Document pOgO6YMRQEVmvyRYXMd8LpmE
ASBESTOS STANDARD REQUIREMENTS
OSHA STANDARD - 1910.1001 Effective 1976
PERMISSIBLE EXPOSURE LIMITS (PEL)
8 Hour TWA: 2.0 fibers (>5mM)/cc
Ceiling:
10 fibers (>5raM)/cc
PARTICULAR TOOLS
Hand operated tools producing/releasing asbestos fibers in excess of PEL SHALL BE provided with local exhaust ventilation systems.
WORK PRACTICES
A. Wet Methods - Asbestos must be handled in a wet state sufficient to prevent the emission of fibers in excess of the PEL.
B. Particular Products Operations - No asbestos containing material shall be removed from containers in which it was shipped without either being wetted or enclosed to prevent fiber release
C. Spraying, Demolition, or Removal - Employees engaged in demolition activities SHALL BE provided with and required to wear respiratory protection and protective clothing.
PERSONAL PROTECTIVE EQUIPMENT A. Respiratory Protection
AIRBORNE CONCENTRATION OF ASBESTOS (TWA)
Up to 20 fibers/cc (10 x PEL)
Uo to 200 fibers/cc (100 x PEL)
6113 17727
RESPIRATOR REQUIRED
Reusable or Single use air purifying respirator Full face or powered air purifying respirator
BCC~387
LAM021478
2- -
IV. PERSONAL PROTECTIVE EQUIPMENT CONTINUED
A. Respiratory Protection
AIRBORNE CONCENTRATION OF ASBESTOS (TWA)
RESPIRATOR REQUIRED
Greater than 200 fibers/cc
Type "C" Supplied air respirator (Continuous flow
or pressure demand)
NOTE: All employees must have physician's determination of ability to wear respiratory protection.
Employer must have respiratory protection program in accordance with the ANSI Z88.2 standard as well as 1910.134.
B. Special Clothing - Must be worn by all exposed in excess of Ceiling limit (coveralls, head covering, gloves, and foot coverings). Contaminated clothing must be disposed of in sealed labeled containers.
V. MONITORING
A. Personal Monitoring - for both 8 hour TWA and Ceiling determinations.
B. Environmental Monitoring - for both 8 hour TWA and Ceiling determinations.
VI.
CAUTION SIGNS & LABELS
A. Required where levels exceed PEL.
B. Posted at all approaches to areas containing excessive concentrations of airborne asbestos fibers.
C. Posted at such a distance as to allow employee to read and take necessary protective steps before entering areas marked by the signs.
D. See 1910.1001 g. ii for sign specifications.
6113 17728
BCC-388
LAM021479
-3-
VI. CAUTION SIGNS & LABELS CONTINUED
E. Caution labels must be affixed to all scrap, waste, or debris containing asbestos fibers or to their containers.
F. See 1910.1001 g. 2. ii for label specification.
VII.
HOUSEKEEPING
A. Cleaning - all external surfaces shall be kept free from accumulations of asbestos fibers.
B. Waste Disposal procedures shall be according to established plant procedures.
VIII.
TRAINING
A. Minimum training is to include:
(1) Health effects associated with asbestos exposure.
(2) Relationship between asbestos and smoking in producing lung cancer.
(3) Jobs/Tasks that could result in exposure to asbestos and necessary protection steps to minimize exposure.
(4) Purpose, proper use, fitting instructions and limitations of respirators permitted by standard.
(5) Review of standard requirements.
4/2/84
6113 17729
BGC2389
LAM021480