AMERICAN-STANDARD type C boiler stoker fired If any heating boiler has ever earned and won the right to become known as "the standard of the Industry," the now familiar and popular Kewanee Type "C" Boiler, first introduced into the market in 1928, has been accorded this recognition by engineers everywhere. Unmatched for its dependability and efficient service, these compact boilers provide reliable heating for many years with minimum service or attention. Simplified three-pass design extracts maximum heat from the gases... assures highest operating efficiency ... low stack temperatures. Large firebox with self-cleaning, arched, upright crown sheet allows thorough mixing of fuel and air . . . complete combustion before hot gases enter the fire tubes. Second pass is rear to front through direct fire tubes ... the third from front to rear in return tubes. There are no refractory baffles to burn out causing the short circuiting of gases... water content is ample ... and steam space is proportioned for plenty of dry steam. That's why over-all efficiencies of 80% and more are not uncommon with the Kewanee Type "C," and are maintained continuously in actual practice. AMERICAN STANDARD ... a standard . . . first choice of experie type C boiler oil or gas fired type C boiler with front head opening Copy1 'Kdl 1963 by American Radiatoi and Standard Sanitary Corporation Low-Set Design is VERSATILE Where minimum head room is an important factor, the Kewanee Low-Set Type "C" Boiler is the ideal answer. The same dependable features that are characteristic of the standard Type "C" Series are incorporated into this compact, low design, further extending the versatility of this popular boiler model. An opening in the front head, as illustrated at the left, is provided to accommodate a burner and secondary windbox of your choice. This feature together with the Type "C'"s generous firebox eliminates the necessity of high settings. . . provides proper combustion volume to completely burn all grades of oil and gas. The Type "C" 7L200 Series is constructed in accordance with the ASME Low Pressure Boiler Code. Twelve sizes range in gross outputs from 2,160,000 to 14,400,000 Btuh or 64 to 430 hp. 28783 SUPPLY OPENING150 LB. AM. STD. FLANGE DD- D+- Y -B- K rbl-- -- SAFETY VALVE LIFTING OPENINGS LOOP /, A, EE Zt f-2' n. 11" x 15" MANHOLE ON 7L282 AND LARGER SMOKE OUTLET " SURFACE BLOWOFF RIGHT SIDE ONLY - WATER COLUMN CONNECTIONEACH SIDE :of O WASHOUTEACH SIDE P M- cjcT -BB- 'WASHOUTEACH SIDE ratings--mechanically f | rsgt BOILER NUMBER 7L280 SBI gross output--steam --water -- Steam per hour--212F sq. ft. 9000 sq-ft- 14400 MBh. 2160 lb. 2208 SBI net rating--steam --water -- Certified output-- -- Firing rate--150,000 Btu oil --gas sq. ft. \Mq-Bfht-. hp. MBn. ,?EhMBh. 6760 10820 1620 78 2625 22 3280 Heating surface--waterside --fireside sq. ft. 429 sq. ft. 397 Furnace volume--SBI minimum cu. ft. -- net cu. ft. 52.1 65.7 Water content--steam boiler --water boiler lb. 3655 lb. 5055 Safety valve cap. lb. steam per hr. 2625 7L281 10500 16800 2520 2588 7880 12610 1890 92 3060 26 3830 500 463 60.8 75.2 4265 5880 3060 7L282| 12750 ! 20400 3060 3140 9580 15330 2300 111 3718 31 4650 i I j ! i ! i 1 { 608 j 563 1 701 91.0 | 5130 ! 7030 1 3718 | 7L283 15000 24000 3600 3726 11260 18020 2700 131 4374 37 5460 715 662 86.8 104.8 6020 8230 4374 7L284 18750 30000 4500 4623 14060 22500 3370 164 5464 46 6840 893 827 108.5 130.6 7240 9490 5464 - oil, c? fz 7L285 22500 36000 5400 5555 16880 27010 4050 195 6559 54 8200 1072 993 130.2 154.2 8640 11310 6559 7L286 26250 42000 6300 6486 19690 31500 4720 228 7650 64 9560 1250 1157 151.8 189.3 9155 12480 7650 7L287 30000 48000 7200 7418 22510 36020 5400 261 8745 73 10920 1429 1323 173.5 214.4 10835 14610 8745 f f q |r f;- . 7L288 37500 60000 9000 9281 28130 45010 6750 326 10929 91 13670 1786 1654 216 9 256.1 12730 17145 10929 7L289 45000 72000 10800 11109 33750 54000 8100 392 13114 110 16400 2143 1985 260.3 303.4 15470 20735 13114 7L290 52500 84000 12600 12972 39370 62990 9460 456 15300 127 19120 2500 2315 303.6 379.5 17625 23610 15300 7L291 60000 96000 14400 14835 45000 72000 10790 521 17485 146 21900 2857 2645 346.9 429.8 20360 27155 17485 equipment available on ti a il'Z'Ts .1. Three-Pass ASME Code Boiler 2 3* Firetubes 3. Steel Bases 14* 7L280 thru 7L283 17' 7L284 thru 7L289 21' 7L290 thru 7L291 4. Rear Smoke Outlet with Cleanout Openings .5. Gas-Tight Front Flue Door Extension 6 Gasketed and insulated Front Flue Doors 7. Two Firedoors (Stoker Fired Boilers Only) 8. Rear 16" Diameter Access Opening 9. Rear Pyrex Observation Port .10 Lifting Loops .11 FJue.Cieaner and Handle .12 Washout Plug Socket Wrench 13. Manhole 7L282 thru 7L291 ALL UNITS 1. Additional Base Height 2. Structural Steel Supports 3. Bearing Plate Brackets 4. Top or Side Smoke Outlets 5. insulation Retaining Bars 6. Firedoors for Oil or Gas Fired Boilers 7. Damper Assemblies 6. Special Openings 9. Instantaneous or Tank Type Water Heating Coils 10. Low-Set Application for Natural or Induced Draft 11. 60 PSI Water Working Pressure 12. Insulated Steel Jacket 13. Wing Induced Draft Fan 14. Boiler Feed Units 1. Safety Vaive(s) 2. Steam Gauge with Syphon and Cock 3. Kewanee Water Column ..-4. Water Gauges and Try Cocks C C Wheel Handle Type 7L280 thru 7L285 /:> Chain Operated type 7L286 thru 7L291 STEAM TRIMMINGS (Not Mounted) 1. No. 58 Reliance High & Low Alarm Water Column 2. M.M. 157 Combination Water Column, Pump Control and Low Water Cut-Off 3. Chain Operated Water Gauge and Try Cocks 7L280 thru 7L285 1. Relief Valves WATER TRIMMINGS (Not Mounted) 1. M.M. 51-2 Combination Water Feeder and Low Water Cut-Off 2. M.M. 63 Low Water Cut-Off 3. M.M. 150 Low Water Cut-Off 4. Dial Type Pressure Gauge 5. Dial Type Thermometer 28784 BOILER NUMBER Shell Diameter--Inside A--Boiler--width B-- --length C-- --height D-- --length overall --Water line height F--Water column height G--Steam supply height H--Smoke outlet height J--Coil connection height K--Steam supply L--Safety valve*** M --Firebox--length N-- --width P-- --height R--Surface blow-off S--Return height T--Smoke outlet dia. Y--Smokebox depth--front 2-- --rear AA--Base--width BB-- --length CC-- --height DD--Tube replacement space--front EE-- --rear Steam supply size* Return size Outside surface to cover** sq. ft. Approximate dry weight lbs. Breeching diameter--one boiler Stack--diameter --height ft. Breeching diameter--two boilers Stack--diameter -- height ft. 7L280 48" 49* 87 91* 113 77 75 96>/2 75* 80* 36 14 80* 42i/2 34 12 18 24 ii 15 52 90`/2 14 77 73 8 4 145 6600 24 21 50 30 28 60 7L281 7L282 48" 54" 49>/2 100'/2 911/2 126i/2 : 551/2 93`/z 103 1201/2 77 86'/2 75 841/2 96i/2 108 751/2 85 80i/2 90 36 36 18 18 94 421/2 34 87 48/2 37'/2 12 24 18 18 24 28 11 12 15 15 52 58 104 97 14 14 9oy2 86'/2 82/2 79i/2 88 44 162 182 7300 8500 24 28 22 24 60 55 31 34 29 32 70 65 7L283 54" 55`/2 109 103 136 861/2 841/2 108 85 90 36 18 IO2V2 48/2 37`/2 24 18 28 12 15 58 1121/2 14 98 95 8 4 205 9500 28 26 65 36 34 75 7L284 7L285 60" 60" 611/2 109 113'/2 137 ; 611/2 1291/2 1131/2 1571/2 971/2 971/2 951/2 951/2 II81/2 1181/2 941/2 941/2 101 101 36 36 14 16 IOI1/2 531/2 43 122 531/2 43 24 24 21 21 30 30 12 12 16 16 64 64 1121/2 133 17 17 98 1181/2 94 114`/2 88 44 227 255 11400 13000 30 31 28 29 65 70 40 41 37 38 75 80 7L286 66" 671/2 128 122 156 104 102 127 101 107 36 16 120 59 4834 24 21 31 12 16 70 1311/2 17 117 113 8 4 275 15800 35 31 65 44 41 75 7L287 7L288 7L289 7L290 66" 78" 78" 84" 671/2 145 122 173 791/2 130 136 164 791/2 154* 142 1881/2 86 1441/2 1611/2 178/2 104 1151/2 1211/2 138* 102 II31/2 1191/2 1361/2 127 142 148 167 101 1131/2 II91/2 136 107 119 125 142 36 36 36 36 16 16 16 16 137i/2 59 48% 122 71 54* 147 71 6 0y2 1361/j 77 66 24 24 24 24 21 23 23 27 31 39 39 43 12 14 14 14 16 20 20 20 70 82 82 148`/2 . 133* 158 88 . 148 17 17 17 21 134 117 1411/2 131'/2 130 111 135* 1251/2 8 10 10 10 4 6* 6* 6* 310 355 405 460 17400 21100 24700 29700 35 39 41 43 33 36 38 40 75 90 80 100 47 50 44 47 85 100 54 56 50 52 90 110 7L291 84" 86 164 1671/2 198 144* 1421/2 173 142 148 36 16 156 77 71% 24 27 43 14 20 88 1671/2 21 151 145 12 6* 490 33800 46 42 100 60 56 110 150 lb. American-Standard flange `'Includes front head and smokebox One or more valves furnished depending on required capacity t Add 3' for top flue gas outlet. The contractor shall furnish and install............. No. 7L2...... Kewanee Type C Boiler(s) for (oil) (gas) (stoker) firing. Boiler(s) shall contain not less than............. sq. feet of healing surface and have a gross SBI output of............. Btuh and shall be equipped with............... in. high steel base. NOTE: When Low-Set Type C 7L-200 Series is specifiedr delete above paragraph and insert: The contractor shall furnish and install............. No. 7L2...... Kewanee Low-Set Type C Boiler(s) for (oil) (gas) firing. Boiler(s) shall contain not less than............. sq. ft. of heating surface and have a gross SBI output of............. Btuh. Boiler(s) shall be equipped with.............. in. high channel base and provided with (circular) (arched) burner opening in front water leg. Boiler shall have minimum of.............cu. ft. of firebox volume above the bottom of the water leg. Boiler shall have arched crown sheet, shall be of three pass firebox design, and constructed in accordance with the A.S.M.E. code for (15 lb. steam) (30 lb. water). Boiler shall be inspected during con struction by an authorized inspector and after completion shah be subjected to a 60 lb. hydrostatic test and stamped with all identifying markings and symbols as required by the latest edition of the A.S.M.E. code. Boiler to be furnished with gas tight front flue doors of size permitting easy access to all tubes and lined with refractory securely keyed in place. Rear smoke box shall have cleanout openings on both sides with smoke outlet at (rear) (top) (r.h. side) (l.h. side) of smokebox. 16" Dia. rear access plate, refractory lined, with observation port in rear water leg. Boiler trimmings shall consist of the following: FOR STEAM: Safety valve(s), steam gauge with siphon and cock, Kewanee water column with hand operated water gauge and try cock assembly--chain operated on 7L-286 and larger. FOR WATER: Relief valve(s) as required by A.S.M.E. code for low pressure boilers. NOTE: When a high setting and independent supporting structure is desired, use either of the following options: Not applicable to Low-Set Boilers. Structural Steel Supports: Boiler(s) shall be furnished less steel base(s) but with structural steel supports for setting boiler(s) independently of masonry base(s). Distance from boiler room floor to bottom of water leg to be............. ". Structural supports to consist of four H-columns with base plates, one pair each side of boiler and eight pairs of steel brackets securely fastened to the boiler to provide lateral stability according to A.S.M.E. code construction. Each H-column shall be securely bolted to two pairs of boiler brackets. Bearing Plate Brackets: Boiler(s) shall be furnished less steel bases but with bearing plate brackets for supporting boiler on masonry base(s). Bearing brackets to consist of two pairs of steel bearing plates, each with necessary gussets, welded to the bailer at the bottom of water leg. Each gusset to have a Vi in. hole for wiring insulation to the boiler. 28785 built-in features that make 1. 150 pound American-Standard flange--accepts flanged piping and fittings. EEWAN'WWe 2. Generous steam space--provides ample storage for dry steam. l beeitter J 3. Extensive unbroken steam disengaging area--assures steady water line and prevents priming. - 4. Water line--well above top row of firetubes. 5. Smoke outlet--rear outlet stand- ---- ard. Jop, right or left hand outlet available as optional equipment. 6. Clean out doors--one on each side of smoke box. 7. Wide water legs--progressively wider at top--permitting free and rapid circulation. Arched crown sheet--fully effec tive combustion space on fire side-self cleaning and draining on water side. 9. Large furnace volume --Ex tremely low heat release assures quiet and complete combustion. 10. Kewanee water column--hand operated gage and try cocks. Chain operated on 7L-286 and larger. 11. Three inch firetubes--rolled and flared for tight, permanent fit-- No welded tube ends. 12. Insulated flue doors provide ready access to all fire tubes. 13. Large water content--guarantees adequate reserve for fluctuating loads--steam or hot water. 14. Washout plugs--Hollow brass with rubber gaskets. 15. Steel base--flanged and rein forced bolted panel construction. 16. Base Flange--with holes on 9" centers for securing insulation covering. BOILER SUPPORTING BRACKETS AHO SUPPORTING COLUMNS Bearing brackets support the boiler on a masonry base. Structural steel columns furnish support independent of masonry furnace base. Illustrations show methods of application only. Specific details are available from your American-Standard Sales Office. WATER HEATING COILS The Kewanee Type C Boiler is built to accommo date indirect hot water heating coils . . . either instantaneous (tankless) or tank (storage) type. /A TT - - -____ The bearing brackets consist of two pairs of steel bearing plates, each with necessary gussets, welded to the boiler at the bottom of the water leg. Each gusset has 'A inch hole for securing insulation to the boiler. Supporting columns consist of four steel H-columns with base plates, one pair for each side of the boiler and eight pairs of steel brackets securely fastened to the boiler to provide for lateral stability ac cording to ASME code construction. Each H-column shall be securely bolted to two pairs of boiler brackets. All column plates have bolt holes for anchoring to the foun dation. Quality copper tubing is used exclusively in the construc tion of Kewanee coils . . . brazed into bronze fittings. Terminal ends with standard pipe threads... lock-nuts and ring gaskets . . . mounted in front head to avoid interference with breeching, flue doors, piping or controls. 28786 Butl< d \-ou krunv American-Standard Industrial Division offers all the major components for air handling, heating, and air conditioning? You can look to one com pany tor your total requirements for systems of any size or degree of complexity . .. whether you need roof ventilators, package units, multi-zone air conditioners, fans, centrifugal refrigerating machines, water chillers, boilers, or dust collec tors. You'd be surprised at the convenience. You talk to product specialists who speak your lan guage. You have one source responsible for qual ity and performance in equipment designed and manufactured to work together. I Bulletin 88 1-49B Rev. 20M 6 63 SM Am e rican-^t andard SALES OFFICES IN ALL PRINCIPAL CITIES Executive Offices: Detroit 32, Michigan In Canada' American-Standard Products (Canada) Ltd. Toronto A, Ontario Engineered Products AMERICAN RADIATOR A STANDARD SANITARY CORPORATION 28787 Litho m U S.A,