Document pe8Ya7Q9XVkKKLV0EqQNGLKrB

Inspection Date(s): Time: Program: Regulatory Program(s): If Access is Denied: REGION 10 Enforcement Division INSPECTION REPORT 09/13/2021 - 09/15/2021 Announced: No Entry: 09:41 AM (AKT) Exit: 12:05 PM (AKT) RCRA Title 40 - ENVIRONMENTAL PROTECTION AGENCY Company Name: Facility or Site Name: Facility/Site Physical Address: (City, state, zip code) Type of Operation: Size of Facility: Length of Facility at Location: Geographic Coordinates: Mailing address: (Secondary Address) University of Alaska University of Alaska Fairbanks Tanana Loop Fairbanks, AK 99775-8145 University 2,250 acres Since 1922 64.8541, -147.8221 Ms. Tracey Martinson, Director EHSRM tamartinson@alaska.edu P.O. Box 758145 Fairbanks, AK 99775-8145 CC: Richard Deck, Hazardous Materials Supervisor redeck@alaska.edu (City, state, zip code) County: Kris Riley, Hazardous Materials Coordinator kcriley@alaska.edu Fairbanks, AK 99775-8145 Facility/Site Identifier: Media Number: NAICS: AKD048679567 N/A 611310 - Colleges, Universities, and Professional Schools Lead Inspector: Jon Jones Jones, Jon REGION 10 Digitally signed by Jones, Jon Date: 2021.12.06 11:08:23 -09'00' Jones.Jon@epa.gov (907) 271-6329 Additional Persons Participating in Inspection: Supervisor Review: Jen Sullivan Jennifer A Sullivan REGION 10 1 of 85 Digitally signed by Jennifer A Sullivan Date: 2021.12.06 12:30:20 -08'00' Sullivan.Jennifer.A@epa.gov (206) 553-6978 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 SECTION I - INTRODUCTION Purpose of the Inspection/Objective Type of inspection: CEI - Compliance Evaluation Inspection This was a Resource Conservation and Recovery Act (RCRA) inspection. The facility was inspected to ensure compliance with standards for hazardous waste generators and universal waste management (40 C.F.R. Part 262 through 273) and used oil management (40 C.F.R. Part 279). The inspection was conducted as part of a Core Program requirement for FY 2021. Attendees Title Name Lead Inspector Jon Jones Hazardous Materials Supervisor Richard Deck Hazardous Materials Coordinator Kris Riley Director EHSRM Tracey Martinson Director of Utilities Kurt Knitter Phone Email 9072716329 Jones.Jon@epa.gov (907) 474-5617 redeck@alaska.edu Present in Opening Conf. Yes Yes Present in Closing Conf. Yes Yes (907) 474-7889 kcriley@alaska.edu Yes Yes (907) 474-6603 tamartinson@alaska.edu No Yes (907) 474-7091 kknitter@alaska.edu No Yes Opening Conference EPA Lead Inspector Jon Jones arrived at the University of Alaska Fairbanks at 09:41 AM (AKT) on 09/13/2021 for an inspection. I presented my credentials to Richard Deck and informed him that this was an EPA RCRA inspection. The table above presents all the opening and closing conference inspection participants. Facility/Site Description University of Alaska Fairbanks (UAF or facility) is located on the west side of Fairbanks, Alaska. Additional information about UAF can be found on their website at www.uaf.edu. Facility Info Number of employees 670 Faculty, 2,912 (full and part-time) staff and 1,061 student employees Operating Hours Monday through Friday from 9:00 a.m. to 5:00 p.m. Safety Training No Provided to Inspector(s)? What type of generator facility verified as? Still operating as a Large Quantity Generator; however, most of the time and since the onset of the COVID-19 pandemic, the facility has been a Small Quantity Generator. 2 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Weather Conditions What type of generator facility notified? Cool and cloudy Large Quantity Generator 09/13/2021 - 09/15/2021 Process Description Changes since the last inspection: Facility now manages waste aerosol cans as universal waste. New Power Plant has gone online - generating coal ash, waste lamps managed as universal waste, and used turbine oil. Atkinson Central Power Plant has been decommissioned. Notified under Subpart P for waste pharms - Student Health Counseling Center, Veterinary clinic. Facility opted into Subpart P; however, they do not generate any waste pharmaceuticals, either hazardous waste or non-hazardous waste, that would go back to a reverse distributor for credit. Mr. Riley joined the opening conference at 10:18 a.m. I asked for a list of all the hazardous waste and universal waste accumulation areas and was provided with this information during the inspection which is also included as attachments to this report. During the inspection I was accompanied by Messer's. Deck and Riley. During the inspection I looked at the facility's processes, in addition to hazardous waste management practices, generation points, and accumulation areas. I looked for wastes that facility representatives had not yet identified or designated as hazardous. I also observed the facility's universal waste and used oil management. Specifically, I inspected the following areas of the facility listed below. Building(s) Building/Area/Sub-area AFES Experimental Farm AFES Maintenance Garage Used oil accumulation area Waste aerosol SAA Atkinson Power Plant Maintenance Shop SAA North stairwell leading to the old control room Bldg. 799 - Hazardous Materials Handling Facility (HMF) Covered storage area Cell D Process Description Agricultural & Forestry Experimentation Station Universal waste accumulation area Central accumulation area and product storage area. Used oil and product storage area Product storage area for Iso-Propyl Alcohol. 3 of 85 Area of Concern Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Cell E Used oil and product storage area. Yes Flammable and Corrosive storage cabinets Used both to store Non and HW as well as surplus No product. North end of the building Yes South end of the building Waste battery and waste aerosol sorting area. Yes Area beside door leading out to the Yes covered storage area (outside) Top of flammable storage cabinets Yes Bldg. FS306 - Duckering Building Engineering classes and labs Yes Room 442 - ASIF Lab Yes Fume hood SAA Yes Room 444 - ASIF Lab Yes Fume hoods SAA containers Yes Room 448 - Alaska Stable Isotope Lab area divided into Lab A and Lab B Yes Facility Lab B SAA Yes ELIF Bldg. 304 Engineering, learning and innovation facility. Yes Room 211 Lab Yes East end of lab Yes Fume hood SAA Yes Yellow flammable storage cabinet SAA Yes Facility Services Yes Customer Service UW accumulation area Yes Paint Shop Yes Paint booth Yes Step-can outside Rm 152B - Paint Yes Shop Tool & Paint Storage Trash can next to deep sink Yes Room 140 - Transportation / Vehicle Yes services Waste Aerosol SAA Yes Room 141 - Alarm/Electrical/HVAK Accumulation area for used oil and waste aerosol Yes SHOP cans. Room 142 - Plumbing Shop Aerosol accumulation Yes Fine Arts Complex - Bldg. 313 various classrooms with SAA's generating paint No solvent and rags. Irving I Bldg. Institute of Arctic Biology Yes Rm 207 Lab Yes Area just in front of the vent hood Yes Rm 409 Lab Yes 4 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Fume hood Murie Bldg. - Biology (arctic) Rm 209 Prep Lab Fume hood Rm 318 Lab table Fume hood Room 318B Fume hood Reichardt Bldg. (Chemistry Labs) Chemical Storage rooms Lab 241 Fume hood Lab 242 Fume hood Lab 246 Fume hood rm 132 Chem Lecture prep Fume hood Rm 143 Chem Research Lab Cabinet beneath Fume hood Room 191 Chem Research Lab Table on right as you enter the lab Room 193 (Lab) Fume hood Room 244 Fume hood William A. O'Neill Bldg Rm 143 Area adjacent to the Fume hood Rm 145 Fume hood SAA for waste HCL acid Fisheries and Ocean Science Labs Zooplankton & Benthic Ecology Lab SAA SAA for waste formalin SECTION II - OBSERVATIONS AND RECORDS REVIEW Observations Building: AFES Experimental Farm/AFES Maintenance Garage/Used oil accumulation area Observation #: JJ1-OB-045 Contains CBI: No Date: 09/15/2021 09/13/2021 - 09/15/2021 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 5 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 At the time of the inspection, there was a 5-gallon container beneath the oil filter crusher that contained used oil. At the time of the inspection the container was not labeled with the words "Used Oil." Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both verbal and photo documentation that the 5-gallon container beneath the oil filter crusher had been labeled with the words "Used Oil." Photo(s) 1. Observation_Image-20210915110050050204900.jpg 2. Observation_Image-2021091511010010193314.jpg 3. Observation_Image-2021091511010818211622.jpg Building: AFES Experimental Farm/AFES Maintenance Garage/Waste aerosol SAA Observation #: JJ1-OB-044 Contains CBI: No Date: 09/15/2021 While at the AFES Maintenance Garage, I saw a clear plastic tote labeled with the words, "hazardous Waste" and "Waste Aerosol Cans" that contained waste aerosols. At the time of the inspection, the tote was not marked with a hazard indicator. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the clear plastic tote that contained waste aerosols had been re-labeled with the words "Universal Waste-Aerosol Cans." Photo(s) 1. Observation_Image-20210915105208528172528.jpg 2. Observation_Image-202109151052235223346221.jpg Building: Atkinson Power Plant/ Maintenance Shop Contains CBI: No SAA Observation #: JJ1-OB-018 Date: 09/14/2021 While inspecting the satellite accumulation area (SAA) near the maintenance shop, I saw a 55-gallon container with an attached aerosol can popper and filter. I asked the operator, Mr. Dean Ojala, Jr., CT3 Maintenance Mechanic Lead, about the container and he said they puncture aerosols into the container. At the time of the inspection, the container was approximately 1/6 full. The container was not labeled with the words "Hazardous Waste" and had no hazard indicator. UAF recycles the punctured aerosol cans as scrap metal. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the 55-gallon container had been labeled with the words labeled with the words "Hazardous Waste" and a hazard indicator. Photo(s) 1. Observation_Image-202109141014131413241071.jpg 2. Observation_Image-202109141014251425205672.jpg 3. Observation_Image-202109141014431443230892.jpg 6 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Building: Atkinson Power Plant/ Maintenance Shop Contains CBI: No SAA Observation #: JJ1-OB-019 Date: 09/14/2021 While at the SAA, I saw two 55-gallon containers that Mr. Ojala, Jr. said were being used to store used turbine oil. Neither container was labeled with the words "Used Oil." Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the two 55-gallon containers had been labeled with the words "Used Oil." Photo(s) 1. Observation_Image-202109141021212121252710.jpg 2. Observation_Image-202109141021302130254863.jpg Building: Atkinson Power Plant/North stairwell leading to the old control room Observation #: JJ1-OB-017 Contains CBI: No Date: 09/14/2021 While inspecting the old Atkinson Power Plant, I saw two, four-foot cardboard boxes that Mr. Deck confirmed contained waste fluorescent lamps. One box was closed and had no labeling and the other box was labeled as universal waste lamps but not closed. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the two cardboard boxes that contained waste fluorescent lamps were taken back to the Bldg. 799 - Hazardous Materials Handling Facility (HMF), where they were repackaged and labeled with the words "Universal Waste-Lamps." Photo(s) 1. Observation_Image-202109140958245824330242.jpg 2. Observation_Image-202109140958405840158073.jpg 3. Observation_Image-20210914095903593165539.jpg Building: Bldg. 799 - Hazardous Materials Handling Facility (HMF)/Covered storage area/Cell D Observation #: JJ1-OB-002 Contains CBI: No Date: 09/13/2021 While at the HMF, I saw seven, 55-gallon containers in Cell D. I looked at the labeling on one of the containers and saw that it was labeled as containing Iso-Propyl Alcohol. The containers were in a bermed concrete containment area that held an accumulation of liquid (potentially rainwater). I could see rust around the bottoms of the containers. According to Mr. Deck, five of the containers held Isopropanol, one held Methanol, and one held Ethanol. Mr. Deck told me that the containers held product that was used in various labs across campus. Photo(s) 1. Observation_Image-2021091311132513251898201.jpg 2. Observation_Image-2021091311135613561859018.jpg 7 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 3. Observation_Image-2021091311141314131624579.jpg 09/13/2021 - 09/15/2021 Building: Bldg. 799 - Hazardous Materials Handling Facility (HMF)/Covered storage area/Cell E Observation #: JJ1-OB-001 Contains CBI: No Date: 09/13/2021 While at the covered storage area, at Bldg. 799, in Cell E, I saw several 55-gallon containers that were rusted at the bottom. According to Mr. Deck, the containers held product. According to the labels on the containers, they held North Slope Crude Oil and were marked with DOT Class 3 hazard indicators. There were three containers and two of the three were also bulging at the top and bottom of the container. Photo(s) 1. Observation_Image-202109131103443441502549.jpg 2. Observation_Image-202109131104154151421441.jpg 3. Observation_Image-202109131104354351602830.jpg Building: Bldg. 799 - Hazardous Materials Handling Facility (HMF)/Flammable and Corrosive storage cabinets Observation #: JJ1-OB-009 Contains CBI: No Date: 09/13/2021 At the time of the inspection, I observed several flammable, toxic, oxidizer, and corrosive storage cabinets in Bldg. 799 HMF. The exterior of each cabinet was marked with a hazard indicator. Mr. Deck confirmed the contents in the cabinets consisted of both product and hazardous waste. The products and wastes were separated in each cabinet by either being placed on separate shelves or on opposite ends of the same shelf. I looked at the wastes inside the cabinets and saw that all the hazardous wastes were labeled with the words "Hazardous Waste", but not a hazard indicator. Photo(s) 1. Observation_Image-202109131247474747150556.jpg 2. Observation_Image-202109131248094891735814.jpg 3. Observation_Image-2021091312533453341070489.jpg Building: Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building Observation #: JJ1-OB-003 Contains CBI: No Date: 09/13/2021 While in the HMF, I saw a pallet that contained boxes of four-foot fluorescent lamps that were labeled as universal waste. There were eight lamp boxes on the pallet and three of those lamp boxes were not closed. Two of the lamp boxes were not structurally sound. I saw one box at the bottom of the pile of boxes on the pallet, that was crushed from the boxes that were on it. It appeared to me to the weight of the other boxes caused the box on the bottom of the pile to be open. The other open box was broken (and therefore open) on the side. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the cardboard boxes that contained waste fluorescent lamps had been repaired. Photo(s) 8 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 1. Observation_Image-2021091311294929491559795.jpg 2. Observation_Image-202109131130013011509344.jpg 3. Observation_Image-2021091311301930191336300.jpg 09/13/2021 - 09/15/2021 Building: Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building Observation #: JJ1-OB-004 Contains CBI: No Date: 09/13/2021 While in the HMF, I saw 14 small cardboard box containers. I asked Mr. Riley what the boxes held, and he said they held waste light ballasts and that each one contained a Ni-Cad battery. At the time of the inspection these ballasts were not labeled as a universal waste battery. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the battery containers had been labeled. Although labeled, the photo documentation did not show that the containers were labeled with the words "Universal Waste." The photo showed them labeled as Non-RCRA waste. I contacted Mr. Deck by telephone on 11/22/21 to inquire about the labeling and he followed up with an email letting me know that the battery containers were in fact labeled with the words "Universal Waste." Photo(s) 1. Observation_Image-2021091311383238321576453.jpg 2. Observation_Image-202109131138533853122851.jpg 3. Observation_Image-20210913113905395146294.jpg Building: Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building Observation #: JJ1-OB-005 Contains CBI: No Date: 09/13/2021 While in the HMF, I saw a cart that held some boxes and a plastic container. The plastic container held various types of waste batteries including lithium and NiCad. According to Mr. Riley, the batteries were picked up from other locations on campus last Friday (9/10/21) and brought to the HMF. According to Mr. Deck, the waste lithium and NiCad batteries are managed as universal waste. There were at least 13 lithium/Ni-Cad batteries in the plastic container. Neither the plastic container nor any of the batteries were labeled as universal waste. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the battery containers had been labeled. Although labeled, the photo documentation did not show that the containers were labeled with the words, "Universal Waste." The photo showed them labeled as Non-RCRA waste. I contacted Mr. Deck by telephone on 11/22/21 to inquire about the labeling and he followed up with an email letting me know that the battery containers were in fact labeled with the words "Universal Waste." Photo(s) 1. Observation_Image-2021091311534453441562417.jpg 2. Observation_Image-202109131154035431710847.jpg 3. Observation_Image-202109131156095691475895.jpg Building: Bldg. 799 - Hazardous Materials Handling Contains CBI: No Facility (HMF)/South end of the building 9 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Observation #: JJ1-OB-006 Date: 09/13/2021 At the time of the inspection, I saw a covered metal tray. The label on the tray indicated that it held an ultraviolet (UV) light bulb/lamp that contained mercury. According to Mr. Deck it had been in storage for approximately six months and would be managed as a universal waste lamp. The UV bulb/lamp was not labeled as universal waste. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, in which he stated that the UV bulb/lamp had been shipped to Total Reclaim, along with other universal waste lamps for recycling on September 14, 2021 and September 16, 2021. Mr. Deck also provided a copy of the bills of lading for the lamp shipments. Photo(s) 1. Observation_Image-2021091312232023201690922.jpg 2. Observation_Image-2021091312233823381658533.jpg Building: Bldg. 799 - Hazardous Materials Handling Contains CBI: No Facility (HMF)/South end of the building/Area beside door leading out to the covered storage area (outside) Observation #: JJ1-OB-007 Date: 09/13/2021 While still inspecting the HMF, I saw a box that was labeled "Universal Waste -Lamps." The container held fourfoot waste fluorescent lamps and was dated 7/20/20. At the time of the inspection, the container of universal waste-Lamps had been in storage for greater than one year. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, in which he stated that the universal waste-lamps had been shipped to Total Reclaim, along with other universal waste lamps for recycling on September 14, 2021 and September 16, 2021. Mr. Deck also provided a copy of the bills of lading for the lamp shipments. Photo(s) 1. Observation_Image-202109131231323132181086.jpg 2. Observation_Image-202109131231513151123982.jpg 3. Observation_Image-20210913123158315899644.jpg Building: Bldg. 799 - Hazardous Materials Handling Facility (HMF)/South end of the building/Top of flammable storage cabinets Observation #: JJ1-OB-008 Contains CBI: No Date: 09/13/2021 While still inspecting the HMF, I saw a box on top of some flammable storage cabinets that was being used to accumulate eight-foot waste fluorescent lamps. At the time of the inspection, the container was labeled as "Universal Waste -Lamps" and was dated 7/7/20. 10 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 At the time of the inspection, the container of universal waste-Lamps had been in storage for greater than one year. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, in which he stated that the universal waste-lamps had been shipped to Total Reclaim, along with other universal waste lamps for recycling on September 14, 2021 and September 16, 2021. Mr. Deck also provided a copy of the bills of lading for the lamp shipments. Photo(s) 1. Observation_Image-20210913123808388193531.jpg 2. Observation_Image-202109131238233823178086.jpg 3. Observation_Image-202109131238313831145309.jpg Building: Bldg. FS306 - Duckering Building/Room 442 - ASIF/Fume hood Contains CBI: No Observation #: JJ1-OB-012 Date: 09/13/2021 While inspecting the fume hoods in room 442, that were used as a SAA, I saw two containers. One was labeled "Ethyl acetate waste" and one was labeled as "DCM & Chloroform waste" At the time of the inspection, neither container was labeled with the words "Hazardous Waste" or the hazard indicators. The other fume hood had a small open container that was labeled "Methanol waste." The container was not closed, and the fume hood was actively running. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of hazardous waste observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. In the email, Mr. Deck stated that the open container marked Methanol waste, in the Room 442 fume hood is an immediate use container used only while the apparatus (Vent hood) is running. Any waste collected is consolidated into the Room 448 Methanol waste container. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109131520542054219516.jpg 2. Observation_Image-20210913152406246378035.jpg Building: Bldg. FS306 - Duckering Building/Room 444 - ASIF/Fume hoods Observation #: JJ1-OB-011 Contains CBI: No Date: 09/13/2021 While in Room 444, I saw some containers in the fume hoods and in the cabinets below the fume hoods such as: Hexane/MeOH/HCL & CHCl3 waste (in fume hood) HCL waste (in fume hood) H2SO4 waste (in cabinet below fume hood) Each of the containers were labeled with the words, "Waste." The containers of waste in the fume hoods and in the cabinet beneath the fume hood held hazardous waste. The containers were not labeled with the words, "Hazardous Waste" or marked with hazard indicators. 11 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of hazardous waste observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109131510591059185091.jpg 2. Observation_Image-202109131511171117177003.jpg 3. Observation_Image-202109131511321132164247.jpg Building: Bldg. FS306 - Duckering Building/Room 448 - Alaska Stable Isotope Facility/Lab B Observation #: JJ1-OB-010 Contains CBI: No Date: 09/13/2021 While inspecting the Lab B room, I looked inside of a flammable storage cabinet which I was told by Mr. Deck was being used as an SAA. While inspecting the contents of the cabinet, I saw various sized containers that held (according to the container labels) wastes such as: Alcohol waste Ethyl acetate waste Acetic acid waste Acetone waste Chloroform waste Benzene, ethanol waste Toluene and ethanol waste Chlorinated waste Hexane waste Waste acidified - isopropyl alcohol KO4 waste Chloroform methanol waste HNO3 waste and Oxalic acid waste At the time of the inspection, none of the waste containers in the flammable storage cabinet, in Lab B, were labeled with the words "Hazardous Waste" or hazard indicators. Neither was the flammable storage cabinet, in Lab B labeled with the words "Hazardous Waste". The storage cabinet was labeled with the word, "Flammable." Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of hazardous waste observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109131449324932875554.jpg 2. Observation_Image-202109131450205020927558.jpg 3. Observation_Image-202109131451105110179778.jpg 12 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Building: ELIF Bldg. 304/Room 211/East end of lab Observation #: JJ1-OB-016 Contains CBI: No Date: 09/13/2021 While in the ELIF Bldg. I saw a plastic container on a table in the lab on the south side of the building that was labeled as waste for pick-up. During the inspection, I requested an inventory of the plastic container. I asked that the inventory include waste type, container size and method of management. None of the wastes in the plastic container were labeled with the words "Hazardous Waste" or hazard indicators. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both verbal and photo documentation that the containers of hazardous waste observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109131628342834180200.jpg Building: ELIF Bldg. 304/Room 211/Fume hood SAA Contains CBI: No Observation #: JJ1-OB-013 Date: 09/13/2021 While in Bldg. 304, Rm 211 I was inspecting the contents of a fume hood that was used as a SSA and saw a container with a funnel. At the time of the inspection the fume hood was operating. According to the label on the container, the container held Dichloromethane. There was a piece of masking tape above the label that contained no writing and is typically used to label containers as waste. There were also three small flasks that were empty and labeled with the words, "Waste." According to Ibnul (student), and Shane Billings, Lab Manager the container with the funnel held a mixture of waste Alaska crude oil, water, and Dichloromethane. At the time of the inspection the container was not closed, and no waste was being added or removed. The container was not labeled with the words hazardous waste or the hazard indicators. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of hazardous waste observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-2021091316094094081809.jpg 2. Observation_Image-20210913160954954117497.jpg 3. Observation_Image-20210913161110111095185.jpg Building: ELIF Bldg. 304/Room 211/Fume hood SAA Contains CBI: No Observation #: JJ1-OB-015 Date: 09/13/2021 While in Bldg. 304, I saw various waste containers beneath fume hood in Rm 211 that were not labeled with the words "Hazardous Waste" or the hazard indicators. 13 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of hazardous waste observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-20210913162340234079439.jpg 2. Observation_Image-20210913162355235590848.jpg Building: ELIF Bldg. 304/Room 211/Yellow flammable storage cabinet Observation #: JJ1-OB-014 Contains CBI: No Date: 09/13/2021 While in Bldg. 304, I saw waste containers inside of a flammable storage cabinet, being used as an SAA, that were not labeled with the words "Hazardous Waste" or hazard indicators. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of hazardous waste observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109131617221722172144.jpg 2. Observation_Image-202109131617461746190186.jpg Building: Facility Services/Customer Service Observation #: JJ1-OB-020 Contains CBI: No Date: 09/14/2021 While inspecting the customer service area, I saw a five-gallon container that, according to the label, was being used to accumulate waste batteries. I opened the container and saw that it also contained two compact fluorescent (CFL) bulbs. The container also held a mix of different batteries including Ni-Cad, lithium and alkaline. The container was dated 3/16/20 and had been in accumulation for greater than a year. At the time this inspection report was written, there had been no response from the facility concerning the areas of concern identified in the observations made while inspecting the customer service area. Photo(s) 1. Observation_Image-20210914110810810122884.jpg 2. Observation_Image-20210914110818818169663.jpg 3. Observation_Image-2021091411083283297909.jpg Building: Facility Services/Paint Shop/Paint booth Observation #: JJ1-OB-026 Contains CBI: No Date: 09/14/2021 14 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 While at the Paint Shop, I saw a step can in the paint booth that contained three waste aerosol cans and was not labeled as "Universal Waste - Aerosols", even though I had been told by Mr. Deck that the University now manages aerosol cans as universal waste. At the time of the inspection, the waste aerosol cans were removed from the paint booth and taken to the HMF, by Mr. Riley, where they were placed into an existing universal waste container for aerosol cans. Photo(s) 1. Observation_Image-20210914120759759184539.jpg 2. Observation_Image-2021091412080888205442.jpg 3. Observation_Image-20210914120821821213790.jpg Building: Facility Services/Paint Shop/Step-can outside Rm 152B - Paint Shop Tool & Paint Storage Observation #: JJ1-OB-025 Contains CBI: No Date: 09/14/2021 While in the Paint Shop, I saw a step-can outside Room 152B that was labeled "Flammables and Spent Aerosol Cans Only." When I opened the step-can, I saw that it contained waste rags, absorbents, and two small, quart sized, open cans that held waste paint and thinner. At the time of the inspection, the step-can was not labeled with the words "Hazardous Waste" or a hazard indicator. I overheard Mr. Deck call Mr. Riley to have him bring a container for the waste paint. Photo(s) 1. Observation_Image-202109141159105910204634.jpg 2. Observation_Image-202109141159185918211624.jpg 3. Observation_Image-202109141159365936182170.jpg Building: Facility Services/Paint Shop/Trash can next to deep sink Observation #: JJ1-OB-024 Contains CBI: No Date: 09/14/2021 While in the Paint Shop, I inspected the contents of a trash can that was next to a deep sink. I saw a waste aerosol can in the trash. At the time of the inspection, the waste aerosol can was not packaged or labeled to indicate that it was being managed as a universal waste even though Mr. Deck told me that all aerosol cans were managed a universal waste. At the time of the inspection, the waste aerosol can was removed from the trash can and taken to the HMF, by Mr. Riley, where it was placed into an existing universal waste container for aerosol cans. Photo(s) 1. Observation_Image-202109141152525252170290.jpg 2. Observation_Image-20210914115300530174973.jpg 3. Observation_Image-20210914115307537175611.jpg Building: Facility Services/Room 140 Transportation / Vehicle services/Waste Aerosol SAA Contains CBI: No 15 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Observation #: JJ1-OB-021 Date: 09/14/2021 At the time of the inspection, the facility was using a small flammable storage cabinet as a container for waste aerosols. The cabinet was not labeled to indicate that it was being managed as a universal waste. The cabinet was labeled with the word "Flammable" along with another label that contained the words "Waste Aerosols Cans Only." Photo(s) 1. Observation_Image-202109141117571757163500.jpg 2. Observation_Image-20210914111807187244898.jpg 3. Observation_Image-202109141118131813126734.jpg Building: Facility Services/Room 141 Alarm/Electrical/HVAC SHOP Observation #: JJ1-OB-023 Contains CBI: No Date: 09/14/2021 While in the SAA, I saw nine loose aerosol cans on the floor of the shop. At the time of the inspection, Messrs. Deck and Riley confirmed the aerosols were waste. The waste aerosol cans were not packaged or labeled to indicate they were being managed as a universal waste even though Mr. Deck had told me that waste aerosol cans were management as universal waste. At the time of the inspection, the waste aerosol cans were removed from the shop and taken to the HMF, by Mr. Riley, where they were placed into an existing universal waste container for aerosol cans. Photo(s) 1. Observation_Image-202109141144274427176096.jpg 2. Observation_Image-202109141144354435183028.jpg 3. Observation_Image-202109141144394439129943.jpg Building: Facility Services/Room 142 - Plumbing Shop Observation #: JJ1-OB-022 Contains CBI: No Date: 09/14/2021 While inspecting the plumbing shop I saw a red step-can that was labeled, "Flammables and Spent Aerosol Cans Only." I opened the step-can and saw one aerosol can, one lithium battery and two small packages each containing a piece of Nicorette (Nicotine) chewing gum. At the time of the inspection, the step-can was not labeled to indicate that it was being managed as a universal waste. At the time of the inspection, the waste aerosol can, and waste battery were removed from the step-can and taken to the HMF, by Mr. Riley, where they were placed into existing universal waste containers. Photo(s) 1. Observation_Image-202109141131433143126603.jpg 2. Observation_Image-202109141131523152206017.jpg 3. Observation_Image-202109141132443244881674.jpg 16 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Building: Irving I Bldg./Rm 207 Lab/Area just in front of the fume hood Observation #: JJ1-OB-043 Contains CBI: No Date: 09/15/2021 While inspecting the fume hood SAA in the Room 207 Lab, I saw a small plastic tray that contained seven small plastic bottles of unknown wastes. There was a handwritten note in the bottom of the tray that read, "These samples are of unknown origin or owner B. M. 8/25/19." Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, in which he stated that the unknowns are truly unknown. In the email he says that once EHSRM Hazmat receives a waste pick up request for the items, they will be tested using the Haztech HazCat system to make the waste determination. Photo(s) 1. Observation_Image-202109151031293129134715.jpg 2. Observation_Image-202109151031473147400253.jpg Building: Irving I Bldg./Rm 409 Lab/Fume hood Observation #: JJ1-OB-042 Contains CBI: No Date: 09/15/2021 While in the Room 409 lab, I saw a container under the fume hood SAA with a faded label. The label read, "Conc HCL waste." There were also two smaller unmarked containers that held unknown liquids and, according to Mr. Deck, would require a waste determination. At the time of the inspection, the container of concentrated HCL waste was not labeled with the words "Hazardous Waste" or a hazard indicator. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, in which he stated that the unknowns are truly unknown. In the email he says that once EHSRM Hazmat receives a waste pick up request for the items, they will be tested using the Haztech HazCat system to make the waste determination. The email also included both written and photo documentation that the container of concentrated HCL waste observed during the inspection was labeled with the words "Hazardous Waste" and a hazard indicator. Mr. Deck also provided a copy of an inventory of the containers identified in the Murie and Irving I buildings. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109151013481348192813.jpg 2. Observation_Image-20210915101401141390885.jpg 3. Observation_Image-202109151014271427351004.jpg 4. Observation_Image-20210915101509159161688.jpg 5. Observation_Image-202109151015251525229796.jpg Building: Murie Bldg. - Biology (Arctic)/Rm 209 Prep Contains CBI: No Lab/Fume hood Observation #: JJ1-OB-039 Date: 09/14/2021 I saw a plastic tray under a fume hood that, according to Mr. Deck, contained vials of waste ethanol. The vials were not labeled with the words "Hazardous Waste" or a hazard indicator. 17 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of hazardous waste observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109141550265026110001.jpg 2. Observation_Image-202109141550365036396655.jpg 3. Observation_Image-202109141550525052376606.jpg Building: Murie Bldg. - Biology (arctic)/Rm 318/Lab table Observation #: JJ1-OB-037 Contains CBI: No Date: 09/14/2021 I saw a plastic container that was labeled "Waste for pickup - Williams lab." Items in the container included batteries. At least one battery was a lithium battery. Neither the container nor the battery was labeled as universal waste. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included a copy of an inventory of the waste batteries I saw in Room 318 of the Murie Building. The inventory contained language that indicated the waste batteries were managed as universal waste. Photo(s) 1. Observation_Image-202109141526422642157943.jpg 2. Observation_Image-202109141526492649132209.jpg 3. Observation_Image-20210914152701271114171.jpg Building: Murie Bldg. - Biology (arctic)/Rm 318/Fume hood Observation #: JJ1-OB-038 Contains CBI: No Date: 09/14/2021 I saw another plastic container inside of a fume hood SAA. The container held six smaller containers all labeled "Unknown" waste. Mr. Deck told me that there had not yet been waste determinations made on the contents of the six containers. There was also a box, under the fume hood that contained a small bottle that had a label on it that said pH 1.68 buffer solution. The bottle was in a beaker that was labeled with a red piece of tape and included the words "Acetone Waste." The bottle of pH 1.68 buffer solution was not labeled with the words "Hazardous Waste" or a hazard indicator. I also saw an unidentified waste that had crystalized. The container it was in was not closed or labeled. It was just sitting out on a table with other items and, according to Mr. Deck, required a waste determination. I saw another container across from the previous table that was labeled with a yellow piece of tape and included the words "Assay Waste." The container was not labeled with the words "Hazardous Waste" or a hazard indicator. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, in which he stated that the unknowns are truly unknown. In the email he says that once EHSRM Hazmat receives a waste pick up request for the items, they will be tested using the Haztech HazCat system to make the waste determination. The email also included both written and photo documentation that the containers of waste observed during the 18 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 inspection were labeled with the words "Hazardous Waste" and a hazard indicator. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109141534143414361930.jpg 2. Observation_Image-202109141534353435311596.jpg 3. Observation_Image-20210914153806386218688.jpg 4. Observation_Image-2021091415382438242645295.jpg 5. Observation_Image-2021091415384738472327055.jpg 6. Observation_Image-202109141541504150167757.jpg 7. Observation_Image-202109141542104210574413.jpg Building: Murie Bldg. - Biology (arctic)/Room 318B/Fume hood Observation #: JJ1-OB-036 Contains CBI: No Date: 09/14/2021 I saw a glass bottle that was labeled as "Extraction Waste" under a fume hood SAA that was inside a larger, open plastic container. The plastic container was labeled, "Hazardous Waste Containment." At the time of the inspection, the glass bottle of waste was not labeled with the words "Hazardous Waste" or a hazard indicator. A second fume hood in the same room (318B) also had containers that were labeled as waste. The containers were not labeled with the words "Hazardous Waste" or a hazard indicator. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers I observed during the inspection under the two fume hoods in this room were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109141516161616469495.jpg 2. Observation_Image-202109141516371637518156.jpg 3. Observation_Image-202109141519261926135089.jpg 4. Observation_Image-202109141519381938540844.jpg 5. Observation_Image-202109141519581958505990.jpg Building: Reichardt Bldg. (Chemistry Labs)/Lab 241/Fume hood Observation #: JJ1-OB-030 Contains CBI: No Date: 09/14/2021 While inspecting Lab 241, I saw containers labeled as waste in a fume hood SAA. At the time of the inspection, the containers of waste were not labeled with the words "Hazardous Waste" or hazard indicators. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. 19 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Photo(s) 1. Observation_Image-202109141410241024189214.jpg 2. Observation_Image-202109141410391039433284.jpg Building: Reichardt Bldg. (Chemistry Labs)/Lab 242/Fume hood Observation #: JJ1-OB-029 Contains CBI: No Date: 09/14/2021 While inspecting Lab 242, I saw containers labeled as waste in a fume hood SAA. There were multiple containers in a plastic tray and two, gallon size containers each of which in its own fume hood. At the time of the inspection, the containers of waste were not labeled with the words "Hazardous Waste" or hazard indicators. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-20210914140128128124477.jpg 2. Observation_Image-20210914140134134164458.jpg 3. Observation_Image-20210914140141141115246.jpg Building: Reichardt Bldg. (Chemistry Labs)/Lab 246/Fume hood Observation #: JJ1-OB-028 Contains CBI: No Date: 09/14/2021 While inspecting Lab 246, I saw a container under the fume hood SAA that for which neither the contents nor the process could be identified by either Mr. Deck or campus faculty. The container was dated 9/13/21. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, in which he stated that the unknowns are truly unknown. In the email he says that once EHSRM Hazmat receives a waste pick up request for the items, they will be tested using the Haztech HazCat system to make the waste determination. Photo(s) 1. Observation_Image-20210914135806586145373.jpg 2. Observation_Image-202109141358275827417387.jpg Building: Reichardt Bldg. (Chemistry Labs)/Rm 132 Chem Lecture prep/ Fume hood Observation #: JJ1-OB-033 Contains CBI: No Date: 09/14/2021 I saw three containers under the fume hood SAA in Room 132. According to a sign attached to the cabinet door the containers were originally in a cabinet under fume hood. At the time of the inspection, the three containers were labeled as waste, but were not labeled with the words "Hazardous Waste" or hazard indicators. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers 20 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109141436583658159620.jpg 2. Observation_Image-20210914143808388702898.jpg 3. Observation_Image-202109141438213821718393.jpg Building: Reichardt Bldg. (Chemistry Labs)/Rm 143 Chem Research Lab/Cabinet beneath fume hood Observation #: JJ1-OB-034 Contains CBI: No Date: 09/14/2021 While inspecting Room 143, I saw a container beneath the fume hood SAA that was labeled as waste, but not labeled with the words "Hazardous Waste" or a hazard indicator. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109141448504850173549.jpg 2. Observation_Image-20210914144900490138975.jpg Building: Reichardt Bldg. (Chemistry Labs)/Room Contains CBI: No 191 Chem Research Lab/Table on right as you enter the lab Observation #: JJ1-OB-032 Date: 09/14/2021 While inspecting Room 191, I saw two, four-liter SAA containers on a table . The containers were labeled with red tape that contained the words, "Organic Waste." I did not see any label indicating whether the contents of the containers were a hazardous waste, nor did I see a label that indicated the hazards of the container contents. At the time of the inspection the containers were not labeled with the words "Hazardous Waste" or a hazard indicator. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators as well as a copy of an inventory of the containers I saw on the table. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109141430263026203754.jpg 2. Observation_Image-202109141430383038739497.jpg Building: Reichardt Bldg. (Chemistry Labs)/Room 193 (Lab)/Fume hood Observation #: JJ1-OB-031 Contains CBI: No Date: 09/14/2021 21 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 While inspecting the Room 193 lab, I saw a fume hood that was being used as a SAA in Room 193. The fume hood was operating. Under the hood I saw an open container labeled waste H2S04. The container was not closed when we first entered the room, and I did not observe any waste being added or removed from the container under the hood. Arianna Demmerly, Lab Coordinator closed the container as soon as we entered the lab. Upon closer inspection of the container under the fume hood I could not see any label indicating if the contents were a hazardous waste or a label indicating the hazards of the container contents. According to Ms. Demmerly, the container was approximately half full. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Photo(s) 1. Observation_Image-202109141423252325141748.jpg 2. Observation_Image-202109141423302330161941.jpg 3. Observation_Image-202109141423482348394386.jpg Building: Reichardt Bldg. (Chemistry Labs)/Room 244/Fume hood Observation #: JJ1-OB-027 Contains CBI: No Date: 09/14/2021 While inspecting Room 244, I saw containers under the fume hood SAA. One was labeled as an unknown and, according to Mr. Deck, required a waste determination. The other containers were labeled as waste but were not labeled with the words "Hazardous Waste" or hazard indicators. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the containers of observed during the inspection were labeled with the words "Hazardous Waste" and hazard indicators. Mr. Deck also provided a copy of an inventory of the containers identified. The inventory includes the number of containers, container size, hazard determination and reference to photos taken of corrections made. Mr. Deck had previously stated in another email that the unknowns are truly unknown. In the email he says that once EHSRM Hazmat receives a waste pick up request for the items, they will be tested using the Haztech HazCat system to make the waste determination. Photo(s) 1. Observation_Image-202109141352565256177769.jpg 2. Observation_Image-20210914135307537429645.jpg Building: William A. O'Neill Bldg/Rm 143/Area adjacent to the fume hood Observation #: JJ1-OB-040 Contains CBI: No Date: 09/15/2021 While in Room 143, in a SAA adjacent to the fume hood I saw four, 5-gallon containers, that according to the container labeling, held waste formalin and one 5-gallon container that according to the container labeling, held waste iso-propyl alcohol. I also saw a fifth container of waste Formalin inside the fume hood that Mr Riley told me was waste Formalin. 22 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 At the time of the inspection, I did not observe a label on any of the six containers that indicated if they held a hazardous waste nor did a I see a label that indicated the hazards of the container contents. Following the inspection, Mr. Deck sent me an email, dated October 8, 2021, that included both written and photo documentation that the formalin waste containers located in the O'Neill 143 laboratory had been determined to be non-regulated. The formalin solution is a 10 percent solution containing 3.7 percent formaldehyde. While processing the samples the solution is further diluted. The one 5-gallon container of Isopropyl alcohol in 143 has been marked "Hazardous Waste" with the indicator word "Ignitable". Photo(s) 1. Observation_Image-202109150934303430222626.jpg 2. Observation_Image-2021091509344934491013479.jpg 3. Observation_Image-20210915093505355919714.jpg 4. Observation_Image-202109150939283928178605.jpg 5. Observation_Image-202109150939483948846045.jpg 6. Observation_Image-20210915094007407464980.jpg 7. Observation_Image-202109150945554555139147.jpg 8. Observation_Image-202109150946164616148456.jpg 9. Observation_Image-202109150946294629171889.jpg Records Review During the records review, I inspected the facility's hazardous waste manifests, land disposal restriction notices (LDR), and weekly hazardous waste inspections for the period of 09/13/2018 through 09/13/2021. I also reviewed training records that were provided to me following the inspection which are listed in the document log of this inspection report. SECTION III - AREAS OF CONCERN The presentation of areas of concern does not constitute a formal compliance determination or violation. Building: AFES Experimental Farm JJ1-OB-045 Area: AFES Maintenance Garage Sub-area: Used oil accumulation area Citations: Container not labeled with the words "Used Oil." Sections: Building: AFES Experimental Farm JJ1-OB-044 Area: AFES Maintenance Garage While at the AFES Maintenance Garage, I saw a clear plastic tote that contained waste aerosols. The tote was labeled with the Citations: 23 of 85 Sub-area: Waste aerosol SAA Sections: UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): words "Hazardous Waste" and "Waste Aerosol Cans." At the time of the inspection the tote was not marked with a hazard indicator. Building: Atkinson Power Plant JJ1-OB-018 Area: Maintenance Shop SAA Citations: The container was not labeled with the words HW and had no hazard indicator. JJ1-OB-019 At the time of the inspection, both containers held used turbine oil, and neither was labeled with the words "Used Oil." Citations: 09/13/2021 - 09/15/2021 Sub-area: Sections: Sections: Building: Atkinson Power Plant JJ1-OB-017 At the time of the inspection there was a box of universal waste lamps that was not closed. There was another box of waste fluorescent lamps that was not labeled as universal waste. Area: North stairwell leading to the old control room Citations: Building: Bldg. 799 Hazardous Materials Handling Facility (HMF) JJ1-OB-003 Area: North end of the building Two containers of universal waste lamps were not closed. Citations: JJ1-OB-004 24 of 85 Sub-area: Sections: Sub-area: Sections: UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): While in the HMF, I saw 14 small cardboard box containers, each containing waste light ballasts that contained a NiCad battery. At the time of the inspection these ballasts were not labeled with the words "Universal Waste - Batteries." Citations: JJ1-OB-005 At the time of the inspection, the lithium and Ni-Cad batteries were not labeled with the words "Universal Waste - Batteries." Citations: Building: Bldg. 799 Hazardous Materials Handling Facility (HMF) JJ1-OB-006 Area: South end of the building The ultraviolet bulb/lamp was not labeled with the words "Universal Waste - Lamp." Citations: Building: Bldg. 799 Hazardous Materials Handling Facility (HMF) JJ1-OB-007 Area: South end of the building Citations: Container of Universal Waste Lamps had been in storage for greater than one year. Building: Bldg. 799 Hazardous Materials Handling Facility (HMF) JJ1-OB-008 Area: South end of the building A box containing eight-foot Universal Waste -Lamps had been stored for greater than a year. Citations: 09/13/2021 - 09/15/2021 Sections: Sections: Sub-area: Sections: Sub-area: Area beside door leading out to the covered storage area (outside) Sections: Sub-area: Top of flammable storage cabinets Sections: 25 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Building: Bldg. FS306 Duckering Building JJ1-OB-010 Area: Room 448 - Alaska Stable Isotope Facility At the time of the inspection, none of the waste containers in the flammable storage cabinet, in Lab B, were labeled with the words "Hazardous Waste" or hazard indicators. Citations: Building: Bldg. FS306 Duckering Building JJ1-OB-012 Area: Room 442 - ASIF At the time of the inspection, neither container was labeled with the words "Hazardous Waste" or hazard indicators. Citations: The other fume hood had a small open container that was labeled Methanol waste. The container was open, and the vent hood was actively running. Citations: Building: Bldg. FS306 Duckering Building JJ1-OB-011 Area: Room 444 - ASIF The containers of waste in the fume hoods and in the cabinet beneath the fume hood were not labeled with the words, "Hazardous Waste" or marked with hazard indicators. Citations: Building: ELIF Bldg. 304 Area: Room 211 JJ1-OB-014 Additional waste containers that are not labeled as "Hazardous Waste" and have no hazard indicators. Citations: 09/13/2021 - 09/15/2021 Sub-area: Lab B Sections: Sub-area: Fume hood Sections: Sections: Sub-area: Fume hoods Sections: Sub-area: Yellow flammable storage cabinet Sections: 26 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Building: ELIF Bldg. 304 JJ1-OB-013 Area: Room 211 At the time of the inspection the container holding a mixture of waste Alaska crude oil, water, and Dichloromethane was not closed and in an actively running fume hood. The container was also not labeled with the words "Hazardous Waste" or a hazard indicator. Citations: JJ1-OB-015 Waste containers beneath fume hood in Rm 211 that are not labeled with the words "Hazardous Waste" and have no hazard indicator. Citations: 09/13/2021 - 09/15/2021 Sub-area: Fume hood SAA Sections: Sections: Building: ELIF Bldg. 304 JJ1-OB-016 Area: Room 211 Plastic tub of waste for pickup, on a table in the lab on the south side of the bldg., contained waste containers that were not labeled with the words "Hazardous Waste" or hazard indicators. Citations: Building: Facility Services JJ1-OB-020 Area: Customer Service The container of mixed (CFLs and batteries) universal waste was dated 3/16/20 and had been in accumulation for greater than a year. Citations: Building: Facility Services JJ1-OB-022 Area: Room 142 - Plumbing Shop Sub-area: East end of lab Sections: Sub-area: Sections: Sub-area: 27 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): The container was not labeled as either "Universal Waste Aerosols" or "Universal Waste - Batteries." Citations: Building: Facility Services JJ1-OB-023 Area: Room 141 Alarm/Electrical/HVAC SHOP Nine loose, waste aerosol cans were not packaged or labeled with the words "Universal Waste - Aerosols". Citations: Building: Facility Services Area: Paint Shop JJ1-OB-024 I saw a waste aerosol can in the trash. The aerosol can was not packaged or labeled with the words "Universal Waste Aerosol". Citations: Building: Facility Services Area: Paint Shop JJ1-OB-025 A step-can that was labeled, flammables and spent aerosol cans only, contained waste rags, absorbents, and two small open cans that held waste paint and thinner. The step-can was not labeled with the words "Hazardous Waste" or hazard indicators. Citations: Building: Facility Services JJ1-OB-026 Area: Paint Shop Step-can in paint booth that contained three waste aerosol cans was not labeled with the words "Universal Waste Aerosols". Citations: 28 of 85 09/13/2021 - 09/15/2021 Sections: Sub-area: Sections: Sub-area: Trash can next to deep sink Sections: Sub-area: Step-can outside Rm 152B - Paint Shop Tool & Paint Storage Sections: Sub-area: Paint booth Sections: UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Building: Facility Services JJ1-OB-021 Area: Room 140 - Transportation / Vehicle services Flammable storage cabinet containing waste aerosols was not labeled with the words "Universal Waste - Aerosols". Citations: Building: Irving I Bldg. Area: Rm 207 Lab JJ1-OB-043 While inspecting the SAA fume hood in Rm 207 Lab, I saw a small plastic tray that contained seven small plastic bottles of unknown wastes, requiring a waste determination. There was a handwritten note in the bottom of the tray that read, "These samples are of unknown origin or owner B. M. 8/25/19." Citations: Building: Irving I Bldg. JJ1-OB-042 Two containers holding unknown liquids require a waste determination. Area: Rm 409 Lab Citations: Container of waste HCL is not labeled with the words "Hazardous Waste" or a hazard indicator. Citations: Building: Murie Bldg. Biology (arctic) JJ1-OB-037 Area: Rm 318 I saw a plastic container that was labeled "Waste for pickup - Williams lab." Items in the container included universal waste batteries that were not Citations: 29 of 85 09/13/2021 - 09/15/2021 Sub-area: Waste Aerosol SAA Sections: Sub-area: Area just in front of the fume hood Sections: Sub-area: Fume hood Sections: Sections: Sub-area: Lab table Sections: UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): labeled with the words "Universal Waste - Batteries." Building: Murie Bldg. Biology (arctic) JJ1-OB-038 Area: Rm 318 I saw a container (Beaker) that held an unknown waste that had crystalized and required a waste determination. The container was not closed and not labeled. It was just sitting out on a table with other items. Citations: Another waste container was observed across from the previous table, with the unknown crystalized waste. The container was not labeled with the words "Hazardous Waste" or a hazard indicator. Citations: Building: Murie Bldg. Biology (arctic) JJ1-OB-039 Area: Rm 209 Prep Lab I saw a plastic tray under a fume hood that contained, according to Mr. Deck, vials of waste ethanol. The vials were not labeled with the words "Hazardous Waste" or a hazard indicator. Citations: Building: Murie Bldg. Biology (arctic) JJ1-OB-036 Area: Room 318B A container under the fume hood that was in another plastic container that was labeled as "Hazardous Waste Containment", was not labeled with the words "Hazardous Waste" or a hazard indicator. Citations: 30 of 85 09/13/2021 - 09/15/2021 Sub-area: Fume hood Sections: Sections: Sub-area: Fume hood Sections: Sub-area: Fume hood Sections: UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): A second fume hood in the same room (318B) also had containers of waste that were not labeled with the words "Hazardous Waste" or a hazard indicator. Citations: Building: Reichardt Bldg. (Chemistry Labs) JJ1-OB-034 Area: Rm 143 Chem Research Lab Citations: Waste container beneath fume hood was not labeled with the words "Hazardous Waste" or a hazard indicator. Building: Reichardt Bldg. (Chemistry Labs) JJ1-OB-032 Area: Room 191 Chem Research Lab Two, four-liter containers on a table, that contained an organic waste, were not labeled with the words "Hazardous Waste" or a hazard indicator. Citations: Building: Reichardt Bldg. (Chemistry Labs) JJ1-OB-027 Area: Room 244 I saw waste containers under the fume hood. One was labeled with the words "Unknown.". The other waste containers were not labeled with the words "Hazardous Waste" or hazard indicators. Citations: Building: Reichardt Bldg. (Chemistry Labs) JJ1-OB-028 Unknown waste in container under fume hood, dated 9/13/21. Area: Lab 246 Citations: 31 of 85 09/13/2021 - 09/15/2021 Sections: Sub-area: Cabinet beneath fume hood Sections: Sub-area: Table on right as you enter the lab Sections: Sub-area: Fume hood Sections: Sub-area: Fume hood Sections: UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Building: Reichardt Bldg. (Chemistry Labs) JJ1-OB-029 Area: Lab 242 Waste containers under fume hood were not labeled with the words "Hazardous Waste" or a hazard indicator. Citations: Building: Reichardt Bldg. (Chemistry Labs) JJ1-OB-030 Area: Lab 241 Waste containers in fume hood are not labeled with the words "Hazardous Waste" or a hazard indicator. Citations: Building: Reichardt Bldg. (Chemistry Labs) JJ1-OB-031 Area: Room 193 (Lab) At the time of the inspection the container was not labeled with the words "Hazardous Waste" or a hazard indicator. Citations: Building: Reichardt Bldg. (Chemistry Labs) JJ1-OB-033 Area: rm 132 Chem Lecture prep There were three waste containers under the fume hood that were not labeled with the words "Hazardous Waste" or a hazard indicator. Citations: Building: William A. O'Neill Bldg JJ1-OB-040 Area: Rm 143 There was a 5-gallon container which held waste Isopropyl alcohol that was not labeled with the words "Hazardous Waste" or a hazard indicator. Citations: 32 of 85 09/13/2021 - 09/15/2021 Sub-area: Fume hood Sections: Sub-area: Fume hood Sections: Sub-area: Fume hood Sections: Sub-area: Fume hood Sections: Sub-area: Area adjacent to the fume hood Sections: UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Building: Bldg. 799 - Hazardous Area: Covered storage area Materials Handling Facility (HMF) JJ1-OB-001 According to the labels on the containers, they held North Slope Crude Oil and were marked with DOT Class 3 hazard indicators. There were three containers and two of the three were also bulging at the top and bottom of the container. Citations: Building: Bldg. 799 - Hazardous Area: Covered storage area Materials Handling Facility (HMF) JJ1-OB-002 While still at the HMF, I saw seven, 55-gallon containers. According to Mr. Deck, five of the containers held Isopropanol, one held Methanol, and one held Ethanol. The containers were sitting inside a concrete bermed containment cell, in an accumulation of liquid which appeared to be rainwater and the bottoms were rusting. Citations: 09/13/2021 - 09/15/2021 Sub-area: Cell E Sections: Sub-area: Cell D Sections: SECTION IV - FOLLOW UP N/A Closing Conference At the conclusion of the inspection, I conducted a closing conference that was attended by those listed in the Attendees table, in Section I of this report. I thanked everyone for their time and cooperation during the inspection and began a review of the areas of concern (listed in Section III - Areas of Concern) that I observed during my inspection of the facility. I then explained the follow-up process that would take place once I finished the report. I explained they would receive a copy as would a case officer. I told them that the case officer would review the report to determine if any of my areas of concern documented violations. SECTION V - SAMPLING ACTIVITIES AND ANALYTICAL RESULTS - No sampling was conducted. 33 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): SECTION VI - LIST OF APPENDICES Photo Log Ins-202109131130533053192451.jpg 09/13/2021 11:30 AM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII View of universal waste lamp containers showing that one is not closed, and a couple are not structurally sound. Ins-202109131254055451086850.jpg 09/13/2021 12:54 PM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII View of the storage cabinet, showing the hazard indicator on the door of the cabinet vice marking the waste containers stored inside. Ins-2021091312542754271436304.jpg 09/13/2021 12:54 PM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII View of the storage cabinet, showing the hazard indicator on the door of the cabinet vice marking the waste containers stored inside. 34 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Ins-202109131254515451125540.jpg 09/13/2021 12:54 PM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII Close-up view of the storage cabinet, showing the hazard indicator on the door of the cabinet vice marking the waste containers stored inside. Ins-202109131451425142189023.jpg 09/13/2021 02:51 PM (AKT) Jon Jones Room 448 - Alaska Stable Isotope Facility/Lab B No CBI No PII View of SAA containers that are not labeled with the words "Hazardous Waste" or hazard indicators. Ins-202109131451515151185967.jpg 09/13/2021 02:51 PM (AKT) Jon Jones Room 448 - Alaska Stable Isotope Facility/Lab B No CBI No PII View of SAA containers that are not labeled with the words "Hazardous Waste" or hazard indicators. 09/13/2021 - 09/15/2021 35 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Ins-202109131452105210174785.jpg 09/13/2021 02:52 PM (AKT) Jon Jones Room 448 - Alaska Stable Isotope Facility/Lab B No CBI No PII View of SAA containers that are not labeled with the words "Hazardous Waste" or hazard indicators. Ins-202109131452285228148769.jpg 09/13/2021 02:52 PM (AKT) Jon Jones Room 448 - Alaska Stable Isotope Facility/Lab B No CBI No PII View of SAA containers that are not labeled with the words "Hazardous Waste" or hazard indicators. Ins-202109131452395239149235.jpg 09/13/2021 02:52 PM (AKT) Jon Jones Room 448 - Alaska Stable Isotope Facility/Lab B No CBI No PII View of SAA containers that are not labeled with the words "Hazardous Waste" or hazard indicators. 09/13/2021 - 09/15/2021 36 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Ins-202109131453425342117809.jpg 09/13/2021 02:53 PM (AKT) Jon Jones Room 448 - Alaska Stable Isotope Facility/Lab B No CBI No PII View of the flammable storage cabinet holding the SAA containers that are not labeled with the words "Hazardous Waste" or hazard indicators. Ins-2021091410151315132077621.jpg 09/14/2021 10:15 AM (AKT) Jon Jones Atkinson Power Plant/ Maintenance Shop SAA No CBI No PII View of the punctured aerosol cans. Ins-20210914110916916137382.jpg 09/14/2021 11:09 AM (AKT) Jon Jones Facility Services/Customer Service No CBI No PII View of the top of the container lid, showing that it was for the accumulation of batteries. 09/13/2021 - 09/15/2021 37 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Ins-202109141153415341228238.jpg 09/14/2021 11:53 AM (AKT) Jon Jones Paint Shop No CBI No PII View of the waste aerosol can that was in the trash can, adjacent to the deep sink, in the Paint Shop. Ins-20210914140332332123305.jpg 09/14/2021 02:03 PM (AKT) Jon Jones Lab 246/Fume hood No CBI No PII View of a SAA container not labeled with the words "Hazardous Waste" or a hazard indicator. Ins-20210914140338338121835.jpg 09/14/2021 02:03 PM (AKT) Jon Jones Lab 246/Vent hood No CBI No PII Close-up view of the same SAA container, seen in the previous photo (Ins20210914140332332123305.jpg), not labeled with the words "Hazardous Waste" or a hazard indicator. 38 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Ins-2021091414040040122059.jpg 09/14/2021 02:04 PM (AKT) Jon Jones Lab 246/Vent hood No CBI No PII View of another SAA container not labeled with the words "Hazardous Waste" or a hazard indicator. Ins-202109141438463846101035.jpg 09/14/2021 02:38 PM (AKT) Jon Jones Room 132 Chem Lecture prep/fume hood No CBI No PII Close-up view of the sign above the cabinet door, beneath the fume hood, that is used as the satellite accumulation area. Ins-202109141439143914192633.jpg 09/14/2021 02:39 PM (AKT) Jon Jones Room 132 Chem Lecture prep/fume hood No CBI No PII View of the sign (Seen to the right and just below the fume hood) above the cabinet door, beneath the fume hood, that is used as the satellite accumulation area. 09/13/2021 - 09/15/2021 39 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image20210915110050050204900.jpg 09/15/2021 11:00 AM (AKT) Jon Jones AFES Maintenance Garage/Used oil accumulation area No CBI No PII View of oil filter crusher, to the left of the used oil container. Observation_Image2021091511010010193314.jpg 09/15/2021 11:01 AM (AKT) Jon Jones AFES Maintenance Garage/Used oil accumulation area No CBI No PII View of a 5-gallon container beneath the oil filter crusher that contained used oil and was not labeled with the words "Used Oil." Observation_Image2021091511010818211622.jpg 09/15/2021 11:01 AM (AKT) Jon Jones AFES Maintenance Garage/Used oil accumulation area No CBI No PII Close-up view of a 5-gallon container beneath the oil filter crusher that contained used oil and was not labeled with the words "Used Oil." 40 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image20210915105208528172528.jpg 09/15/2021 10:52 AM (AKT) Jon Jones AFES Maintenance Garage/Waste aerosol SAA No CBI No PII View of a clear plastic tote that contained waste aerosols. The tote is labeled with the words, "Hazardous Waste" and "Waste Aerosol Cans" but is not marked with a hazard indicator. Observation_Image202109151052235223346221.jpg 09/15/2021 10:52 AM (AKT) Jon Jones AFES Maintenance Garage/Waste aerosol SAA No CBI No PII Close-up view of a clear plastic tote that contained waste aerosols. The tote is labeled with the words, "Hazardous Waste" and "Waste Aerosol Cans" but is not marked with a hazard indicator. Observation_Image202109141014131413241071.jpg 09/14/2021 10:14 AM (AKT) Jon Jones Atkinson Power Plant/ Maintenance Shop SAA No CBI No PII View of a SAA container, being used to accumulate residue, from puncturing waste aerosol cans, that is not labeled with the words "Hazardous Waste" or a hazard indicator. 41 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141014251425205672.jpg 09/14/2021 10:14 AM (AKT) Jon Jones Atkinson Power Plant/ Maintenance Shop SAA No CBI No PII Close-up view showing the container was not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109141014431443230892.jpg 09/14/2021 10:14 AM (AKT) Jon Jones Atkinson Power Plant/ Maintenance Shop SAA No CBI No PII View of the punctured aerosol cans next to SAA container, being used to accumulate residue, from puncturing waste aerosol cans, that is not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109141021212121252710.jpg 09/14/2021 10:21 AM (AKT) Jon Jones Atkinson Power Plant/ Maintenance Shop SAA No CBI No PII View of two containers, with red funnels, each holding used turbine oil, and neither is seen here labeled with the words "Used Oil." 42 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141021302130254863.jpg 09/14/2021 10:21 AM (AKT) Jon Jones Atkinson Power Plant/ Maintenance Shop SAA No CBI No PII Close-up view of two containers, with red funnels, each holding used turbine oil, and neither is seen here labeled with the words "Used Oil." Observation_Image202109140958245824330242.jpg 09/14/2021 09:58 AM (AKT) Jon Jones Atkinson Power Plant/North stairwell leading to the old control room No CBI No PII View of a box of universal waste lamps that is not closed, along with another box of universal waste lamps, just behind it, that is not labeled as universal waste. Observation_Image202109140958405840158073.jpg 09/14/2021 09:58 AM (AKT) Jon Jones Atkinson Power Plant/North stairwell leading to the old control room No CBI No PII Another view of the same box of universal waste lamps that is not closed, along with another box of universal waste lamps, just behind it, that is not labeled as universal waste. 43 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image20210914095903593165539.jpg 09/14/2021 09:59 AM (AKT) Jon Jones Atkinson Power Plant/North stairwell leading to the old control room No CBI No PII A close-up view showing that the second box of universal waste lamps is not labeled. Observation_Image202109131247474747150556.jpg 09/13/2021 12:47 PM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/Flammable and Corrosive storage cabinets No CBI No PII View of the storage cabinets. Wastes inside the cabinets were marked with labels indicating that they were hazardous waste but did not include a hazard indicator. Each cabinet was marked with a hazard indicator. Observation_Image202109131248094891735814.jpg 09/13/2021 12:48 PM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/Flammable and Corrosive storage cabinets No CBI No PII View of wastes inside the cabinets that were marked with labels indicating that they were hazardous waste but did not include a hazard indicator. Each cabinet was marked with a hazard indicator. 44 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image2021091312533453341070489.jpg 09/13/2021 12:53 PM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/Flammable and Corrosive storage cabinets No CBI No PII Another view of the storage cabinets that are marked with a hazard indicator. Observation-Image2021091311294929491559795.jpg 09/13/2021 11:29 AM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII View of waste fluorescent lamp containers, showing two that were not closed. Observation_Image202109131130013011509344.jpg 09/13/2021 11:30 AM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII Close-up view of waste fluorescent lamp containers, showing two that were not closed. 45 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image2021091311301930191336300.jpg 09/13/2021 11:30 AM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII Another close-up view of waste fluorescent lamp containers, showing two that were not closed. Observation_Image2021091311383238321576453.jpg 09/13/2021 11:38 AM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII View of 14 small cardboard box containers in a white 5-gallon bucket that held waste light ballasts that each contained a Ni-Cad battery. The ballasts were not labeled as universal waste batteries. Observation_Image202109131138533853122851.jpg 09/13/2021 11:38 AM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII Close-up view of the bucket of ballasts containing batteries that were not labeled with the words, "Universal Waste - Batteries." 46 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image20210913113905395146294.jpg 09/13/2021 11:39 AM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII Another view of the same ballasts seen in the previous two photos. Observation_Image2021091311534453441562417.jpg 09/13/2021 11:53 AM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII View of waste batteries that were not labeled as universal waste. Observation_Image202109131154035431710847.jpg 09/13/2021 11:54 AM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII Close-up view of the same unlabeled waste batteries seen in the previous photo. 47 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109131156095691475895.jpg 09/13/2021 11:56 AM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/North end of the building No CBI No PII Another close-up view of the same unlabeled waste batteries seen in the previous two photos. Observation_Image2021091312232023201690922.jpg 09/13/2021 12:23 PM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/South end of the building No CBI No PII View of ultraviolet bulb/lamp was not labeled as universal waste. Observation_Image2021091312233823381658533.jpg 09/13/2021 12:23 PM (AKT) Jon Jones Bldg. 799 - Hazardous Materials Handling Facility (HMF)/South end of the building No CBI No PII Another view of the same ultraviolet bulb/lamp that was not labeled as universal waste. 48 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image2021091311132513251898201.jpg 09/13/2021 11:13 AM (AKT) Jon Jones Covered storage area/Cell D No CBI No PII View of seven, 55-gallon containers that according to the labels contained Isopropanol (5), Methanol (1), and Ethanol (1). The containers were sitting in an accumulation of liquid, that appeared to be rainwater, and the bottoms were rusting. Observation_Image2021091311135613561859018.jpg 09/13/2021 11:13 AM (AKT) Jon Jones Covered storage area/Cell D No CBI No PII Close-up view of the rusting containers. Observation_Image2021091311141314131624579.jpg 09/13/2021 11:14 AM (AKT) Jon Jones Covered storage area/Cell D No CBI No PII Close-up view of the rusting containers. 09/13/2021 - 09/15/2021 49 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109131103443441502549.jpg 09/13/2021 11:03 AM (AKT) Jon Jones Covered storage area/Cell E No CBI No PII View of rusting and bulging containers that hold North Slope Crude Oil and are marked with DOT Class 3 hazard indicators. Observation_Image202109131104154151421441.jpg 09/13/2021 11:04 AM (AKT) Jon Jones Covered storage area/Cell E No CBI No PII Close-up view of the labeling on the rusting and bulging containers. Observation_Image202109131104354351602830.jpg 09/13/2021 11:04 AM (AKT) Jon Jones Covered storage area/Cell E No CBI No PII Another close-up view of the rusting and bulging containers. 09/13/2021 - 09/15/2021 50 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image20210914110810810122884.jpg 09/14/2021 11:08 AM (AKT) Jon Jones Facility Services/Customer Service No CBI No PII View of a universal waste battery container that contained waste CFLs and was dated 3/16/20. Observation_Image20210914110818818169663.jpg 09/14/2021 11:08 AM (AKT) Jon Jones Facility Services/Customer Service No CBI No PII Close-up view of a universal waste battery container that contained waste CFLs and was dated 3/16/20. Observation_Image2021091411083283297909.jpg 09/14/2021 11:08 AM (AKT) Jon Jones Facility Services/Customer Service No CBI No PII Close-up view of the container label. The container is seen here dated 3/16/20 and has been in accumulation for greater than a year. 51 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141144274427176096.jpg 09/14/2021 11:44 AM (AKT) Jon Jones Facility Services/Room 141 Alarm/Electrical/HVAK SHOP No CBI No PII View of nine loose waste aerosol cans that were not labeled with the words "Universal Waste Aerosols." Observation_Image202109141144354435183028.jpg 09/14/2021 11:44 AM (AKT) Jon Jones Facility Services/Room 141 Alarm/Electrical/HVAK SHOP No CBI No PII Close-up view of seven of the nine loose waste aerosol cans that were not labeled with the words "Universal Waste - Aerosols." Observation_Image202109141144394439129943.jpg 09/14/2021 11:44 AM (AKT) Jon Jones Facility Services/Room 141 Alarm/Electrical/HVAK SHOP No CBI No PII Close-up view of the other two loose waste aerosol cans that were not labeled with the words "Universal Waste - Aerosols." 52 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141131433143126603.jpg 09/14/2021 11:31 AM (AKT) Jon Jones Facility Services/Room 142 - Plumbing Shop No CBI No PII View of a step-can that is holding a waste aerosol can and a waste battery. Observation_Image202109141131523152206017.jpg 09/14/2021 11:31 AM (AKT) Jon Jones Facility Services/Room 142 - Plumbing Shop No CBI No PII Close-up view of the step-can showing that it is labeled with the words "Flammables & Spent Aerosol Cans Only." Observation_Image202109141132443244881674.jpg 09/14/2021 11:32 AM (AKT) Jon Jones Facility Services/Room 142 - Plumbing Shop No CBI No PII View of the contents of the step-can which include a waste aerosol can, a small, leaking lithium battery, and two pieces of "Nicorette" gum. 53 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141410241024189214.jpg 09/14/2021 02:10 PM (AKT) Jon Jones Lab 241/Fume hood No CBI No PII A view of SAA wastes in containers that are not labeled with the words "Hazardous Waste" or hazard indicators. Observation_Image202109141410391039433284.jpg 09/14/2021 02:10 PM (AKT) Jon Jones Lab 241/Fume hood No CBI No PII Additional view of the same SAA wastes in containers that are not labeled with the words "Hazardous Waste" or hazard indicators. Observation_Image20210914140128128124477.jpg 09/14/2021 02:01 PM (AKT) Jon Jones Lab 242/Fume hood No CBI No PII Waste containers under fume hood that are not labeled with the words "Hazardous Waste" or hazard indicators. 54 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image20210914140134134164458.jpg 09/14/2021 02:01 PM (AKT) Jon Jones Lab 242/Fume hood No CBI No PII Close-up view of the same waste containers under fume hood that are not labeled with the words "Hazardous Waste" or hazard indicators. Observation_Image20210914140141141115246.jpg 09/14/2021 02:01 PM (AKT) Jon Jones Lab 242/Fume hood No CBI No PII Another close-up view of the same waste containers under fume hood that are not labeled with the words "Hazardous Waste" or hazard indicators. Observation_Image20210914135806586145373.jpg 09/14/2021 01:58 PM (AKT) Jon Jones Lab 246/Fume hood No CBI No PII View of an unknown waste in containers under fume hood. Containers under fume hood are not labeled with the words "Hazardous Waste" or hazard indicators. 55 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141358275827417387.jpg 09/14/2021 01:58 PM (AKT) Jon Jones Lab 246/Fume hood No CBI No PII Close-up view of the unknown waste in container under vent hood. Dated 9/13/21. Containers under fume hood is not labeled with the words "Hazardous Waste" or hazard indicator. Observation_Image20210914120759759184539.jpg 09/14/2021 12:07 PM (AKT) Jon Jones Paint Shop/Paint booth No CBI No PII View of an open step-can, inside of a paint booth, that contained three waste aerosol cans and was not labeled as "Universal Waste Aerosols." Observation_Image2021091412080888205442.jpg 09/14/2021 12:08 PM (AKT) Jon Jones Paint Shop/Paint booth No CBI No PII Close-up view of the same three waste aerosol cans seen in the previous photo. 09/13/2021 - 09/15/2021 56 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image20210914120821821213790.jpg 09/14/2021 12:08 PM (AKT) Jon Jones Paint Shop/Paint booth No CBI No PII Another close-up view of the same three waste aerosol cans seen in the previous photo. Observation_Image202109141159105910204634.jpg 09/14/2021 11:59 AM (AKT) Jon Jones Paint Shop/Step-can outside Rm 152B - Paint Shop Tool & Paint Storage No CBI No PII View of step-can labeled "Flammables & Spent Aerosol Cans Only." The step-can contained waste rags, absorbents, and two small open cans that held waste paint and thinner. The open cans of waste paint and thinner are seen here in front of the step-can. Observation_Image202109141159185918211624.jpg 09/14/2021 11:59 AM (AKT) Jon Jones Paint Shop/Step-can outside Rm 152B - Paint Shop Tool & Paint Storage No CBI No PII Close-up view of the waste paint and thinner cans that were removed from the step-can. 57 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141159365936182170.jpg 09/14/2021 11:59 AM (AKT) Jon Jones Paint Shop/Step-can outside Rm 152B - Paint Shop Tool & Paint Storage No CBI No PII Another close-up view of the waste paint and thinner cans that were removed from the stepcan. Observation_Image202109141152525252170290.jpg 09/14/2021 11:52 AM (AKT) Jon Jones Paint Shop/Trash can next to deep sink No CBI No PII View of a waste aerosol can in the trash. Observation_Image20210914115300530174973.jpg 09/14/2021 11:53 AM (AKT) Jon Jones Paint Shop/Trash can next to deep sink No CBI No PII Another view of the same waste aerosol can in the trash. 58 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image20210914115307537175611.jpg 09/14/2021 11:53 AM (AKT) Jon Jones Paint Shop/Trash can next to deep sink No CBI No PII Close-up view of the same waste aerosol can in the trash. Observation_Image202109141436583658159620.jpg 09/14/2021 02:36 PM (AKT) Jon Jones rm 132 Chem Lecture prep/fume hood No CBI No PII View of three waste containers under fume hood. Containers under fume hood that are not labeled with the words "Hazardous Waste" or hazard indicators. Observation_Image20210914143808388702898.jpg 09/14/2021 02:38 PM (AKT) Jon Jones rm 132 Chem Lecture prep/fume hood No CBI No PII Close-up view of the container log sheet which shows a detailed list of what's in the container. 09/13/2021 - 09/15/2021 59 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141438213821718393.jpg 09/14/2021 02:38 PM (AKT) Jon Jones rm 132 Chem Lecture prep/fume hood No CBI No PII Close-up view of the container log sheet which shows a detailed list of what's in the container. Observation_Image202109141448504850173549.jpg 09/14/2021 02:48 PM (AKT) Jon Jones Rm 143 Chem Research Lab/Cabinet beneath fume hood No CBI No PII View of additional waste containers beneath fume hood that are not labeled with the words "Hazardous Waste" or hazard indicators. Observation_Image20210914144900490138975.jpg 09/14/2021 02:49 PM (AKT) Jon Jones Rm 143 Chem Research Lab/Cabinet beneath fume hood No CBI No PII Close-up view of the additional waste containers beneath fume hood that are not labeled with the words "Hazardous Waste" or hazard indicators. 60 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109150934303430222626.jpg 09/15/2021 09:34 AM (AKT) Jon Jones Rm 143/Area adjacent to the fume hood No CBI No PII View of five, 5-gallon containers, four of which held waste Formalin and one that held waste Isopropyl alcohol. The container of waste Isopropyl alcohol was not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image2021091509344934491013479.jpg 09/15/2021 09:34 AM (AKT) Jon Jones Rm 143/Area adjacent to the fume hood No CBI No PII Close-up view of some of the same containers seen in the previous photo. Observation_Image20210915093505355919714.jpg 09/15/2021 09:35 AM (AKT) Jon Jones Rm 143/Area adjacent to the fume hood No CBI No PII Close-up view of the container of waste Isopropyl alcohol (Seen here on the left) was not labeled with the words "Hazardous Waste" or a hazard indicator. 61 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109151031293129134715.jpg 09/15/2021 10:31 AM (AKT) Jon Jones Rm 207 Lab/Area just in front of the fume hood No CBI No PII View of a small plastic tray that contained seven small plastic bottles of unknown wastes. There was a handwritten note in the bottom of the tray that read, "These samples are of unknown origin or owner B. M. 8/25/19." Observation_Image202109151031473147400253.jpg 09/15/2021 10:31 AM (AKT) Jon Jones Rm 207 Lab/Area just in front of the fume hood No CBI No PII Another view of the same small plastic tray that contained seven small plastic bottles of unknown wastes. There was a handwritten note in the bottom of the tray that read, "These samples are of unknown origin or owner B. M. 8/25/19." Observation_Image202109141550265026110001.jpg 09/14/2021 03:50 PM (AKT) Jon Jones Rm 209 Prep Lab/Fume hood No CBI No PII View of plastic tray under a fume hood that contained vials of waste ethanol. The vials were not labeled with the words "Hazardous Waste" or a hazard indicator. 62 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141550365036396655.jpg 09/14/2021 03:50 PM (AKT) Jon Jones Rm 209 Prep Lab/Fume hood No CBI No PII Another view of the same plastic tray under a fume hood that contained vials of waste ethanol. The vials were not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109141550525052376606.jpg 09/14/2021 03:50 PM (AKT) Jon Jones Rm 209 Prep Lab/Vent hood No CBI No PII Close-up view of the same vials seen in the previous two photos. Observation_Image202109141526422642157943.jpg 09/14/2021 03:26 PM (AKT) Jon Jones Rm 318/Lab table No CBI No PII View of a plastic container that was labeled "Waste for pickup - Williams lab." Items in the container included universal waste batteries that were not labeled. At least one battery was a lithium battery. 63 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141526492649132209.jpg 09/14/2021 03:26 PM (AKT) Jon Jones Rm 318/Lab table No CBI No PII Another view of the same container seen in the previous photo. Observation_Image20210914152701271114171.jpg 09/14/2021 03:27 PM (AKT) Jon Jones Rm 318/Lab table No CBI No PII Close-up view of one of the waste batteries (Purple) inside of a device that was in the plastic container seen in the previous two photos. Observation_Image202109141534143414361930.jpg 09/14/2021 03:34 PM (AKT) Jon Jones Rm 318/Fume hood No CBI No PII View of a plastic tub inside of a fume hood. The plastic tub held six smaller containers all labeled "Unknown" waste. The containers were not labeled with the words "Hazardous Waste" or a hazard indicator. 64 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141534353435311596.jpg 09/14/2021 03:34 PM (AKT) Jon Jones Rm 318/Fume hood No CBI No PII View of box containing a bottle of waste pH 1.68 buffer solution. The bottle of waste pH 1.68 buffer solution was not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image20210914153806386218688.jpg 09/14/2021 03:38 PM (AKT) Jon Jones Rm 318/Fume hood No CBI No PII View of an unidentified waste that had crystalized. The container it is in is not closed and not labeled. Observation_Image2021091415382438242645295.jpg 09/14/2021 03:38 PM (AKT) Jon Jones Rm 318/Fume hood No CBI No PII Closer view of the unidentified waste that had crystalized. The container it is in is not closed and not labeled. 65 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image2021091415384738472327055.jpg 09/14/2021 03:38 PM (AKT) Jon Jones Rm 318/Fume hood No CBI No PII Close-up view of the unidentified waste that had crystalized. The container it is in is not closed and not labeled. Observation_Image202109141541504150167757.jpg 09/14/2021 03:41 PM (AKT) Jon Jones Rm 318/Fume hood No CBI No PII View of another waste container, seen here with a yellow label, was found across from the previous table and was not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109141542104210574413.jpg 09/14/2021 03:42 PM (AKT) Jon Jones Rm 318/Fume hood No CBI No PII Close-up view of the same waste container seen in the previous photo. 09/13/2021 - 09/15/2021 66 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109151013481348192813.jpg 09/15/2021 10:13 AM (AKT) Jon Jones Rm 409 Lab/Fume hood No CBI No PII View of a fume hood containing a waste that is not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image20210915101401141390885.jpg 09/15/2021 10:14 AM (AKT) Jon Jones Rm 409 Lab/Fume hood No CBI No PII View of the container of waste HCL, seen here with the blue cap, that is not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109151014271427351004.jpg 09/15/2021 10:14 AM (AKT) Jon Jones Rm 409 Lab/Fume hood No CBI No PII Close-up view of the container of waste HCL, seen here with the blue cap, that is not labeled with the words "Hazardous Waste" or a hazard indicator. 67 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image20210915101509159161688.jpg 09/15/2021 10:15 AM (AKT) Jon Jones Rm 409 Lab/Fume hood No CBI No PII View of two containers, seen behind the container with the blue cap, holding unknown liquids and requiring a waste determination. Observation_Image202109151015251525229796.jpg 09/15/2021 10:15 AM (AKT) Jon Jones Rm 409 Lab/Fume hood No CBI No PII Close-up view of the two containers, seen behind the container with the blue cap, holding unknown liquids. Observation_Image202109141117571757163500.jpg 09/14/2021 11:17 AM (AKT) Jon Jones Room 140 - Transportation / Vehicle services/Waste Aerosol SAA No CBI No PII View of flammable storage cabinet containing waste aerosols that is not labeled as "Universal Waste - Aerosols." 68 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image20210914111807187244898.jpg 09/14/2021 11:18 AM (AKT) Jon Jones Room 140 - Transportation / Vehicle services/Waste Aerosol SAA No CBI No PII View of the waste aerosol cans inside the flammable storage cabinet. Observation_Image202109141118131813126734.jpg 09/14/2021 11:18 AM (AKT) Jon Jones Room 140 - Transportation / Vehicle services/Waste Aerosol SAA No CBI No PII Close-up view of the labeling on the outside of the flammable storage cabinet. Observation_Image202109141430263026203754.jpg 09/14/2021 02:30 PM (AKT) Jon Jones Room 191 Chem Research Lab/Table on right as you enter the lab No CBI No PII View of two four-liter containers on the table that contained an organic waste. The containers were not labeled with the words "Hazardous Waste" or a hazard indicator. 69 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141430383038739497.jpg 09/14/2021 02:30 PM (AKT) Jon Jones Room 191 Chem Research Lab/Table on right as you enter the lab No CBI No PII Close-up view of two four-liter containers on the table that contained an organic waste. The containers were not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109141423252325141748.jpg 09/14/2021 02:23 PM (AKT) Jon Jones Room 193 (Lab)/Fume hood No CBI No PII View of waste container, marked with red tape, that was not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109141423302330161941.jpg 09/14/2021 02:23 PM (AKT) Jon Jones Room 193 (Lab)/Fume hood No CBI No PII Close-up view of waste container, marked with red tape, that was not labeled with the words "Hazardous Waste" or a hazard indicator. 70 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141423482348394386.jpg 09/14/2021 02:23 PM (AKT) Jon Jones Room 193 (Lab)/Fume hood No CBI No PII Another close-up view of waste container, marked with red tape, that was not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109131628342834180200.jpg 09/13/2021 04:28 PM (AKT) Jon Jones Room 211/East end of lab No CBI No PII View of a plastic tub of waste that is marked as "Hazardous waste for pick-up" on a table in the lab on the south side of the bldg. None of the containers in the tub are labeled with the words "Hazardous Waste" and not all were marked with a hazard indicator. Observation_Image2021091316094094081809.jpg 09/13/2021 04:09 PM (AKT) Jon Jones Room 211/Fume hood SAA No CBI No PII View of a container holding a mixture of waste Alaska crude oil, water, and Dichloromethane. At the time of the inspection the container was not closed and in an actively running vent hood. The container was also not labeled with the words "Hazardous Waste" or a hazard indicator. 71 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image20210913161110111095185.jpg 09/13/2021 04:11 PM (AKT) Jon Jones Room 211/Fume hood SAA No CBI No PII View of the same container, seen in the previous photo, after being closed. Observation_Image20210913162340234079439.jpg 09/13/2021 04:23 PM (AKT) Jon Jones Room 211/Fume hood SAA No CBI No PII View of waste containers beneath fume hood in Rm 211 that are not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image20210913162355235590848.jpg 09/13/2021 04:23 PM (AKT) Jon Jones Room 211/Fume hood SAA No CBI No PII Close-up view of the same waste containers beneath fume hood in Rm 211 that are not labeled with the words "Hazardous Waste" or a hazard indicator. 72 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109131617221722172144.jpg 09/13/2021 04:17 PM (AKT) Jon Jones Room 211/Yellow flammable storage cabinet No CBI No PII View of additional waste containers that are not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109131617461746190186.jpg 09/13/2021 04:17 PM (AKT) Jon Jones Room 211/Yellow flammable storage cabinet No CBI No PII View of additional waste containers that are not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109141352565256177769.jpg 09/14/2021 01:52 PM (AKT) Jon Jones Room 244/Fume hood No CBI No PII View of waste container under the fume hood, labeled with green tape as an unknown and is not labeled with the words "Hazardous Waste" or a hazard indicator. 73 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image20210914135307537429645.jpg 09/14/2021 01:53 PM (AKT) Jon Jones Room 244/Fume hood No CBI No PII Close-up view of waste container under the fume hood, labeled with green tape as an unknown and is not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109141516161616469495.jpg 09/14/2021 03:16 PM (AKT) Jon Jones Room 318B/Fume hood No CBI No PII View of container under fume hood that is in another plastic tub. The plastic tub is labeled as Hazardous Waste Containment. The container in the tub is not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109141516371637518156.jpg 09/14/2021 03:16 PM (AKT) Jon Jones Room 318B/Fume hood No CBI No PII The container in the tub, seen in the previous photo, is not labeled with the words "Hazardous Waste" or a hazard indicator. 74 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109141519261926135089.jpg 09/14/2021 03:19 PM (AKT) Jon Jones Room 318B/Fume hood No CBI No PII View of a second fume hood in the same room (318B) also had containers of waste that were not labeled with the words "Hazardous Waste" or a hazard indicator. The containers include the large plastic container in the rear of the fume hood, small bottle of dark liquid marked with red tape, and the small white container with the black cap. Observation_Image202109141519381938540844.jpg 09/14/2021 03:19 PM (AKT) Jon Jones Room 318B/Fume hood No CBI No PII Close-up view of the small white container with the black cap that is not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109141519581958505990.jpg 09/14/2021 03:19 PM (AKT) Jon Jones Room 318B/Fume hood No CBI No PII Close-up view of the large white container and the small bottle marked with red tape that are not labeled with the words "Hazardous Waste" or hazard indicators. 75 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109131520542054219516.jpg 09/13/2021 03:20 PM (AKT) Jon Jones Room 442 - ASIF/Fume hood No CBI No PII View of waste containers under fume hood that are not labeled with the words "Hazardous Waste" or hazard indicators. Observation_Image20210913152406246378035.jpg 09/13/2021 03:24 PM (AKT) Jon Jones Room 442 - ASIF/Fume hood No CBI No PII View of a small open container that was labeled Methanol waste. The container was not closed, and the vent hood was actively running. Observation_Image202109131510591059185091.jpg 09/13/2021 03:10 PM (AKT) Jon Jones Room 444 - ASIF/Fume hoods No CBI No PII View of HCL waste container under fume hood that is not labeled with the words "Hazardous Waste" or hazard indicators. 76 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109131511171117177003.jpg 09/13/2021 03:11 PM (AKT) Jon Jones Room 444 - ASIF/Fume hoods No CBI No PII View of waste container marked with orange tape under fume hood that is not labeled with the words "Hazardous Waste" or a hazard indicator. Observation_Image202109131511321132164247.jpg 09/13/2021 03:11 PM (AKT) Jon Jones Room 444 - ASIF/Fume hoods No CBI No PII View of waste container marked with blue tape under fume hood that is not labeled with the words "Hazardous Waste" or hazard indicators. Observation_Image202109131449324932875554.jpg 09/13/2021 02:49 PM (AKT) Jon Jones Room 448 - Alaska Stable Isotope Facility/Lab B No CBI No PII View of the waste containers in the flammable storage cabinet, in Lab B, that were not labeled with the words "Hazardous Waste" or hazard indicators. 77 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109131450205020927558.jpg 09/13/2021 02:50 PM (AKT) Jon Jones Room 448 - Alaska Stable Isotope Facility/Lab B No CBI No PII Close-up view of the waste containers in the flammable storage cabinet, in Lab B, that were not labeled with the words "Hazardous Waste" or hazard indicators. Observation_Image202109131451105110179778.jpg 09/13/2021 02:51 PM (AKT) Jon Jones Room 448 - Alaska Stable Isotope Facility/Lab B No CBI No PII Close-up view of the waste containers in the flammable storage cabinet, in Lab B, that were not labeled with the words "Hazardous Waste" or hazard indicators. Observation_Image202109131231323132181086.jpg 09/13/2021 12:31 PM (AKT) Jon Jones South end of the building/Area beside door leading out to the covered storage area (outside) No CBI No PII View of a box containing waste fluorescent lamps that has been in storage for greater than one year. 78 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109131231513151123982.jpg 09/13/2021 12:31 PM (AKT) Jon Jones South end of the building/Area beside door leading out to the covered storage area (outside) No CBI No PII Another view of the same box containing waste fluorescent lamps that has been in storage for greater than one year. Observation_Image20210913123158315899644.jpg 09/13/2021 12:31 PM (AKT) Jon Jones South end of the building/Area beside door leading out to the covered storage area (outside) No CBI No PII Close-up view of the label on the same box containing waste fluorescent lamps that has been in storage for greater than one year. Observation_Image20210913123808388193531.jpg 09/13/2021 12:38 PM (AKT) Jon Jones South end of the building/Top of flammable storage cabinets No CBI No PII View of a box containing eight-foot waste fluorescent lamps that is seen here on top of the yellow flammable storage cabinet. The waste lamps have been stored for greater than a year. 79 of 85 09/13/2021 - 09/15/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): Observation_Image202109131238233823178086.jpg 09/13/2021 12:38 PM (AKT) Jon Jones South end of the building/Top of flammable storage cabinets No CBI No PII Another view of the same box containing waste fluorescent lamps that has been in storage for greater than one year. 09/13/2021 - 09/15/2021 Observation_Image202109131238313831145309.jpg 09/13/2021 12:38 PM (AKT) Jon Jones South end of the building/Top of flammable storage cabinets No CBI No PII Close-up view of the label on the same box containing waste fluorescent lamps that has been in storage for greater than one year. Document Log Document Type Personnel Training Personnel Training Personnel Training Personnel Training Other - Building Directory Document Name Contains Contains Uploaded By CBI PII Hazardous Waste Management No No Jon Jones Initital Training.xlsx Hazardous Waste Management No No Jon Jones Refresher Training.xlsx Intro-to-Hazardous-Waste- No No Jon Jones Management_December-2017.pptx Refresher-Hazardous-WasteManagement_Sept-2019.pptx No No Jon Jones UAF Building Renumbering Sheet1.pdf No No Jon Jones Date Received 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 80 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Other - List of UAF waste pickup report.pdf accumulation points No No Jon Jones Process 215276-01-862-V201 PIPING AND No No Jon Jones Description/Flow INSTRUMENT DIAGRAM Diagram DUSTMASTER 40 TPH SII SYSTEM.pdf Process 215276-01-E103-02 ASH HANDLING No No Jon Jones Description/Flow SYSTEM P&ID.pdf Diagram Process 215276-01-E103-03 ASH HANDLING No No Jon Jones Description/Flow SYSTEM P&ID.pdf Diagram Process 215276-01-E803-01 P&ID ASH No No Jon Jones Description/Flow HANDLING SYSTEM - ASH SILO - Diagram SHEET 1.pdf Process 215276-01-E803-02 P&ID ASH No No Jon Jones Description/Flow HANDLING SYSTEM - ASH SILO - Diagram SHEET 2.pdf Process 215276-01-E803-03 P&ID ASH No No Jon Jones Description/Flow HANDLING SYSTEM - ASH SILO - Diagram SHEET 3.pdf Process 215276-01-E810-08 EQUIPMENT No No Jon Jones Description/Flow ARRANGEMENT FLY ASH SILO.pdf Diagram Process B6075-0901 FMC COAL HANLDING No No Jon Jones Description/Flow P&ID SHEET 1 OF 3.pdf Diagram Process B6075-0902 FMC COAL HANDLING No No Jon Jones Description/Flow P&ID SHEET 2 OF 3.pdf Diagram Process B6075-0903 FMC COAL HANDLING No No Jon Jones Description/Flow P&ID SHEET 3 OF 3.pdf Diagram Process Description/Flow Diagram CHP.pdf No No Jon Jones Other - Waste UAF Monthly Waste Tally 2020.xlsx No No Jon Jones generated by month Other - Waste UAF Monthly Waste Tally 2021.xlsx No No Jon Jones generated by month Other - Atkinson Bldg. UAF Utilities - EMAIL.pdf - Response email to AOC's No No Jon Jones Other - Atkinson Bldg. IMG_4082.JPG - RTC photo documentation No No Jon Jones 81 of 85 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Other - Atkinson Bldg. IMG_4083.JPG - RTC photo documentation No No Jon Jones Other - Atkinson Bldg. IMG_4084.JPG - RTC photo documentation No No Jon Jones Other - Atkinson Bldg. IMG_4085.JPG - RTC photo documentation No No Jon Jones Other - Atkinson Bldg. IMG_4087.JPG - RTC photo documentation No No Jon Jones Other - Atkinson Bldg. IMG_4091.JPG - RTC photo documentation No No Jon Jones Other - Atkinson Bldg. IMG_4093.JPG - RTC photo documentation No No Jon Jones Other - Atkinson Bldg. IMG_4230.JPG - RTC photo documentation No No Jon Jones Other - Atkinson Bldg. UAF Utilities Waste Pickup - Waste pick-up request.xlsx request No No Jon Jones Other - Duckering UAF Duckering Building - EMAIL.pdf No No Jon Jones Bldg. - Response email to AOC's Other - Duckering Bldg. - RTC photo documentation IMG_3905.JPG No No Jon Jones Other - Duckering Bldg. - RTC photo documentation IMG_3907.JPG No No Jon Jones Other - Duckering Bldg. - RTC photo documentation IMG_4185.JPG No No Jon Jones Other - Duckering Bldg. - RTC photo documentation IMG_4186.JPG No No Jon Jones Other - Duckering Bldg. - RTC photo documentation IMG_4190.JPG No No Jon Jones Other - Duckering Bldg. - RTC photo documentation IMG_4219.JPG No No Jon Jones 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 82 of 85 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Other - Duckering Duckering Waste Inventory.xlsx No No Jon Jones Bldg. - Waste inventory Other - ELIF Bldg. - ELIF 211 Suite Waste Inventory.xlsx No No Jon Jones Waste inventory Other - ELIF Bldg. Response email to AOC's UAF ELIF Building - EMAIL.pdf No No Jon Jones Other - ELIF Bldg. RTC photo documentation IMG_4201.JPG No No Jon Jones Other - ELIF Bldg. RTC photo documentation IMG_4203.JPG No No Jon Jones Other - ELIF Bldg. RTC photo documentation IMG_4204.JPG No No Jon Jones Other - ELIF Bldg. RTC photo documentation IMG_4216.JPG No No Jon Jones Other - Farm UAF Farm Maintenance Shop - No No Jon Jones Maintenance shop - EMAIL.pdf Response email to AOC's Other - Farm Maintenance shop RTC photo documentation IMG_4127.JPG No No Jon Jones Other - Farm Maintenance shop RTC photo documentation IMG_4129.JPG No No Jon Jones Other - HMF Facility - UAF HazMat Handling Facility - No No Jon Jones Response email to EMAIL.pdf AOC's Universal Waste Disposal Receipts UAF Lamp Shipments BOL.pdf No No Jon Jones Other - HMF Facility - IMG_4208.JPG RTC photo documentation No No Jon Jones Other - HMF Facility - IMG_4210.JPG RTC photo documentation No No Jon Jones Other - HMF Facility - IMG_4211.JPG RTC photo documentation No No Jon Jones 83 of 85 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Other - HMF Facility - IMG_4228.JPG RTC photo documentation No No Jon Jones Other - HMF Facility - UAF HMF Lamp Containers Closed No No Jon Jones RTC photo I.pdf documentation Other - Murie Bldg. & UAF Murie and Irving I Buildings - No No Jon Jones Irving I Bldg. - EMAIL.pdf Response email to AOC's Other - Murie Bldg. & Murie and Irving I Bldg Waste Irving I Bldg. - Waste Inventory.xlsx inventory No No Jon Jones Other - Murie Bldg. & IMG_4192.JPG Irving I Bldg. - RTC photo documentation No No Jon Jones Other - Murie Bldg. & IMG_4193.JPG Irving I Bldg. - RTC photo documentation No No Jon Jones Other - Murie Bldg. & IMG_4194.JPG Irving I Bldg. - RTC photo documentation No No Jon Jones Other - Murie Bldg. & IMG_4196.JPG Irving I Bldg. - RTC photo documentation No No Jon Jones Other - Murie Bldg. & IMG_4197.JPG Irving I Bldg. - RTC photo documentation No No Jon Jones Other - Murie Bldg. & IMG_4198.JPG Irving I Bldg. - RTC photo documentation No No Jon Jones Other - Murie Bldg. & IMG_4199.JPG Irving I Bldg. - RTC photo documentation No No Jon Jones Other - Murie Bldg. & IMG_4200.JPG Irving I Bldg. - RTC photo documentation No No Jon Jones Other - Murie Bldg. & IMG_4213.JPG Irving I Bldg. - RTC photo documentation No No Jon Jones Other - Murie Bldg. & IMG_4221.JPG Irving I Bldg. - RTC photo documentation No No Jon Jones Other - Murie Bldg. & IMG_4223.JPG Irving I Bldg. - RTC photo documentation No No Jon Jones 84 of 85 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 UNIVERSITY OF ALASKA FAIRBANKS Inspection Date(s): 09/13/2021 - 09/15/2021 Other - O'Neill Bldg. - IMG_4225.JPG RTC photo documentation No No Jon Jones Other - O'Neill Bldg. - UAF O'Neill Resources Building.pdf No No Jon Jones Response email to AOC's Other - Reichardt UAF Reichardt Building - EMAIL.pdf No No Jon Jones Bldg. - Response email to AOC's Other - Reichardt Reichardt Bldg Waste Inventory No No Jon Jones Bldg. - Waste Final.xlsx inventory Other - Reichardt Bldg. - RTC photo documentation IMG_4156.JPG No No Jon Jones Other - Reichardt Bldg. - RTC photo documentation IMG_4161.JPG No No Jon Jones Other - Reichardt Bldg. - RTC photo documentation IMG_4163.JPG No No Jon Jones Other - Reichardt Bldg. - RTC photo documentation IMG_4166.JPG No No Jon Jones Other - Reichardt Bldg. - RTC photo documentation IMG_4169.JPG No No Jon Jones Other - Reichardt Bldg. - RTC photo documentation IMG_4171.JPG No No Jon Jones Other - Reichardt Bldg. - RTC photo documentation IMG_4173.JPG No No Jon Jones Other - Reichardt Bldg. - RTC photo documentation IMG_4177.JPG No No Jon Jones Other - Reichardt Bldg. - RTC photo documentation IMG_4181.JPG No No Jon Jones Inspection Reports Field_Notes_AKD048679567v1.0.pdf No No Jon Jones 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 11/10/2021 85 of 85