Document p2Z9ZyyX39v8O8VkqENq9w0Yw

February 19,1992 Dow U.S.A The Dow Chemical Company PO Box 150 Plaauemine Louisiana 70765-0150 Daniel Cortez Petrin Building 4106 cc: Rodney Bordelon Methanes Building 4601 Asbestos Monitoring Enclosed are sample results for potential exposure to asbestos. The OSHA 8-hour permissible exposure limit for asbestos is 0.2 f/cc >5 microns and the 30-minute short term exposure limit is 1 f/cc >5 microns. The results displayed are based on sampling duration. The data sheet shows the results of exposure using two methods, the Limit of Detection (LOD) and the Limit of Quantitation (LOQ). Included on the data sheet is an explanation of the method Limit of Quantitation. Thank you, - CaJ*-Q Darlene S. Creel Industrial Hygiene Ext. 6181 Building 3502-E Attachment dsc PRODUCED FOR THE ASBESTOS DATABASE DATE: MASTER No. __________ I _____ DO A 114769 CONFIDENTIAL ASBESTOS MONITORING DATA RESULTS: *LOD LOQ 8-HR. TWA LIMIT-0.20 FIB/CC 30-MINUTE LIMIT = 1.0 FIB/CC LIMIT OF DETECTION = 7 FIB/MM2 LIMIT OF QUANTITATION = 100 FIB/MM2 DATE SAMPLE* PERSONNEL DESCRIPTION DUR(MIN) VQUL) 2/1/92 13795 *439-31 -5889 Insulator: Wet method used while removing asbestos from 1 " and 2" "Out of Service" steam lines 30 75 2/1/92 13896 *433-19-6528 Insulator: Wet method used while removing 25* of floor tile and adhesive 30 74 2/1/92 13897 *433-23-2653 Insulator: Wet method used white removing asbestos from 1" and 2" "Out of Service" steam pipes 30 77 * The proper protective clothing was worn during the job. North 7700 Respirator with HEPA filters were worn during the job. ** LOD FIB/CC 0.05 <0.01 0.2 ***LOQ FIB/CC <0.51 <0.52 <0.50 Note: The Limit of Quantitation has been defined as 100 Fibers/MM2 using the minimum fiber loading criteria specified. In the NIOSH analytical method 7400, the stated range of the method is 100 to 1300 Fibers/MM2 filter area. Although samples below this range can be analyzed, the method has not been validated below 100 Fibers/MM2. However, die NIOSH method 7400 also establishes the estimated Limit of Detection as 7 Fibers/MM2 (Reference OSHA Std. 1910.1001, Appendix B). Based on this information, we will establish 100 Fibers/MM2 filter area as our Limit of Quantitation and 7 Fibers/MM2 filter area as our Limit of Detection (which is more representative of the actual fibers present) for asbestos monitoring. We will report both Limit of Quantitation and Limit of Detection. If only Limit of Quantitation were expressed, the minimum reportable result would calculate to be 0.04 Fibers per cc for an 8-hr. Time weighted average sample at a flow rate of 2 liters per minute and 0.6 fibers per cc for a 30 minute time weighted average short term sample at a flow rate of 2 liters per minute. 1147/0 DO *1 t LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD SAMPLE N2 1379 PLANT/DEPT. MONITORING FOR: DATE^--/OTHER CHEMICALS PRESENT:. SAMPLE COLLECTION MEDIA: BADGE NO.____ TYPE. TEMP/HUMIDITY: (REQUIRED FOR BADGES). ?/7PUMP SERIAL NO. CALIBRATION DEVICE: o-bObblemeter OTHER________ ROTAMETER CHARCOAL TUBE SIZE_________________ '''FILTER CASSETTE SIZE X ~7* SILICA TUBE SIZE__________________ DRAGERTUBE TYPE_________________ OTHER __________________________________ PUMP FLOW RATE CALIBRATION: BEGIN: \.2 5~2 St 2.2 ^30 3.2. S'7.1 BEGINNING FLOW RATE AVG. UTJO 0" CC/MIN L/MIN SHIFT: 0*lfHR. 12 HR. S^PERSONNEL SAMPLE AREA SAMPLE ENDING: 1. O^Tull SHIFT TWA a STEl/TASK EMPLOYEE NAME L(/ffCrU?C*Si~d/ 2.2JLZJL 3.2 U 7% ENDING FLOW RATE AVG. U`7 9 _ O'tC/MIN L/MIN EMPLOYEE I.D.# Cj 27 --J JOB CLASSIFICATION -L IH JOB CODE #___________ t CONTRACTOR COMPANY____ SAMPLE AVERAGE FLOW RATE TIME STARTED. J?Qg. TIME STOPPED. TOT. RUNNING TIMEIMIN) 1& 2 tray, RESPIRATOR USED? &<ES NO RESPIRATOR MODEL / CANISTER TYPE O MOUTH-BIT DUST ILF-F; 7 SAMPLE VOLUME (AVG FLOW X RUN TIME) ""IST FULL-FACE /UR-LINE SCBA DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING ' )rt 7*4 ' oS- 2. '----Tf/*e--.* HO A 114771 C. ONF J DFNT T Al LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD SAMPLE NS 13896 PLANT/DEPT. TneZZ* MONITORING FOR: PATE 2-/~9^.. OTHER CHEMICALS PRESENT:. SAMPLE COLLECTION MEDIA: BADGE NO_____ TYPE TEMP/HUMIDITY: (REQUIRED FOR BADGES). CHARCOAL TUBE SIZE_________________ ^FILTER CASSETTE SIZE 2- *7 SILICA TUBE SIZE__________ DRAGERTUBE TYPE_________ OTHER _________________________ SHIFT: O^HR. 12 HR. O^pTrSONNEL SAMPLE AREA SAMPLE FULL SHIFT TWA STEl/TASK EMPLOYEE NAME / SUi/0% EMPLOYEE I.P.* JOB CLASSIFICATION. IH JOB CODE# CONTRACTOR COMPANY. i/4 V RESPIRATOR USED? 3-fs O NO RESPIRATOR MODEL / CANISTER TYPE O MOUTH-BIT DUST O FULL-FACE AIR-LINE DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING PUMP SERIAL NO.. 51U CALIBRATION DEVICE: OSdBBLEMETER O OTHER________ ROTAMETER PUMP FLOW RATE CALIBRATION: BEGIN: \ 2 2.USL33-g^a.y..-- / BEGINNING FLOW RATE AVGCC/MIN O L/MIN ENDINGz:!...aATH.i%/a4-i-_--_-_--_-_--_--_- 2-^J/777 3. ENDING FLOW RATE AVG. JU/ffX ''CC/MIN l/MIN SAMPLE AVERAGE FLOW RATE ^ TIME STARTED /% TIME STOPPED *7/^/^ TOT. RUNNING TIME(MIN). AMPLE VOLUME (AVG FLOW X RUN TIME). 2S' * Y -ryS. / ____________________________ ANALYTICAL REPORT REFERENCE# / ANALYTICAL RESULTS: Wq ^ Uku* Vtlukt> <3a&- * RESTRICTED FOR USE WITHIN DOW ONLY * LOO VP124 /0.53U i-09 FORM FILLED IN BY, _ DO A 1147 CO Mi" I DON'T T II LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD N2sample 13897 PLANT/DEPT. MONITORING FOR: PATE -/~fZL____ OTHER CHEMICALS PRESENT: _ SAMPLE COLLECTION MEDIA: BADGE NO. TYPE. TEMP/HUMIDITY: (REQUIRED FOR BADGES). CHARCOAL TUBE SIZE_________________ "FILTER CASSETTE SIZE ?*- SILICA TUBE SIZE_________________ DRAGERTUBE TYPE_________________ OTHER __________________________________ SHIFT: S^HR. 12 HR. ^PERSONNEL SAMPLE AREA SAMPLE FULL SHIFT TWA STEl/TASK EMPLOYEE NAME. EMPLOYEE I.D.# JOB CLASSIFICATION. IH JOB CODE #. CONTRACTOR COMPANY. RESPIRATOR USED? O^ES^ ONO. *2^-----------------------/ RESPIRATOR MODEL / CANISTER TYPE MOUTH-BIT DUST 1/AUA&. x'rfALP?ACf7 O FULL-FACE AIR LINE SCBA DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING PUMP SERIAL NO.. Q23J9./ . CALIBRATION DEVICEE: (<*UBBLEMETER OTHER________ ROTAMETER PUMP FLOW RATE CALIBRATION: BEGIN: 1 z-rrs' 3. -Z?*/9 BEGINNING FLOW RATE AVG.3.5V2L ENDING: 1.2 T~7`7 2.3f7<r 3 ENDING FLOW RATE AVG..? T ft fj 'a^CC/MIN - ' CVtc/MIN L/MIN L/MIN SAMPLE AVERAGE FLOW RATE TIME STARTED TIME STOPPED l'F7 0 TOT. RUNNING TIMEfMINV 7 C> SAMPLE VOLUME (AVG FLOW X RUN TIME). 11 ANALYTICAL REPORT REFERENCE # ANALYTICAL RESULTS: LtliicJI- PouuvJL * RESTRICTED FOR USE WITHIN DOW ONLY * VP-124 <0.so FORM FILLED IN BY:______ HO A 11477 conftdfntta