Document pe5yR3y1Ywk8pRrZRvdMJ7Yzk
!
O
.K
h
DuPont Modeling Methodology and Results
DRAFT
Shimizu Site June 2003
CAB000375 EID719411
06/02/03
cs
! !
About the Model
Industrial Source Complex Short Term 3 (ISCST3) Sold/used globally, including in Japan
http://www.phoenix-r.co.jp/products/products.htm
Input
Stack height, diameter Flowrate, temperature Mass of pollutant (kilogram per hour) Local meteorological data (Shizouka 1997, 98, 99)
Output
Ambient air concentrations in ug/m3 Max values and locations outside the property line
000042
Prevailing wind Facility
Vapor reaches
Ambient annual ground level
concentration in ug/m3
Model Calculations
Ambient air concentrations based on Gaussian Equation Concentration a function of a vertical term and a dispersion term Vertical term based on stack height, receptor elevation, plume rise, mixing Dispersion parameters describe distribution of pollutant in lateral and vertical
WO 000
'
in
MH on ;
Mg I
sg !
o Ul WJ
<0
N
1-- _ \ ;
Shimizu Site
All sources in this area
J CM I -
SMIMCU WOWS % H U P1 0 T P W * C E G CALCULATE j ou our-M ireu n u o m o c x h c a i* co i t o
*' 0 M2J 1M M
Shimizu Modeling Inputs Stack Parameters
Source ID 1 2 3 4
D e s c rip to n Pre-scrubber exit for fine powder scrubber (called "AC Scrubber" on m ap) Post-scrubbBr exit for fine powder scrubber (called "AC Scrubber" on m ap)
DBC Scrubber
M P -2 scrubber
Location
D Plant
D Plant
E Plant: copolymer plant for P FA arid FEP
M P -2 building: copolym er type micro
powder
Operations Operates 24 hours per day, 180 days
per year Operates 24 hours per day, 180 days
per year Operates 24 hours per day, 270 days
per year Operates 24 hours per day, 200 days
per year
Height, m 8 15
18.2
161
VV
Diam eter, m 0 .6 8 (,)
0.6
0.6
10.6 assum ed
r-
Flowrate m 3/hr
Temp
2400
100 C
9600
40-50 C
1620
40 C
7500
40 C assumed
(1 ) G iven in em ail o f 4 /1 7 /0 3 from H id e laka Hirom alsu: 6 0 0 sq m m sq uare diam elfar. C onverted to effective d ia m e te r o f 0 .6 8 m eters.
vOOOO
Correct stack height?
Shimizu Modeling Inputs Emissions Rates
Source ID
Description
Pre-scrubber exit for line powder scrubber (called "AC Scrubber" 1 on map)
Location D Plant
Emission Rate, Emission kg/hr Rate, g/s
0.24 0.0667
Post-scrubber exit for fine powder scrubber (called "AC 2 Scrubber" on map)
D Plant
0.24
3 DBC Scrubber
E Plant: copolymer plant for
PFA and FEP
0.07
0.0667 0.0194
4 MP-2 scrubber
MP-2 building: copolymer type micro-powder
0.125
0.0347
Preliminary Modeling Results
Maximum annual concentrations calculated as 14 ug/m3 Point of maximum concentration at south boundary of site (on property line)
CO
CONTOUR RESULTS FROM MODEL
CAB000383 EID719419
OOQOo
i
?
w
Contribution of Sources
Source ID 1
2
QO
4
Description Pre-scrubber exit for fine powder scrubber (called "AC Scrubber'1on map) Post-scrubber exit for fine powder scrubber (called "AC Scrubber'1on map)
Location
Contribution,
Height, m
u g /m 3
Contribution, %
D Plant
8
7.002
50
D Plant
15
3.345
24
DBC Scrubber MP-2 scrubber
E Plant: copolymer plant for PFA and FEP
MP-2 building: copolymer type micro-
18.2 16.1
2.953
0.771 total = 14.071
21 5