Document pZQqMeznZJYVRwdGEO3z8Rww

AR106-0370 Centre Analytical Laboratories, Inc. 3048 Research Drive Phone: (814) 231-8032 State College, PA 16801 Fax: (814) 231-1253 or (814) 231-1580 Analytical Report Fluorochemical Characterization of Drinking Water Samples Cleveland, Tennessee (W1973) Centre Analytical Laboratory Report No. 023-007A Testing Laboratory Centre Analytical Laboratory, Inc. 3048 Research Drive State College, PA 16801 3M Environmental Laboratory Contact Kent R. Lindstrom Bldg. 2-3E-09 P.O. Box 33331 St. Paul, MN 55133-3331 Phone: (651)778-5352 Requester Kris J. Hansen, Ph.D. 3M Environmental Technology & Safety Services Bldg. 2-3E-09 P.O. Box 33331 St. Paul, MN 55133-3331 C00354 PAGE 1 0 F 5 1 Introduction Results are reported for the analysis of a series of drinking water samples received by Centre Analytical Laboratories, Inc. (Centre) from the 3M Environmental Laboratory. The samples were collected from Cleveland, Tennessee. The Centre study number assigned to the project is 023007. Specific fiuorochemical characterization by liquid chromatography / tandem mass spectrometry (LC/MS/MS) was requested for all samples. A total of 17 samples were received for analysis. The samples were prepared and analyzed by LC/MS/MS for the following list of fluorochemicals: Table 1: Target Analysis Compound Name Perfluorooctane Sulfonate Perfiuorooctane Sulfonvlamide Perfluorooctanoate Acronvm PFOS PFOSA POAA Data generated in support of this study was generated according to USEPA Good Laboratory Practices (GLPs). The analytical method used was validated by Centre. The validation protocol and results are on file with Centre. Data presented here is the highest quality data available at this time. 2 Sample Receipt The samples were submitted in individual plastic containers and were not preserved. Seventeen individual sample containers were received. Samples were received on 02/15/00. The sample collection dates were not supplied. Chain-of-custody information is presented in Attachment A. Samples MC-127H and MC-134H were not analyzed as per client request. (Telephone call to Kris Hansen on 2/16/00). 3 Holding Times The analytical method used was validated against a maximum holding time o f 14 days. The stability of the analytes of interest for longer periods has not been determined. PAGE 2 OF5 C00355 4 Methods - Analytical and Preparatory 4.1 LC/MS/MS 4.1.1 Sample Preparation for LC/MS/MS Analysis Samples were initially treated with 200 uL of 250 mg/L sodium thiosulfate solution to remove residual chlorine. Solid phase extraction (SPE) was used to prepare the samples for LC/MS/MS analysis. A forty-milliliter portion of sample was transferred to a C18 SPE cartridge. The cartridge was first eluted with 5 mL of 40% methanol in water solution. The eluate was discarded and the SPE column was then eluted with 100% methanol. A 5 ml portion of methanol was collected for analysis by LC/MS/MS. This treatment resulted in an eight-fold concentration of the samples prior to analysis. 4.1.2 Sample Analysis by LC/MS/MS In HPLC, an aliquot of extract is injected and passed through a liquid-phase chromatographic column. Based on the affinity of the analyte for the stationary phase in the column relative to the liquid mobile phase, the analyte is retained for a characteristic amount of time. Following HPLC separation, ES/MS provides a rapid and accurate means for analyzing a wide range of organic compounds, including fluorochemicals. Electrospray is generally operated at relatively mild temperatures; molecules are ionized, fragmented, and detected. Ions characteristic of known fluorochemicals are observed and quantitated against standards. A Hewlett-Packard HP1100 HPLC system coupled to a Micromass Ultima MS/MS was used to analyze the sample extracts. Analysis was performed using selected reaction monitoring (SRM). Samples were extracted on 2/17/00 and analyzed by MS/MS between 2/17/00 and 2/18/00. The HPLC and MS/MS methods used for analysis and instrument parameters can be found in attachment D. 5 Analysis 5.1 Calibration A 7-point calibration curve was analyzed at the beginning and end of the analytical sequence for the compounds of interest. The calibration points were prepared at 0, 25, 50, 100, 250, 500, and 1000 ng/L (ppt) The response of the quantitation ion versus the concentration was plotted for each point. Using linear regression with 1/x weighting, the slope, y-intercept and correlation coefficient (r) and coefficient of determination (r2) were determined. A calibration curve is acceptable if r >0.985 (r2 > 0.970). Calibration standards are prepared using the same SPE procedure used for samples. Calibration check standards were analyzed periodically (every three to five sample injections) throughout the analysis sequence. Compliance is obtained if the standard analyte concentrations are within +/-20% of the actual value. For the results reported here, calibration criteria were met. PAGG 3 O r 5 CC0356 5.2 Blanks Extraction blanks were prepared and analyzed with every extraction batch of samples. The extraction blanks should not have any target analytes present at or above the concentration of the low-level calibration standard. For these samples, the extraction blanks were compliant. Instrument blanks in the form of clean methanol solvent were also analyzed after every highlevel calibration standard, and after known high-level samples. Again, the blanks should not have any target analytes present at or above the low-level calibration standard. For the samples presented here the instrument blanks are compliant. 5.3 Surrogates Surrogate spikes are not a component of the LC/MS/MS analytical method. 5.4 Matrix Spikes Matrix spikes were prepared for every sample at a concentration of 100 ng/L using all compounds of interest Matrix spike recoveries are given in Attachment C. Field spikes were also prepared on several samples at a concentration of 100 ng/L using all compounds of interest. Field spike recoveries are also given in Attachment C. 5.5 Duplicates All samples were analyzed in duplicate. Results are given along with the sample results in Attachment B. 5.6 Laboratory Control Samples Milliq water was spiked with all compound of interest at 25 and 250 ng/L. Initial analysis of the 25 ng/L LCS showed low recovery for PFOS. The standard was reinjected and was found to have acceptable recovery (70-130%). All other recoveries for all compounds were between 70130% in each LCS. 5.7 Sample Related Comments Field blank samples consisted of empty containers. Forty milliliters o f type I water filtered through a hypercarb cartridge was added to the empty container and analyzed in the same manner as the other samples. 6 Data Summary Please see Attachment B for a detailed listing of the analytical results. 7 Data/Sampie Retention Samples are disposed of one month after the report is issued unless otherwise specified. All electronic data is archived on retrievable media and hard copy reports are stored in data folders maintained by Centre. PAGE4 OFS 0003 8 Attachments 8.1 Attachment A: Chain-of-Custody 8.2 Attachment B: Results. 8.3 Attachment C: Matrix Spike Recoveries (Field and Laboratory Spikes) 8.4 Attachment D: LC/MS/MSRaw Analytical Data 9 Signatures Other Lab Members Contributing to Data Enaksha Wickremesinhe Karen Smith PAGES OFS C0035S I I 1 I B B B B B I B B B B B B B B Report Results to: VOCs None Other Total Number of Containers 3IV3 Knvil .mental Laboratory Form 30/7 - PWO Shipping Adilrti: 29SJMii>PBOalduugl$.lM2ANJvEe5n05u19e0 ATSFAaeltmlXeer:ppn(hla6eot5eRn1:ee)(:c76e75i8v1-)i6n71g77:66-(667515)3778-4946 Chain of Custody /Reque. j r Laboratory Analytical 1/121 Project ID/Project N am e ( ^ j - g T I f f u H Y j - k r T a a * / t t / i c l Tem plate # ( ^inai Report Due D a tif bK Project Lead r l s jA /J /o < V n Internal Due Date Dept. # (main) | Ciass/Job/Project # Q ) | y^ d )| 3MFoEr nInvteii.dliUPseroOjenclyt # Contact Name Company Mailing Address - 2 -O i VO6 t V , / Date Available Date Due City, State. Zip ,ft, / ) -S S i Telephone Contract Lab ________________________ F A X # & S T / ! 7 7 8 > - ? H (t?_____________________ Special instructions and/or Specific Regulatory Requirements: (iiicUiod, limit of dcteOiun. repotting wilts, etc.) G /0-ofr Preservatives: c V? .. T a * c . Analysis Requested: Complete below. Attach any associated Information. u > iV $ CisvelA'iA/TsJ n o z X <e oCA M X Item # Client Sample Identification 1. m / - Sib \ D lp~P 2. - S i k 1 - q ^ l A - S p i l u - P | / U 3. 4. y W _ H 3 i 1-1 00 ^ 5. m c - l 3 ^ p - S i b S - P / A ^ 6. tyniphj7. - f / . l / . iS U n K -T p -fx -l P F t S 8. --9. ./ -- -- --* -* . .... 10. Collected by (print): i MT3 o-4-4 Item # t Relinquished by/Affiliation 3in oco i~ ~ ? *-- iltu ^ S^mu.rtTiLrj '^F `is o 3M Date Time Matrix/ UM S# Sampled Sampled Media Enter Ita number of containers of each IAJ*tflb A)\fc AJ\k. I t l t b / ___ 7 / /_ 7 r \ _L_ i A, \ u 1|* L . __ i k HITr)"1 i-- L\ ___ _ -- ----------- -- & I / /--V / A, i _ J ___ Collector's signature: (Enter an 'X* in the box botow to indicate reouesO Sample Condition Upon Receipt: Acceptable O Other. Temperature: c Received on Ice OinurAisuctetedCoCs: \-7 Q O ( H | J 2 , 1 1 1 ^ 3 , n *>o, n i3 i, n iy > , n i5 ^ ___ Copies lo; -+ i'uju oi ) '12 Commente: 3048 Research Drive, State College PA 16801 814-231-8032 FAX 814-231-1253 I I I 1 R I 1 1 R Analytical Results W1973 Cleveland, Tennesse 3M Sample Identification MC-115H MC-117H MC-120H MC-121H MC-123H MC-126H MC-128H MC-131H NA MC-132H NA MC-133H Sample Description Intake-P/N Intake-P/N duplicate Intake-Field Blank Outflow-P/N Outflow-P/N duplicate Site 1 P/N Site 1 P/N duplicate Site 2 P/N Site 2 P/N duplicate Site 3 P/N Site 3 P/N duplicate Field Blank P/N Empty PFOS (ng/L) <25 <25 <25 <25 <25 <25 <25 <25 <25 <25 <25 <25 PFOSA (ng/L) <25 <25 <25 <25 <25 <25 <25 <25 <25 <25 <25 <25 POAA (ng/L) <25 <25 <25 <25 <25 <25 <25 <25 <25 <25 <25 <25 I R R I R R R B C0C3G1 Please refer to the reverse side for our standard terms and conditions.