Document p2LrLZoEkRQeEqr0akvoRYgBa
nsantc
Reference Number h'J P (02.^-T
Security Class
A
Type
_ Review. Report
TITLE:
Biodegradability of Aroclors 1242 and 1016
AUTHORS: R.A. Lidgett
H.A. Vodden
P.E. Gilbert
J03 NO: 660 10 122 13 REPORT NO:
2
OATE: I3.9.7I
ABSTRACT
The degradation of Aroclors 1242 and 1016 has been studied using two biphenyl degrading organisms C2 and C3 for periods up to 100 days. Results indicate good biodegradability for all components of Aroclor 1016.
Issuing Authority
Distribution
Information Centre (4) J.W. Barrett, London C.G. Wickham, London R.A. Baxter H.A. Vodden R.A. Lidgett J .II. Ma inprize
W.B. Papageorge, St. Louis R.E. Keiler, St. Louis E.S. Tucker, St. Louis E. Emery, St Louis
0007267
COMPANY CONFIDENTIAL
tr>i:
** ft*
*nt* .tn'1
*s
*ls >.!* .**:pirvn. H
cc.rv.*!
-n
U- m-p'khU.
iLhJ *,% tii
ft r-*inuts i*t bu.t OulL. JO ;*`L Company wtUuwl i"
,:r\*rr* tN
C*r.tic ttSM*n tcqu'-M.
(fT>EPOSmON I EXHIBIT
f Papaqeorqe I 63
WATER PCB-00055557
SUMMARY OF RESULTS
1. Id the presence of biphenyl, Aroclors 1242 and 1016
are degraded by both. C2 and CJ organisms. After 100
days Aroclor 1016 residues are less than 5 the
original concentration with either organism. Aroclor'
1242 is degraded to a lesser extent, there being approx
imately
remaining witfc the C2 organism and 15-
20with the CJ organism after 100 days;
2. The longest half life for any component of Aroclor 1016 is approximately 25 -- 30 days.
3. For pure compounds, there is evidence to sugg-est that C2 and C3 have different rates of degradation and each
is specific to certain basic structures; in complex mixtures, this does not appear to be the case since C2 and C3 degrade the components of Aroclor 1016 at approx imately the same rate and to approximately the same amount.
4. "Analytical developments show that the electron capture detector response to individual components can be predicted with an accuracy sufficient for most environ mental analytical problems using packed columns and that with capillary columns quantitative__measureiaents can be made upon degraded P.C.Es at the 0.01 ppm level
0007268
WATER PCB-00055558
2.
INTRODUCTION
A previous review report (No. MP 10103) discussed
results obtained for the biodegradation of pure chlorinated
biphenyls using a biphenyl degrading organism C2 (the Sudan
organism) obtained from Professor Charles Evans of the
University College of North WalesBangor. The effect of
C2 on commercial and development samples (1242, 1016, 717,
762 etc.) was also discussed but, because of analytical
'
difficulties encountered in the identification of specific
components in the mixtures, only very limited interpretation
could be made of the results.
Since the issue of that report the identification of components has been greatly improved and, in the work reported here, Aroclors 1242 and ICTl6 have been analysed after submission to biodegradation in the presence of biphenyl by two cultures C2 and C3 for one hundred days. Improvements have been made in the quantitative analysis and it has been possible to study the change in individual isomers at levels below 0.05 parts per million.
1. DETAILS
1.1 Organisms used for degradation of Aroclors 1242 and 1242B
^ Two organisms both received from Professor Charles Evans at University College of North Wales,Banger have been used for biodegradation.
The first organism C2 is that originally received and used for the initial work on the -degradation of pure compounds. This was isolated in a soil sample from the Sudan and is reported as being a nocardium of the order actinomycetes.
The second organism C3
isolated from a canal mud
sample in the screening work carried out by Professor Evans
student, C. Harrison. This is reported as being of the
pseudomonas family.
.
,
The mode of attack by these organisms on biphenyl has been studied by Professor Evans' group and a simplified scheme
is given later in the Appendix.
\
WATER PCB-00055559
3.
1.2. Preparation and maintenance of stock cultures of biphenyl degrading organisms
The procedure used is identical to that reported
earlier (Review Report No. MP 10103).
.
-
1.3. Procedure for studying P.C.B. biodegradation
A number of changes have been made in the procedure
used to study biodegradation. These have been made to
increase the number of samples examined at any time and to
improve the qualitative and quantitative accuracy of the
analytical method.
*
(i) Addition of Orbital Incubator
To increase capacity, an orbital incubator was
purchased (Gallenkaup) with a capacity of 15 x 1000 ml,
28 x 500 ml. or
x 250 ml. flasks.
Past experiments have been designed so that the complete contents of any shake flask have been extracted and analysed. A more attractive method would be the use of aliquots whereby the fate of a ^g/^ple in any flask could be studied over a period. This method was rejected earlier because (a) the flask shaker was too small to handle the larger volumes needed foraliquot work and (b) it was strongly suspected that the sample would not be homogeneously dispersed in the medium but may be partly adsorbed on the flask wall.
In view of the increased size of flask, which could be accommodated in the incubator, it was felt that the use of aliquots should be evaluated - if successful the variation in results caused oy the use of separate flasks would be eliminated and a more varied biodegradation programme could be designed.
0007270
WATER PCB-00055560
The evaluation was carried out as follows :
Six 1 litre flasks were dosed with Aroclor 1242 in the normal way. Each flask contained 700 mis of water with an Aroclor 1242 concentration in the flask equivalent to 5 ppm. If the aliquot method was suitable each 100 ml aliquot of water should contain 5 ppm of 1242.
o The flasks were shaken in thr incubator (l.25 r.p.m., 25 C) for eight days after which a 100 ml aliquot was taken from each flask. Of the remaining 600 mis of water in each flask, 500 ml was discarded and the remaining 100 ml recovered for analysis. These first and final aliquots were extracted with pentane; in the case of the final 100 ml aliquot the pentane was first used to remove any Aroclor 1242 adhering . to the flask. The pentane extracts were analysed using packed column gas chromatography. Results are given below, the figures in brackets are the theoretical figures which should be obtained if the aliquot system is reliable.
1242 content (ppm) 1st Extr/act
1242 content''(ppm) Final ExI.t
v-
1 i.4 (5.o) = r.y
24.4 (5.0) V.
2
1.7 "
/6.V .
22.6 "
'v
3 0.8 "
24.5
"
*-?
i4 s 5
6
0.7 "
1.3 " 1.0 "
V--- 7.T fe
35.7 25.5 29.8
" "
M>
-7~' r
It can be seen from these results that the aliquot systep is not suitable for aqueous samples containing Aroclors and that adsorption to the container wall is so large that this factor is likely to be important in the interpretation of any data from
similar experiments.
JLZ. r. -- tf
jd.
Si"/ *
0 su-
fi:*-r-
*1
r
-
rst
.
ir--.
_,,
_
F'tvf
n
p
'
.
' ^0007271
WATER PCB-00055561
Thus the problem still remained of how to obtain the maximum information using a limited number of samples. In previous work each sample under study had three flasks prepared as follows :
1. Sample + Culture + Nutrients + Biphenyl
2. "
"
" no Biphenyl
3. "
"
" " ' " + BgCl2
In every case to date, the sample with mercuric chloride has given results in agreement with a normal standard not submitted t-.> biodegradation and therefore this series of flasks has been excluded from the present work. This has increased the relative capacity of the incubator by 30^.
1.4. Improvements in the Analytical Procedure
The details of the analytical method used are given
in the Appendix.
.
1.4.1. Identification of Components
The development of a suitable analytical method has been a major problem in the study of the biodegradation of complex commercial and development samples of P.C.B's. Packed column gas chromatography using the electron capture detector will'give a measure of whether a complex sample is undergoing biodegradation but the resolution attainable is not sufficient to determine tbe fate of individual components. Without this knowledge and because the response of the E.C. detector to individual P.C.Bs varies with structure, quantitative results must be viewed with caution.
It is therefore necessary to use high resolution capillary columns to obtain detailed information but a further complication is introduced in that there are insufficient pure P.C.Bs available to identify all the peaks in a chromatogram (up to 50 in 1242) using the normal procedure of "spiking".
w i- Lld 0007272
WATER PCB-00055562
6.
In the' early stages of this work it was there fore decided to concentrate upon the use of capillary columns coated with the non polar phase Apiezon L. While these have a poorer resolving power than many polar columns of equivalent length they have the major advantage in eluting components with respect to boiling point and this property can often be predicted from a knowledge of structure and -the behaviour of similar compounds.
Emperical rules were drawn up to predict, the probable retention times of unavailable P.C.Bs, the 'rules being based upon steric factors, molecular weight etc. Such rules aided in the identification of certain components bait were not sufficiently detailed or established to cover all components.
This approach was discussed with Welti,Sissons and Telling at Unilever who were working along similar lines. A thorough investigation by this group using confirmatory techniques of N.M.R. , mass spectrometry and the spiking procedure resulted in complete (within experimental error) identification of all components in 1242, 1254 and 1260.
. This work is awaiting publication but we have had access to the data for the previous six months and, combined with our own, this has been used for the identification of all components named in the results section.
1.4.2. Quantitative Accuracy *_
While improvements have been made in identification of components, the quantitative accuracy of the gas chromatographic method has still to be improved. Use of capillary columns mainly overcomes the difficulty of merged peaks but it has a disadvantage in that it requires more concentrated samples than packed column gas chromatography.
To overcome this, the concentration proceudre described in the Appendix was developed. This involves concentration of the pentane extract to a low volume followed by addition of a small known amount of decane. This allows complete removal of the pentane giving a concentration factor of up to 200X without significant loss of P.C'.B. components and enables accurate measurements to be made on degraded components at levels as low as 0.05 ppm.
0007273
WATER PCB-00055563
7.
1.4.3. Calibration
,
Work by Emery et al (M.C. Physical Chemistry
Method 70-20. N.N. 1348322) has shown that the F.I.D. response
factors of chlorinated biphenyls depend upon chlorine content
and that within any group of compounds of the same chlorine
number, structural differences have a minimal effect upon
response factor. Thus, in any high resolution chromatogram,
if the chlorine numbers of the peaks are known, response factor
correction can be applied and a true figure for either the
composition of the Aroclor or its concentration in a sample
can be calculated.
'
Unfortunately, because of sensitivity limitations,
the F.I. detector cannot be used for determinations involving
very low levels of P.C.Bs and the electron capture detector
must be employed.
..
There has been much speculation on the quantitative
accuracy of this detector for P.C.B. analysis since it is known
from other applications that its response is very dependent
upon structure; work with pure components within Monsanto and
elsewhere (eg. see Zitko et al Bull Environ Contam and Toxicol .
1971 2 pp I6O-I63) has indicated that with P.C.Bs there can
be large differences in response for compounds of the same
chlorine number but different structure
.
e-g-
Response 2 4/ dichloro biphenyl
44' n
n'
_12 . 2
It was therefore decided that for accurate quantitative analysis using the E.C. detector the most reliable approach would be to determine the ratio for each component of the E.C.D. to F.I.D. response, use this to convert the E.C.D. chromatogram to an "equivalent" F.I.D. chromatogram and apply the F.I.D. correction factors calculated by Emery et al.
.
fTnh, e ratio of,, E_ .C .D. response is relatively easily x.1.P.
obtained by running the same standard sample on a capillary column using a flame ionisation detector, then repeating the experiment (after dilution) with an electron capture detector"(See Figs(jj}& 10). Peak areas are calculated then ratioed. The ratios obtained for each component can then be used for all subsequent samples provided that the column used lias suitably high resolution.
r tel 0007274
^7.
WATER PCB-00055564
8.
t t. 'f'1 ' ~r'^e
s-c
In carrying out this experiment and also in previous work it was noted that for all the concern about
" /}
unpredictable response of the E.C.D. the chroma-tograms
obtained with the two detectors were remarkably similar and
\ calculation of the E.C.D. ratios for all peaks shows that
F.I.D.
large differences between the two detector responses are
' only observed for a small number of components.
It is suspected that the similarity of E.C.D. . response factors of compounds of the same chlorine number .
but different structure is related to the fact that almost all the components of Aroclor 1242 (and higher Aroclors) contain at least one chlorine in the ortho position. Such compounds will have non coplanar benzene rings, there will be much reduced conjugation and this general property may have such a large effect upon E.C.D. response as to make other structural differences of much lower importance for components of the same chlorine number. This would explain . the anomalous E.C.D. response factor of the unhindered 44' dichloro biphenyl.
.Initial measurements with pure 33' dichloro biphenyl show that this compound also has a low E.C. response almost equivalent to that of the 44' dichloro biphenyl.
As discussed, if high resolution capillary
columns are used the E.C.D. ratios coupled with the F.I.D.
F.I.D.
will give an accurate quantitative figure for P.C.B. content
at low ppm and ppb levels.
If the E.C.D. ratios for each set of components F.I.D.
with the same chlorine number are averaged (neglecting components of very low concentration) an unexpected result is obtained viz.
^ 0007275
WATER PCB-00055565
9.
To convert dichiorobiphenyl E.C.D. areas to
F.I.D.
areas
using
E.C.D. F.I.D.
ratio
divide by C
tri " tetra "
*i n
"1 "1
To normalise F.I.D.(using M.C.data) areas of dichloro diphenyls
H ft
If
" " tri "
n
n
n
" tetra ''
multiply by C M "1 I " 1
Overall result
To normalise E.C.D. areas dichlorophineyls " tri " " tetra "
multiply by 0.9 0.7
1.1 1.1
1.5 1.2
i.e. 3 i.e. 1
1.
Thus, within the requirements of most pollution/environmental
work the total area of components of a chromatogram of P.C.Bs can
be quantitatively related directly to a chromatogram of a standard
P.C.B. mixture (preferablj' not to a pure P.C.B. since this may
have a response removed from the average).
.
Since the start of the environmental P.C.B. problem most of the published work has been carried out with packed columns and E.C. detection. In many cases authors have advised caution in the interpretation of results because of the expected difference in response factors of the individual PCBs with the E.C. detector. It would now seen that ia the case of Aroclor 1242 there is less need to apply so much caution to the quantitative figures.
This, however, still leaves a major query as to whether packed column work for environmental samples is reliable since interfering non P.C.B. componenxs with high E.C. responses present within the P.C.B. envelope cannot be detected.
a ~ r~~- T U : 'i.
n
isi^a 0007276
WATER PCB-00055566
10.
RESULTS
The results obtained for Aroclor 1242 and 1016 together with interpretation and discussion are given in Sections 11.3 and 11.4.
II.1. Sources of Error in Interpretation
*.
In interpreting the results it must- be emphasised that there are still unknown factors which may cause significant errors. Two such sources of error are con sidered below :
A. Identification of components
As discussed earlier components have been identified using one or a combination of the techniques of spiking, N.M.R. and mass spectrometry. All such techniques are open to error in a complex sample of this type, even, in some cases, the authenticity of the original component used for spiking may not be guaranteed.
B. The graphs for degradation of components ere prepared from results obtained for separate samples of Aroclors taken at 52 and 100 days. Thus while the samples have been prepared under as identical conditions as possible, once biodegradation is initiated each sample is an isolated system and different rates and/or processes may occur. Every attempt has been made to ensure reproducible conditions but it has been found in a number of previous runs that occasionally a 50 day sample shows better degradation than a 100 day sample.
An attempt to reduce the chances of this situation occurring will be made in future by the introduction of the "viable cell count". This is discussed below.
II.2 Viable Cell Count
In the discussion on degradation of 1242 and 1016 the results have been interpreted without considering in detail the effect of time on the growth of the organisms in samples in a closed system.
p b c. - *-
'rs.'vTt a \ :1 r1 ?.' ?
LdiM L EiP vksA 0007277
WATER PCB-00055567
11.
It is known that under optimum conditions a culture of micro organisms will have a growth curve for .viable cells similar to that drawn below : '
In the experiments described, the viable cell
population has not been counted when samples have been
taken, as it has been assumed that where the rate of
degradation is considerable, i.e. during the first 50
days, this was unnecessary. However, when the residual
material becomes very low i.e. after 100 days, the viable
cell population may be in the region AB on the graph.
Here the reduction in cell count is several orders of
magnitude below the maximum count but the concentration
of P.C.B. is reduced by less than two orders of magnitude.
Thus the relative efficiency of degradation in the closed
system will reduce considerably with time.
*
r
0007273
tu Li **-
WATER PCB-00055568
12.
This is not the case in most normal environments
where the P.C.B. could he exposed to a number of organisms
at different times, each working at high efficiency.
.
11.3 Biodegradation of Aroclor 1016
The percentage degradation for Aroclor 1016 by C2
i 7 and C3 after 52 and 100 days is given in-Table I "and schematic diagrams of the rates of degradation of the individual components are given in Fig. 7.
The rate graphs are meant for illustration only, since insufficient points for each component have been obtained to allow accurate decay curves to be obtained. If the graphs are used as drawn, to obtain an approximate . half life for each component (i.e. time to 50^ degradation.) then it can be estimated that the slowest degrading component has a half life of 33 days with C3 and 28 days with C2* If however, degradation is assumed to be exponential (which is inferred if component half life is used as a measure of efficiency of degradation) the figures are lower still probably in the region of 10 -- 20 days. In practise even these numbers are on the high side since, as has been discussed earlier, efficiency of biodegradation will fall off with time in a closed system.
The graphs show that degradation appears to be smooth and relatively rapid with both organisms. Small amounts of degradation products can be seen in the early part of the chromatogram hut the retention times of these confirm that they are not chlorinated biphenyls.
i
' It has been noted earlier that the mechanisms of biodegradation for C2 and C3 with biphenyl differ (see Appendix Fig. 9) and it would therefore be expected that the high resolution gas chromatograms of Aroclor 1016 degraded by the two organisms would show major differences. In practice while there are differences these are relatively small (in comparing chromatograms it should be borne in mind that although a 1 ppm. standard is used the original concen tration was 5 ppm.)
This suggests that when the organisms after adaption
with biphenyl are exposed to a wide range of components they
are capable of further adaptability to suit the available
food source, that degradation is uniform and extensive after
52 days shows that adaptation is not difficult. This is
supported for C2 by the evidence in the literature that the
Actinomvcctes family are known to adapt to a wide range of
food substrates.
--r
.. - -- -
r. n
*
w w ^eoon^
WATER PCB-00055569
13.
II.4 Biodegradation of Aroclor 12**2
The percentage degradation for Aroclor 1242 by Co and C3 after 52 and 100 days is given in Table I and the apparent rates of degradation of the components are given in Fig. 8.
The comments made earlier concerning half lives of the components of Aroclor 1016 also apply in this case.
The graphs and the chromatograms from which they are
derived show that biodegradation appears to be more
complicated and while degradation is considerable after
100 days the rates of degradation for many components do not.
follow smooth curves.
'-
Reasons can be given for the differences between the biodegradation of 1242 and Aroclor 1016 but these must be treated with caution : --
Two main differences are apparent (a) certain components in 1242 appear to decrease in the first 52 days then increase in the second period. (b) the rates of degradation for C and C3 for individual components differ far more than with Aroclor 1016.
Both differences may be caused by the effect of the higher chlorinated components which are present in greater concentration in 1242 than in 1016.
' In the first case, these may be degrading to give . lower molecular weight components which elute with the same retention times as the lower chlorinated biphenyls or, in fact, the higher chlorinated biphenyls may lose chlorine and gain hydrogen by an unknown process to give the lower chlorinated compounds.
In the second case, initial degradation of the higher chlorinated materials may give rise to products which have different toxicities for 02 and C5 and, in a medium of increased toxicity, these organisms will utilise the available food by different mechanisms than they would in a non toxic medium.
Again, in future work, the effect of toxicity may be detected using the "viable cell count" procedure discussed in Section II.2.
%
0007280
W m 'La Wse*
WATER PCB-00055570
14.
11.5 Relationship between structure and case of biodegradation
The present results on 1242 and 1016 for C2 and C3 provide an additional means of studying the effect of structure upon biodegradability and it should be possible to .obtain a considerable amount of information from relatively few experiments. Because of the complex nature of the degradation process and the apparent ease of adaptation of the organisms it is felt that the present data is'insufficient, and that further experiments should be completed before detailed correlation between structure and biodegradation are considered or attempted.
III. FUTURE WORK
III.l. Quantitative Accuracy
It has been suggested earlier (Section 1.4 III) that the response, of the electron capture detector is largely con ditioned by the non coplanarity of the benzene rings in the chlorinted diphenyl molecule.
Samples of unhindered chlorinated niphenyls have been supplied by Unilever and these will be examined to decide whether this postulate is true.
IIIv'2 Sample Programme
^ a) A repeat series of Aroclors 1242 and 1016 is under
way using C2 .and C3 and degradation will be followed until
complete disappearance (50 day ready Sept. 6th).
.
b) A mixed culture of C2 and C3 is being used to attempt biodegradatiou of Aroclors 1242 and 1016 to determine whether the organisms can co-exist and still work equally effectively.
c) A river water die away test on 1242 and 1016 has been initiated for a long term study.
,
d) A variety of development samples including chlorinated terphenyls has been subjected to biodegradation by C2 and C3. The results on these will be reported separaxely
when complete.
r
EG
_ r[V
ti Ek k
0007281
WATER PCB-00055571
III.3 Viable Cell Count The viable cell count method is being carried out
to obtain expertise in this technique. It will then be applied to each sample submitted for analysis.
mM 0007282 Ulfc**
WATER PCB-00055572
Appendix
1. Table 1
Jf Biodegradation with C2 and Cj after 51 and 100 days
2. Table II Half lives of components of Aroclor 1016
3. Fig.l. 4. Fig.2. 5. Fig.3. 6. Fig.2a. 7. Fig.3a. 8. Fig.4. 9. Fig.5. 10. Fig.6. 11. Fig.5a. 12. Fig.6a.
Chromatogram of 1 ppm of Aroclor 1242 n 5 ppm " tf n
n tt n tt tt.
tt n tt ' tt tt
* tt
tt n t n
1 ppm "
tt 1016
5 ppm " tt tt tt tt tt tt n
w tt ft tt t?
t tt n tt tt
(0 days) @ 51 days (C2)
100 days (Cg) 51 days (C3)
100 days (C_) . 0 days
51 days- (C2) 100 days (C2)
51 days (C_) 100 days (C^)
13. Fig.7. 14. Fig.8.
Bates of degradation for components of Aroclor 1016 (C2 and
tt tt
tt
tt
tt
tt n
1242 (C2 and
15. Method for G.C. Analysis of degraded samples
16. Fig.9.
Metabolic Pathways for degradation of biphenyl with C2 &
17. Fig.10. Chromatogram of Aroclor 1242 F.I . detector.
18. Fig.11.
s
w
tt It
tt E.C . detector.
19. E. C.D. and F.I.D. Relative Response Factors.
L 'U ki Li_' tlkJ-i i< t 111
0007283
WATER PCB-00055573
TABLE I
% Biodegradation after 52 and 100 days
Time
52 days+ 100 days *
1242 C2 C3
88 ~95
?6
" ..... ... .. """' t
1016
j
C2 C3
96 > 98
91
>96 - i;
+ Analyses carried out using packed column method
* 100 day figures estimated by comparison of capillary column chromatograms for 52 and 100 days.
urJJL *MJl JfciL
\ 000^'284 WATER PCB-00055574
TABLj! II Half Lives of Components of Aioclcr 1.016 (days)
'S'J--4 Vi0e'\
D*Xk
Component
------ e,(
|
- u" /
JL>'
1
C3
2. 2'5! 2. 2'.4'
"Tri-JhT Chloro Biphenyl
w tt
2 2'3' and/or1^ 2'6 '
^4, 2'6'
Di/tri **
n
"
tt
44' Diehlor0 " 2,2'4'6' and/or 25,2 '6'^^' Tetra Chloro Biphenyl
2 3'5' and/or
'
4 2'3' .
*^
3 2'4'
3,3*6 1
1/7 1
Trichloro Biphenyl
n tt i tt
t'/? 2 3'4'
tt tt
2, 2'3'5* and/or 25 2'5' Tri/Tetra CJiloro Biphenyl
2, 2'4'5*'and/or 24, QltJI n
n
tt
3, 2'3'6' and/or 3, 2'4'6' "
"
"
"
4,2'3'6*
' tt ti tt
23, 2*4'
ti ti i
2,2'3'41 and/or 23, 2 ^1
n n 11
Unlaiown
j 26
l
26
<v 26 33
26 . 33
27 32
25 27
30 30
26 26
26 26
^26 ~26
26 26
26 26
26 26
26 26
26 26
i
28 | 24 '
28 124
26 j 24
* Peak/ off scale at attenuation used,half life estimated.
0007285
WATER PCB-00055575
Gas Chromatographic Analysis of Biode graded Samples
Pentane extracts were obtained in a manner identical to that previously reported.
Method
A suitable aliquot (50 or 25 mis) of the pentane extract was evaporated to low volume (2 - 5 ml) in a Dreschel bottle on a water bath at 60C using a nitrogen purge.
n Decane (0.1 ml) was placed into a tared specimen tube
(15 mm x 45 iam) which was then reweigbed. The concentrated
pentane extract was pipetted into the decane followed by a
small amount of pentane used to rinse the Dreschel bottle.
The n pentane was then removed at room temperature again
using nitrogen arid the complete removal of pentane confirmed
by reweighing the specimen tube.
__
Standards of Aroclor 1242 and 1016 were prepared as above by evaporation of 25 mis of a 1 ppm solution.
0
The rate of loss of any component was determined by measurement of the peak height of that component.
The concentration procedure was checked for reliability
by running standards in duplicate - results were repeatable
within + 5$.
Gas Chromatographic Conditions
Column - 200' s/s capillary J>0 thou bore (ex Phase sep. )
coated with Apiezon 1 using the method of Malec.
E.J. (
).
Temperature Detector
210 C Ni65 (H&P) at 525C
Carrier
Argon/Methane 95/5 Input Pressure 5 p.s.i.
Internal Standard - None
Chromatogram Duration 90 minutes.
-;vm!
, w - i- --' `
Ll w-
0007256
WATER PCB-00055576
TABLE 3 . E .C .D . AND F . I . D . R e la tiv e Response F a c to rs
Pk No : i
pp u H Pm
o CM
___
r o
in VinO
ON n-
in 00 00 VO
-4<
pH
o
pH
in m
o
tCnM
in tn
or~\
o
o in
o o o o pH o pH pH pH pH rH M o pH pH
r
p
pH
O
Ov
o
tn 00
00 o
r4~*.
CinM
rH
CM
in o
frH~
4*
pH
o
pH o n 4*
S
CM m
Em
oo
o rH O o o O o O o pH pH O o o o
P w
CM o
vOO
oo
1
0tn0
vHo
nin
*
o
CM -4*
in o
ion
00
pH
Ov pH
o
o
rH
Si
tCnM
pinH
in
m
o o o o o o o o o rH CM o. O o o
CT\
in 4*
00 o
rH M CM
n* o CM o CM pH oOo
1
in
pH
in CM
ooo
i oin
o
CM
t
m o
vo
pH i
o
~ '----
I
I
pH
pH
C4
o o
VO VO
pH pH pH
I
i
CM tn
4P rH
0o0
in o
ooo
1
0o0
in tn
pH
00 o*
Cl o
ooooQ
CO CO
* CD -- CD
o vcsrtkII
`AJW3
i... ' D f ; * -T.
* :i. ; J 11 v(. 0) cA__--tJ
C)
Sc c.
cm CM in CM tn in tn tn CM
tn tn tn tn in 4* 4* -4*
jp 4*
-4*
m sm
4P 4P 4< -4* 4*
VO
in VO
r
00
0 o
H
H
H
CM
H
tn 4*
rH rH
in VO
rH rH
n 00
pH pH
o
CM
rH
CM
CM CM
-41
CM
CM
in
CM
n* CM
00 CM
8
o m
m
CM
m
ir> VO mm
fN.
tn
oo m
! 1
i
WATER PCB-00055577
FIG. 9 .
Metabolic pathways for the biodegradation of biphenyl with C2 and
'M\*c-
-~*T'
000r288
iiL'ia- uu
.t. Vi-, ::
t-
WATER PCB-00055578
II
i
I
i
WATER PCB-00055580
0007290
03 -'i i'o> .1| ii
.4
J I
i
i
WATER PCB-00055581
0007292
ii
.. !
, ...
-sH~*
o CofNSis . {
CO
Cl
J1242 100d c.
f, *
`I
f
ii i
t
t
i ii
?. 6 2 > 0 0 0
i I
t
l *T\
WATER PCB-00055583
WATER PCB-00055584
0007295
WATER PCB-00055585
/
nri07296
* *4
j;.
*. ..j
r.' _-_i
r-
CXi C\i
o
cs
WATER PCB-00055587
I
0007298
WATER PCB-00055589
r )
r.
r.
r ?v
frt>-.\.".. r V
J
jp i IT'-
CD v? CO CT O
r
WATER PCB-00055590
\
WATER PCB-00055591
0007302