Document pm6y2LaryzoO3mbVaJepmonX7
>\s~
TOXIC FUItljUTANT EFFLUENT REGS: ALTERNATIVE APPROACH TO PCD LIMITS
The potential environmental hazards of biphenyl with low
levels of chlorination are different than biphenyl with
high levels of chlorination and, therefore, should receive
different effluent limits. t<- < ? popcihio
nr-n,.
for the purpose of setting effluent Hml to---as mono, di,
tri, tetra, penta and hexacnlorobiphenyl, the major isomer
groups of all "PCBs. Cl7--to -Clyg-Bipheny 1 compounds may be
too non-volatile for conventional GC-HS analysis (See
attachment, "Polychlorinated Biphenyl (PCB) Analysis.")
Individual isomers within each group should be treated
alike unless future data regarding environmental hazard
shows specific isomers to be significantly different from
the group.
Table I provides data from which an alternative approach to establishing effluent limits for these PCB groups has been derived according to their bioconcentration factors. Values for partition coefficients in Table I were calculated accord ing to the method of Leo, et al.* The bioconcentration factor for tetrachlorobiphenyl in rainbow trout has been experimentally determined (preprint by Branson, et al. attached). Biocon centration factors for the other chlorinated biphenyls were calculated according to the method of Neely, et al. (Preprint attached.).
The water levels that impact unsafe residues in fish can be estimated from the relative bioconcentration factor at steady state as follows:
CF " Concentration of chemical in fish flesh that is unsafe, e.g. 5 ppm for PCB
BF Bioconcentration Factor
.
Cw " Concentration of chemical in water
The water quality criteria for PCB's shown in Table I were calculated using this approach. Thus, water of acceptable quality for a fish habitat should be realized if the concentration of PBC isomers (C,,^. ..C ) satisfy the equation:
*A. Leo, C. Hansch, and D. Elkins, Chem Rev.,
525 (1971).
HONS 039609
* * >.
2-
590
+ 3.400 Cy,2 + 3400
+. 12,300 Cw< + 19,000
+ 47,000
5 mg/1
After designation of acceptable levels of PCB's in the receiving water, allowable discharges from point sources should be set in individual NPDES permits.
How does this alternative approach differ from that proposed by the EPA, 40 CFR Part 129?
1. The concept of pounds per day in effluents of PCB's like Aroclor 1242 or 1254, etc. would be discontinued.
2. The bioconcentration factors, and, therefore, water quality criteria and effluent limitations, are based on the properties
of individual PCB isomer groups. The bioconcentration factor of 200,000 used to calculate effluent limits in the proposed regulations is not characteristic of all members of this class of compounds.
3. The effluent limits are based on water quality criteria. The allowable discharge from each point source would be aet at the local level and stipulated in the NPDES permit.
Dean R. Branson March 4, 1974
HONS 039610
Chemical
TABLE I. WATER QDM.ITT CRITERIA TOR CHLOROBIPHENYLS
to* . . (a) Partition'3' Coefficient
Bioconcentration Factor Cv/Cw
Concentration (yg/1) of PCB in water leading to 5 ppm in trout flesh
Chlorobiphenyl
4.9
590<b)
8.5
Dichlorobiphenyl Trichlorobiphenyl
5.6 6.3
l,400(b) 3,400lb)
3.6 1.5
Tetrachlorobiphenyl
7.0
12,300 + 2,300 ^
0.40
Fentachlorobiphenyl
7.7 .
19,000(b)
0.26
.
Hexachlorobiphenyl
8.4
46,000(b)
0.11
^Calculated according to the method of Leo, et al. (Chem Rev., 71, 525 (1971)) assuming n = 0.7 for each aromatic chlorine, and confirmed by adding ir values for chlorobenzenes.
^Calculated value from Log BF = 0.56 Log P oct + 0.124 (See attached preprint by Neely, et al.).
^Measured value (See preprint by Branson, et al.).
TT96C0 SNOW