Document pBa9Lj10x5gwY8R3Na9nmxd1w
er/ar Inc.
6621 ELECTRONIC DRIVE SPRINGFIELD, VIRGINIA 22151
October 27, 1975
Telephone 703-354-3350
Mr. D. B. Hosrner Director of Environmental Protection Monsanto Industrial Chemicals Company 800 North Lindbergh Boulevard St. Louis, Missouri 63166
.'
. '
Dear Mr. Hosmsr:
Enclosed is a draft of our description of your PCB operation at Sauget, ,Illinois, as discussed with Messrs. A.E. Leisy and W.L. Snull during rry visit on October 8. Please review it for technical accuracy and return it with any comments you may have as soon as possible.
We have not yet received the details on the composition of the
effluents, from-your PCB related facilities. You will note that the "plant
effluent" section covered on page 9 is incomplete. As discussed with your
Mr. Pearley on October 23, in order to expedite the completion of this report
you will bridge this gap and will provide us with this information with your
aoirrrents.
To the best of our knowledge this report does not include any PCB information that can be claimed to be trade secret and confidential informa tion by Monsanto Company. However, if you find seme specifics in this write up that you choose to consider as confidential please do identify and label the information as such so we would delete it frcm our final report.
Thank you for your cooperation and assistance in this study.
Very truly yours,
(Mrs.) Gayaneh Oontos Chemical Engineer
cc: W.B. Papageorge, Manager, Product Acceptability Monsanto Industrial Chemicals Company 800 N. Lindbergh Boulevard , St. Louis, Missouri 63166
'/mt. R.W. Flint, Plant Manager
W.G. Kruamrich Plant Sauget, Illinois 62201
CC:nd
STLCOPCB4076976
ver/ar Inc.
- > - \
..
1.
MANUFACTURING PROCESS - POLYCHLORINATED BIPHENYLS (PCBs)
Process Description
.
Monsanto, the sole domestic manufacturer of PCBs, manufactures this
chemical in their Sauget, Illinois plant. The basic raw material is biphenyl
which is manufactured from pure benzene in another Monsanto plant. The PCB
manufacturing operation is conducted in two steps. First -biphenyl is chlorinated
with anhydrous chlorine in presence of ferric chloride to produce crude
PCBs and then the crude PCBs are distilled to obtain the finished product. A
schematic flow diagram of this process is given in Figure 1.
.
. The reaction section consists of 6 reactors (3 batch and 3 cascade).
Currently Monsanto manufactures four different types of Aroclors (1242, 1016,
1254 and 1221). For the manufacture of any given product, the chlorinator is
charged with proper quantities of biphenyl and catalyst and heated beyond
the melting point of biphenyl. The flow of vaporized chlorine is then started
and the charge is circulated with a pump. Throughout the chlorination, the
temperature is kept above the melting point of the mixture, but below 150C to
avoid excessive sublimation and plugging of the line discharging the hydrogen
chloride produced by the chlorination. The reaction pressure is maintained near
atmospheric. The degree of chlorination is principally determined by the time
of contact of biphenyl with anhydrous chlorine. The contact time varies fran
12 to 36 hours for the manufacture of different Aroclor types. The degree of
chlorination is measured by the specific gravity of the mixture or the fall
and ring softening point when the product is viscous.
'
The vapors from the chlorinator (HCl containing PCBs) are scrubbed with liquid Aroclor and the gaseous HCl is sent to another plant at the Sauget canplex for purification. The crude product is held at an elevated temperature and blown with dry air for several hours, `after which it.is sent to the raw Aroclor storage tank where a few tenths of 1 percent of line is stirred with the material to react with any remaining hydrogen chloride or ferric chloride. The air from the blcwer tank is scrubbed with water and vented to the atmosphere through a demister.
Tie raw Aroclor is subsequently batch distilled under reduced pressure to remove the color, and the traces of hydrogen chloride and ferric chloride. The methods of purification are different for the different types of end products. .
D$W 330333
STLCOPCB4076977
F ig u re 1A - P re p a ra tio n o f Crude C h lo rin a te d B iphenyls
Monsanto K rurm irich P la n t
2
DC
g 9
STLCOPCB4076978
UJ
Verjar Inc.
Raw Aroclor 1254, 1242 and 1221, each are distilled in stills under reduced
pressure, achieved via steam jet ejectors, the condensate from the still is
the finished product while the bottoms are the Montars which are drurrrned and
sent to incineration.
'
The distillation section for the 1016 product consists of a gas fired
..
retort and a vacuum distillation tower. The latter is used to allcw the separation
of the higher chlorinated, less biodegradable compounds from the relatively lower
chlorinated and more biodegradable ones. The raw Aroclor (42% chlorinated
material) is fed into the reboiler. The vacuum in the tower is maintained at
about 100 mm Hg via steam jet ejectors. The steam is partially condensed
and the condensate is discharged into the plant discharge sump. The first cut
.
from this tower is recycled back to the retort. At a preset overhead temperature
the 1016 product is collected and sent to the product storage. The high boiling
residue from the tower is sent to a subsequent chlorination cycle and the re
sulting raw Aroclor is distilled in a still. The overhead from this still is
the finished product. The bottoms from this tower are the Montars, which are
sent to incineration.
For special orders, in order to increase electrical resistivity, the Aroclors
are stirred, at an elevated temperature, with a few tenths of 1% of well-dried fuller's
earth and then filtered through paper.
All Aroclors are stored at 150F. Steam coils are used on the storage tanks for heating these tanks.
Plant Water Usage
.
On the average, the PCB plant uses a maximum of 388,800 gallons of water and a maximum of 120,000 lbs of steam, daily. Water is used for non-oontact cooling purposes in shell and tube condensers, in a water scrubber, for floor washings, for showers and in eye baths. Steam is used in the steam jet ejectors and for steam tracing purposes. The plant uses municipal water and purchased steam.
The process water from this facility consists of the liquor from their scrubber and the steam condensates which are discharged in one of the two sumps in the manufacturing area.
Additionally, 273,600 gallons of water is used in the incinerator, daily for quenching the hot gases from the fire box. The resulting weak muriatic acid in the quench pot is used in the venturi scrubber and in the packed tower.
DSW 330335
STLCOPCB4076979
Ver/a r Inc.
4.
The type and quantities of water used and discharged at this plant are summarized below. -
Water Balance
.
. Manufacturing Plant
Process Water
in water scrubber
showers, eye bath
misc. floor wash downs
condensate from steam jet ejectors
Non contact cooling water
Condensate from steam tracers
Total
Quantities, GPP
Used 14,400
7,200 7,200
-- 360,000
-- 388,800
Discharged 14,400 ' 7,200 7,200 14,400
360,000 28,800
432,000
Incinerator water used for hot gas quenching water phase from the sump Total
273,600 --
273,600
273,600 14,400
288,000
Raw Wastes
The raw wastes frcm the manufacturing area consist of the liquor from the scrubber, the condensate from the steam jet ejectors, water used for showers and eye baths, miscellaneous floor wash downs and waste oil collected in drip pans and drums. The composition and the quantities of the individual waste stream are not monitored. All waste streams generated in the manufacturing area are directed into the sumps in this area. The waste oil collected in the drip pans are enptied into 55 gallon drums and sent to incineration.
The raw wastes generated in the incinerator consist of the venturi scrubber
liquor and the water phase from the separator sump in the incerator area. The
composition of the combined stream is monitored. However, the composition of
the individual stream is not known. Non-product PCB discharges are shewn in
Figure 3.
OS**0536
STLCOPCB4076980
- v>. t *
- * **?-*. < *
=* ' i _ .
.j r
* "i - ft . 'V^ i >$
-
}
5.
CD X X OX
<X CD
F ig u re 3 - N a n -P ro d u ct PCB D is c h a rg e s a t
M onsanto's Krurnrnrich P la n t
<
DC UJ
Z UJ CD
x
UJ
CQ 3
m
CD
tr
o
3
cr
o
zo
oh
O X "3 UJ
CD
uj
x h
I< cr
CL
K LU "3
2 O
5
UJ
cr <
2 x Ul
O
tr
cd
cr <
u. h- ui
CD o
ocr
3
<
^
u.
CL x tr
X Ul
3 CD
CD
oX
H O Ul X UJ UJ
I--
<
< 5
Ul H CD CD
2 OX O OO X O ZD
u. a
UJ
i-- CD
I-
<
<
hr
X
CD Z
oZ
UJ CO
Ul CD CQ QI3
Z
o
Z
o
X
o
o Z CD
CD Z
X CL
3_ cd 9:
X XQ id
2"
UJ _
CD 2o 2o_ x01 XX z
o
CD CD
X
<
2 O
CQ X
H H -J
h -J
OO
CQ CD
DSW 330337
STLCOPCB4076981
ver/ar Inc.
6.
Waste Water Treatment and Housekeeping
Monsanto reports significant environmental controls at their Krutmirich, Sauget plant. Since 1969, they have invested more than 22 man years of work and millions of dollars in this program. The in-house goals have reduced the PCB discharges into water and air to less than one pound per day, each.
A John Zink designed incinerator was erected at Sauget in 1970 to safely dispose of PCBs. A schematic flow diagram of this operation is given in Figure 2. Aroclor is steam atomized and fed into the fire box. Natural gas is used for combustion and the feed is incinerated at temperatures above 2200F at 5% excess oxygen with a retention time of 2-3 seconds. The gases are quenched with water and the exhausts from the quench pot are passed through a high-energy venturi scrubber, then through a packed column which is irrigated by the weak muriatic acid originating from the quench pot. Exhausts are then vented to atmosphere through a demister. These exhausts as well as the effluent from the incinerator section are monitored.
' In the incineration area, drainage is directed to trenches and piping which flew into a 10,000 gallon underground concrete basin. The water layer frem this basin is pumped continuously, combined with the scrubber liquor, metered, monitored and discharged into the sanitary sewers of the Sauget complex and firm there it is sent to the East St. Louis municipal sewers. The organic phase from the surnp is periodically pumped into waste storage tanks for incineration.
The incineration unit has a rated design capacity of 10 million pounds per year. Hcwever since the start of its operation this unit has achieved a service factor of about 0.6. Monsanto reports that this incinerator can achieve a maximum of 6 million pounds of capacity annually. This unit is plagued with various mechanical problems.
.
Monsanto uses their incinerator to process both their cwn wastes and as a service to other industries. The service charge for incineration is an average of 5C per lb of material.
The incinerator feed is brought into the plant either by truck, in 55 gallon sealed drums, by tank trucks or by rail. The drums are opened, picked-up by a fork lift and emptied into a concrete pit. 'The tank truck carrying the waste liquids
enters the incinerator area and the liquid waste is then pumped from the truck into the pit. The material in this pit is periodically pumped via a vertical centrifugal pump in one of the four 20,000 gallon, each, incin^rator waste feed
tanks.
DSW 330338
STLCOPCB4076982
I
l o in *i
^V aB 4J
^5 'S
rHtr3> >--^ <
HO>(it-j-'il
-EhK' 3
t> Voj
fl-e
aiioonn
a
h
o<
CM
[mH
' ,, \ . f ' y
7.
DSW 330339
STLCOPCB4076983
er/ar Inc.
8
The rail truck is brought into a designated area close to the incinerator
site.. The material from the rail truck is normally pumped into a long term, 500,000
gallon storage tank. The material from this tank is pumped into the incinerator
feed tanks located on the incinerator pad, when required.
Drainage is provided along the rail tracks. These drains empty into the 10,000
gallon sump located under the incinerator pad.
In the manufacturing area, Monsanto has taken a number of significant steps to prevent loss of PCBs to the environment. Drainage is directed to trenches and piping, and then to one of two concrete 3,000-gallon underground settling basins. This injures PCB containment in case of accidental spill or equipment failure. Relief valve lines and atmospheric vents are routed through catch tanks, or are redirected to settling basins.
When small quantities of PCBs are collected in the settling basins of the manufacturing area they are later pumped into 55 gallon drums, and eventually incinerated. The overflow frcm these sumps is -combined with the non-contact cooling water used at the plant, monitored and then discharged into the Sauget complex's sanitary sewer and from there to the East St. Louis municipal system.
PCBs are packed and shipped in galvanized-steel 55 gallon drums, in tank cars or in rail cars. All rail cars are top loaded. In the drum filling area spills are cleaned via rags or floor dry and these materials are drummed and sent to landfill located in the town of Sauget.
In the PCB truck or rail car loading area drainage is directed into a small concrete pit. The material accumulated in this pit is periodically pumped into the basins located in the manufacturing area.
Nitrogen blanketing is provided on storage tanks to eliminate any "breathing" of the tanks and resultant PCB escape.
Mist -eliminaters have been installed in vapor lines to eliminate the possibility of PCBs leaving the manufacturing area through these lines.
Finally, underground sewers have been replaced with above-ground sewers,
and repaired or combined with others, so that the effluent from the department can be
monitored. In addition, this step will prevent any unknown buildup of PCBs in
the sewer systems or any contamination of PCBs into other sewers.
DSW 330340
STLCOPCB4076984
er/ar Inc.
9
A high housekeeping level is maintained in the plant itself. Housekeeping responsibilities which the operators have assumed are as follows:
-- All pumps are checked for leakage on every shift. Drip pans that
collect leaks are emptied into scrap PCB drums.
-- All leaks are reported and documented so that corrections can be
made and settling basins observed.
-- "Floor Dry" is used to absorb any PCBs that have spilled or leaked.
If it becomes necessary to flush PCBs to the settling basin, a
minimum amount of water is used.
.
--Sampling drums and scrap PCB drums are quickly palletized, labeled
and transferred to the incineration area.
Treatment Costs
.
The installed cost of the incinerator system is reported to be $950,000. The annual operation cost of this unit is $600,000 of which $200,000 is for maintenance. This unit employs a crew of five on a 24 hr operating day basis.
Plant Effluents
'
This plant has no point source discharge from their operation. There is a single discharge from the manufacturing operation (the combined stream of process and non-contact cooling water) to the main sewer system of the Sauget complex and their is a second discharge from the incinerator area to the same sewer system. The composition of these streams as reported by Monsanto are as follows:
Effluent from the Manufacturing Operation
Effluent
.
from the
Incineration area
flow rate, gpd pH Alkalinity, mg/1 BOD, 5-day, mg/1 Chemical oxygen, mg/1 TS, mg/1 TDS, mg/1 TSS, mg/1 TVS, mg/1 Ammonia, mg/1
432,000
288,000 0S\N 3303^
STLCOPCB4076985
10
Kjeldahl Nitrogen, mg/1
.
Nitrate AsN, mg/1
Phosphorus Total, mg/1
Color (As P)
Turbidity, mg/1
Total hardness, mg/1
Organic Nitrogen, mg/1
Sulfate, mg/1
Sulfide, mg/1
Chloride, mg/1
Cyanide, yg/1
Fluoride, mg/1 Aluminum - total, yg/1
Boron - total, yg/1 Calcium - total, mg/1
Chromium - total, yg/1
Cobalt, total, yg/1
Copper - total, yg/1
Iron - total, yg/1
Lead - total, yg/1
Magnesium - total, yg/1
Manganese - total, yg/1
Mercury - total, yg/1
Molybdenum - total, yg/1
Nickel - total, yg/1
Potassium - total, mg/1
Silver - total, yg/1
.
Sodium - total, mg/1
Tin - total, yg/1
Titanium - total, yg/1
Zinc - total, yg/1
Oil & Grease, mg/1
Phenols, yg/1
Surfactants, mg/1
Chlorinated hydrocarbons, mg/1 (except pesticides)
PCBs, yg/liter
_ .
,
'
.
.
. ao3A2
qSNN ^
STLCOPCB4076986
11.
Inc.
Treatment Facility for the Sauget Complex Monsanto is in the process of building a solids removal, primary treat
ment plant for the treatment of the sewer effluent at the Sauget complex. . This plant is due to completion in 1976. A secondary treatment plant for this effluent, which will consist of a neutralization operation, is in the planning stage at the present time. This latter project is due for completion in 1978.
..additionally, a regional biological treatment plant is also in the planning and negotiation stage. The completion date of this project is not known. How ever, Monsanto will have access to this treatment facility and will utilize this plant as a tertiary treatment stage for the sewer discharge frcm the Sauget complex.
DSW 330343
STLCOPCB4076987