Document pm313wxVXpkm7aNMYp85joRzw

John J, Nesbitt, Inc. Executive Offices and Factory State Road and Rhawn Street, Holmesburg, Philadelphia Branch office. 11 Park Place, New York Sales and Service Through Offices of the American Blower Corp. In all the Principal Cities of the United States PRODUCTS 1: Universal Heating and Ventilating Unit for SCHOOL ROOMS. 2: Universal Unit Heaters for LARGE ROOMS like Banking Rooms Rooms, Stores, Sales Rooms, Offices, Assemblies, Churches, etc. ' Show 3: Nesbitt Concealed and Cabinet Radiators for HOMES, Offices, Etc. .1. Universal Heating and Venti lating Unit for SCHOOL ROOMS "Universal" has always been at the fore front in the use and development of the features that have made the Unit system universally accepted as ideal for school room heating and ventilating. Among many other major improvements, the Uni versal Unit introduced the light weight heater, the present-day form of unit with motor and fan assembly in base of cabinet, alternating current motors with rigid metal to metal mounting and the successful use of the blast system whereby direct radia tion is eliminated from the class room. Three Point Lead Mounting The Motor and Fan assembly of the Universal Unit is mounted in the cabinet on three steel ball points in contact with lead liners, making a very quiet operating unit, with no electrical noises. It has also made practical the use of alternating cur rent motors with a permanent and rigid supporting device. Fans Universal fans are of the Sirocco type, multiblade, low speed, double inlet, designed to operate at 720 r.p.m. plus or minus 5 per cent. No greater efficiency known. The by-pass chamber is parallel to heating chamber and so located as to "Universal" Multifin Copper Tube Radiator Standard Universal Units are supplied with horizontal seamless copper tube radia tors, the ends of the tubes-of which are connected to cast iron headers by means of ground joints, thus being free of soldered, braised, welded or packed joints. Over these tubes are hydraulically pressed thin copper plates or fins, thus insuring real thermal contact between tubes and plates, making a highly efficient heating unit. Tested at 125 pound working pressure, and will stand freezing without breaking. Motor ` The motor of the "Universal" Unit is supplied for quiet operation on any charac ter of current. The use of a motor genera tor set is no longer necessary with this system, but will be furnished upon request. 682 u I. AfaW. Heaters, Unit i(je the column of cool air across the Smarts of warm air when mixing--thus plating an absolutely vertical discharge-- Sd guide the cool air away from room occupants when completely by-passing. The large space between the fan and the radiator results in the uniform distribution and heating of entire air volume. Sizes and Capacities Universal Unit Heating and Ventilating Cabinets for schools are obtainable in six sizes of cabinets, with six different air deliveries. Two different radiator sizes are available for each cabinet size. Thru the operation of the volume regulators, it is possible to obtain any delivery between the minimum of 450 c.f.m. and the maxi Thermostatic Control Optional mum of 1500 c.f.m. Refer to table of Capacities and Dimen o All Universal Units can be equipped .with thermostatic and pneumatic attach ments for pneumatic control of the inlet damper and thermostatic control of the by-pass damper. This equipment is optional. - .2. sions on pages 22 and 23 of the " Universal Heating & Ventilating Unit," publication No. 210--(A. I. A. File No. 30-d-ll) for complete information. Send for this publication--as well as our Catalogue and Engineers Data Book. Larger Heating Capacity in Smaller Space: Universal Unit Heaters with five times the heating capacity require but one- Universal Unit Heaters for fifth the space taken up by direct radiators LARGE ROOMS and beautiful interiors like Banking Rooms, Show Rooms, Stores, Offices, Assemblies, Churches, etc. The Universal Unit Heater maintains a uniform temperature in the room--ceiling and Boor alike--and it does this to the satisfaction of the heating engineer. It is also sufficiently, attractive to meet the exacting requirements of the architect, and ------------ ------------ and can often be entirely concealed. This is especially important in centers of high rent where the best use must be made of all space. Tremendous Saving in Fuel: High velocity heat diffusion from the vertical discharge results in uniform temperature over entire area, with only slight difference between floor and ceiling, effecting a tre mendous saving in fuel by eliminating overheating of upper areas. Quick Heating of Large Areas: in the room. i Rapid circulation of air by low speed motor Universal Unit Heaters are made on the driven fans over a high efficiency copper same principles that have made the Uni tube radiator results in quick heating of versal Heating and Ventilating Unit for Sjchools so popular during the past 16 years. In them you will find the same high velocity vertical discharge, the same highly efficient Universal Multifin Copper Tube Radiator with its ground joint con nections and its extra strength for more than working pressures and ability to stand up under freezing without breaking. You will find the same low speed, long . life, trouble free motor----either alternating or direct current--with the three point suspension of motor and fan on lead liners, making an assembly almost entirely free from operating noises. You will find the same Sirocco type aluminum multiblade low speed double inlet fan. You will find the same volume regulators on the outlet of the fan housing so the air delivery of the Unit can be regulated to the requirements of the room. ADVANTAGES of Universal Unit Heaters Attractive in Appearance: Encased in a beautiful Cabinet of heavy high grade furniture stock steel. Typical installation in a Sola Roam, where can! inch J `7**' is valuable, the Universal Unit Inter less space and is more efficient. 683