Document pYEykq22DVv0k8Rob20DYbrw
AMERICAN-STANDARD
type C boiler stoker fired
If any heating boiler has ever earned and won the right to become known as "the standard of the Industry," the now familiar and popular Kewanee Type "C" Boiler, first introduced into the market in 1928, has been accorded this recognition by engineers everywhere. Unmatched for its dependability and efficient service, these compact boilers provide reliable heating for many years with minimum service or attention. Simplified three-pass design extracts maximum heat from the gases... assures highest operating efficiency ... low stack temperatures. Large firebox with self-cleaning, arched, upright crown sheet allows thorough mixing of fuel and air . . . complete combustion before hot gases enter the fire tubes. Second pass is rear to front through direct fire tubes ... the third from front to rear in return tubes. There are no refractory baffles to burn out causing the short circuiting of gases... water content is ample ... and steam space is proportioned for plenty of dry steam. That's why over-all efficiencies of 80% and more are not uncommon with the Kewanee Type "C," and are maintained continuously in actual practice.
AMERICAN STANDARD
... a standard . . . first choice of experie
type C boiler oil or gas fired
type C boiler with front head opening
Copy1 'Kdl 1963 by American Radiatoi and Standard Sanitary Corporation
Low-Set Design is VERSATILE
Where minimum head room is an important factor, the Kewanee Low-Set Type "C" Boiler is the ideal answer. The same dependable features that are characteristic of the standard Type "C" Series are incorporated into this compact, low design, further extending the versatility of this popular boiler model. An opening in the front head, as illustrated at the left, is provided to accommodate a burner and secondary windbox of your choice. This feature together with the Type "C'"s generous firebox eliminates the necessity of high settings. . . provides proper combustion volume to completely burn all grades of oil and gas.
The Type "C" 7L200 Series is constructed in accordance with the ASME Low Pressure Boiler Code. Twelve sizes range in gross outputs from 2,160,000 to 14,400,000 Btuh or 64 to 430 hp.
28783
SUPPLY OPENING150 LB. AM. STD. FLANGE
DD-
D+-
Y -B-
K rbl-- --
SAFETY VALVE
LIFTING
OPENINGS
LOOP /, A,
EE
Zt f-2'
n.
11" x 15" MANHOLE ON 7L282 AND LARGER
SMOKE OUTLET
" SURFACE BLOWOFF RIGHT SIDE ONLY
- WATER COLUMN CONNECTIONEACH SIDE
:of
O
WASHOUTEACH SIDE
P
M-
cjcT
-BB-
'WASHOUTEACH SIDE
ratings--mechanically f | rsgt
BOILER NUMBER
7L280
SBI gross output--steam
--water -- Steam per hour--212F
sq. ft. 9000 sq-ft- 14400 MBh. 2160
lb. 2208
SBI net rating--steam --water
-- Certified output--
-- Firing rate--150,000 Btu oil
--gas
sq. ft. \Mq-Bfht-.
hp. MBn.
,?EhMBh.
6760 10820
1620
78 2625
22 3280
Heating surface--waterside --fireside
sq. ft. 429 sq. ft. 397
Furnace volume--SBI minimum cu. ft.
-- net
cu. ft.
52.1 65.7
Water content--steam boiler --water boiler
lb. 3655 lb. 5055
Safety valve cap.
lb. steam per hr. 2625
7L281
10500 16800 2520 2588
7880 12610
1890
92 3060
26 3830
500 463
60.8 75.2
4265 5880
3060
7L282| 12750 !
20400 3060 3140
9580 15330
2300
111 3718
31 4650
i I
j !
i
!
i
1 {
608 j 563 1
701 91.0 | 5130 !
7030 1
3718 |
7L283
15000 24000
3600 3726
11260 18020
2700
131 4374
37 5460
715 662
86.8 104.8
6020 8230
4374
7L284
18750 30000
4500 4623
14060 22500
3370
164 5464
46 6840
893 827
108.5 130.6
7240 9490
5464
- oil, c? fz
7L285
22500 36000
5400 5555
16880 27010
4050
195 6559
54 8200
1072 993
130.2 154.2
8640 11310
6559
7L286
26250 42000
6300 6486
19690 31500
4720
228 7650
64 9560
1250 1157
151.8 189.3
9155 12480
7650
7L287
30000 48000
7200 7418
22510 36020
5400
261 8745
73 10920
1429 1323
173.5 214.4
10835 14610
8745
f f q |r f;- .
7L288
37500 60000
9000 9281
28130 45010
6750
326 10929
91 13670
1786 1654
216 9 256.1
12730 17145
10929
7L289
45000 72000 10800 11109
33750 54000
8100
392 13114
110 16400
2143 1985
260.3 303.4
15470 20735
13114
7L290
52500 84000 12600 12972
39370 62990
9460
456 15300
127 19120
2500 2315
303.6 379.5
17625 23610
15300
7L291
60000 96000 14400 14835
45000 72000 10790
521 17485
146 21900
2857 2645
346.9 429.8
20360 27155
17485
equipment available on
ti a il'Z'Ts
.1. Three-Pass ASME Code Boiler
2 3* Firetubes
3. Steel Bases 14* 7L280 thru 7L283 17' 7L284 thru 7L289 21' 7L290 thru 7L291
4. Rear Smoke Outlet with Cleanout Openings
.5. Gas-Tight Front Flue Door Extension
6 Gasketed and insulated Front Flue Doors
7. Two Firedoors (Stoker Fired Boilers Only) 8. Rear 16" Diameter Access Opening
9. Rear Pyrex Observation Port
.10 Lifting Loops .11 FJue.Cieaner and Handle .12 Washout Plug Socket Wrench
13. Manhole 7L282 thru 7L291
ALL UNITS
1. Additional Base Height 2. Structural Steel Supports 3. Bearing Plate Brackets 4. Top or Side Smoke Outlets 5. insulation Retaining Bars 6. Firedoors for Oil or Gas Fired Boilers 7. Damper Assemblies 6. Special Openings
9. Instantaneous or Tank Type Water Heating Coils 10. Low-Set Application for Natural or Induced Draft 11. 60 PSI Water Working Pressure 12. Insulated Steel Jacket 13. Wing Induced Draft Fan 14. Boiler Feed Units
1. Safety Vaive(s)
2. Steam Gauge with Syphon and Cock
3. Kewanee Water Column
..-4. Water Gauges and Try Cocks C C Wheel Handle Type 7L280 thru 7L285
/:>
Chain Operated type 7L286 thru 7L291
STEAM TRIMMINGS (Not Mounted)
1. No. 58 Reliance High & Low Alarm Water Column 2. M.M. 157 Combination Water Column, Pump Control and Low
Water Cut-Off 3. Chain Operated Water Gauge and Try Cocks
7L280 thru 7L285
1. Relief Valves
WATER TRIMMINGS (Not Mounted)
1. M.M. 51-2 Combination Water Feeder and Low Water Cut-Off 2. M.M. 63 Low Water Cut-Off 3. M.M. 150 Low Water Cut-Off 4. Dial Type Pressure Gauge 5. Dial Type Thermometer
28784
BOILER NUMBER
Shell Diameter--Inside
A--Boiler--width B-- --length
C-- --height D-- --length overall
--Water line height
F--Water column height
G--Steam supply height
H--Smoke outlet height
J--Coil connection height
K--Steam supply
L--Safety valve***
M --Firebox--length N-- --width
P-- --height
R--Surface blow-off
S--Return height
T--Smoke outlet dia.
Y--Smokebox depth--front 2-- --rear
AA--Base--width
BB--
--length
CC--
--height
DD--Tube replacement space--front
EE--
--rear
Steam supply size*
Return size
Outside surface to cover** sq. ft.
Approximate dry weight lbs.
Breeching diameter--one boiler Stack--diameter
--height
ft.
Breeching diameter--two boilers Stack--diameter -- height
ft.
7L280
48"
49* 87 91* 113
77
75
96>/2
75*
80*
36
14
80* 42i/2 34
12
18
24
ii 15
52 90`/2
14
77 73
8
4
145
6600 24 21 50
30 28 60
7L281 7L282
48" 54"
49>/2 100'/2
911/2 126i/2
: 551/2 93`/z
103
1201/2
77 86'/2
75 841/2
96i/2 108
751/2 85
80i/2 90
36 36
18 18
94
421/2 34
87
48/2 37'/2
12 24
18 18
24 28
11 12 15 15
52 58 104 97
14 14
9oy2 86'/2
82/2 79i/2
88
44
162 182
7300 8500
24 28 22 24 60 55
31 34 29 32 70 65
7L283
54"
55`/2 109 103 136
861/2
841/2
108
85
90
36
18
IO2V2 48/2 37`/2
24
18
28
12 15
58 1121/2
14
98 95
8
4
205
9500
28 26 65
36 34 75
7L284 7L285
60" 60"
611/2 109
113'/2 137
; 611/2 1291/2 1131/2 1571/2
971/2 971/2
951/2 951/2
II81/2 1181/2
941/2 941/2
101 101
36 36
14 16
IOI1/2 531/2
43
122
531/2 43
24 24
21 21
30 30
12 12 16 16
64 64 1121/2 133
17 17
98 1181/2 94 114`/2
88
44
227 255
11400 13000
30 31 28 29 65 70
40 41 37 38 75 80
7L286
66"
671/2 128 122 156
104
102
127
101
107
36
16
120 59 4834 24
21
31
12 16
70 1311/2
17
117 113
8
4
275
15800 35 31 65
44 41 75
7L287 7L288 7L289 7L290
66" 78" 78" 84"
671/2 145 122 173
791/2 130 136 164
791/2 154*
142
1881/2
86 1441/2 1611/2 178/2
104 1151/2 1211/2 138*
102 II31/2 1191/2 1361/2
127 142 148 167
101 1131/2 II91/2 136
107 119 125 142
36 36 36 36
16 16 16 16
137i/2 59 48%
122 71 54*
147 71
6 0y2
1361/j 77 66
24 24 24 24
21 23 23 27
31 39 39 43
12 14 14 14 16 20 20 20
70 82 82 148`/2 . 133* 158
88 . 148
17 17 17 21
134 117 1411/2 131'/2 130 111 135* 1251/2
8 10 10 10
4 6* 6* 6*
310 355 405 460
17400 21100 24700 29700
35 39 41 43 33 36 38 40
75 90 80 100
47 50 44 47 85 100
54 56 50 52 90 110
7L291
84"
86 164 1671/2 198
144*
1421/2
173
142
148
36
16
156 77 71%
24
27
43
14 20
88 1671/2
21
151 145
12
6*
490
33800
46 42 100
60 56 110
150 lb. American-Standard flange `'Includes front head and smokebox One or more valves furnished depending on required capacity t Add 3' for top flue gas outlet.
The contractor shall furnish and install............. No. 7L2...... Kewanee Type C Boiler(s) for (oil) (gas) (stoker) firing. Boiler(s) shall contain not less than............. sq. feet of healing surface and have a gross SBI output of............. Btuh and shall be equipped with............... in. high steel base.
NOTE: When Low-Set Type C 7L-200 Series is specifiedr delete above paragraph and insert:
The contractor shall furnish and install............. No. 7L2...... Kewanee Low-Set Type C Boiler(s) for (oil) (gas) firing. Boiler(s) shall contain not less than............. sq. ft. of heating surface and have a gross SBI output of............. Btuh. Boiler(s) shall be equipped with.............. in. high channel base and provided with (circular) (arched) burner opening in front water leg.
Boiler shall have minimum of.............cu. ft. of firebox volume above the bottom of the water leg. Boiler shall have arched crown sheet, shall be of three pass firebox design, and constructed in accordance with the A.S.M.E. code for (15 lb. steam) (30 lb. water). Boiler shall be inspected during con
struction by an authorized inspector and after completion shah be subjected to a 60 lb. hydrostatic test and stamped with all identifying markings and symbols as required by the latest edition of the A.S.M.E. code.
Boiler to be furnished with gas tight front flue doors of size permitting easy access to all tubes and lined with refractory securely keyed in place. Rear smoke box shall have cleanout openings on both sides with smoke outlet at (rear) (top) (r.h. side) (l.h. side) of smokebox. 16" Dia. rear access plate, refractory lined, with observation port in rear water leg.
Boiler trimmings shall consist of the following:
FOR STEAM:
Safety valve(s), steam gauge with siphon and cock, Kewanee water column with hand operated water gauge and try cock assembly--chain operated on 7L-286 and larger.
FOR WATER: Relief valve(s) as required by A.S.M.E. code for low pressure boilers.
NOTE: When a high setting and independent supporting structure is desired, use either of the following options:
Not applicable to Low-Set Boilers.
Structural Steel Supports: Boiler(s) shall be furnished less steel base(s) but with structural steel supports for setting boiler(s) independently of masonry base(s). Distance from boiler room floor to bottom of water leg to be............. ". Structural supports to consist of four H-columns with base plates, one pair each side of boiler and eight pairs of steel brackets securely fastened to the boiler to provide lateral stability according to A.S.M.E. code construction. Each H-column shall be securely bolted to two pairs of boiler brackets.
Bearing Plate Brackets: Boiler(s) shall be furnished less steel bases but with bearing plate brackets for supporting boiler on masonry base(s). Bearing brackets to consist of two pairs of steel bearing plates, each with necessary gussets, welded to the bailer at the bottom of water leg. Each gusset to have a Vi in. hole for wiring insulation to the boiler.
28785
built-in features that make
1. 150 pound American-Standard flange--accepts flanged piping and fittings.
EEWAN'WWe
2. Generous steam space--provides ample storage for dry steam.
l beeitter
J
3. Extensive unbroken steam disengaging area--assures steady water line and prevents priming.
-
4. Water line--well above top row of firetubes.
5. Smoke outlet--rear outlet stand- ---- ard. Jop, right or left hand outlet available as optional equipment.
6. Clean out doors--one on each side of smoke box.
7. Wide water legs--progressively wider at top--permitting free and rapid circulation.
Arched crown sheet--fully effec tive combustion space on fire side-self cleaning and draining on water side.
9. Large furnace volume --Ex
tremely low heat release assures quiet and complete combustion.
10. Kewanee water column--hand
operated gage and try cocks. Chain operated on 7L-286 and larger.
11. Three inch firetubes--rolled and
flared for tight, permanent fit-- No welded tube ends.
12. Insulated flue doors provide ready access to all fire tubes.
13. Large water content--guarantees
adequate reserve for fluctuating loads--steam or hot water.
14. Washout plugs--Hollow brass
with rubber gaskets.
15. Steel base--flanged and rein forced bolted panel construction.
16. Base Flange--with holes on 9"
centers for securing insulation covering.
BOILER SUPPORTING BRACKETS
AHO SUPPORTING COLUMNS
Bearing brackets support the boiler on a masonry base. Structural steel columns furnish support independent of masonry furnace base. Illustrations show methods of application only. Specific details are available from your American-Standard Sales Office.
WATER HEATING COILS
The Kewanee Type C Boiler is built to accommo date indirect hot water heating coils . . . either instantaneous (tankless) or tank (storage) type.
/A TT - - -____
The bearing brackets consist of two pairs of steel bearing plates, each with necessary gussets, welded to the boiler at the bottom of the water leg. Each gusset has 'A inch hole for securing insulation to the boiler.
Supporting columns consist of four steel H-columns with base plates, one pair for each side of the boiler and eight pairs of steel brackets securely fastened to the boiler to provide for lateral stability ac cording to ASME code construction. Each H-column shall be securely bolted to two pairs of boiler brackets. All column plates have bolt holes for anchoring to the foun dation.
Quality copper tubing is used exclusively in the construc tion of Kewanee coils . . . brazed into bronze fittings. Terminal ends with standard pipe threads... lock-nuts and ring gaskets . . . mounted in front head to avoid interference with breeching, flue doors, piping or controls.
28786
Butl<
d \-ou krunv
American-Standard Industrial Division offers all the major components for air handling, heating, and air conditioning? You can look to one com pany tor your total requirements for systems of any size or degree of complexity . .. whether you need roof ventilators, package units, multi-zone air conditioners, fans, centrifugal refrigerating machines, water chillers, boilers, or dust collec tors. You'd be surprised at the convenience. You talk to product specialists who speak your lan guage. You have one source responsible for qual ity and performance in equipment designed and manufactured to work together.
I
Bulletin 88 1-49B Rev. 20M 6 63 SM
Am e rican-^t andard
SALES OFFICES IN ALL PRINCIPAL CITIES
Executive Offices: Detroit 32, Michigan
In Canada' American-Standard Products (Canada) Ltd. Toronto A, Ontario
Engineered Products AMERICAN RADIATOR A STANDARD SANITARY CORPORATION
28787
Litho m U S.A,