AMERICAN INSULATED WIRE CORP. PAWTUCKET, R.l.
ES- 11295
TYPE: UL Listed AWM Style 5195 Hsving AWM 5036 (AF Stvlc) Inner Covered With 10 Mil PVC Jacket
APPROY.
REV. DATE er
0 NrJ\ pn'v
REASON
CUSTOMER: Leviton Mfg. Co,
ORDER NO: 78559
6-
TABLE I
I ten Ho.
1 2 3
Size AVG
18 18 18 .
Stranding
Solid 7 x.0152" 16 x.010"
Cond. Lay Hax.
--
.73'* 2"
Cond. O.D.
.0403" .046" ,048"
Asbestos
Tape
Wsll
Width + .003" i"
3/8" .030"
3/8" 3/8"
>030" .030"
Dianeter Over Asbestos
.108" + .003" .111" + .003" .113" + .003"
Diameter Over PVC
Jacket . + .003"
.130" .133" .135"-
^A 5
6
16 16 16
7 14 8 14 9 14
10 12 11 . 12 12 12
13 10 14 10 15 10
Solid 7 x.0192" 26 x.010"
.92" 2*'
.0508" .058" .060"
3/8" 7/16" 7/16"
Solid 7 x.0242" 41 x.010"
___
1.1" 2"
.0641" .073" .078"
7/16" 9/16" 9/16"
Solid 7 x.0305" 1.4" 65 x.010" 2"
.0808" .092" .101"
9/16" 3/4" 3/4"
Solid 7 x.0385" 104 x.010"
--
1.8" 2.5"
.1019" .116" .126"
3/4" 3/4" 3/4"
.030" .030" .030"
.030" .030" .030"
.045" .045" .045"
.045" .045" .045"
.119" + .003" .122" + .003" .124" + .003"
.132" + .003" .138" + .003" .143" + .003"
.181" + .005" .186" + .005" .195" + .005"
.202" + .005" .208" + .005" .218" + .005"
.141" .144" .146"
.154" .160" .165"
.203" . 208" .217"
.224" .230" .240"
1. Conductor: Annealed Copper Solid or stranded. Bare or tinned. Dimensions Per Table I. I..H.L.
2. Separator: A Brown Cellulose Acetate Tape .002" shall be wrapped helically with a 502 overlap. See Table I for Width of Tape.
3. Insulation: Felted Asbestos 1*238, 1500 Crain Underwriters Quality shall be applied directly over the taped conductor. Sec TABLE 1 for Walla and Dimensions.
(
SC-ELEC-08080
AMERtLAN INMJLAIDU *mc v-unr. PAWTUCKET, R.I. -2- -
ES-11295
' *. Finish Over Asbestos: The insulated conductor shall be saturated vith AT WAX,
t, Colored os ordered.
*
NOTE: Paragraph 2, 3 4 shall be done in 1 operation,
5. Outer Jacket: Outer Jacket to be colored as ordered.
For 60 C use Apex 130 for standard colors and Apex 586 for Clear and wtallic colors
For 105 C use Apex 842'for standard colors and Apex 716 for Clear and metallic coiora
Norn. Wall: .011" + .002"
Nora. O.D.: See Table 1
NOTE: A 3-foot aaraple rauat be sent to each Q.C. Area for Inspection
6. Inspection:
Spark Test: Inner:
6000 Volts
Per UL-AWK 5036 (AF Style)
I.
`
Continuity: 1001 7. Packaging: Standard Coosnercial Practice or as specified.
*
Tag Harkings: Wire to he tagged and labelled as follows:
1. American Insulated Wire Corp.
2. Sir.o AWC 150 C 300 Volts (1/32" In. 18-UAWC) or (3/6*" Ins. 12-10AWG)
3. Style 5195 With 10 MIL THICK FVC JXT.
*. Appliance Wiring Material suitable for the Internal Wiring of Heating Appliances.
5. As non-enclo8ed visible wires other than lamp-supported lamp holders or enclosed wiring.
r &%r
. W1
<3
6. UL Appliance Wiring Materiel l.abcla equal to the footage + 101.
J*. g
Written By: J. Medeiros Checked By: A, retit
i