February 23, 1971
Mr. Richard Pfieffer Union Carbide
P.0. Box 180 Slstersvllle, Vest Virginia
26125
Pear Mr. Pfieffer:
In substituting Thertninol FR-0 for the non-avallable Aroclor
1232 in your heat transfer application you are maintaining
the vory desirable features of stability at relatively high temperatures and fire resistance but must still review the environmental contamination considerations.
To keep stability and fire resistance in Thertninol fr-o vte use some of the more resistant polychlorinated biphenyls (PCB) which have been identified as environmental contaminants. Ke believe, howover, that the advantages gained warrant the extra
care involved In its use.
To prevent the escape of PCB.'s to the environment calls for a lovel of control and housekeeping many of us have never been asked to achieve in the past. Every effort must be made to
prevent leakage and spillage. Maintenance must be kept at a very high standard. For those areas where leakage and spills will occasionally occur, catch pans must be provided. These pans must drain to a collecting basin or be emptied by respon
sible employees on a scheduled basis.
Mixing of Aroclors with waste water streams should be avoided
since separation of FCB's from water can be costly. If mixing cannot be avoided, a catch basin and settling pond should be
provided to separate the heavy Aroclor from the water.
Unusable contaminated Aroclor should be disposed by incinera
tion which assures complete destruction to COg, HpO, and HC1. Any incineration below 800*C will result in vaporization which will contaminate the atmosphere or in partial oxidation which may yiold materials which are highly toxic. To avoid polluting the atmosphere with HC1 the stack geses must be scrubbed and neutralized before disposal into the plant waste water syGtem.
DSW 019567
-1
STLCOPCB4007500
-2-
' Vi
To help our customers with their liquid disposal problems, v.c havo offered to accept Tor future incineration scrap liquid Aroclora chipped to MonEanto Company, V. Q, Krur.rrieh Plant, Sauget, Illinois, Attention: Supervisor, Dept. 246. The charge for this disposal is 3^ per pound of r.aterlol, Tliio charge is tentative pending a complete evaluation of incineration cest3 and does not includes freight or container coots. The cervices of a waste disposal company such uo Rollins-Furle Inc., 3200 Concord Pike, V/ilnington, Delav/are, 19003# (302) 478-5150 should also be investigated.
Contamination of the atmosphere must also bo eliminated. All handling systems must be elosed wherever possible. Fumes exhausted from a tank, vessel, or working area must be trap ped and collected udng condensers and entrainment separators.
Solids contaminated with PCB's pose a greater challenge. Until a proper incinerator is designed, we are suggesting that disposal be made in an authorized, properly operated land fill away from any water systems. These solldB include absorbing materials used to contain spills, rags and containers.
In summery, control of PCB's can be achieved with equipment engineered to prevent looses and maintained properly coupled with good manufacturing practices which result In a high stan dard of housekeeping.
From the Interest and concern which you have expressed, I an certain that you will do all you can to reduce the escape of PCB's from your operation. When all of us succeed in this ob jective, I am confident that no regulatory agency will be com pelled to take precipitous action regarding the use of PCB's in vital applications.
Sincerely,
V/. B. Papageorge Manager Environmental Control