Document pBnBXr9d8nORBp4JYYJXJbgk6

102 CHAPTER 5 1952 Gaide Rt, and into the water stream through tho convection resistance, Rt. Note tiie analogy to the direct current electrical circuit problem. ^ A temperature (potential) drop is required to overcome these resistances to the flow' of thermal current, The total resistance to heat transfer, Rt, hour. Fahrenheit degrees per Btu, is_ the.summation of. the individual resistances: . ; - : Rr -- Ry 4- Rt 4- ; (9) where the resultant parallel resistance Rt is obtained from: f. JJ R, Rr+ Ro (10) Provided the individual resistances' may be evaluated, the total resistance can be obtained from this relation. Then the heat transfer for the length of pipe (N, ft) can be established by the relation r . .i qn (Btu per hour) = ^'> Rt For a unit length of the pipe the heat transfer rate is : --0 Btuper (hour) (foot) N (to - td RtN; . < (11) (12) The temperature,drop, At, through an individual resistance may then be calculated from the relation: ' " At Rgn ' (13) where R is the resistance in question. The problem is now reduced to one of evaluating the individual resist ances of the system. This entails suitable manipulation of the rate Equa tions 1, 2 and 3 to produce expressions of the form: ' ......... q = At R (14) where q is the heat transfer rate, and At is the potential[drop or tempera ture difference through the resistance R. Table 6 lists such solutions for six different conduction systems. Table 2 in Chapter 9 and Table 1 of this chapter indicate the magnitudes of the thermal conductivities, fc, to be employed in the expressions of Table 6, after dividing k by 12. The solution applicable to the problem depicted in Fig. 8, for the cal culation of Rt and Rt, is case 2 in Table 6. Thus for a l ft length of 2 in. nominal sizb pipe (I. D. = 2.067 in., O. D: = 2.375 in.) insulated with 1 in. of material having a conductivity of 0.025: 1.188 log. Rt = 2ir X 1.033 26 X 1 = 8.5 X 10-4 (hr) (F deg) per Btu. 2.188 l0g' L188 Rt = 2ir X 0.025. X J = 3.9 (hr) (F deg) per Btu.. Heat Transfer 103 The convection:resistances to heat transfer from the'.pijje wall to the cold-Water, Er, and from thb air to the surface of the insulating material, Rt, are dependent on the flow conditions prevailing at these surfaces, and on the thermal properties of the fluids.; These resistances are also directly dependent upon the temperature distribution, and for this reason it is necessary first, to guess on the basis of the problem statement, a tempera ture distribution upon which to base the. initial calculations. Since the values of A,* for heat transfer between water and pipe walls are relatively high in this temperature range, it is logical to assume only a small tempera ture difference between the temperature of the fluid body and the tempera ture of the pipe wall. For the purpose of an initial guess, this temperature difference will be assumed to be 2 deg. On the other hand, h, for heat transfer from air to a body is relatively small, and a higher temperature difference would be expected between these masses. The value initially assumed here will be 20 deg. In summary, the temperature distribution in the system is assumed as follows: Fluid temperature = 34 F. i.,! Inner pipe wall temperature = 36 F. Outer insulation surface temperature = 100 F. Ambient air temperature = 120 F. With these assumptions and the problem statement, it is now possible to calculate values for the convective resistances. If it is found in the ultimate solution of the problem that the temperature distribution is different from that assumed, it will then be necessary to repeat the solution procedure. If reference now be made to Table 2, it is found that jCase S of this, table , is a system similar to that encountered in the convection betweenithei water and the pipes Wall.. The equation- for this case is the ^Slowing:-; \ where uJsV K = 13.9(tI),,-M* -JJ0r":* - ' - !H' (15) tta = 5 fps ~ 2.067 D = -- = 0.1725 ft U = 34 + 1 35F A.= 13.9 X 6.9 X 3.62 0.703 494 Btu per (hr) (sq ft) (F deg). This heat transfer rate is through the inner surface of. the pipe and it is, therefore, this area that determines the resistance R\. ^d therefore = 0.542 sq ft per unit length of pipe, ,1 . Ri hcA 494 X 0.512 Rt = 3.73 X io-* (hr) (F deg) per Btu. \