Document pBYo2yKVJxxDKyBE1rVwKp8dX
ORGANIC CHEMICALS DIVISION
RESEA
MPQRTNO.- P-1592
J08N0.- 2-02-760.01-1348305
TENTATIVE PROCESS ON
MCS 1016 A
*Tf- March 22. 1971
WRITTEN BY - D. R. Cova
ST..L0UIS, MISSOURI
HONS 040801
ORGANIC CHEMICALS DIVISION
Monsanto
ST. LOUIS, MISSOURI
HONS 040802
MONSANTO COMPANY
SAFCTY REVIEW COMMI
ORGANIC CHEMICALS DIVIS10|NAPPROVj
TECHNOLOGY DEPARTMENT
'*Q
FINAL APPROVAL DAT^IAY Q 7 1971
DO NOT REPRODUCE, TRANSFER, STORE OR DESTROY RETURN REPORT TO: ORGANIC RESEARCH DEPARIMENT
TECHNICAL INFORMATION GROUP 1700 SOUTH SECOND STREET
Report No. P-1592
Job No. 2-02-760.01-13A8305
TENTATIVE PROCESS
ON MCS 1016A
Date: March 22, 1971
Written by: D. R. Cova
Work done by: 0. R. Cova J. E. Silver J. L. Bernhardt
HONS 040803
DISTRIBUTION OF
REPORT No. P-1592
1. File
2. Technical Reports Library
3. Extra
4. Extra
5. Extra
6. Circulate to Director of Technology, R & D
Managers/Library
7. J. E. Silver - Res 1
8. D. R. Cova - Res 1
9. W. R. Richards - G. 0.
10. J. Savage - G. 0.
11. R. L. Neary/A. J. Helnze - CED
12. R. H. Munch - Res 2
13. R. M. Kountz - CED
14. R. M. McCutchan - WGK
15. 0. DeGarmo - Res 1
16. Standards Dept. - WGK
17. Standards Dept. - WGK
.T"'
18. Standards Dept. - WGK
19. Patent Dept. - J. E. Maurer
This 'document Is the property of MONSANTO COMPANY. It contains CONFIDENTIAL INFORMATION which must not be re produced, revealed to unauthorized persons or sent out side the Company without proper authorization. The recipient is responsible for its safekeeping and return upon request.
MONS 040804
TABLE OF CONTENTS
Page No.
INTRODUCTION...................................................................................
1
NOMENCLATURE...................................................................................
1
SYNOPSIS OF THE PROCESS.......................................................
2
MATERIAL BALANCE AND FLOW SHEET .....................................
3
PROCESS IN DETAIL.......................................................................
3
FLOW SHEET FOR MCS 1016A DISTILLATION .......................
4
MATERIAL BALANCE FOR MCS 1016A DISTILLATION AREA
5
DISCUSSION OF IMPORTANT VARIABLES ................................
7
A. Aroclor 1142 Fractionation
7
1 . Control
7
2. Cycle Time
8
3. Pressure
8
4. Portion distilled
8
5. Number of plates andreflux ratios
8
6. Column Holdup
9
7. Effect of variationsIn feed composition 9
8. Tail fraction
10
9. Corrosion
10
10. Blending
10
B. Residue Still
1. Semi-continuous operation 2. Pressure and Temperature
10
10 11
MATERIAL SPECIFICATIONS AND PHYSICAL CONSTANTS DATA 11
TOXICITY AND HAZARDS................................................................ 11
POLLUTION CONTROL....................................................................... 11
ENGINEERING DATA....................................................................... 11
ANALYTICAL METHODS..................................................................... 12
APPENDIX
HONS 040805
INTRODUCTION
MCS 1016 or MCS 1016A will replace Aroclor 1 242 in the functional fluids product line for the following reasons. Recent scientific data suggest that non-biodegradable poly chlorinated biphenyls cause considerable ecological damage when dumped into the environment. Although conclusive scientific evidence on all polychlorinated biphenyls has not been developed, public opinion has been aroused. Aroclor 1242 does contain appreciable amounts of slowly biodegradable polychlorinated biphenyls and the use of Aroclor 1242 causes some of this material to be dumped into the environment. From the viewpoints of both ecology and public relations there is an urgent need to produce a more biodegradable substitute for Aroclor 1242. MCS 1016 or MCS 1016A will be the substitute.
MCS 1016 is Aroclor 1242 from which some of the slowly biodegradable components have been removed. Since this product may be less fire resistant than Aroclor 1242, it may be necessary to produce MCS 1016 A, MCS 1016 from which part of the material containing less than 3 chlorines/mol has been removed in order to bring the average chlorine content to a value nearly equal to that of Aroclor 1242. Laboratory evidence indicates that the least biodegradable components in Aroclor 1242 are the higher boiling components. Aroclor 1242 is produced by a straight takeover distillation of Aroclor 1142. By fractionating Aroclor 1142 most of the higher boiling components can be removed. Laboratory evidence confirms that fractionated Aroclor 1142 is more biodegradable than Aroclor 1242. The low-biodegradable residue from this fractionation is used to make Aroclor 1254 and Aroclor 1260 which are unlikely to find their way into the environment.
Fractionation data on Aroclor 1142 was generated by the Process Technology section. This report describes how the present Aroclor 1242 process can be changed to produce MCS 1016A. This report supplements Report No. P-1579 which describes a process for MCS 1016. MCS 1016A differs from MCS 1016 in that a forefraction is also removed from Aroclor 1142 to make MCS 1016A. This is done to raise the average chlorination level of the final product.
NOMENCLATURE
Th Aroclor nomenclature is the standard nomenclature used for Aroclors.
The abbreviation C. B. will be used to refer to chlorinated biphenyls. This abbreviation followed by an interger refers to a chlorinated biphenyl containing that number of chlorine atoms per molecule.
MQNS 040806
2.
SYNOPSIS OF THE PROCESS
The present Aroclor 1242 process is converted to an MCS 1016A process by changing the distillation process steps. Since the other process steps are unchanged, well documented, and current plant practices, they will not be discussed at length.
The process steps required to produce Aroclor 1142 are essentially unchanged. Biphenyl is reacted with chlorine
gas In the presence of a Ferric Chloride (FeC13) catalyst at 140-170C. This is an aromatic substitution reaction and the product is a distribution of biphenyl and C.B. isomers which contain from one to five chlorine atoms per molecule. The following is a schematic representation of the reaction.
\
G>--O + ci2
btphenyl M.W. 154
ch1orine M.W. * 71
n = 0-5
140-170C
fct:
1
chlorinated biphenyl M.W. 154 - 367
nHCL
The reaction product is blown with dry air to remove free MCI gas. The blown reaction product is Aroclor 1142.
The Aroclor 1142 is vacuum distilled through a 30 plate, sieve tray column. The fractionation is carried out in the batch mode. A forefraction comprising 10 to 20% of the charge is distilled off. This fraction Is recycled to one of the chlorination stages. The main fraction Is taken off until a total of 82% of the charge has been distilled. This main fraction Is sent to porocel treatment to make MCS 1016A. The residua (comprising 18% of the charge) is subjected to vacuum, straight takeover distillation. 97-98% of the residue is recovered in this way for further chlorination to make the solid Aroclors. The residue remaining in the straight take over still is incinerated.
The final process step Is unchanged from the Aroclor 1242 process. MCS 1016A Is circulated through a porocel column to remove moisture and Ionic material. The finished product is stored or drummed for sale.
MOWS 040807
3.
MATERIAL BALANCE AND FLOW SHEET
The material balance and flow sheet cover only the distillation area. The remainder of the process Is un changed except for the recycle of forefraction from the distillation to an appropriate chlorination stage.
The material balance is based on a forecut comprising 10% of the still charge. This forefraction can be as high as 20% of the charge depending on the results of MCS 1016A product tests now In progress.
PROCESS IN DETAIL
Except for the distillation steps, the process to pro duce MCS 1016A is essentially the same as the process currently used to produce Aroclor 1242 at W. G. Krummrich and Anniston, Alabama plants. The process steps which re main unchanged are:
1. Chlorination
Biphenyl Is reacted with chlorine gas In the pre sence of a ferric chloride catalyst In four continuous re actors In series. The unreacted biphenyl and C.B.'s pro duced are transferred to the blow tanks for aeration.
The one change in this area Is the recycle of the forefraction from distillation. This forefraction should be fed Into one of the chlorination stages. The appropriate stage should be selected by matching the composition of the feed to that stage with the composition of the forefraction. Since the amount of recycle Is not yet known, neither is its composition. Complete definition of this portion of the process must await a decision on forecut size.
2. Aeration
Dry air Is blown through the biphenyl and C.B.'s to remove free HCL gas. The aerated material, Aroclor 1142, is transferred to the distillation step.
3. Porocel treatment
' The distillate from the distillation step is circulated through a column packed with Porocel to give the finished pro duct.
MONS OA0808
Feme FR/a'av RencLap
RE/ipu e To l/fcwe KATOK FLOW SHEET FOR tfCSIOIt A V ISTlLLATIO/t
MQNS 040809
flATBUlAL BAlAACE FoK HC5I0ISA
Pi*tu.lati0* A ACA
\ Foc*
\ 5-TMMM
^Rollon ~W
Line Fone c a.i MZ5/0/6A ColuH* R. eco VEKEP
Waste
Chak&s
Re*mc Retime Resipcie
Conranht\ -To Still
Lour tOILERi HCSI0I6A fl ich *ou-f*_> 4TaU CatAIMT Ca <> n)t
13.83 loo.oo 21.25
.rr
.19
13.83
100.00
21.2.f .75 .19
It. 25
.75 .H
Tota l
138.89 .19 13.89 /oo. CO 25.19
Tenr./C MO 20 Z6B-ZI0 Ut-Z+O 2 90
zi. 2r 3 oo
.89 250-306
Ff.mffa.KC Tot* US
O
90 0
90
25
o
25
Pahs: 106 Ik. of ft t s / / / A
hons o^oaio
pottecu.-r i5 /o-ji of c-hakoc.
6.
Since these steps are unchanged they will not be described in detail. A detailed description of these steps may be found in the Standard Manufacturing Process for Aroclors in Dept. 27 at Anniston and Dept. 246 at W. G. Krummrfch.
The process steps described here take Aroclor 1142 from the blow tank and produces MCS 1016A which goes to the Porocel column. The following is based on producing 100 lbs. of MCS 1016A for Porocel treatment.
1). Aroclor 1142 Fractionation
138.89 lbs. of Aroclor 1142 from the blow tank and 0.14 lbs. of hydrated lime are charged to the still pot of a 30-plate, sieve tray column. The pressure at the head of the column is reduced to 40 torr, and heat is applied to the reboiler. The column is brought to reflux and is run at total reflux until the head and reboiler temperatures have lined out. Projection from laboratory data indicates that these two temperatures will line out in the ranges of 205-215oC. and 255-265C. for the plant column. Distillate is then taken forward at a reflux ratio of 3/1. This distillate is collected in the forecut receiver until 13.89 lbs. of distillate has been collected. This material is recycled to the chlorinators for conversion to Aroclor 1142. The distillate flow is now diverted to the main fraction receiver. When 43.05 lbs. of main fraction have been collected (at this point, 56.94 lbs. of the charge has been distilled off), the reflux ratio is changed to 5/1. Distillate continues to flow to the main fraction receiver until a total of 100.00 lbs. of main fraction has been collected. At this time, distillation is stopped. The main fraction is sent forward for Porocel treatment. The column residue (25.14 lbs. of material) is transferred to the re sidue still.
2). Residue Still
25.14 pounds of residue from the fractionation column are charged to a straight takeover still. The pressure in the still is reduced to 40 Torr. The still is heated and distillate begins to boil over at 250C. The distillation is stopped when the still temperature reaches 300C. \ Approximately 24.25 pounds of material are boiled over. The di'stillate from this still contains approximately 50* by weight chlorine. This material is recycled for further chlorination to make Aroclor 1254 or Aroclor 1260. The residue (0.89 lbs.) which consists of tars, PeCl3 catalyst and lime is transferred hot to an incinerator.
MONS 040811
7.
DISCUSSION OF IMPORTANT VARIABLES
A. Aroclor 1142 Fractionation
1. Control
There are three important control points-in the fractionation cycle: (1) the end of the forecut. (2) the > change in reflux ratio from 3/1 to 5/1, and (3) the end of the main fraction.
The end of the forecut is signaled when 10 to 20* of the charge has been collected as distillate (the ex act percentage required has not been determined yet). The purpose in removing the forecut is to increase the chlorina tion level of the main fraction. Since this changes slowly with forecut size, a larger error in forecut size can be tolerated. A maximum error in forecut size of + 1* of the charge will be adequate for the plant system.
The change in reflux ratio is to take place when 41* of the charge has been distilled. Here also, a maximum error of + 1* of the charge can be tolerated in changing reflux ratio.
The end of the main fraction is the most important cut point. It determines the concentration of highly chlorinated biphenyls in the product. The entire purpose of this fractiona tion is to reduce this concentration to an acceptable level. The end of the main fraction comes when 82* of the charge has been distilled. The concentration of highly chlorinated bi phenyls in the product is very sensitive to this cut point. It was found experimentally that an error in this cut point of + 1* of the charge causes a 30* change in the concentration of C.B. 5's in the product (i.e., 81, 82 and 83* of the charge distilled would give products containing .28, .40 and .52* C.B. 5's). The error in this cut point should be minimized.
The control points can be determined by material balance if some means is provided for measuring total distillate. Reboiler and head temperatures change rather slowly with percent distilled. Because of the large number of components, there are no "breakpoints" or plateaus in the temperature profile (see Figure 2 in Appendix C). Near the end of the fractionation, the temperature change is less than 1C. for each percent of the charge distilled. Since pressure can also affect tempera ture, it would not appear that temperature would be a suitably accurate means of controlling the end of fractionation.
HONS 040812
8.
2. Cycle Time
High temperatures and long distillation cycle
times can cause trace decompositions in the reboiler which can adversely affect the electrical properties of the
distillate. A laboratory fractionation has shown that a distillation time of 60 hours with a reboiler temperature
range of 260^. to 290C. had no adverse effects on the distillate. Plant distillation times and reboiler tempera tures should not exceed these demonstrated values. CED's proposed design is not expected to exceed these conditions.
3. Pressure
The reboiler temperature is directly related to
the reboiler pressure. In the discussion of "cycle time",
the plant reboiler temperature range was restricted to be
equal to or less than 260C. to 290C. This temperature
range occurs at 147 torr. Therefore, the reboiler pressure
should not exceed 147 torr.
CED's proposed design speci
fies a column head pressure of 40 torr and estimates a re
boiler pressure of 140 torr.
4. Portion distilled
The portion distilled is 82* of the Aroclor 1142 charge. This number is based on projected production of MCS 1016A, Aroclor 1254 and Aroclor 1260. If the quantity of residue produced in the MCS 1016A fractionation exceeds the
need for Aroclor 1254 and Aroclor 1260, it must be incinerated. The cost of incineration makes this undesirable. The portion distilled is set at 82* to secure adequate reduction of higher chlorinated biphenyls and to balance residue production with expected Aroclor 1254 and Aroclor 1260 requirements.
5. Number of plates and reflux ratios
The selection of reflux ratios and number of plates is not based entirely on distillate composition. This circum stance is the result of the following:
a. MCS 1016A Is not Intended to be completely biodegradable but is defined to be more biodegradable than Aroclor 1242.
b. There are no standard methods for measuring blodegradabi 1 ity.
c. There is not enough scientific evidence to single out all of the non-biodegradable components in Aroclor 1242.
MONS 040813
9.
The available laboratory evidence indicates that the highest boiling C.B.'s, C.B.4's and C.B.S's, contained in Aroclor 1242 are the least biodegradable. Laboratory ex periments confirm that fractionated Aroclor 1142 is more biodegradable than Aroclor 1242. This fractionated Aroclor 1142 was produced by batch distilling 82% of an Aroclor 1142 charge through a 25 plate, sieve tray column at reflux ratios of 3/1 and 5/1. This fractionated Aroclor 1142 contained ! 0.39% C.B.5's. This concentration was selected as an approxi mate upper limit for MCS 1016A.
A 30 plate column was selected rather than a 25 plate column. The extra five plates were added because a need may develop to produce fractionated Aroclor 1130 to replace MCS 1016A. Fractionated Aroclor 1130 is more bio degradable than MCS 1016A and an Aroclor 1130 fractionation would produce less residue. Laboratory fractionations In dicate that 30 plates are required to obtain a feasible recovery for this fractionation. A 30 plate column was selected to make the MCS 1016A process adaptable to Aroclor 1130.
The reflux ratios of 3/1 and 5/1 were selected to meet tray hydraulics and product volume requirements as estimated by CED for the column. A laboratory simulation of the proposed fractionation produced MCS 1016A which con tained .41% C.B.S's. This was with a 10% forecut. A larger forecut of 20% would increase the concentration of C.B.5's In the MCS 1016A to about .48%,
6. Column Holdup
The effect of column holdup Is to decrease the separating efficiency of the column. The plant column should have an operating holdup of about 3% of the charge. In a laboratory simulation with a 3% holdup, the product was found to contain .41% C.B.5's. In an approximately similar experi ment where the holdup was reduced to .34% of the charge the concentration of C.B. 5's In the product was .07%.
7. Effect of variations in feed composition
The cut points In the distillation will most likely be controlled by material balance. This means that variations In the composition of the still charge can have a large effect on product composition. Thus, a charge of material having a higher degree of chlorination would give MCS 1016A with a higher concentration of C.B.5's. We do not have quantitative data In this area, and so it is recommended that this be followed closely In the plant, especially during startup.
HONS 040814
10.
Each still charge should be analyzed for the degree of chlorination (by measuring density or refractive index as an indication of the degree of chlorination or by analysis for chlorine). In this way it should be possible to correlate one of these measurements with the concentra tion of C.B. 5's In the product. From this a plan of action can be developed to counteract the effect of charge composition on product composition (as,for example, changing the percent distilled according to the density or refractive index of the charge).
8. Tail Fraction
The process as described makes no provision for taking a tail fraction after the main fraction. It may be advantageous to do so. The tail fraction could be recycled to the still with the next distillation charge. It should be possible in this way to reduce the concentration of C.B.S's in the product (by stopping the main fraction at 78 to 80% of the charge distilled). Also, by continuing to collect tail fraction past 82% distilled it should be possible to reduce the percentage of material going to the residue still. This may be desirable if Aroclor 1254 and Aroclor 1260 requirements are lower than expected.
9. Corrosion
The corrosion status is not expected to be different from the Aroclor 1242 process. No work was done on corrosion.
10. Blending
The composition of the distillate varies during the Aroclor 1142 fractionation. Customers who analyze MCS 1016A by Infrared spectroscopy would be able to detect large difference between the lower and higher boiling portions of the distillate. Therefore, each distillate batch should be thoroughly mixed to insure that any portion of the batch is representative of the entire distillation range.
B. Residue Still
' 1. Semi-continuous operation
The residue still can be operated semi-continuously. Residue from the MCS 1016A fractionation can be fed continuously to the still during the distillation. When the still temperature approaches 300C. the feed is stopped. The other operating condi tion of the distillation remain unchanged.
HONS 040815
11.
2. Pressure and Temperature
The residue fed to the laboratory still was at 25C. In the plant, residue can be fed directly from the fractionation column at 290C. The residue will begin to boll at 165 torr. at this temperature. Therefore, reducing the still pressure to 40 torr. will cause a portion of the > residue to boil over without additional heat input.
The still is heated to an end point of 300C. at 40 torr. The pressure of 40 torr. was chosen to achieve a 97% plus recovery of residue with a maximum still tempera ture of 300,'C. The maximum temperature is set at 300"^. for the same reasons mentioned in discussion of "cycle time" for the fractionation column.
MATERIAL SPECIFICATIONS ANO PHYSICAL CONSTANTS PflTA
Except for MCS 1016A, all material specifications and physical constants data are the same as in the Aroclor 1242 process. Proposed MCS 1016A and the available material specifications and physical constants sheets are presented in Appendix A.
TOXICITY ANO HAZARDS
No change Is expected from the Aroclor 1242 process. Toxicity and safety data are presented in Appendix B.
POLLUTION CONTROL
In addition to the pollution controls In existence for the Aroclor 1242 process, a sump tank is to be installed in the water disposal line for the jet ejector system'for the fractionation column. Any C.B.'s In the water will be collected In this tank. These C.B.'s and the tars from the residue still will be burned in the Aroclor Incinerator.
ENGINEERING DATA
The available engineering data Is presented in Appendix C.
HONS 040816
12.
ANALYTICAL METHODS
Except for GLC analysis of MCS 1016A, the analytical methods are the same as used in the Aroclor 1242 process The standard analytical procedure identifications and a tentative GLC procedure are presented In Appendix D.
ds 3/29/71
Approved by:
D. R. Cova
W. R. Richard
Date
0. DeGarmo
Date
0. R. Savage
Date
MONS 040817
Appendix A Material Specifications and Physical Constants Data 1. Raw material specification a. Diphenyl(Biphenyl) b. Chlorine gas c. Ferric Chloride d. Lime e. Porocel 2. MCS 1016A - Typical Properties 3. Physical Constants Data Aroclor 1142 Biphenyl
HONS 040818
Monsanto
RAW MATERIAL SPECIFICATION
PRODUCTION n. W. Corlew PDOCMADMDNT J, Leyerle
mol wt. 154.20 2/6/69________ IMAAASTBMATlA
82601 PLANT
WGK
DIPHENYL (BIPHENYL) UEINO OCRTI.
46
10/23/70
Anniston Plant
APPROVALS
,CM M. A. Terostra QUALITY CONTROL <Chiml ChmmimO
R. Blowers
U. w. Miller
cV K3
(MIMIC AL FORMULA ---------------------- riMukoTy------------------------------
| 2 x 16 oz, W.M. Bottle*
g[ sh,,i^Br/G
LIMIT*
MAT HOO
UNRESTRICTED INFORMATION
(R) Appearance and Color
Light Yellow Cryst. Solid
10,252
(R) Crystallizing Point (R) H,Q GENERAL INFORMATION
68. 7C. , min. ppm max,
10,298 13,155
Distillation Range:
.
First Drop to
2. 5"C. , max.
10,299
Dry Point
Must include 255*C. within range
This specification is the property of Monsanto Company and is for internal use only.
1
(H) ApmUmp
4 iw itotywl imiwH mlr.
MONS 040819
Monsanto
FINISHED PRODUCT SPECIFICATION
"`""'"J. Mo Hoy
T. W. Dalton
rxitr.......
"" ..... .
CN*4|
MNVfT Chlorine (Snift Ofct)
WOK
mauiT mi 11M7 S/dY
11/69
E. Malone
UIIIHU
...... ""
M. A. Tarpatra
uautv tMraH rakil httmIMf
I9mmr. | 232 Internal
"" "
9MIMK4I. PeeMWbA
Mixture
ML T.
KSISISSHTS
10/66
lajransrxBitna------------------puns it ............ "
100 e. c. Gt. Bur.tt.
Hlwion/Stit.
UMtl
MM1HM
UNRISTRICTID INFORMATION Chlorina (Cl)
fflrw Analvaea Volume
9ygen (O,)
3% It
It
Carbon Dlonida (CO|)
1.5% II
II
Carbon Monoxide (CO)
0.1% II
II
Hydrogen (H)
1.0% II
II
Inert Caaaea {By difference) 8.4% It
It
Moiature (HtO) 6 9td. Condition!
2.4 >t 10" * lba. /ft. (Avorngo)
Direct pipeline tranefere to uaing Dopta.
233, 236, 237, 246
Thia apedflcatlon la for intarnnl uao nt WOK Plant only.
1
(R) Routin'' 1
t, .1 " -.'tht-rs A nalyted by i r flue *1 Only
RAW MATERIAL
Date Approved.....................
For Dept.
--
** / y/t
MGNS 040820
Monsanto
W, C. Krummrich Plant RAW MATERIAL
.tPBCIFICATION
psesucrtON T. W. Dalton J. Leyerle
mol wt. 162.21
UTf O or
33500 PLANT
Ferric Chloride Anhydride
WGK
IUPPIIIN
233
[ Jan* 31j 196* APPROVALS
McKesson fc Robbins
M. A. Terpatra <' < eoNTHOi. <ChM Chmmtai) R. Blowers
CWfcHOU FOWMUIA
Fe Cl,
1 x 8 ox. W.M. Bottle
Hlggerson/Stltea
UNRESTRICTED INFORMATION
Appearance
A eeay Sulfate a Ferroua Salta . Solubility:
10:10 of Water
10:10 of Formula 30 Alcohol
Black powder or Granule a 97.0%, min. 0.05%, max. Trace, max.
Complete to alightly turbid, max. Complete to alightly turbid, max.
J.F.Q. 16-A
22-570 120-570 S-570-1 112-B
HONS 060821
Monsanto
38800
Hydrated
W. <3. Kruiranrich Plant RAW MATERIAL
PLANT
WGK
287, 750, 246
SPECIFICATION
4/7/70
Mississippi Lime Co.
TTOUe?IRTT. ,,W. ,,Da,lt. on
APPROVALS
J, Leverle__________________________________
NCBC AftCM
M. E. Gibb*
QUALITY COMTAOl fCMW CfMaUM)
R. Blowers
CMIMCAL PQRMWVA
Ca (OH),
___________________ 8/13/69_______ lx 16 oz. W.M. Bottle
CMANACTIMIfT'C
UIM*T
Hiqqerson/Stites
MtTHM
Appearance
Aesay (Ca(OH),) Carbonates as (CaCO,) Magnesium Sulfates (as SO,)
Fine white or slightly gray powder, free from lumps or gritty material
92,00%, min. 3, 00%, max. 0.50%, max. 0. 30%, max.
10.188
10.191 10.193 10,192 10,189
Supplier1! certificate of analysis to be sent on day of shipment to: Chief Chemiet, Monsanto Co,, Sauget, Illinois
\
)
(Mi Mrnmtnm Amtjfmtm, Att 9ttmm iwtfyit w--K
MQNS 040822
__________________________
____________
Monsanto
On*AMlC CMtMCALD DIVISION
RAW MAI KRIAL SPECIFICATION
MATERIAL COOK
48289
SLANT
WGK
REGULAR POROCEL
tMINC DIRTS.
246
Porocal Corp. (A Subsid. of ___8/3/TO_______ Mineral 6 Chemicals Phillip Coro.)
APPROVALS
WJigWIB--------------------------------------------------------------------- -----1 RJCARM
. ..........
ROCUAtMONr
J, Layerla___________________________________________
IMmPTUN
OVAUTV CONTROL fCMtf CkoNltf
R. M. Blowers
CMMItAUftMWki
ACTIVATED BAUXITE
UOBMOCOta SMCl Of 9/69
)
MSSOLt COR AMALTAM
blMTa
IISUH OT
MTHH
UNRESTRICTED INFORMATION
(R) Appearance
(R) Mesh Test) Less than 60 meshi 20 to 60 mesh inclusive: Greater than 20 mesh:
(R) Mater
Volatile Natter (at 1000*C. to constant weight)
Free from lumps and foreign material
31, max. 671, min. 30%, max. H, max.
2%, max.
10,692 10,100
V
HONS 040823
HCS-1016A TYPICAL PROPERTIES
COLOR (APHA)
'
CONDITION
SP. OR. 9 25/15.5C
.
ACIDITY (Mg. KOH/g.)
MOISTURE (PPM)
REFRACTIVE INDEX 9 25C
INORGANIC (FREE) CHLORIDES (PPM)
FOUR POINT (C)
DIELECTRIC CONSTANT (1000 CYCLES 9 100C)
RESISTIVITY (500 VDC 9 100C, D.l'* GAP) ' AS OHM-CM X 10
HYDROLYSIS STABILITY (PPM AS CHLORIDES)
MONSANTO STABILITY (PPM AS CHLORIDES)
DISTILLATION RANGE (ASTM D-20, CORRECTED)
10% DISTILLED (BY WT.) C
90% DISTILLED (BY WT.) C DIELECTRIC STRENGTH 9 25C (KV)
FLASH POINT (F)
FIRE POINT (UP TO B.P.)
VISCOSITY 100F (SUS)
FIXED CHLORIDE (%)
(G-E) THERMAL CKEM. CHLORIDES (PPM)
(WESTINGHOUSE) HYDROLIZABLE CHLORINE (PPM)
10 CLEAR . 1.363 0.001 40 1.6210 0.02 -18 4.96
353X10 0.10 0.06
324 342 50 354 NONE 70.6 41.3 0.16 0.26
MONS 040824
PHYSICAL CONSTANTS DATA
O,'
;i v i .OH
fTrchmcnll
o.
f NAME
f nmnl,'
`_____
M I. < kI ' *" ight
/>;' ..
I; i * ; .1 /ffl.min IW... ;r < _ jnm.
Bvilw Tuir.t &..... Pmhip rr.ii-: 4___i
Civ;;ri; Pmnl
I'oi.H ?>; . 'Y"ll ___ ______
5j.f'oiT
_ (>r>/1$. 5c
Sff.idi .1 niti ;
2S/15. 5C
Pound'. fill. :>ri *C
Cm Hi.*-. I M Eipanxion RriuKti *> mil., ilM litu vml' l Spectrum (Kefwme*)____
Vrw^'lv . Vi,, .i-
Surtev. .erision. . v'l.sttiiv in Wniy
'Spuoi'iW m ____ Soli,bully in _ _ _____________________ ^
Ml ft* rpUmstd Pmilwl *P&iwe <J Company' (jl^aJtiiionnt *k<
NOTE: TAii* dmim Bhmuid
PHYSICAL CONSTANTS (cont'd.) PHYSICAL AND CHgllCAL DATA
plphenyl
Specific Gravity: 0.992 at 75C/4C.
The swann chemical company bulletin of 1950 i;ave thermal data on diphenyl.
ylacoelty of Diphenyl (from Anniston Files)
F. "TOT
170 lBO 190 200 220 250 500
550 400 4S0 482
Centlpoi8<
------nryj
1.50Q 1.208 1.114
1.054 0.901
0.752 0.574
0.459 0.574
0.515 0.205
Specific Heat (from Anniston Filaa)
F- B.T.U./lb.
200 500 400 500 600
700
800 900
1000
0.416
0.470 0.547 0.616 0.658 0.679 0.6&6
0.690 0.696
HONS 040826
o
PHYSICAL AND CHEMICAL DATA (cont'd.) Diphenyl (cont'd.) Another record gives the following values for liquid diphenyl;
c Sp. Hoat. cals./gr^-.i 100 0.360 150 O.38O
200 0.412 250 0.460 300 0.518 350 0.575 400 0.610 450 0.625 Vapour CP 0.46o
250tTC.
0.625
o 451JOC. (D- A- Roper, Design 1 Density of Liquid Diphenyl {from Anniston
c. Grams,/cc 75 0.9885 100 0.9695 150 O.9294 200 0.8885 250 0.8470 300 0.8010
0.7510 0.6918 450 0.6180
Heat of vaporization;
' 65.4 g. oal./g. at 258.5C.
o
/> />
HONS 040827
APPENDIX B "Safety and Toxicity Data" taken from The Standard Manufacturing Process for the Manufacture of Aroclors . in Dept. 246 . W. G. Krunmrlch Plant.
MONS 040828
SAFETY & TOXICITY DATA (Cant'd.) CHLORINE (Cl) (Cont'd. ) Fire Hazard: There le no fire hazard under normal conditions, but there la an explosion hazard If ohlorlne Is mixed with a strong reducing agent such a3 hydrogen or hydrocarbons at high temperature. Other Hazarda: This material causes eye, skin, and mucous membrane Irritation Treatment and Antidotes: The patient should be given oxygen lmmedlatei. and treated ror shook". Call a physlolan. Storage and Handling: This material should be stored in a ventilated and cool place away from fire hazards. When handling, wear a gas ma.ik or approved respirator, clothing and rubber or chemical safe goggles. In strong ohlorlne concentrations, wear canister gas masks, Scott air pack, or oxygen breathing apparatus. Shipping: The shipping containers must have a green gas label and non-flammable label on. Ship In steel oars or cylinders.
]
040829
MONS /
SAFETY Ic TOXICITY DATA (Cont'd.)
ATTAPUIflUS EARTH: Toxicity: This.earth la not toxic In general.
Fire Hazard; There is no fire hazard.
Other Kc.::ard8: Attapulgua earth oan create a dust .v.zara similar to other ousts that contain silica.
Treatment and Antidotes: Consult a physician.
Storage and Handling: Attapulsug earth presents nc special storage problem and should be handled by persons wear-inf-, an approved respirator.
Shipping There are no special restrictions on shipping.
HYDROOEN CHLORIDE (HC1)
Toxicity: This material la a gas under normal conditions and is very Foxfc.The M.A.C. Is 5-10 ppm and a concentration of 1500-2000 ppm would be fatal to humane In a few minutes.
Fire Hazard: There Is no fire hazard under normal conditions, but wet gas reacts with some metals to fora hazardous hydrogen.
Other Hazards: This material 1b hazardous to teeth, skin, eyes, and mucous memoranda.
Treatment and Antidotes: Wash profusely with w.-.ter, If invested, eat ch-.lk, magnesium hydroxide, egg whites, and milk, and disc- administer oxygen. Call a physician.
Storage and Handling; This material should be stored In a cool, well ventilated area away from oxidizing agents. This material can be stored In rubber lined, glass, or tantalum vessels. People handling this material should wear suitable clothing like rubber aprons, shoes, and gloves. Also rubber goggles or chemical safe grades and approved pack
or canister gas masks.
Shipping; Shipping containers must have a white warning label and a
non-rlammable label. Ship In appropriate containers such as rail ca,-
or carboy. -
-
CHLORINE (Cla)
Toxicity; This material la a gas under normal concitlone and la very coxic. 'rne M.A.C. la <75 to 2 ppm. A concentration of 1000 ppm wouia be rapidly.fatal. Laaat concentration with dtteetaole odor la 5.5 p?m
HONS 040830
SAFETY & TOXICITY DATA (Cont'd.) DIPHENYL (C6H5C6H5) (Cont'd. ) Treatment, ami Antidotes: wash eyes with water and get the patient to fresh air. Try-lo ioVpatient to vomit, and call a physician. Storage ana Handling: This material oan be stored in steel containers away from rire Hazards ana oxidizing agents. Wear suitable clothes and approved goggles when handling diphenyl. Shipping: Ship in cars or other suitable containers with a red warning label or flammability. LIME Ca(OH)a Toxicity: Lime la not dangerously toxic, and it is regarded as more of a nuisance. This material is a solid or slur: y. Fire Hazard: This material is not flammable. Other Hazards: Lime Is very hazardous to the eyes. It will burn the snln also, and tne dust will affect the muooue memv rant- a. Treatment and Antidotes: Flood eyes and skin with large quantities of water. If lime Is ingested, get patient to vomit and call physician. Storage and Handling: Lime can be stored in :ceel containers, and people should wear protective clothing, respirators, and rubber or chemical safe goggles when handling lime. Shipping: mere are no special restrictions for shipping, but the containers should have a white label, a oaustio warning.
f
1
MONS 040831
o SAFETY & TOXICITY DATA (Cont'd.)
Other Hazards: This material can cause dermatitis, systemic poisoning from the l'umes, and yellow atrophy of the liver. There are skin, mu . jus membranes and eye hazards encountered in handling this material.
Treatment and Antidotes; Call a physician and remove patient from r.-.i's.
Storage ana Handling: Protect the skin, lunge, and eyes by wearing approveu protective clothing, respirator, and goggles. People who handle this material at elevated temperatures should :ave medical supervise.. . and the air should be sampled to insure compliance wltn m.a.C. There .are no special storage restrictions under normal conditions except store ir a ventilated area.
Shipping: There are no special shipping restrictions.
FERRIC CHLORIDE (FeCls)
Toxicity: This material is a solid under normal conditions and la n;.,toxic or nas a rating as low.
O' Fire Hazard: There la no fire hazard under normal conditions, but It will emit toxlo fumes at high temperatures.
Other Hazards: Some people are allergic to Shis material and may de.siop skin raBh, and there Is an eye hazard.
, Treatment and Antidotes: Call a physician.
Storage and Handling; frot : . the Skin with :proves protective clo;.:vi.-.g, avoid the breathing of FeCls duet, wear approved respirator with adequate cartridge, and protect the eyea with'approved goggles. There are no storage regulations.
Shippingi There are no shipping restrictions.
DIPHENYL (CfiHgCgHO
Toxicity: This material is a solid at normal conditions and la medin, toxlb. The M.A.C. of vapor is 2 mg/oublo meter of air. If Ingests' the lethal oose is 2.4 g/Kg of body weight. The fumes are not dang -ously deadly, butp-they are poisonous over a prolonged time .
Fire Hazard: Diphenyl Is very flammable and will bum when exposed iheat or flame or oxidizing materials.
Other Hazards: Diphenyl is rot too oorroelvi, to skin, but It will direct ths'syeiV----------
. MQNS 040832 S
SAFETY fc to:: :Ci- Y DATA (Cont'd.)
Safety Precautions (Cont'd.)
2. Sampling of Crude Aroclor
Toe samples of Aroclor taken during tht nMorinaclon reaction are
hot (170C.). Precaution must be taker c : avoid skin contact or
samples and Inhalation oi Hydrogen Chi. . ; . C: lorlne and Aroclor
vapors.
3. Fires
Fires may result from the Ignition of l: king ;';as, Xylene, Dlph ryl,
rags, paper, wood, etc. Automatic fire t .tin;: s hers and sprln.uc.~s
have been installed to combat fires.
4. Explosions
Explosions may be caused from accumulated pockets of natural gas
or a rapid burning of Diphenyl In a closed container such as a
Chlorlnator. Chlorlnators are equipped with a io" diameter
pressure relief line with a rupture disc made -o burst at 22 psi
In case Diphenyl within the Chlorlnator Jsnltea.
5. Toxlolty
Toxicity does not present a serious problem However, a complete
dally change of clean clothes Is suppl. ,:d to ench person and time
Is allotted at the end of each shift to cake a bath. Instructions
are also Issued to avoid actual akin contact with Biphenyl and
Aroclor as much as possible and to was;. : nci und face before
eating.
6. Miscellaneous
There are many accldent-i that can occu:
may be classified
health and safety hazan s. These acc'a-.a mey result from such
things as broken process lines, acid It.:; , st man leaks, etc.
The worst Inherent hazards are as foils,;.
1. Free Chlorine from ruptured line or major leak. 2. HC1 Oas from ruptured line or major leak. 3. Dropping bottoms from stills. 4. Hot Aroclor < Diphenyl.
AROCLOR
1, Toxicity: This siaterlal Is a liquid under normal conditions and hi3 u medium toxicity range for liquid Ingestion r.nd -v. ,h toxicity for v-.por Inhalation. The maximum allowable concentration (M.A.C.) Is 1 mg, oubJs meter.
Fire Hazard: There la no fire hazard under normal conditions. Ar >clor ixoo WWiis Toluene, Bucyl Aoetete, etc.; mry .`urn and explose i > cr temperaturea when exposed to flames.
MONS 040833
SAFETY & TOXICITY DATA
Safety Equipment The following la a Hat of aafety equipment (peraonal and departmental) required In department 246.
1. Fire extlngulahera: A. Dry Chemloal (5) - Southweat corner Bldg. CR - Main Floor. - West wall at top of stairs of Second Floor.
B. Carbon Dioxide Snow - SouthweBt corner of Bldg. CR, ground level.
2. Chlorine Oaa MaeKb (4) - Southweat corner, second floor - control room, second floor
- East aide, outside control room
- Wall, Southweat comer of sprinkler house, main floor.
5. Scott Air Masks - West of Lean-To
4. Safety Showers (2) - southeast comer of Bldg. CR, ground level.
- Southeast corner of Bldg. CR, 2nd Floor.
5. Pavla vapotester
6. Eye Batha
7. Sprinkler System
Safety precautlone
The folliwlng are safety precautions followed in the operation of department 246.
(1. '
Safety Equipment of Employee Each employee haa tne following safety equipment: (1) Hard hat (2) Safety glasses (3) Ooggles (4) Rubber and canvas glovea (5) Rubber overshoes. Special equipment may be Issued as
neoessary for performing a particular job in a safe manner.
t t
MQNS 040834
Appendix C Engineering Data 1. Vapor pressure equations for biphenyl 2. Bolling Temperature versus pressure curve for
the residue from the MCS 1016 distillation. 3. Reboller Temperature versus Percent Distilled 4. Component material balance for MCS 1016
fractionation column
MQNS 040835
Biphenyl vapor pressure equations:
For temperature
70C. to 254.9"C.
log P - 7.0220 - (T/l'VT) - (245,700/T2)
p pressure In mm. Hg. T temperature In degrees reiv'd
For temperature
250C. to
Log P * 4.76 - 2123.3__ T + 230
p pressure In atmosi i<..es
* Temperature In degrvus centigrade
The vapor pressure equations wer; : -ained *rom
Vapor Pressure of Organic Chemis.
J. !.'-l Jordan,
Interscience Publishers, 1954, pagu 54.
MOMS 040836
(3a,/in P ini'
far
^astdue from rnci Jt
. "V LSUrer . ://onct^ieri
I. I.
I.
I
fn rs i ure ( fa rr j
HONS 040037
Repoiler ~pHF, vep-fufi feicesr OitTiuLer
^ Rt/^fcK i-'iX (/,> 1 T/ /{,
Pi -r Pf'-Lf h: ,, -, ,#4
$?-11 i i bt
O2
2 Co
**-t
H
to 'HAW 1* ll 4* *t
*/ ~0STiLLgb
Component Material Balance The following table Is a cownnent ) 1 a n c e for Aroclor 1142 In the MCS 1016 f; ;ct1ona tlon column. The weights nrr i,,rjeJ on GLC analyses of a laboratory fractijia. i on.
HONS 040839
<*.*** e/?T"
1 PlfHSNYL
z CfcTV\e C.BS.
3 r*T4 C.01
J l
P2,^4Rfl CC.3.821. t,l` C.o. *
7 e
lZ,\r
CC.f.cB. L.t
/
0.0 t 0.1 o oo 4* 0.2 1 0. '.' 0 7.27 0.0^
/0
2,3 C. 0 t 7,7' C.PZ
i1 W: 13
C.C. 3 hS.ZC,t.3 3. 3' C.B. 2.
/7.-97 37 /.I o / 70..3' 30
i
ifSt _j..hI ' CC.B.tZ2.
0,.31 7
!L c.oz
ir 'l.T' c. S
i/V* 2*
2 J, 2 'f .3 Cf..aO 33
7/,?2. 7y fr.rf I. 1 i,,. /./ 2
ll ``.a, 3
4.5 5
12 C. a 3 U C. is' $
o.l /
1if1 (
*; 2 .7
1it7
. \w' c.o.3 f.o H
n C.O. 7
i . . ./ 0,0 Z. .......... 3o..oi 3
c.5 4
. /
J1 333? 3315-
'a 7 Cl3. 7 c.0.4 crr...,ar....77|
V.
\/ ....... *
5,?S
1.5 i 3.0 5
O2 .3o 80
|
337t cj..aV. *'fc.0 3 Jt*Y2 C.&H-
O.7 ? / P.7J
)
*3 '.B. 3
0.0 &
K CA *
i*7 4j*r8o*
o(~C3.SO5 S ;.os
5/ <331
e<.-Oi..Ss (..O.S
S't ts
c'..aR.sy
ft f.5.3
17 C.B.S
07..57 35
0.7 7
.i
.
0.7 0 0,0 2
. 0,0 0.
.... . .. 0.71
0/.7r .3
' . -i
. , i
-.
s
.!0,.0/ o.o
Z/. )
. .
.
( C.O s U,
4 * Pr . .
H..., . 1 1 P.OfS,
.
-iT#*ror** 4s . J =:&J.L *-*.
/ 7.5 :'.L " = t t ' - L_ ...
PcMtne/s a * ,
. _op 8 _ 0,0 2 .
O.Q.q ;' OlOI ;., . o. 1 *f o.o fir .o0..o1 tJ I.fc 7 o,i i 1:31 0,0 ( s0.H5iy 0(2.7 .. 7e>. ,o'7>3 0.05 . Pr.t .0.15 . . ...jPPLL, .i1-o1.13,5".1 . ;-vV_ . JOiO./.l -j^t : 3t( urti.
* , Z5/?r s; tc//oJ"/t. 0c 1
1 0.73 0.."' d
, 0..1i <"3 i*' 5,2 1
77 / C7J..P7r. i3f1 / C.' 7
r..: ^ 0 -
2.0 1
77.-i/ 35 / 7.2/
.
0.4 / ./ 3
'Vr it
')
^ ,<? /
, i ;
3.10 c0.0074
5.0*
/2
'0
: 1
. i3r z /.2 /
!
r, / 2 /.?o
1 i*p-
00 i
; 1I : ' 1 . : 1
HONS 040840
00. OO
; , '
APPENDIX D Analytical Methods 1. Current analytical procedures 2. Tentative GLC procedure
HONS 040041
The following Is a list of analyt1i.nl tests used at W. G. Krummrlch Plant.
Number
10084 10084 10114 10620 10175 12741 10115 11608
11607 12672 11503 12169 10117 11605 10123 10126 10086
Procedure ' or Determining
Color ' IIA) Condit; 1 p Sped i ora/.ty at 25/15.5C. Molstu r ? Refract ve Index at 25C. Inorgairo chloride content Pour point Dielectric constant at 1000 cp .
at tore. Reslsi: /1 ty Hydrolysis stability Monsanto. sta '11ty Sulfate1- err, L>nt Distillation range Dielectric strength at 25 Flash point, fire point Corrosion VIscosity
MONS 040842
Physical Chemistry Method No. 71-11
Job No. 1348522
GAS CHROMATOGRAPHIC DETERMINATION OF PENTA- AND HEXACHLOROBIPHENYLS IN AROCLOR 124 2 AND MCS 1016
PURPOSE OF ANALYSIS
This is a rapid, simplified method to be used to determine the level of high boilers (mainly pentachlorobiphenyls) in MCS 1016 obtained from the fractionation of Aroclor 1142. It is not intended for
general analysis of chlorinated biphenyl mixtures. Physical Chemistry Method No. 70-20 should be used for that purpose.
CHROMATOGRAPHIC CONDITIONS
Instrument: Perkin-Elmer 800, Hewlett-Packard 7624A or Equivalent
Type Detector: Flame Ionization
Column: 50' X 0.02" I.D. FFAP S.C.O.T. (Support-Coated Open Tubular) Capillary (Perkin-Elmer Part No. 008-0804)
Column Temperature: 220C
Detector Block Temperature: 300C Injection Port Temperature: 3ICC
Sample Volume Injected: 0.005 ml Split 25 to 1
Flow Rates
Column Helium: 8 ml/min (7 PSIG) Inlet Splitter: 210 ml/min Auxiliary Helium: 50 ml/min Hydrogen: 50 ml/min Air: 400 ml/min
RETENTION TIMES (UNCORRECTED) OF COMPONENTS SEPARATED (CHROMATOGRAMS ATTACHED)'
Biphenyl, Mono-, Di-, Tri- and Most Tetra-Chlorobiphenyls (1.0 to 5.0 min); High Boilers (Mostly Penta- and Hexa-Chlorobiphenyls)(5.5 to 11.2 min).
CALCULATION TECHNIQUE
Peak area normalization. The lack of pure knowns prevents the accurate
determination of response factors (area correction factors) for the individual components. Therefore, the specification for MCS 1016 is simply based on area percent of total high boilers.
PRECISION '
Reference samples* of MCS 1016 (Drum 2) and Aroclor 1242 (Lot KX 491) were analyzed in duplicate on the two instruments listed using both the Disc chart integrator and an electronic integrator (Infotronics CRS-100
on the Perkin-Elmer 800 chromatograph and Hewlett-Packard 3370A on the Hewlett-Packard 7624A chromatograph). The same column was used in both
instruments. Results reported as Area % High Boilers:
MQNS 040843
MCS 1016 (Drum 2);
Chromatograph
Perkin-Elmer 800 Hewlett-Packard 7624A
Disc Chart
0.30, 0.27 0.30, 0.30
Aroclor 1242 (Lot KK 491):
Perkin Elmer 800 Hewlett-Packard 7624A
5.88, 5.78 6.14, 6.32
Method No. 71-11 Page 2
Method of Integration________________
infotronics CRS-100
Hewlett-Packard J 3370A
0.23, 0.21 -
0.27, 0.28
6.22, 5.94 -
6.63, 6.50
Portions of these samples are available to those Monsanto laboratories that are setting up this method for control of MCS 1016 manufacture.
db Monsanto Company Organic Chemicals Division Applied Sciences Section St. Louis, Missouri 5/71 - G. M. Gasser, E. M. Emery
MONS 0408'*'*
FMe!*-*?/ Vndr $60 MONS 040845
|-( e-w/tf-ft"-
MONS 040846
I00k|0
> r z )(o.oorbil. /vies IOIL 2
i t
! I
iH
i
- tz Ivner $60
j- - - - - -HijK BiUs ----------------
I
V u o w
E 'g
o
d
o
o
o
ri X
ff
in
MONS 040847
r
Heulcft-rkck^ 1CZ.H/\
MONS 040848
S77VRT--------IP 0 * I0 3
0 .0 0 * U A f c i*r IZ>fZ ( U + K k H i )