Monsanto MONSANTO INDUSTRIAL CHEMICALS CO. Ssuoet. Illinois 62201 Phon: (6161 271-5035 December 31, 1974 Mr. Richard Hauser Electrical Utilities Company, 2427 St. Vincent Avenue LaSalle, Illinois 61301 Inc. Dear Mr. Hauser: Re:"AD HOC PCB Committee" Tabulated below are the PCB analyses of various semples taken on 11/21 and 11/22/74. All PCB Concentrations are expressed in micrograms per liter. Same as parts per billion (ppb). 1. Composite sample taken 11/21 & 11/22/74 PCB1 s 2,077.7 ppb (This is sample from 6" main plant effluent. Flow was intermittent during the 20 hr. sampling period with estimated flow less than 5 gpm) 11. Grab sample taken 11/22/74 (From storm water sewer on opposite side of building which also contains Evaporative Cooling Water) 5 ppb III. Plant water taken 11/22/74 (From faucet at sink in Dr. Moore's laboratory) ^ 0.25 ppb IV. Illinois river at LaSalle 11/21/74 (Grab sample taken along river bank. Upstream of plant discharge via municipal treatment plant). <0.25 ppb V. Illinois river at Peru 11/21/74 (Grab sample taken along river bank. Downstream of plant discharge) < 0.25 ppb VI. Soil sample at Peru 11/21/74 (Sample taken along Illinois river bank. Downstream of plant discharge). 28 ppb Sample size and laboratory background at Sauget do not permit quantification below 0.25 ppb. unit of Monsanto Company MQNS 093561 Page 2 Mr. Richard Hauser The above information plus flow data from your plant, should permit you to complete the EIA questJonaires. David Hillis is familiar with how and w*ere samples were taken. Call me (6l8) 271-5035 If you have any questions. Very truly yours. EES tmd Edward E. Stewart MONS 09356^