Document pe92xEyboME1pXM7Z6XV4V2dX

Copy From JOHNSON A HIGGINS un nooi. ni uoimi and kaih builbixo 707 east main street P. O. BOX 1137. RICHMOND. VIRGINIA 33308 AL. 4/TSB-BtOI December 5, 1980 ND'-: U ci:i v;:p Mr. Lee McManus Account Executive Engineering Division The Travelers Insurance Companies One Tower Square Hartford! CT 06115 Re: Reynolds Metals Company Reynolds Aluminum Building Products Co. (TILO) Stratford, Connecticut Dear Lee: 1 I have discussed the .concerns listed In your November 8, 1980 letter with Mac Cole, Reynolds' Manager of Industrial Hygiene and Larry Tropea, Director of Environmental Control. I will discuss the concerns separately: 1. Fiberglass - One of Reynolds' Industrial Hygienist made a comprehensive survey on March 5*7. 1930 for airborne fiber concentration and total airborne dust concentration at the asphalt roofing line. Personal samples were collected for thirteen employees. Analyses was done gravlmetrlcally at Reynolds Reduction Research Laboratory In Llsterhlll. OSHA has not established a standard for airborne fiberglass, however, NIOSH has recoonendeo that concentration should be below 3 fibers per cubic centimeter of air (3 f/cc), and the concentration of total all boom fiberglass dust should be below 5 ml 111 grams of dust per cubic meter of air (5 mg/m3). All airborne fiber samples showed concentration well below the recommended limit. The sampling results Indicated no health hazard associated with fiberglass. This conclusion Is reinforced by the fact that fibers used are of a large diameter and as such are considered non-resplrable. The Reynolds Industrial Hygienist made several recommendations to minimize the discomfort associated with the handling of fiberglass. Protective measures included proper clothing, showers, changing clothes, appropriate gloves, good housekeeping, etc. These points ware covered with employees at the time of the survey. These controls require on-going training and supervision. R MC0800280000350 Mr. Lee McManus Decenber 5, 1980 Page Two Copy From JOHNSON' A HIGGINS Un nooi. m norm and main toiuixa 707 EAST MAIN STREET P. O. BOX 1137. RICHMOND. TIRGINU 23308 2. HIoh Noise Level - The blower system used for limestone transfer was Installed after the Industrial Hygienist's last visit. Mac Cole will follow up on this. He doubt sound levels of 140 dBA (104 is more likely). 3. Asphalt - A comprehensive asphalt fume survey was made during three days In September 1978. All personal sample results were concentrations well below the NIGSH recommended celling value for asphalt fumes of 5 mg/m3. Benzo(a) pyrene was not detected. .4 Asbestos - The last survey for airborne asbestos was In 1976. As you know, the use of asbestos was discontinued several years ago. Mac will follow up to see If there Is a potential exposure from fibers remaining on overhead beams In the warehouse. At the time of the last survey a recommendation was made to clean overhead areas. Surveys for silica and other airborne dust since 1976 did not reveal any asbestos. 5. Landfill Area - Asbestos and Asphalt Spills - Mac also plans to look Into this. 1 also discussed this concern with Larry Tropea. Presently, Larry's department Is Involved with an extremely high prlorty project. When this Is resolved, his department will check the TILO situation. I reviewed each of the Industrial Hygienist's reports In Mac's office and was Impressed by the detailed attention these potential exposures have received. Should you have additional questions, please let me know. Very truly yours Robert F. Satterfield Senior Loss Control Consultant nr* n n wuiff ^ Mr. U. H. Murphy i* RMC0800280000351