be obtained from Fig. 12. The amount of supplemental or booker heat required (indi cated by the crosshatch lines on Fig. 12) is then the product of (the difference between the structure heat loss and the system heating capacity) and (the hours of occurrence) at the average outdoor temperature below the balance point. 6. The heating kilowatt-hours for the day and night periods are the sum of the compressor-outdoor fan kilowatt-nours from step 4 and the booster heat kilowatt-hours from step 5. 7. The total heating kilowatt-hours is the sum of the day and night kilowatt-hours in stop 6. An example of this procedure is given in Table 3, with calcu lations of the energy requirements for heating in the month of January. Calculations should be made for all other months and the data recorded in the form of Table 2. Cooling 8. Calculate the day and night heat gain in the form given by Fig. .IS. These heat gains include the transmission, solar, internal ventilation or infiltration air, as Hiwniaawd in the section Heating and Cooling Load Estimates. The system cooling capacities, at various outdoor temperatures, are obtained from the manu facturer's published data. 2. Determine the outdoor temperature range corresponding to each of tho four steps of compressor capacity, from curves such as Fig. 13, for the day and night cycle. Tne approximate range for the day cycle is: 54 F or below, use outdoor air 55-59 F, use % capacity 60-74 F, use H capacity 75-84 F, use capacity 85 F and above, use full capacity The approximate range for the night cycle is: 75-84 F, use % capacity 85-95 F, use capacity 10. Obtain the number of hours at the four ranges of outdoor temperature (corresponding to the four steps of capacity modula tion) given by step 9. These operating hours can be compiled from weather bureau data for each of the cooling mnn^hp illustrated by Table 1 for the month of July. 11. The oooling requirement, in ton-hours, for each of the four steps of capacity, is the product of the (hours of occurrence, from step 10) and (system capacity, in tons). 12. The kilowatt-hours for each of the four steps of capacity are products of the (ton-hours, from step 11) and (the kilowatts per ton-hour, from manufacturer's data). 13. The total cooling kilowatt-hours for the day and night periods are the sum of the kilowatt-hours for the four capacity steps of step 12. 14. The grand total cooling kilowatt-hours for the month is the sum of the day and night kilowatt-hours from step 13. Table 3 . . . . Example of Procedure for Calculating Energy Requirements of Compressor-Outdoor CoQ Combination for Commercial Installation Heating--Month of January Slip DetaipHon 1. Net Total Calculated Heat Losb at Design Temp, Fig. 12 IMtt Dor Wnhi Btuh 1,610,000 2,130,000 2. Changeover Temperature, Fig. 12 F 41 65 3. Balance Point, fig. 12- F 12 21 4. Below Changeover Temp (given in Line 2) o. Avenge Outdoor Temp, Table 1 6. Hours, Table 1 F 33 Hr 196 37 371 c. Structure Heat Loss, Fig. 12 Btuh 400,000 1,080,000 d. Heat Pump Capacity, Fig. 12 Btuh 2,060,000 1,275,000 e. Kw-Compressor and Fan (from manufacturer's data) Kw /, Kwh-Compressor and Fan: 235 240 4cX46 lines--------- X4e 4d Kwh 8950 44,300 5. Below Balance Point (given in line 3) o. Average Outdoor Temp, Table 1 b. Hours, Table 1 c. Structure Heat Loss, Fig. F Hr 12 17 20 12 Btuh 1,425,000 1.850.000 d. Heat Pump Capacity, Fig. 12 e. Booster Heat: Btuh 1,425,000 1.570.000 (5e-Srf)X56 lines ------------------- Kwh 1640- 3413 6. Total Kwh for Month: Lines 5e+4f Kwh 8950 45,940 7. Grand Total: Day and Night Kwh 54,890 BIBLIOGRAPHY S. M. Minor, Cal Kleinschmidt, and Richard Borcherding: Air-eource heat pump finds its place in northern climates (Actual Specifying Engineer, January 1959 and February 1959). Neil Hill: Heat pump reclaim system proves new Hekgn ap proach (Heating, Piping and Air Conditioning, September 1960). Gershon Meckler: Heat pump redistribution systems (Pro gressive Architecture, December 1959). R. C. Burkhardt and R. G. Werden: Water source heat pump (Actual Specifying Engineer, July 1961). Heat Pump Performance (Symposium Bulletin, American Society or Heating, Rexbiqeratino and Aib-Condittoning Engineeks, 1959). Philip Sporn and E. R. Ambrose: Design and application for electric heat (Air Conditioning, Heating and Ventilating, July 1960). J. R. Hamish: Achieving economy in the design and use of heat pumps (Air Conditioning, Heating and Ventilating, August 1959). L. N. Brown: Heat pumps--basis of operation (All Electric Heat Pump Symposium, Houston TJghtmr and Power Co., . Houston, Texas, April 1959). G. L. JBtehn: Multiple heat pump inatAHatlrma (Air Condition ing, Heating and Ventilating, February 1956). CHAPTER 5 WARM AiR HEATING SYSTEMS Forced Warm Air Systems; Air Distribution; Supply Outlets and Return Grilles; Duct Construction; Simplified Methods of Design for Perimeter Systems of loop, Rodiof, end Extended-Plenum Types; Return Duct System for Perimeter Installations Inside Wall Delivery Systems; Design of large Systems; Automatic Controls; Adjustment of System; Worm Air Ceiling Panel Systems? Summer Operation; Gravity Warm Air Systems ARM air beating systems may be conveniently di system are discussed in Chapter 43 of the 1961 Guide and Wvided into two classifications depending upon the Data Book and other publications.1 fpnnner in which the motive power for circulating the warm air is supplied. In gravity systems, the motive head is due to the difference in weight between the heated air leaving AIR DISTRIBUTION the top of the furnace casing and the cooler return air en tering the bottom of the casing. In a forced warm air heating system, all or part of the motive head is supplied by a fan. Although a great many gravity warm air heating systems are in use, only a limited number of new gravity installations are cow being made. Emphasis will therefore be placed upon the design and installation of forced warm air heating sys tems. The conditions of comfort obtained in a room are influ enced greatly by the type of supply outlet used, and the' locations of the supply outlets and return grilles. In general it has been found that changes in the type, air velocity, and location of the supply outlet affect the room conditions much more khan the changes in the location of the return grilles. Although the principles of air distribution which are dis cussed in Chapter 11 of the 1961 Guide And Data Boos FORCED WARM AIR SYSTEMS apply in the design of warm air heating systems, simplified methods of selecting outlet site and location are usually used. In forced warm air heating systems, the air circulation is effected by motor-driven centrifugal fans, commonly referred to as blowers. The advantages of forced air systems are: Three methods of locating outlets and grilles are in common use. One method is to locate all supply outlets in or near the outside wall, usually beneath windows, and to use outlet grilles or diffusers which deliver the air upward in a fan-shapod 1. The furnace may be placed in any part of the structure. 2. Distribution ducts can be made mall enough to be in conspicuous and out of the way, or be completely concealed from view where desired. pattern to blanket the cold area. This arrangement causes miring of the warm supply air with the cool air from the highheat-loss area and with the cold air from infiltration, to pre vent drafts. This method of introducing warm air into a struc 3. Circulation of air is positive, and is a properly designed system, can be controlled in such a way as to give a comfortably uniform temperature distribution. 4. Humidity control, is readily attained. 5. The air may be cleaned by filters or other means. 6. If properly designed or suitably adapted, the same air * distribution system can be used for summer cooling as for winter heating. 7. The use of the fan permits flexibility in the location of supply and return grilles as required to obtain proper distribu tion of air for comfort. 8..Controlled quantities of ventilation air may be drawn into the system and conditioned before it is introduced into occupied portions of the structure. Recirculated air can be treated as necessary to obtain `the desired quality. ture is called perimeter heating. A second method is to locate the supply openings on the inside wall, near the floor or near the ceiling) and locating the return openings near the greatest outside exposure. A third method is to locate the supply outlets in the coiling, and the return openings near the greatest out side exposure. Any of these methods of introducing the supply air can be used for summer air conditioning. In any case, the warm air registers should be so located and so designed that the air stream never discharges directly against people at rest. Tests' in Warm Air Research Resi dences No. 1 and No. 2 at the University of Illinois, have indicated that nearly continuous blower operation gave bet ter results than intermittent.operation. This type of opera tion is more commonly, achieved by suitable adjustments of Warm air heating systems are equally adaptable for use in air quantity and fan switch settings than by continuous residential and non-residential structures. Although most operation of the blower.' commonly found in one and two family residences, recent developments in equipment and system design have con-- Supply Outlets and Return Grilles iributed to the increase! use of warm air heating systems in school buildings, apartment houses, and commercial and The type of supply outlet that should be used'depends industrial structures. Other factors which have contributed upon the type of distribution system to which it is applied. to this trend include the desire to use one distribution system With perimeter duct systems, the supply outlets are usu for both winter and summer air conditioning, and the desire ally located, in the floor, in the baseboard, or low-in the of owners to turn over to the tenant responsibility for ail side-wall and underneath a window. In order to be most ef utilities in apartments and commercial buildings. fective, perimeter diffusers must deliver the air upward and The construction features of forced warm air furnace in a fan-shaped pattern so as to blanket the window or cold units and the function and selection of the various parts of a wall with warm air, thus mixing with and tempering the 61