36 Am. Soc. of Heat.-Vent. Engineers Guide, 1922
This broad endorsement gives the requirements a reputation for correctness which
has not been accorded to any similar set of specifications hitherto prepared. It is,
therefore, hoped the ordinance may receive generous public approval, and become a
construction standard in cities and towns throughout the country. We urge its
adoption.
E. T. Cairns, Chairman,
R. C. Christopher,
!'. W. Day,
.
Committee on Construction John W. Emery,
of Buildings, National Board Chas. H. Hahn,
of Fire Underwriters
J. A. Kelsey,
A. W. Perry,
E. G. Pieper,
J.'M. Wennstrom.
The ordinance was drafted for the' Committee by its Consulting Engineer, to whom correspondence in reference to, same should be sent.
Address: Ira H. Woolson, Consulting; Engineer, National Board of Fire Under writers, 76 William Street, New York City.*
AN ordinance:
Providing Minimum Requirements for Proper and Safe* Construction of Chimneys, Flues and Fireplaces in the ....................... .... of..............;................. :
scope of the ordinance
This ordinance docs not apply to chimneys for high pressure boilers, furnaces used in manufacture, or for other heating appliances where high temperatures are maintained ; but. shall apply to all other chimneys which form a part of a building construction.
Section 1. Chimney Construction
1. The walls of all chimneys to which this ordinance applies, whether
the fuel used be wood, coal, gas or oil, shall be built of brick, concrete,
stone, or hollow tile, of such thickness and construction as is hereafter
specified, but this shall not preclude the use of a metal smoke-stack when
located inside of a vent shaft having walls not less than 8 in. thick, and
having an air space between the walls and stack on all sides.
2. Brick chimneys shall be built of solid brick, or may be built of
perforated radial brick manufactured for the purpose and adapted to
withstand high temperatures, but no other hollow brick shall be used.
3. The walls of brick chimneys shall be not less than
in. thick
(width of a standard size brick), and shall be lined with fire clay flue
lining.
4. Flue lining may be omitted in brick chimneys for private dwellings
provided the walls of the chimneys are not less than 8 in. thiek, and that
the inner course shall be a'refractory clay brick having a softening point
of at least 1923 deg. fahr. (Seger cone 05). See Appendix 1 and 2.
5. Perforated radial brick chimneys may be unlined, provided the
brick shall have a softening point of not less than 1994 deg. fahr. (Seger
cone 03), and shall be not less than V/2 in. in radial thickness, except that
when such chimney is located inside a vent shaft having walls not less
than 8 in. thick, the thickness of the chimney wall may be determined by
engineering design. The brick shall be shaped to the circular and radial
lines of the various sections of the shaft so as to form even joints.
Am. Soc. of Heat.-Vent. Engineers Guide, 1922
37
Elevation and section of an interior independent chimney showing recommended construction. Extra flues can be added as desired.