Document pBKxB4NJD2mqq6pkpqraMvX6

October 1978 417 'r\V. Studies on the Compounds Related to PCB (VI) Determination of Polychlorinated Quaterphenyl (PCQ) in Kanemi Rice Oil Caused the "Yusho" and Investigation on the PCQ Formation (Received January 20, 1978) Hideaki M iy a ta , Yasuyuki M u ra k a m i and Takashi K a sh im o to (Osaka Prefectural Institute of Public Health: 3-69, Nakamichi 1-chome, Higashinari-ku, Osaka) Our earlier study revealed that unknown organochlorinated compounds, which were mainly composed of polychlorinated quaterphenyl (PCQ), were present largely in Kanemi rice oil caused the "Yusho." In this report, in order to determine PCQ in Kanemi rice oil, a simple analytical method for PCQ was established and PCQ standard was prepared. The actual PCQ level in the oil was 490 to 866ppm, equivalent to 0.88~3.46 times more than the actual PCB level found in the oil. Moreover, the chlorine concentration of PCQ in the oil was 207 to 450 ppm by MCDGC. From this result, it was confirmed that PCQ occupied 12~$9% of the unknown in the oil. In addition to clarify the cause why large quantities of PCQ was present in the oil, Kanechlor 400(KC-400), which had been used as the thermotransfer media, was analysed for PCQ. Consequently, it became clear that PCQ had generated at level of 690~ 31,000 ppm in the thermotransfer media. Therefore, it was investigated whether PCQ would be generated thermochemically from PCB. KC-400, Japanese commercial PCB preparation containing 48^ chlorine, was poured in a glass ampoule. After the ampoule was sealed, it was heated under various conditions. Consequently, it was confirmed that PCQ was generated thermochemically from KC-400 by heating KC-400 at high temperature in a glass ampoule. The PCQ level in KC-400 increased by heating KC-400 at higher temperature and during longer period. Moreover, it was clear that the PCQ formation was more accelerated by heating under the presence of stainless steel and water, and consequently the PCQ concentration in heated KC-400 became the maximum level, 47,000 ppm. 1. Introduction Previously, we reported that organochlorinated compounds, which were free from PCB and PCDF, were detected largely in Kanemi rice oil caused the "Yusho" and that the chlorine concentration of them was 287 to 537 ppm, equivalent to 1.1 ~ 4 .1 times more than the chlorine level of PCB in the oil, by neutron activation analysis. 1}2) Moreover, GC-MS analysis revealed that the unknown was mainly composed of polychlorinated quaterphenyls (PCQs).1^ 2) In this paper, in order to determine the actual PCQ concentration in Kanemi rice oil, it was attempted to prepare the PCQ standard for the PCQ determination and to establish a simple analytical method for PCQ in samples. On the other hand, until the present there was only a report that PCQ was generated photochemically from original PCB by irradiating PCB 418 J. Food Hyg. Soc. Vol. 19, No. 5 with UV lamps and sunlight.85 However, the result couldn't be applied to the PCQ formation in the Kanemi rice oil. Therefore, the PCQ formation by heating PCB was investigated. 2. Materials and Methods 2.1 Materials KC-400: It was distributed to our laboratory in 1972 by the Ministry of Health and Welfare. Kanemi rice oils: The oils were manufactured on February 5th, 9th, and 10th in 1968, and their lot no. were 821119079, 15520, and 16793, respectively. KC-400 used as the thermotransfer media: H -l was used for 1958 to 1972 at 180 to 270C at a chemical factory. It was opaque dark brown and high viscus liquid. It also had a irritant order which was different from PCBlike order. The brown substance which was not dissolved with n-hexane was present in it. H-2 was used for ca. 3 years at 200 to 220C at a factory where the rice oil was produced. It was transparent pale brown liquid and had PCBlike order. H-3 was opaque dark brown and high viscus liquid and had PCB-like order. The temperature and period used were not clear. 2.2 Reagents Florisil of 60 to 80 mesh was activated over night at 130C. Silica gel TLC plate was Wakogel FM Plate (20 X20 cm) of Wako Pure Chemical Co. Ltd. Methylene dichloride, ethanol, diethyl ether, n-hexane and anhydrous sodium sulfate were reagent for PCB analysis of Wako Pure Chemical Co. Ltd. 2.3 Methods 1) Preparation o f PCQ standard As shown in Scheme 1, PCQ in H-3 was purified by repeating of Florisil column and silica gel thin layer chromatography, checking by gel permeation chromatography (GPC). One KC-400 used as the thermotransfer medium (0.2 g x 5) Florisil column chromatography (20 g, 1.8 cm i.d.) n-hexane: 130 ml 2% diethyl ether in n-hexane solution: 50 ml 5% diethyl ether in n-hexane solution: 100 ml 1/500 aliquot-- Collect of 5% diethyl ether in n-hexane elutes (79.9mg) I GPC analysis Florisil column chromatography (20 g, 1.8 cm i.d.) n-hexane: 130 ml 2% diethyl ether in n-hexane solution: 50 ml 5% diethyl ether in n-hexane solution: 100 ml 1/500 aliquot-- 6% diethyl ether in /z-hexane elute (37.8 mg) i GPC analysis Silica gel TLC (twelve Wakogel FM Plates, 20 cm x 20 cm) mobile phase: n-hexane Extract Florisil column chlomatography (10 g, 1.5 cm i.d.) n-hexane: 100 ml 5% diethyl ether in n-hexane solution: 100ml 1/500 aliquot-- 5% diethyl ether in n-hexane elute (18.5mg) 1 Florisil column chromatography (20 g, 1.8 cm) GPC analysis n-hexane: 130 ml 2% diethyl ether in n-hexane solution: 50 ml 5% diethyl ether in n-hexane solution: 100ml 1/500 aliquot-- 5% diethyl ether in n-hexane elute II GPC analysis GC, GC-MS, MCD-GC analysis Scheme 1. Procedure for the purification of PCQ in KC-400 used as the thermotransfer medium (H-3) October 1978 Studies on the Compounds Related to PCB (VI) 419 gram of H-3 was dissolved with 25 ml of n- 2) Purification and determination o f PCQ in hexane, and each of 1/5 aliquot was put on a Kanemi rice oil Florisil column (20 g, 1.8 cm i. d.) and eluted Sample was saponified, extracted and con with: successive 130 ml of /z-hexane, 50 ml of centrated according to the method described 2% diethyl ether in /z-hexane and 100 ml of 5% previously.2) Ten concentrated extract was put diethyl ether in /z-hexane solution. The five on a Florisil column (20 g, 1.8 cm i.d.) and third fractions were collected, concentrated and eluted successively with 130 ml of /z-hexane, 50 rechromatographed over a Florisil column (20 g, ml of 2% diethyl ether in /z-hexane and 100 ml 1.8 cm i.d.). The third fraction was concentrated of 5% diethyl ether in /z-hexane solution. The and purified further by silica gel TLC. Sample third fraction was analysed By MCD-GC (for was spotted on twelve silica gel plates and devel the determination of the chlorine content of PCQ) oped with /z-hexane. The portion of UV band and ECD-GC (for the determination of PCQ). corresponding to PCQ in each plate was scraped The determination of PCQ was carried out by off, extracted with benzene, concentrated and comparing the total areas in the gas chromatogram dried. The residure was dissolved with 3 ml of of the PCQ fraction with that of PCQ standard. /z-hexane and chromatographed with successive 100 ml of /z-hexane and 100 ml of 5% diethyl ether in /z-hexane solution on a Florisil column (10 g, 1.5 cm i.d.). The five percentage diethyl ether in /z-hexane fraction was concentrated, placed on a Florisil column (20 g, 1.8 cm i.d.) and rechromatographed with successive 130 ml of /z-hexane, 50 ml on 2% diethyl ether in /z-hexane and 100 ml of 5% diethyl ether in /z-hexane solution. The third fraction (purified PCQ fraction) was concentrated, dried, kept in a constant temperature box at 85C, and weighed once an hour until the weight reached a con stant value. The impurities in the purified PCQ fraction were examined by FID-GC, ECD-GC and GC-MS. GC-MS analysis was carried out on a Shimadzu LKB-9000 B equipped with the computer system. GC-MS condition showed following: Column, l m X 3 m m glass column packed with 2% OV- 210 on Gaschrom Q (100/120 mesh); Column, Injector, Ionsorce and Separator temp., 220, 250, 280 and 290C, respectively; Electron energy, 20eV; Accel, volt., 3 .5 kV; Carrier gas, He (30ml/min); Scanning, once every ten seconds; Scanning range, 300 to 700 m/e. Moreover, the chlorine in the fraction was determined by MCD- GC. MCD-GC condition showed following: Column, 70 cm X2 mm glass column packed with 2% SE-30 on Gaschrom Q (100/120 mesh); Injec tion temp., 240C; Detector temp., 250C; Column temp., programmed from 225 to 250C (20C/min); Carrier gas, N2(35ml/min); Transfer, Reaction and Outlet temp., 650, 840 and 840C, respectively; Range, 50ohm; Reactant gas, 0 2 (lOOml/min); Bias volt., 250mV; Gain, high 360. Fig. 1. Gel permeation chromatograms of Kanemi rice oil eluant from Florisil column with 5% diethyl ether in /z-hexane solution and the PCQ fraction separated from KC-400 used as the thermotransfer medium'(H-3) 420 J. Food Hyg. Soc. Vol. 19, No. 5 The ECD-GC condition was described previously.2) 3) Purification and determination o f PCQ in KC~400s used as the thermotransfer media and in heated KC-400 A tenth gram of sample was dissolved with 3 ml of /z-hexane and chromatographed over a Florisil column (20 g, 1.8 cm i.d.) using to the same method described in (Method-2). The five percentage diethyl ether in /z-hexane fraction was concentrated, spotted on a silica gel plate and developed with /z-hexane. The portion of UV band corresponding to PCQ was scraped off, extracted with benzene and concentrated. The extract was analysed for the determination of PCQ. 4) Heat treatment o f KC-400 KC-400 which had been heated before0 was used in this study. KC-400 (2.6ml) was poured into 8 c m X l . 5 c m i.d. a pyrex glass ampoule. After sealing, it was heated in the electric furnace under various conditions indicated in Table 3. 3. Results and Discussion 3.1 PCQ standard Fig. 1-A showed the GPC chromatogram of KC-400 used as the thermotransfer medium (H-3). Peak Q, first eluted from the column, might be organochlorinated compounds with higher molecular weight than that of PCQ. As shown in Fig. IB, the most of PCB was removed by the first Florisil column-clean up, but the PCQ fraction (5% diethyl ether in /zhexane eluant) was fairly contaminated with PCB. Therefore, the fraction was rechromatographed over a Florisil column, but polar PCB remained in the PCQ fraction (Fig. 1-C). Then, the PCQ fraction was purified by silica gel thin layer chromatography. Figure 2 showed the TLC chromatogram of standards and the PCQ fraction. The lowest UV spot (spot Q) corresponded to the peak Q shown in Fig. 1-A. The portion of UV band corresponding to PCQ was scraped off and extracted with benzene. However, the extract was still contaminated with the large amount of hydrocarbons from the adsorbent of the thin layer. Therefore, the fraction was purified by two more Florisil column chromatophies. As shown : Absorption of UV-254nm PCB PCT PCQ fraction 0 o pcb PCQ a0 Fig. 2. Thin layer chromatogram of PCB (KC-400), PCT (Aroclor 5460) and the PCQ fraction of H-3 after the second Florisil column-clean up TLC plate, Wakogel FM Plate; mobile phase, n-hexane Fig. 3. Total ion current chromatogram (by GCMS with the computer system) of the final PCQ fraction October 1978 Studies on the Compounds Related to PCB (VI) 421 in Fig. 1-D, PCB and the compounds with the higher molecular weight were not shown in the final PCQ fraction, and the weight of the frac tion was 18 mg. However, FID-GC and ECD-GC analysis revealed that the fraction contained 2% as the impurity. Figure 3 showed the total ion current chromatogram of the final PCQ fraction. Figure 4-A, B, C, and D showed the mass 100 c 50 HxCQ 510 HpCQ 544 _ 1 1_1(HpCQ-70 )CQ--70 1.HxPQ-70 474 1 440 lU i iiiAiiii1iiiii ii. OCQ 578 NCQ ft, 612i . ________ 400 500 VIIG Fig. 4. Mass spectra of scanning No. 10, 45, 120 and 230 as shown in Fig. 3 A, B, C and D showed mass spectrum of scanning No. 10, 45, 120 and 230, respectively. PeCQ, HxCQ, HpCQ, OCQ, NCQ and DCQ showed penta-, hexa-, hepta-, octa-, nona- and deca-chloeinated quaterphenyl, respectively. 422 J. Food Hyg. Soc. Vol. 19, No. 5 Fig. 5. Possible stracture for M+(406), M+(440) and M+(474) in Fig. 4 A and B n--3~5 spectra of scanning No. 10, 45, 120, and 230, respectively, in Fig. 3. The fragments of PCQ as well as PCB and PCT showed the strong peak at the molecular ion (M+) and minor peaks at (M+-70), a fragment eliminated of double chlorine atoms from (M+). Figure 4A showed that penta- to hepta-chlorinated quaterphenyl were persent in the scanning No. 10. It was supposed that M+(406), M+(440) and M+(474) in Fig. 4-A and B might be cyclic structures of the type depicted in Fig. 5. Figure 4 also showed that the ratio of the higher chlorinated PCQ increased with increasing of scanning number. GC-MS analysis became clear that the final PCQ fraction contained bits of unknown com pounds but that the fraction mainly composed of penta- to deca-chlorinated quaterphenyls. Moreover, MCD-GC revealed that the chlorine content of the PCQ fraction was 45.5%. The PCQ fraction was used as PCQ standard for the determination of PCQ in samples by ECD-GC. 3. 2 The PCQ level in Kanemi rice oil caused the "Yusho" As shown in Fig. 1-E, M-hexane extract from saponified Kanemi rice oil which was manu factured on February 10th in 1968 contained large quantities of non-chlorinated hydrocarbones and PCB. The hydrocarbones and the most amount of PCB were eliminated from the extract by Florisil column-clean up. As shown in Fig. 1-F, the PCQ fraction con tained unknown materials which were appeared to be chlorinated compounds with the higher molecular weight than PCQ, but the unknown didn't disturb the PCQ determination by ECDGC and MCD-GC analysis because they eluted later than PCQ from GC-column (2% OV-210 on Gaschrom Q). As shown in Table 1, the chlorine concentra tion of PCQ in the oil was 207 to 450 ppm. The values were equivalent to 12~%9% of organochlorine compounds, which were free from PCB and PCDF, in the oil reported previously.v >2) It was supposed that 1 1 ^ 2 8 ^ of organo chlorine compounds might attribute to unknown materials. The actual PCQ level in the oil also was determined by ECD-GC. As shown in Table 1, the PCQ level in the oil was 490 to 866 ppm, equivalent to 0.88^3.46 times more than the actual PCB level in the oil. It had been considered that all the chlorine in Kanemi rice oil was derived from PCB, and consequently the PCB concentration was calcu lated from the total chloride level in the oil in 1969 to 1970.8)>9) However, this study revealed that the estimated PCB concentration was the level which contained Table 1. The Chlorine Concentration of PCQ, PCB and PCDF in Kanemi Rice Oils Caused the "Yusho" Concentration of chlorine (ppm) Production date Original sample Hexane extract50 OC>1)<2) PCQ PCBC) 6)'6) PCDF5)'6> PCQ/PCB PCDF/ PCB (sis) (sis) Feb. 5th, 1968 Feb. 9th, 1968 Feb. 10th, 1968 Feb. 21st, 1968 1,485 554 446 11 997 443 462 13 537 450(866) 500(983) 3.98(7.40) 287 207(490) 80(151) 0.95(1.90) 343 248(536) 83(155) 1.15(2.25) 0.88 0.008 3.25 0.013 3.46 0.015 a> Hexane extract from the saponified sample b) Organochlorinated compounds in the hexane extracts from saponified oils that were not PCB nor PCDF c) The values were calculated from the concentration of PCB with the method of the author et al.7) The figures in parenthesis show the concentration of each compound. October 1978 Studies on the Compounds Related to PCB (VI) 423 Table 2. The Concentration of PCQ and PCDF in KC-400s Used as the Thermotransfer Media Sample Used temp. (C) Used period (year) Concentration of PCQ (ppm) Concentration of PCDF (ppm) H-l 180-270 H-2 200-220 H-3 not clear 14 ca. 3 not clear 31,000 690 28,000 510 277 20 PCB, PCQ, PCDF and bits of unknown organochlorinated compounds. It also became clear that the actual PCB level in the oil was barely as 1/3 to 1/7 times as the estimated PCB level and that the PCQ concentration in the oil was 0.88 to 3.46 times more than the actual PCB level. 3 .3 The PCQ formation It was considered that all organochlorinated compounds in Kanemi rice oil were derived from KC-400 used as the thermotransfer medium, which had leaked out into Kanemi rice oil in the deodorized tank. Therefore, KC-400s which had been used as the thermotransfer media were analysed for PCQ. As shown in Table 2, PCQ was detected in all thermotransfer media, and the PCQ level in them was 690 to 31,000 ppm. It was supposed that PCQ m ight. generate from KC-400 during the period when KC-400 was used as the thermotransfer media because PCQ wasn't detected in the commercial KC-400 preparation. In regard to the PCQ formation, there was only a report which PCQ generated photochemically from original PCB by irradiating PCB with UV lamps or sunlight.8) Therefore, it was investigated whether PCQ would generate thermo- Table 3. The Concentration of PCQ and PCDF in Heated KC-400 Heating temp. (C) Heating period (day) Additive Concentration of PCQ (ppm) Concentration of PCDF (ppm)4) Room temp. 180 250 300 // // rr n 360 // rt 300 // 360 // // // // rr rr rf 0 5 5 5 6 10 15 30 2 10 20 3 5 2 5 10 20 2 20 2 20 S a) s s s s s Wb> w S-fW s-pw 0 450 710 2,000 5,700 4,000 3,300 11,000 7,400 7,300 14,000 3,500 1,800 13,000 14,000 25,000 23,000 20,000 37,000 3,800 47,000 33 41 40 35 34 41 84 94 65 55 46 188 182 205 77 223 212 101 71 a) Stainless steel b> Water 424 J. Food Hyg. Soc. Vol. 19, No. 5 Fig. 6. Gas chromatograms of PCQ in KC-400 used as the thermotransfer medium (H-3), Kanemi rice oil and heated KC-400s chemically from PCB by heating KC-400 in a glass ampoule. As shown in Table 3, it was confirmed that PCQ generated from original KC-400 when KC400 was heated at high temperature in a glass ampoule. It also became clear that the PCQ level in KC-400 increased by heating at higher temperature and during longer period. Moreover, the PCQ level increased when KC400 was heated under the addition of stainless steel. It was supposed that stainless steel might act catalytically on the PCQ formation. The PCQ level also increased by heating under the addition of water. Perhaps, water increased the pressure in a ampoule, and consequently the PCQ formation might be accelerated. Therefore, when KC-400 was heated for 20 days at 360C under the addition of stainless steel and water, the PCQ concentration became the maximum level, 47,000 ppm. In addition, as shown in Fig. 6, the gas chromatogram of PCQ in heated KC-400 was more or less different according to the heating condition, especially the additive, i.e., the PCQ composition varried according to the heating condition. When KC-400 was heated under additives, the ratio of less chlorinated quaterphenyl increased in comparison with PCQ in KC-400 heated only (Fig. 6). The gas chromatogram of PCQ in Kanemi rice oil was similar to that of PCQ in KC-400 heated only, and also the gas chromatogram of the PCQ standard resembled that of PCQ in KC-400 heated under the addition of stainless steel and water (Fig. 6). On the other hand, it wasn't correlative between the PCQ and PCDF concentration in the thermotransfer media and in heated KC-400 as shown in Table 2 and 3. This result sug gested that the mechanism for the PCQ forma tion was different from that of the PCDF formation. From the results described above, it became clear that PCQ generated from original KC-400 during the period when KC-400 was used as the thermotransfer media. However, the ratios of PCQ/PCB and PCDF/ PCB in the thermotransfer media were fairly lower than those of Kanemi rice oil. The difference might be explained as follows: After KC-400 which was used as the thermotransfer medium leaked out into Kanemi rice oil in the deodorization tank, the ratios of PCQ/PCB and PCDF/PCB in the oil might become extraordi narily high by deodorizing. The authors are currently working to identify additional unknown organochlorinated com pounds in Kanemi rice oil and the thermo transfer media, and also to resolve the high ratios of PCQ/PCB and PCDF/PCB in the oil. References 1) Miyata, H., Kashimoto, T., Kunita, N.: J. Food Hyg. Soc. Japan, 19, 126 (1978). 2) Miyata, H., Kashimoto, T., Kunita, N.: ibid., 19, 364 (1978). 3) Hutzinger, O., Jamieson, W. D., Safe, S., MacNeil, D., Zikto, V.: "The Chemistry of PCBs," p. 121 (1974), CRC Press, Ohio. 4) Miyata, H., Kashimoto, T.: J. Food Hyg. Soc. Japan, 19, 78 (1978). October 1978 Studies on the Compounds Related to PCB (VI) 425 5) Miyata, H., Kashimoto, T., Kunita, N.: ibid., 18, 260 (1977). 6) Miyata, H., Watanabe, I., Kashimoto, T., Kunita, N.: Osaka Prefectural Institute of Public Health, ED. of Food Sanitation, 8, 87 (1977). 7) Ugawa, M., Nakamura, A., Kashimoto, T.: J. Food Hyg. Soc. Japan, 14, 415 (1973). 8) Tukamoto, H. et al.: Fukuoka Acta Med., 60, 496 (1969). 9) Special report on the prevention, diagnosis and treatment for the "Yusho," Science and Technology Agency, p. 19 (1970).