Document pDRwQdNRzM0MpZJMJ8XNQO4w

W idth Length H e ig h t Over-all Required Length Casing H e ig h t Casing |No. 1 Filters Smoke Pipe Dia. Air Conditioning The Waterman-Waterbury Co. Minneapolis 13, Minnesota Manufacturers of WATERBURY Coal, Oil and Gas Fired Furnaces and Air Conditioning Equipment WATERBURY GAS-TITE FURNACE A 100 Series The welded steel furnace body keeps dust, smoke and fumes out of the air stream. A large combustion chamber and radiator with long fire travel insure efficiency and economy. Also furnished in a complete home Air Conditioner. Gravity Size BTU/HR Body Dia. A120 A122 A124 A127 85.000 94,200 105,100 136.500 20 22 24 27 Body Hgt. 52 62 52 59 Round Galv. Dia. 41 43 45 49 Round Galv. Hgt 65 65 65 72 Sq. In. Leader Pipe 470 524 586 758 Size Sq Casing 38x38 40x40 42x42 46x46 Size Sq Casing Outlet 34x34 36x36 38x38 42x42 Sq Cas ing ' Hgt 52 52 52 59 Heating Surface Sq Ft 35.7 39.6 44.3 57.4 8' 8' 9' 9' Gastite Air Conditioner Air Con Output Width ditioner BTU- Cas Size HR ing A120- 9 95.400 A120-10 95.40C A122- 9 105,800 A122-I0 105.800 A124-10 118,200 A124-12 118.200 A127-12 153.000 A127-15 153.000 38' 38 40 40 42 42 46 46 50' 50 54 54 60 60 62 62 Size Size Outlet Inlet Open Open ing ing 52* 28x34 16x34 2 52 28x34 16x34 2 52 28x36 20x36 2 52 28x36 20x36 2 52 34x38 20x38 2 52 34x38 20x38 2 59 34x42 22x42 2 59 34x42 22x42 2 Size Each Filter CFM Range 16x20 16x20 20x25 20x25 20x25 20x25 20x25 20x25 400- 800 600-1200 400- 800 600-1200 600-1200 1000-2000 1000-2000 1800-2600 WATERBURY GAS FIRED AIR CONDITIONER The latest achievement of Waterbury's engineers, designed specifically for gas. Completely automatic--filtered, humidi fied forced air--enclosed in a compact, baked enamel casing. Can also be furnished for F*rppane or Butane. Input Size Rating BTU Blower CFM BTU Output Range Per Hr. Size Outlet Open ing Size Return Inlet Open ing No. of Fil ters Size each FUter Flue Pipe Dia meter 6413A-9 HBB 6415A-10 90,000 72.000 400 to 800 28' 59' 48' 24x23 24x16 2 16x25 90,000 72,000 400 to 800 28' 28* 67' 24x24 22x15 2 16x25 120,000 97,000 600 to 1,200 28' 61' 53' 24x23 24x18 120,000 97,000 600 to 1,200 30* 30' 76' 26x26 22x15 2 2 16x25 16x25 150,000 120,000 1.000 to 2,000 34' 71' 53' 30x30 22x30 150,000 120.00C 1,000 to2,OOC 34' 34' 81' 30x30 22x20 180,000 144,OOC l,800to2,60C 55' 60* 24x51 36x28 6430A-18B 240,COO 192, OOt 3,000to4,200 55' 60* 58' 24x51 36x28 2 2 4 4 20x25 7' 20x25 7' 16x20 2-5 to 6 2-6 to 7 H' 1090 ip u t Ratin Gal Oil per H r utput C a p a c ity B tu per Hi at Bonnet ength Casing ire O utlet Oponing iee R e tu rn In le t Opening 'istance between Opening o. of Filters ze each F ilte r iam. Smok Pipe Air Conditioning Automatic Equipment Heating Systems The Waterman-Waterbury Co. Minneapolis 13 Minnesota WATERBURY 6300 Series OIL FIRED AIR CONDITIONER Completely automatic oil heat with forced, filtered, humidi fied air, all enclosed in one compact casing finished in baked enamel. Lm Size w s! 4-S 23 t*>. *30 O a - CD GO Q 6313A-8B 6315A-10B 6313A-9HBB* 6315A-10HBB* 6318- 12B 6318-12HBB* .75 1.00 .75 1.25 1.35 1.35 75,000 28* 59' 48' 24x23 24x16 2H' 100,000 28* 61' 53' 24x23 24x18 2H' 75,000 28* 28' 67' 24x24 22x15 V 115,000 30* w 76' 26x26 22x15 135,000 34' 71' 63' 30x30 22x30 V 135.000 34' 34' 81' 30x30 22x30 * IIB indicatea o Hi-boy model Z CO Q 2 16x25 2 16x25 2 16x25 2 16x25 2 20x25 2 20x25 6' 7' 6' 7' 7' 7' WATERBURY GAS GRAVITY FURNACE Size Furnace 6413A-G 64I5A-G 6418A-C Input Rating Btu per Hr 80,000 110,000 130,000 Output RatingSq In. Warm Air Pipe 60,000 82,500 97,500 Width In. 28' 30* 40' Length In. Height Overall In. 28' 48' 30' 53' 37' 53' Size Outlet Open ing 24x24 26x26 36x33 Rec. Size Gas Flue Connec-. Pipe tion Re Diam. quired In. 5' M" 6' mt . 7' M* SEAMLESS OIL FIRED FURNACE BODY Specially engineered for oil firing only, it may be used as a gravity circulating pipe furnace. It is the heating element of the Waterbury Oil Fired Air Conditioners. Specifications Waterbury Oil Fixed Air: Conditioners Height l Over-all Size Input Rating Gal. OiL per Hr. BTU Output per Hr. Width Less Front Hoodl Lgth Over all 1322-12B 1322-I5B 1324-15B 1324-I8B 1327-18B 1327-21 1330-21 1333-21 1336-34 1.5 164,177 1.5 164,177 2.0 216.903 2.0 218.903 2.5 - 273,609 2.5 273,609 3.0 328,354 3.5 383,080 4.0 437.805 44' 66' 55' 44 80 55 48 ' 80 55 46 60 55 52 84 55 52 100 55 56 104 62 60 108 62 66 116 72 t Burner hood all sizes is 24 in. wide, 10 in. deep. Size Outlet Opening Return Inlet Open ings .No/ of * Fil ters Size . each Filter . o > .d C/lO. Q 40x40 18x24 2 16x25 8' 40x40 28x36 4 20x20 8 44x44 28x36 4 20x20 8 44x44 28x36 4 20x20 8 48x48 28x36 4 20x20 9 48x48 38x44 6 16x25 9 52x52 38x44 6 16x25 9 56x56 38x44 6 16x25 9 62x62 46x48 6 20x25 9 CFM Range 1000-2000 1800-2600 1800-2600 3000-4200 3000-4200 4600-6200 4600-6200 4600-6200 5000-8000 GAS CONVERSION BURNER A real gas burner, the same as used in the Gas Air Conditioner. Number G-200 Maximum Btu Input- Maximum pubic Feet of * MixedGaa-v Maximum Cubic Feet of Manuf'd Gas . 200,000 250- . . 360 1091