Document pBqR1Gx1rzvRO073Rg6nje69k

300 CHAPTER 12 ' 1950'Guide Cooling Load 301 Latent Load Infiltration 67 cfm X 4840 X 0.0071 =......... ...,...........2,300 People 85 X 250 =............................................................................ 21,250 Total Latent Space Load.............................................................. ........... 23,550 Ventilation Air Sensible 1275 cfm X 1.08 X 15 =.......................................................... ........ Latent 1275 cfm X 4840 X 0.0071 =................................................................... 20,700 43,800 Grand Total Load.................................................................... 271,995 qa = latent head load due to moisture transmission through materials, Btu per (hr) (sq ft). q, = instantaneous sensible heat load, Btu per hour. qt = q. + Btu per hour. q, = the heat-moisture ratio of the room load based upon the ratio of the total heat added, divided by the required rate of water-vapor removed, r a fraction of incident radiation reflected from glass surface, dimensionless. t, = sol-air temperature, Fahrenheit degrees. LETTER SYMBOLS USED IN CHAPTER 12 0 = solar altitude, degrees. y = difference between the azimuth angle of an outdoor wall and the azimuth angle of the horizontal projection of the sun's rays, degrees. li .= permeability of material to moisture transmission, grains per (sq ft) (hr) (inchHg). to* = sol-air temperature at a time earlier than the time for which heat gain is being found by an amount that is equal to the time lag of the wall or roof, Fahren heit degrees. t, = indoor air temperature, Fahrenheit degrees. = temperature of outer surface of building, Fahrenheit degrees. ta = 24-hr cyclic average sol-air temperature, Fahrenheit degrees. V= amplitude decrement factor, a variable depending on thickness, material, and t, = fm + (f* -- <m), net equivalent outdoor temperature for combined periodic orientation of the wall or roof dimensionless. and mean heat flow, Fahrenheit degrees. . $ = angle of incidence for sun's rays striking a surface, degrees. t = fraction of incident radiant energy transmitted through a glass section, dimensionless. A = area across which heat is being transferred, square feet. a = fraction of incident radiant energy absorbed within a glass section, dimension less. . U = overall coefficient of heat transfer of a structural section, Btu per (square foot) (hour) (Fahrenheit degree). !>,, = volume of outdoor air per pound of dry air, cubic feet. w = width of window, feet. Wi = humidity ratio of indoor-air, pounds moisture per pound of dry air. ; 6 '= fraction of incident radiant energy absorbed by a non-transparent surface, W0 = humidity ratio of outdoor air, pounds moisture per pound of dry air. dimensionless. e = ratio of direct solar radiation to sky radiation falling on a horizontal surface, REFERENCES dimensionless. /i = unit convective conductance for indoor surface = film coefficient of heat trans fer of indoor air, Btu per (square foot) (hour) (Fahrenheit degree). /. = unit convective conductance for outdoor surface -- film coefficient of heat transfer of outdoor air, Btu per (square foot) (hour) (Fahrenheit degree). Pi .= fraction of total window area receiving direct solar radiation when shaded by 1 Application Engineering Standards for Air Conditioning for Comfort (Air Con ditioning and Refrigerating Machinery Association, Inc., 1947, p. 4-7). 1 Proposed Standard Solar Radiation Curves for Engineering Use, by P. Moon (Journal of the Franklin Institute, November, 1940, Vol. 230, No. 5, p. 583-617). . * Summer Cooling for Comfort as Affected by Solar Radiation, by G. A. Hendrick son and J. H. Walker (Heating and Ventilating, Vol. 29, No. 11, November, 1932, p. 14-21). ' window reveal, dimensionless., hi = enthalpy of indoor air per pound of dry air, Btu per pound, 4 Dynamic Meteorology, by B. Haurwitz (McGraw-Hill Book Co., Inc., New York, 1941). ho = enthalpy of outdoor air per pound of dry air, Btu per pound. I& = direct solar radiation incident upon a surface at any angle of incidence, Btu 4 Summer Weather Data and Sol-Air Temperature--Study of Data for New York City, by C. O. Mackey and E. B. Watson (A.S.H.V.E. Transactions, Vol. 51,1945, p. 75). per (square foot) (hour). 8 AB.H.V.E. Research Report No. 1268--Summer Weather Data and Sol-Air /,, = direct solar radiation incident on . a surface at normal incidence, Btu per (square foot) (hour). Temperature--Study of Data for Lincoln, Nebr., by C. O. Mackey (A.S.H.V.E. Transactions, Vol. 51, 1945, p. 93). 7 A.S.H.V.E. Research Report No. 923--Heat Transmission as Influenced by /, = sky radiation incident upon a surface, Btu per (square foot) (hour). Heat Capacity and Solar Radiation, by F. C. Houghten, J. L. Blackshaw, E. M. /, = /. + It, Btu per (square foot) (hour). ' ; K = cosine of angle of incidence for direct solar radiation striking a surface, dimen Pugh and Paul McDermott (A.S.H.V.E. Transactions, Vol. 38, 1932, p. 231). Ef fect of Heat Storage and Variation in Outdoor Temperature and Solar Intensity on Heat Transfer Through Walls, by J. S. Alford, J. E. Ryan and F. O. Urban sionless. (A.S.H.V.E. Transactions, Vol. 45,1939, p. 369). Periodic Heat Flow in Building k = thermal conductivity of building material, Btu per (square foot) (hour) Walls Determined by Electrical Analogy Method, by Victor Paschkis (A.S.H.V.E. Transactions, Vol. 48, 1942, p. 75). Periodic Heat Flow--Homogeneous Walls or (Fahrenheit degree per foot). .. Roofs, by C. O. Mackey and L. T. Wright, Jr. (A.S.H.V.E. Transactions, Vol. 50, i t L = thickness of building material, feet. 1944, p. 293). Periodic Heat Flow--Composite Walls or Roofs, by C. O. Mackey and L. T. Wright, Jr. (A.S.H.V.E. Transactions, Vol. 52, 1946, No. 1299). 1 = height of window, feet. 8 A.SiH.V.E. Research Report No. 1002--Cooling Requirements of Single Rooms Q = rate of entry of outdoor air, cubic feet per minute. in a Modern Office Building, by F. C. Houghten, Carl Gutberlet, and Albert J. Wahl Syii a* !] Q,, = required air quantity through conditioning equipment, cubic feet per minute. q = instantaneous rate of heat transfer, Btu per hour. (A.S.H.V.E. Transactions, Vol. 41, 1935, p. 53). 9 Study of Actual vs. Predicted Cooling Load on An Air Conditioning System, by James N. Livermore (A.S.H.V.E. Transactions, Vol. 49,1943, p. 287). ; ! j q, a instantaneous latent heat load, Btu per hour. 10 A.S.H.V.E. Research Report No. 1195--Heat Gain Through Walls and Roofs .t i\