Document pLBb1axwoO4MKeYzRwQob9BD

DownloadRandom document
Basic structure of "SIPHOREX" Refrigerant side fin Air Flow Air side fin "SIPHOREX" is our product name of 2phase (boiling & condensation) cooling system. Condensation part (Plate-fin heat exchanger) Condensation Heat Heat Air Flow IGBT Connecting part Gas Working fluid F-gas) enclosed Boiling part (Cooling plate) Boiling Heat Heat Copyright Sumitomo Precision Products Co., Ltd. All rights reserved. 1 Applications for IGBT cooling SIPHOREX is inside for cooling IGBTs Power AVAF inverter Motor IGBT High speed train Pump Station Elevator Pipeline for Oil&Gas Blowers for air dryer and air conveyor Copyright Sumitomo Precision Products Co., Ltd. All rights reserved. 2 Other features of "SIPHOREX" High Reliability Form our experience of 25 years, SIPHOREX has experienced no failure, besides external reason (e.g. corrosive environment, external force) Uniform cooling surface temperature Since temperature of contained liquid inside becomes uniform with saturation temperature, cooling surface also becomes almost uniform. Sub-zero ambient temperature OK. Since freezing point of refrigerant is very low, SIPHOREX does work in sub-zero ambient. (more than -40degC possible) Copyright Sumitomo Precision Products Co., Ltd. All rights reserved. 3 Suggestions for high-performance CPU cooler Hope to increase the processing capacity and speed of equipment. (increasing CPU heat value) Hope to reduce the power consumption of air conditioning. (raising the room temperature setting value) However, you do not want to use the water cooling method. (leakage, maintenance, power consumption). I wish a high-performance air-cooled cooler... Data center The performance of the cooler is low, Acceptable CPU temp.: 70 Temperature rise value T: 45C Need to keep the room temperature low Outdoor unit Air conditioner Room temperature 25 Server rack CPU cooler The performance of the cooler is good, Acceptable CPU temp.: 70 Temperature rise value T: 30C The room temperature can be kept high!! Copyright Sumitomo Precision Products Co., Ltd. All rights reserved. Cooling tower, etc. Air conditioner Room temperature 40 Server rack 4 Suggestions for high-performance CPU cooler Cooling method comparison Heat sink Low cost Low cooling performance Liquid cooling High cooling performance Need pipng, Maintenance Liquid immersion Cooling performance High Large space, High cost Air cooling with phase change Siphorex for CPU/GPU Cooling performance similar to liquid cooling Smaller space than liquid cooling / immersion Higher cost than heatsink Possible for 1000W If height of cooler need to be low, Separate type Air If cooler needs to be on CPU, Integrated type Air Evaporator Condenser CPU Copyright Sumitomo Precision Products Co., Ltd. All rights reserved. Condense CPU CPU Evaporate 5 Status of developing CPUGPU Thermal design power [W] (i.e. heat loss from CPU/GPU) Intel CPU for PC Status of developing CPU/GPU Intel CPU for Server AMD CPU for PC AMD CPU for Server NVIDIA GPU Targeted CPU for boiling heat transfer New release Schedule CPU Conventionally, the air cooling is adopted up to 300W.. In case 300W is exceeded, the water cooling may be considered. Jul.1998 Jan.2004 Jul.2009 Dec.2014 Time Jun.2020 <CPU status> Planned release of newly developed CPU made by Intel (70% share) "Sapphire Rapids" by the second quarter of 2022 In 2023, "Emerald Rapids" In 2024, "Granite Rapids" and "Sierra Forest" Planned release of newly developed CPU made by AMD (25% share) In 2022, "Genoa" In 2023, "Bergamo" In 2024, "Turin" Dec.2025 Copyright Sumitomo Precision Products Co., Ltd. All rights reserved. 6 Summary of appeal points <Compare with Other Cooling Specifications> Air-cooled heat sink Air cool SIPHOREX CAPEX Heat sink + fan SIPHOREX + fan OPEX Electricity cost/year Maintenance costs > Power cost/year Maintenance cost Water cooling Cooler + piping + pump + radiator Electricity cost/year Maintenance costs Heat value 300W <Appeal Points> For air-cooled specifications High load heat can be removed Reduce power consumption and noise by reducing fan air volume Against the water cooling specifications No need for pumps and piping No risk of damage to electronic equipment due to fluid leaks Easy maintenance CPU spec image Motherboard in the server Copyright Sumitomo Precision Products Co., Ltd. All rights reserved. 700W According to the specifications Compact, high-performance phase-change CPU cooler (SIPHOREX) developed for CPU cooling 7 applications in datacenter servers