Document pBLN9oBdZMBBYnq2LBeMnoLjD
Asbestos
By Walter C. McCrone and Ian M. Stewart
' N may 1968, Dr. Irving J. Seli: koff of the Mount Sinai Hos* pital in New York established his position as the Rachel Canon of the industrial hygiene world. A series of New Yorker articles at that time was based largely on Dr. SelikofTs experiences in the study of asbestosis, lung and stomach cancer, mesothelioma, and other causes of death related to ex posure to asbestos. His careful analyses of mortality of industrial worker: in known asbestos fiber contaminated areas are convinc ing arguments that asbestos is one of the most deadly industrial hygiene hazards.
The reputation of large indus trial concerns has not always been good when faced with evidence that their plant environments may be contributing to worker disabil ities, if not death. However, large ly through Dr. SelikofTs effort.
Dr. McCrone is Scientific Adviser and Mr. Stewart it Manater. Electron Optics Croup, McCrone Associates, Inc.
followed up by the FDA, Depart ment of Labor, and other inter ested parties, most responsible companies are now doing their best to minimize, if not eliminate, asbestos as a health hazard.
The microscopist has an im portant role in this program to control asbestos as a contaminant in the air we breathe, the fluids we drink, and the food we eat. He must be able to identify asbestos fibers and quantify their size and number. There are problems be cause there are other fibrous sub stances confusingly similar to as bestos, and there are several dif ferent types of asbestos (Table J), differing in optical properties and composition and possibly in the degree of their hazard to humans.
Analytical methods must be sensitive enough for the identifica tion of single fibers. Of course, only a microscope and a trained microscopist can do this. There are methods, e.g., x-ray diffrac tion and DTA, that identify min ute percentages of asbestos in
Table 1 Composltie'
Serpentine
Asbestos
Amphibolci
CHRYSOTILE
3MgO*2SIO]* 2H,0
ACTINOLJTE
2C*0`4Mg0* FeO*aSIOj*HjO
TREMOLfTE AWTHOPHYLl.ru
2CaO5MgO** 7Mp:-"SIO,-
8SI0,*H,0
'<rO
Specific gravity Crystal system Refractive indices
2.3S-2.5 monoclinic 1.49-1.57
3.03-3.5 monocflnle 1.62-1.66
2.9-3.2 monoellnle 1.60-1.65
2 85-3 1 ort/tornombic
1.60-1.CL
AMOr.lTI
:.-m if-
1-LMoO ntiiOj-Hjf'
7 r. 31.
nmmM flint
1 U. t 7(1
cnociQOt rrc
Nii,0*re|0i*
rOBf.lOj
H,C> 3 0 3 4`j monochnU 1 (,' 1 71
AMI III! ai: i r.i it ii(A lout
13
ASBESTOS continued
^ PLAINTIFF'S I EXHIBIT ,
Table 2 Asbestos type
Chrysolite Amhophylllte Amoslte Croeldollie
Dispersion staining colors for asbestos
Refractive Index liquid
Dispersion alatnlng color
Perallel
Perpendicular
1.560 1.610 1.670 1.700
light blue blue-green red magenta magenta
magenta golden yellow golden yellow blue magenta
small samples, but only the microscopist can hope to identify in dividual fibers. Fortunately, the crystallographic properties of the different types of asbestos are suf ficiently distinct to enable certain identification. If the fibers are thicker than about 0.5 /xm, light microscopy suffices; smaller fibers require the electron microscope.
Identification of the larger fi bers by light microscopy is based on refractive index measurement using a polarizing microscope. The easiest way to apply refrac tive index measurement to asbes tos fiber identification is by use of dispersion staining, an optical staining procedure. This is based on annular or central screening of
the objective aperture in cot with specific refractive inde dia, such as the Cargille ii Under these conditions car of asbestos shows two ch: istic dispersion staining one for the light vjbratio tion parallel, and another dicular. to the fiber len; only in one particular i
*
ASSESTOS commutes
Z PLAINTIFF'S \ EXHIBIT
I //.&/)
; >j
Lfi _ _ _ _ _ _ _ _
Figure 2 Chrysolite fibers filtered from a water supply, 3O.OOOX.
Figure 3 Selected area electron diffraction parte/.' tor a single chrysolite fiber.
A sample of water of known volt.-ns is filtered through the finest-rrembrane filter. A section of filter approximately 2-3 mm* is then placed particle side down on a previously carbon-coated elec tron microscope grid, and the membrane filter is dissolved using acetone in a Soxhlet extractor. The sample grids are examined in our laboratory with a JEM 200 electron microscope, using an ac celerating voltage of 150 kv at a magnification of 17.000X on the M3 range of the instrument. This magnification is chosen to focus the intermediate lens aperture in line with the specimen plane; thus, a SAED pattern of the fiber is ob tained with no other adjustments to the microscope. In this way it is possible to spot check the dif fraction pattern of individual fi bers rapidly (Figures 2 and 3).
The total number of asbestos fibers is related to a definite area of the filter, and hence a definite volume of sample, by counting fi bers over a known number of TEM grid squares (having known areas). The length and width of
each asbestos fiber is recorded. Interpolation from the screen scribed at half-centimeter intervals allows an accuracy of measure ment on the screen of approxi mately +0.05 cm. or about +34 cm. Measurements of the indi vidual fibers are read into a tape recorder; this permits the operator to devote full attention to the screen, precludes duplicate count ing of single fibers, prevents miss ing fibers, and maintains the op erator's dark accommodation.
The recorded data are trans cribed onto punch-tape and com puter processed to give listings of the length, width, and aspect ratio of the fibers, together with a com puted mass of each fiber calcu lated on the basis of density D and dimensions L and W (D X L X W). Density values for the different asbestos types are rven In Table 1. Also presented i' me computer print-out is the num ber of fibers per liter of water, the size distribution of the fibers based on length and width, and the distribution of fibers by aspect ratio. The program automatically
assigns the longest dimension to the fiber length and excludes all fibers with an aspect ratio below three.
This procedure, designed by Jan Stewart of our laboratory, has been applied with excellent suc cess to a number of water samples containing large numbers of amphiboles per liter but very low weight percentages. Most of these samples show no asbestos fibers by light microscopy. It is there fore important to specify the method of analysis when staling analytical results. The same sam ple of talc could be analyzed by different methods with very dif ferent results, c.g.:
1. X-ray diffraction shows no chrysotile or amphiboles.
2. A phase-contrast method (similar to the NIOSH procedure to determine the number of fibers per milliliter of air) shows 1500 fibers greater than 5#*m/m' of sample.
3. The scanning electron mi croscope with energy dispersive x-ray analyzer shows about 10*
AMERICAN LABORATORY : 17
ASBESTOS continued
fibers/liter suspected of being am*
.phibole asbestos. 4 Dispersion staining shows ISO anthophyllite fibers/gram of sample. 5. Transmission electron mi croscopy shows 5X10* antho phyllite fibers/liter of sample.
The AET Scientific Apparatus, Ltd. EMMA-4 (Figure 4) only recently installed in our labora tory will undoubtedly be the ideal instrument for the detection and identification of very fine asbestos fibers. A combination transmis sion electron microscope and electron microprobe analyzer (EMA), it enables the microscopist to see the smallest fiber and to identify it by diffraction pattern and elemental analysis. Although a given sample mounted on a TEM grid can be examined
successively by TEM and EMA,
the advantage of being able to examine many particles in a sam ple with assurance of one-to-one
correspondence of particle size, shape, diffraction partem, and elemental analysis is obvious. We have already applied this instru ment to some asbestos samples with excellent results, and expect it will be the instrument of choice for such samples in our labora
tory. The monitoring of asbestos as
a contaminant in our environment is an excellent example of one important problem solved by microscopy. The importance of choosing the proper analytical tool and having a well-trained op erator is also emphasized bv this application to asbestos detection and identification.
Figura 4 EMMA-4, a combined transmission electron microscope end electron microprobe analyzer.