Document pB8wgDpE23kd1K5MNgrbVXLva

Monsanto FROM I NAME ft LOCATION I Doris May - St. Louis Org. R&D Library - 1700 So. 2nd St. DATE September 17, 1970 cc . subject TOXICITY AND HAZARDS, POLLUTION TO : Mr. E. P. Wheeler GENERAL OFFICES - A-2-S As you requested, attached are the following: _ Physical Constants (New) XX Toxicity & Hazards ______ Material Specifications (including raw materials and finished goods) Reference: Report Type: Tentative Process Title: Tent. Process for MCS 104l (Pydraul Job No.: 1113115 Report No.: P-1577 Date: August 31, 1970 Author( s) : P. D. Fowlkes . dm Att. Doris May IN- tO REV (I 65 DSW 586255 STLCOPCB4091589 Aroclor 1242 has been used in Pydraul fluids for years. Animal testing indicates a very low order of acute and oral . toxicity for Aroclor 5432 and Sant.icizer 711. (NOTE: Current specific toxicity information is being obtained from the Medical Department on these materials and it is suggested these be Included the Appendix of this report.) in General Precautions include the following: 1. Goggles should be worn where splashing or spillage may occur. 2. Any material in contact with the skin should be removed by washing with soap and water. 3* Prolonged or repeated exposure to the skin may cause irritation due to removal of skin oils with resulting dryness and chapping. 4. Material may be irritating to sensitive skin areas and eyes. In case of contact with eye tissue, flush copiously with water and then get medical attention. 5. In case of internal ingestion, get immediate medical attention. 6. Avoid inhaling volatlon material or mists. POLLUTION CONTROL No waste by-products are generated by this process. J.-ec filtering material, flushings from the system during clean ing, s.s well as any spoiled product should be disposed of as dictated by local regulations. Every effort must be made to prevent Aroclor 1242 from being mixed with water and drained into the sewer. Non-aqueous solvents should be used to clean the blending tanks and equipment. A suggested fire resistant solvent would be tri chloroethylene. waste liquids containing polychlorinated biphenyl may be sent to the Supervisor, Dept. 246, W. G. Krummrich Plant for disposal. Vapor generation should be reduced by limiting the hearing of PCB to the lowest required temperature for the process. Solids containing PCB must be disposed of at the toxic lar-fill. Burning of these materials must be avoided. TOXICITY AND HAZARDS No musual toxicity 'or hazards are expected with the raw . trials or finished blend. The process is a simple olending procedure and no hazardous reactions should occur between the various components. ~~ ... DSW 586256 STLCOPCB4091590