Document pdrn7nk5dQ49gxKbzbZzoa8k

TIER I WASTE HANDLING SUMMARY DOCUMENT PLANT: Anniston Plant WASTE REF. NO. & NAME: SCO08 - Still Bottoms/Tar 1. Description of Waste Source: The production of polyphenyls involves several separate distillation steps. The bottoms from these distillation steps is the source of this waste stream. 2. Description of Waste: The still bottoms are a high melting point tar residue consisting primarily of quarterphenyl isomers and higher polvphenyl isomers. 3. Current Waste Handling and Land Disposal Practice: The molten material is currently pumped into open pits in the ground where it is allowed to harden by cooling. When the open pits are full, about every 18 to 24 months, the solidified material is excavated by earth moving equipment and hauled by dump truck to on-site non-hazardous waste landfill. 4. Annual Disposal Quantity: The quantity disposed of in 1987 was estimated at 1,600,000 pounds. 5. Unit Disposal Cost: $0.010/lb. Annual Disposal Cost: $16,000/vear 6. Summary of Available Analysis/Contamination Data: This material is primarily aromatic hydrocarbon with very low levels of hydrogen and essentially no contaminants (ie: nitrogen, sulfur, etc.). A sample taken on 2/17/87 was analyzed for volatile compounds, acid and base neutral compounds and TCLP pesticide, herbicide and metals. Attached herewith is a copy of the analytical results. 7. Description of Alternative Disposal Methods With Cost: There are several alternative disposal methods available for this material. Hazardous waste landfilling would cost approximately $150,000/year; hazardous waste incineration would be possible at a cost that would very likely reach $ 1-3M per year. Neither of the options would necessarily stop the use of on-site open pit cooling. DEFENDANT'S EXHIBIT?., z ( - fl QS* Q90928 WATER PCB-SD0000051873 TIER I WASTE HANDLING SUMMARY DOCUMENT (continued) 7. (Continued) Three engineering studies are currently underway; one is to sell the still bottoms as a product thereby effectively eliminating it as a waste; and the second study is investigating the use of the still bottoms as an alternate boiler fuel in the plant's package steam boiler. This alternate fuel use route is estimated to cost $250,000 capital. Other studies are being initiated to investigate the use of santotar as a raw material for the production of carbon fibers or carbon electrodes. 8. Discussion of Potential Environmental Impact and Potential Future Economic Liability for Current Disposal Practice and Alternative Disposal Methods; Hazardous waste land disposal and hazardous waste incineration are each more protective of groundwater than the present non-hazardous landfill disposal. Upgrading to co-product status may be more protective although environmental fate studies of the use as an asphalt sealer would have to verify. Additionally, other toxicological studies might have to be performed prior to commercialization. Use of material as an alternative boiler fuel would effectively destroy greater than 99% of the material while providing an economic benefit. The products of combustion would be no worse than current fossil fuels and probably better thereby yielding an overall positive environmental impact. 9. Recommendation: Continue investigation toward completion of upgrade to alternate boiler fuel and/or other suitable alternative use that are now being studied. The goal is to stop landfilling by year-end 1989 and move to the most suitable alternative use. OSW 090929 WATER PCB-SD0000051874 TIER I WASTE HANDLING SUMMARY DOCUMENT (continued) 1G. Reviews: a) Prepared by: b) Plant Mgr. Review: c) Final Rec. Review By Op. Co. Env. Mgr. : d) Final Rec. Review By Op. Co. DEO: e) Final Rec. Review By Op. Co. Dir. of Mfg.: D. RLC6/sag DSM 090930 WATER PCB-SD0000051875 TIER I WASTE HANDLING SUMMARY DOCUMENT PLANT: Anniston Plant WASTE REF. NO. & NAME: SCO09 - Polyphenyls Piping and Carbon from Decoking 1. Description of Waste Source: Within the polyphenyls production department, various items of a general trash type are generated which are contaminated or potentially contaminated with non-hazardous process chemicals. 2. Description of Waste: Waste types included contaminated gravel, dirt, rags, gloves, sample containers, filter papers, empty biphenyl bags, absorbent pads, etc. contaminated with process materials (polyphenyls). 3. Current Waste Handling and Land Disposal Practice: Materials are swept up and/or hand carried and placed into dumpster containers for disposal in an on-site non-hazardous landfill. 4. Annual Disposal Quantity: It is estimated that the 1987 disposal quantity was 41,500 pounds. 5. Unit Disposal Cost: $0.065/lb. (1987) Annual Disposal Cost: $2,700/year (1987) 6. Summary of Available Analysis/Contamination Data: No analytical determinations have been performed on this general trash. Contaminants include: biphenyl, santowax, therminol and HB-40. 7. Description of Alternative Disposal Methods With Cost: Landfill disposal in a hazardous waste landfill would cost approximately $15,000/year and is essentially the only alternate in that the on-site landfill operation is being terminated and no other option exists. SW 0*0934 WATER_PCB-SD0000051876 TIER I WASTE HANDLING SUMMARY DOCUMENT (continued) 8. Discussion of Potential Environmental Impact and Potential Future Economic Liability for Current Disposal Practice and Alternative Disposal Methods: Disposal in a hazardous waste landfill which meets the minimum technological requirements would be more protective of groundwater than the current on-site landfill disposal option. Additionally, on-site landfill capacity and capability has about ended. 9. Recommendation: Continue with recently instituted off-site hazardous waste landfill disposal while investigating ways of reducing and/or eliminating generation through tighter management controls. 10. Reviews: a) Prepared by: Typed Name R.L. Cheever Signature, Date 11/16/88 b) Plant Mgr. Review: D.K. Denner c) Final Rec. Review By Op. Co. Env. Mgr. : d) Final Rec. Review By Op. Co. DEO: e) Final Rec. Review By Op. Co. Dir. of Mfg.: RLC6/sag DSW 0909.32 WATER_PCB-SD0000051877