Document pe3eREdRpdnNed6n2gg2Q3Yqj
Heating
Velocity (continued) return grilles, 289 unit heater, 229
Vena contracts, 45 Venetian blinds, 135
Ventilation, 6, 63, 149, 178, 186, 206, 683, 686
animal shelters, 167, 158 attic. 131, 146 crawl spaces, 146 dairy stables, 167 parages, bring space, 146, 186 natural, 153
general rules, 156 outdoor air, 63, 186, 206, 682, 683 passenger bus m summer, 683 railway p&senger car, 681 rules, 166 ship, 686 r
walls, 147 wind forces, 149
Ventilator* ventilators, 155 control, 156 roof, 155 unit, control, 225
Vertical blow unit heater, 228
Vertical openings, 153, 155 sealing of, 153
Vibration, machine, 363 Viscous filters, 334
impingement,' 334 Vitiation of air, 63 Volume
control, 288 furnace, 499, 502 specific, 6
W
Wall, walls heat flow through, 112-119, 188, 205 heat'transfer coefficients, 49, 112-U9 infiltration through, 149 time lag of solar radiation, 201
Warm air gravity heating system, 6, 268 mechanical {forced) systems, 247 air distribution, 247 automatic control, 267, 643 ceiling panel system, 267 cooling methods, 669 continuous circulation, 267 dampers, 249
Ventilating Air Conditioning
Warm air (continued) design procedure, 250, 260 ducts, 249 fans, 524 filters, 524 furnace, 524 heavy duty, 524 selection, 264 humidification, 526 large systems, 260
perimeter system, 250-260 panel heating, 267 registers and grilles, 247
Washer, washers, 610 air, 1, 610-612 : cooling, 612
dehumidification, 612 humidification, 612
Water analysis, 752 atmospheric cooling equipment, 597-599 characteristics, 751 clarification, 751 coils, 324, 782 content of radiators, 416 control of temperature service, 783 cooled condenser, 574 cooling tower, 599 corrosion treatment, 753-761 demand, 766, 772-777 faucets, 765 fittings, los, 770, 771 fixtures, 766 fixture units, 766 formed deposits, 751 heater coal-fired, 777 electric, 779 indirect, 780 solar, 784 heating. 773, 777 in building material, 138 load, 765 make-up, 606, 756 maximum main temperature, 613 meters, 770 mineralised, 752 properties of, 22, 752 services, 765 storage capacity, 773 supply piping, 782 arrangement, 782 temperature control, 783 thermodynamic properties of, 22 treating chemicals, 751, 762 well temperatures, 614
Water vapor, 13, 18-21* 137 condensation in buildings, 137 saturation pressure, 13, 22
Guide
I960
Water vapor (continued) specific enthalpy, 2 specific volume, 6; 22 surface condensation, 142
Weather eondituu design outdoor, 161, 178
Welding, 455
Wet-bulb temperstore. (see Tempera ture), 5, 15, 605
Wet cup, 140 Wet return, 5, 367
Wind, winds forces, 149, 153 due to stack effect, 149
- natural draft equipment, 531 selection of, velocity, 162, 180
Window, windows coefficients, of transmission, 133 leakage,-150 solar radiation through, 194
Winter air conditioning system, 2, 669 comfort chart, 69, 72 freezing equipment, f7
Wound rotor motor, 659 Wrought-iron pipe, 447` Wrought-eteel pipe, 447
Y
Year-aroond air-conditioning system, 269, 669
air flow in, 271, 672 control methods, 270, 637-641, 643 design procedure, 269, 275, 669 equipment arrangement, 276 installation, 269, 669 location of apparatus, 276, 671 residential, 669 < selection, 275, 669
Z
Zero, absolute, 1
cones control, 270, 636, 641, 642 evaporative regulation, 65 metabolic regulation, 65 thermal neutrality, 69 vaso-motor regulation, 65
Zoning, 270, 636, 641 control, 270, 636, 641 hot water system, 641 reheat, 270 volume control, 270
CHAPTER 1
TERMINOLOGY
Glossary of Physical and Heating, Ventilating, Refrigerating and Air Conditioning Terms Used in the Text
Absolute Zero: The sera from which absolute temperature is reckoned. Approximately --273.15 C or --459.67 F. These values were established by the Tenth General Conference on Weights and Measures (1954).
Absorbent: A sorbent which changes physically or chemi cally, or both, during the sorption process.
Absorption: The action of a material in extracting one or more substances present in an atmosphere or mixture of gases or liquids; accompanied by physical change, chemical change, or both, of the sorbent.
Acceleration: The time rate of change of velocity, i.e., the derivative of velocity with respect to tune. In the cgs system the unit of acceleration is the centimeter per (second) (second); in the fps system the unit is the foot per (second) (second),
Acceleration Due to Gravity: The rate of gun in velocity of a freely falling body the value of which varies with latitude and elevation. The international gravity standard has the value of 980.665 cm per (sec) (sec) or 32.174 ft per (sec) (sec) which is the actual value of this acceleration at sea level and about 45 deg latitude.
Adiabatic: An adjective descriptive of a process such that no heat is added to, or taken from, a substance or system under going the process.
Adsorbent: A sorbent which does not change physically or ' chemically during the sorption process.
Adsorption: The action, associated with surface adherence, of a material in extracting oue or more substances present in an atmosphere or mixture of gases and liquids, unaccompanied by physical or chemical change. Commercial adsorbent ma terials have enormous internal surfaces.
Aerosol: An assemblage of small particles, solid or liquid, suspended in air. The diameters of the particles may vary from 100 microns down to 0.01 micron or less, e.g., dust, fog, smoke.
Air Cleaner: A device designed for the purpose of removing airborne impurities such as dusts, gases, vapors, fumes, ana smokes. (Air cleaners include air washers, air filters, electro static precipitators, and charcoal filters.)
Air Conditioning: The process of treating air so as to con trol simultaneously its temperature, humidity, cleanliness, and distribution to meet the requirements of the conditioned space.
Air, Dry: In psychrometry, air unmixed with, or containing no, water vapor.
Air, Saturated: Ajnixture of dry air and saturated water vapor, all at the*same dry-bulb temperature.
' Air, Standard: Air with a density of 0.075 lb per cu ft and an absolute viscosity of 0.0379 X 10~* lb mass per (ft) (sec). This is substantially equivalent to dry air at 70 F and 29,92 in. Hg barometric pressure.
Air Washer: An enclosure in which air is drawD or forced . through a spray of water in order to cleanse, humidify, or de-
humiaify the air.
Anemometer: An instrument for measuring the velocity of a fluid- -
Aspect Ratio: In air distribution outlets, the ratio of the lengtn of the core of a grille, face, or register to the width.
In rectangular ducts, the ratio of the width to the depth.
Atmospheric Pressure: The pressure of the atmosphere to
be measured by means of the barometer. Standard Atmospheric Pressure or Standard Atmosphere is exactly 1,013.250 dynes per sq cm by recent action of the Tenth General Conference on Weights and Measures (1954). H is approximately the pres sure exerted by a column of mercury 76 cm high at standard gravitational acceleration, 980.665 cm per (sec) (sec), the mercury having a density of 13.5951 g per cu cm. It is equiva lent to 14.696 psi or 29.921 in. Hg at 32 F.
Baffle: A surface used for deflecting fluids, usually in the form of a plate or wall.
Blast Heater: A set of heat transfer coils or sections used to heat air which is drawn or forced through it by a fan.
Blow (throw): In air distribution, the distance an air Btre&m
travels from an outlet to a position at which air motion along
the axis reduces to a velocity of 50 fpm. For unit heaters, the distance an air stream travels from a
heater without a perceptible rise due to temperature difference and loos of velocity.
Boiler Heating Surface: All of the surface of the beat-trans
fer apparatus in contact on one tide with the water or wet steam being heated and on the other side with the gas or re
fractory being cooled, in which the fluid being heated forms
part of the circulating system, this surface to be measured on the side receiving heat. (Stationary Steam-Generating Units, ASMS Power Test Codes, PTC 4-1946.)
Direct Heating Surface is generally understood to be the
boiler heating surface subject to direct radiation from the sur
face of the pate, or from the surfaces of oil or gas burners.
Indirect Heating Surface is the boiler heating surface within
the flues.
Boiler Horsepower: The equivalent evaporation of 34.5 lb of water per hr from and at 212 F. This is equal to a heat out put of 970.3 X 34.5 = 33,475 Btuh.
British Thermal Unit (Btu): The Btu is defined as 778.177
foot-pounds if it is related to the IT calorie in such a way that
1 IT calorie per (kg) (C deg) 1 Btu per (lb) (F deg), with lib s 453.5924 g. The Ninth General Conference on Weights
and Measures (1948) recommended the absolute joule as the
fundamental unit of energy thereby, in effect, liquidating the old international electrical units. This calls for a redefinition of the International Tables calorie (IT cal) according to the
following conversion factor: 4.18684 joule per IT calorie.
Calorie (Gram Calorie): The IT gram calorie is equivalent to 0.003968 Btu. (See definition of Btu.)
Central Fan System: A mechanical indirect system of heat
ing, ventilating, or air conditioning, in which the air is treated
or handled by equipment located outride the rooms served,
usually at a central location, and is conveyed to and from the
rooms by means of a fan and a system of distributing ducts.
(See Chapter 19.)
y'
Chimney Effect: The tendency of air or gas in a duct or
other vertical passage to rise when heated due to its lower density compared with that of the surrounding air or gas. In buildings, the tendency toward displacement (caused by the difference in temperature) of internal heated air by un seated outside air due to the difference in density of outside
and inside air.
Coefficient of Performance (Heating): The ratio of the total
instantaneous useful heating effect produced by a heat pump
system at stated conditions, to the heat equivalent of the total energy input rate required to drive or operate the system.
Coefficient of Performance (Cooling): The ratio of the instantaneous refrigeration effect produced by a heat pump