Document p2BrBawnbN5V32jx1K1kNeVbE

Georgia-Fbcific 4^. 1974 gypsumboand for wall and ceiling systems INDEX G-P Gypsumboard Products Description..........3, 4, 5 G-P Gypsumboard Edge Description...................... 5 G-P Joint System Products................................... 5, 6 U.S. and Canadian Product Specification Directory. 7 Gypsumboard Nail and Screw Selector Guide........ 8 Technical Data--Wall Systems ... .8, 9,10, 11,12,13 Technical Data--Floor/Ceiling Systems..........14,15 System Installation Details and Diagrams..........16,17, 18,19, 20, 21, 22, 23, 24, 25 G-P Texture Information............................................ 25 Details--Predecorated Panels to Gypsum Substrate ............... 26 Gypsumboard Application over Masonry Walls. . . .26 Water Resistant Gypsumboard................................ 27 Solid and Semi-Solid Gypsum Partitions.................27 Wood and Steel Stud Application............................ 28 Column Fireproofing.................................................. 28 G-P Shaft LinerTM--Gypsumboard Enclosure System ....................29, 30, 31,32, 33, 34, 35, 36, 37 G-P EternawallTM Vinyl Surfaced Gypsumboard .38, 39 Georgia-Pacific Distribution Centers...................... 40 TESTING FACILITIES Georgia-Pacific's major research and development center, a showplace for the nation's gypsum industry, is located at Tigard, Oregon. The two adjacent structures, with 16,868 square feet of floor area, are equipped with many types of research and testing devices. Quality control is an important factor in the type of product that Georgia-Pacific markets. Staff technicians develop and continually check G-P gypsum products such as Tile Backer Board, Insulating Boards, Vinyl Surfaced Eternawall and other products including wall and ceiling systems, plasters, pottery and metal moulding plasters and agricultural gyp sum for farm use. G-P developed the use of glass fibers to strengthen gyp sumboard, high strength Densite plaster and special lath for veneer plaster, and the lab is carrying on a vigorous product development program. The technical department conducts field and manufacturing plant services, solving difficult technical problems n d de velops improved manufacturing methods. Gypsum products are tested several ways at the Tigard lab. Gypsumboards are subjected to severe stresses and ex treme temperatures to make stronger and more fire resist ant gypsum products. Sound tests are conducted to develop wall and floor/ceiling systems to assure ``sound privacy" for today's residential and commercial construction. WARRANTY The assemblies and information in this brochure have been developed based on practical construction methods. However, since the Georgia-Pacific Gypsum Division does not have any prior knowledge of a specific building design and its construction or the methods of application used with its products, no warranty of performance is made. All test results have been obtained under controlled laboratory testing conditions where environmental variables are re duced to a minimum. In the field, such laboratory conditions are not always met, since many other variables may be in troduced. Laboratory results may exceed field test results but the laboratory tests under controlled conditions are the only logical way to compare the performance of different assemblies. The Gypsum Division of the Georgia-Pacific Corporation makes no warranty that the performance of assemblies in the field will have a performance equal to or better than that developed in the test. LIMITATIONS Georgia-Pacific interior gypsumboards are non-load bear ing panels. Regular Gypsumboard panels are not rec ommended for use under extremely moist conditions. G-P Tile Backer Board is to be used in bathrooms or other high moisture areas. V4" gypsumboard should only be used as an application over existing walls or as the first layer in a sound rated system Because of the limitations of man ufacturing equipment, the maximum length available in gypsumboard is 16 feet. 2 SGP 0025174 GYPSUMBOARD PRODUCTS Georgia-Ffecific ^ Georgia-Pacific Gypsum Division manufactures a full range of products to meet the needs of the construction industry. The versatile gypsum product provides builders with light weight construction materials that are workable, fire and noise resistant and time saving. G-P research facilities have responded to the industry's requests and have de veloped the following multi-use, highly reliable, low cost products. G-P GYPSUMBOARD EDGES T--Tapered B--Beveled (Special Order) S--Square T & G--Tongue and Groove RE--Tapered with Round Edge MB--Modified Beveled Edge See page 5 for detailed description PRODUCT DESCRIPTION G-P REGULAR GYPSUMBOARD G-P Regular Gypsumboard is faced with a strong, cream colored paper which will accommodate almost any type of decorative treatment. The back paper, which is gray, is as strong as the face paper. The `/j" and %" gypsumboard Tapered Round edges are recommended for single layer application in new construction. They are designed to be reinforced with G-P Joint System prod ucts resulting in a smooth, seamless surface. Square edges are recommended for use where joints will be exposed. The resistance to fire expo sure and sound transmission increase with tho use of greater board thickness and the number of layers of board used. Bevel edges can be usee where a panel effect is desired. Thickness Widths Lengths Edge %" 4' 6'to 16' T, S, B, RE y2"%" in even feet r G-P FIRESTOP' GYPSUMBO\RD G-P Firestop develops 45 minute to 3 hour fire resistant ratings in various wood and steel wall and floor/ceiling assemblies. Unexpanded vermiculite in the core balances gypsum shrinkage by expanding when exposed to heat, while the textile glass filaments keep the core intact even after the chemically combined water has been released. The results are a thermal stabilized core. y2" 4' 6' to 16' T,S, B, RE Yb" in even feet G-P 1/4" GYPSUM SOUND DEADENING BOARD G-P V4" Incombustible Gypsum Sound Deadening Board meets the requirements of the most sophisticated sound control systems available with the added convenience of being one of the Yk" 4' easiest sound control materials to install. When combined with other gypsumboard, it reduces sound transmission, has high structural strength, is non-combustible and incombustibility. It has a distinctive green face paper. When applied over 2Vi'' steel studs or 2 x 4 wood studs, one layer of Vi" G-P Firestop Type XXX over one layer of Vi" Gypsum Sound Deadening Board produces a 1-hour fire resistive wall and a 45 S.T.C. 8' S G-P REGULAR TILE BACKER BOARD This is a water-resistant gypsum product with a light blue face paper, designed for use as a base W 4' 8'to 12' T for the adhesive application of ceramic, metal or plastic tile. The gypsum core consists of non-com bustible gypsum rock, combined with an asphalt emulsion giving high water resistance. Ideal for bathrooms, kitchens, powder rooms and other moisture areas. G-P Tile Backer Board.can be erected as easily as regular gypsumboard and requires no finishing of joints or nail heads with joint treatment nor further waterproofing under tile applied adhesively unless required by local code G-P FIRESTOP' TILE BACKER BOARD Same as Regular Tile Backer Board plus the addition of unexpanded vermiculite and glass fiber reinforcement which gives increased fire protection and strength. Where fire rated assemblies are required in areas subject to moisture, such as partitions between bathrooms and other interior areas, most building codes allow the use of G-P Firestop Tile Backer Board. The use of 5/3" Firestop Tile Backer Board will give the same fire resistant rating as'other Firestop board. 4' 8' to 12' T G-P REGULAR INSULATING GYPSUMBOARD Regular Insulating Gypsumboard is regular gypsumboard with bright aluminum foil laminated to the back surface. The foil paper provides a continuous vapor barrier on the warm side of the wall. 90%To have reflective insulation value, FHA requires the foil to face a minimum air space of %". The aluminum foil, facing a %" minimum space, reflects of radiant heat, providing insula tion qualities equal to V2 " of fiberboard insulation (tested by U. S. Bureau of Standards). Panels must be installed with foil side against the studs. Yb" 4' 6'to 16' T, S, RE y2" Yb" G-P FIRESTOP' INSULATING GYPSUMBOARD This is the regular insulating gypsumboard with the addition to the core of unexpanded vermiculite and glass fiber content for increased fire protection. Through the proper use of this product desired fire-rated assemblies can be achieved. Yb" 4' 6'to 16' T, S, RE SGP 0025175 3 PRODUCT DESCRIPTION Thickness Widths G-P REGULAR ETERNAWALL "--VINYL SURFACED GYPSUMBOARD Standard Line. Colors--Avocado, Gold, Flax, White, Beige, Stucco, Buff, Willow Green, Fawn, Snow drift White, Alabaster, Tangerine, Cherry, Pecan and American Walnut. New Colors and Textures. Colors--Honey Maple, Shadow Beige, Teak, Rosewood, Oak, Desert Yellow, Smokey Mint, Spanish Haze, Winter Green, Tarnished Gold, Powder Brown, Chocolate Malt, Autumn Orange, Burnt Sugar, Pebble White. This panel has the vinyl surface factory laminated to Regular Gypsumboard. Available in a variety of colors and textures, it provides beauty and utility to commercial, institutional and home interiors. Eternawall is strong and resilient. The solid gypsum core is non-combustible. Eternawall colors won't fade. The deep linen-textured vinyl surface can be scrubbed without damage to color, texture or design. Because of its ability to take hard wear and to resist stains, Eternawall is ideal for restaurants, hotels, clubs, and hospitals as well as home use. It is also ideally suited for movable partitions. Vi" (Special order r&5/n 4' G-P FIRESTOP ETERNAWALL --VINYL SURFACED GYPSU MB04 This panel has the vinyl surface factory laminated to a Firestop panel which has unexpanded vermiculite and glass fibers added to the core to give it additional fire resistance. With this tech nically designed gypsum core, a 1 hour or greater fire rating may be obtained on wail assemblies. Same colors available as with regular Eternawall. Vi 4' Yl" Lengths 8' (Other lengths available on special order.) 8' (Other lengths available on special order.) Edge MB MB G-P FIRESTOP GYPSUM SHEATHING Treated--G-P Firestop Gypsum Sheathing consists of non-combustible gyps m rock combined with an asphalt emulsion to provide high resistance to water. All G-P Firestop Gypsum Sheathing is manufactured to meet ASTM C79 including requirement for water resistance. This eliminates the need for building paper (except where required by local building code). An untreated (no asphalt emulsion) gypsum sheathing is available. The 2' wide sheathing, applied horizontally, is made with precision formed tongue and groove edges. The 4' wide square edge sheathing, applied vertically, completely eliminates the need for corner bracing. It is designed to meet requirements of FHA Technical Circular 12. Vi 2' 8' T&G 4' 8' & 9' S G-P GYPSUM FIRESTOP BACKER BOARD G-P %" Firestop Gypsum Backer is used as a backing for decorative surface treatments of acoustical plasters, tile, plywood and various veneers. A single layer application of %" G-P Fire stop Gypsum Backer on both sides of wood or steel framing, enables loadbearing or non-loadbearing wall assemblies to resist temperatures rising to 1700 F. in one hour following the ASTM standard time temperature curve for one hour. Firestop Gypsum Backer consists of a gypsum core with unexpanded vermiculite, reinforced with literally miles of high tensile strength glass fibres, firmly bonded to a fibrous gray paper on both sides. w 2'&4' 8' to 16' S, T&G Yz" G-P REGULAR BACKER BOARD G-P Gypsum Backer Board is designed for first or base layers in field lamination of gypsumboard, for acoustical tile and other compatible materials. Provides low cost, even surfaces for further decorative treatments. It may be applied over loadbearing or non-loadbearing wood or metal framing with nails, screws or staples. r 2'44' 8'to 16' S, T&G %" Yi" PREDEC ' TEXTURED GYPSUM This combination of non-combustible gypsumboard with factory applied, distinctive, evenly balanced textures is a new development in the construction industry. The textures are baked on and are available in 2 patterns, sand and stucco. The panels are 5/n,", l/i" and thick with square edges. The texture is a thermo-set in White, Beige, Gold and Light Green water resistant paint. This product eliminates job site finishing and installation time. It is impact and abrasion resistant and ideal for residential construction, factory built mobile and modular homes and movable or fixed partitions. It can be cleaned with a damp cloth and mild soap and water. PreDec has a flame spread rating of 20. Samples available on request. 5/16" (%" & 5/a" special order) 4' cut to size -S SHAFT LINER G-P Shaft Liner is a laminated gypsumboard partition for enclosing elevator shafts, stairs, smoke towers and air ducts. It is a non-load bearing wall, designed for resistance to air pressures without excess deflection. This system can save over 20 lbs. per square foot compared to masonry and is noncombustible, can be erected from one side and eliminates the need for scaffolding. The partition consists of a basic prelaminated core 1%" thick by 24" wide which fits into a top metal "J" track and bottom "L" runner. Metal "T" splines separate each core unit; and the shaft liner is then secured to the "T" splines and both top and bottom runners. This system was fire tested in accordance with ASTM El 19, and is the only U.L. approved shaft enclosure system on the market G-P shaft liners available in lengths up to 16'. With G-P's own auxiliary bracing system heights beyond 16' are attainable. Various fire resistive and sound ratings available. Solid and cavity wall types available. See pages 29-35 for details. 1%" Core plus facing layers 2' cut to size S 4 SGP 0025176 TAPERED EDGE: BEVELED EDGE TAPERED n ROUND EDGE Georgia-Pacific round edge (RE) gypsumboard can be used for wall and ceilings in both new construction and remodeling. It is designed to reduce the beading and ridg ing problems commonly associated with standard type gypsumboard. This edge for mation provides a stronger, more rigid joint and reduces joint beading or ridging. EDGE Georgia-Pacific's "tongue and groove" edge is used on 2' wide sheathing and backer boards. SQUARE EDGE: MODIFIED BEVELED EDGE: The gypsumboard square edge was the original wallboard edge. Initially designed to be a base with a final covering such as wallpaper, paneling, or tile, square edge can be finished with joint compounds to form a clean monothic wall suitable for paint. Also can be used where an exposed joint is desired. The modified beveled edge is available only on EternawalfM panels. This particular edge more readily accommodates the vinyl sur face decoration, which is delivered com pletely edge wrapped. The vinyl surface material is available in 15 standard patterns and colors and 15 new colors and textures. JOINT SYSTEM PRODUCTS G-P Joint System products are designed to conceal joints and nail heads and ``surface-weld'' gypsumboard panels together. Properly used, these products assure smooth, seam- less appearance of walls and ceilings, with joints stronger than the gypsumboard itself, G-P BEDDING COMPOUND Bedding Compound is designed to provide maximum adhesion of tape to the joints and for initial application to nail heads and corner bead. It spreads smoothly and may be hand or machine applied. Coverage: 15 lbs. per 1,000 sq. ft. (Used in conjunction with 45 lbs. of Topping Compound.) 25 1b. bags. G-P Topping Compound is specifically designed for the second and third coats over the bedding compound. Since it is used only for topping, the amount of adhesive can be reduced and other materials incorporated which reduce the shrinkage and make it easier to sand and work. Coverage is approximately 45 lbs. per 1,000 square feet. Avail- able in 25 lb. bags, SGP 0025177 5 G-P TRIPLE DUTY ' JOINT COMPOUND G-P Triple Duty Gypsumboard Joint Compound is a vinyl multipurpose joint system product. A single bag offers tap ing, topping and texturing. It can be used for all coats in the reinforcing and concealing of joints in gypsumboard con struction. The binder, a vinyl, gives this product a wet life of 30 to 60 days duration. This allows premixing in large quantities prior to application. Triple Duty can be G-P READY M!X JOINT COMPOUND Ready Mix Joint Compound is an easy-working material for embedding the joint reinforcing tape and the filling and fin ishing of joints in gypsumboard construction. Furnished in cans and cartons ready to use, this stable, all-purpose compound is also excellent for use in covering nail heads and forming interior and exterior angles. Ready Mix Joint Compound assures a standard mixture for uniform worka- G-P ALL PURPOSE JOINT COMPOUND G-P All Purpose Joint Compound is used for bedding tape, topping, corner bead, nail spotting and texturing. When taping be sure the compound under the tape, and the first coat over the tape is thoroughly dry before applying the next coat over the joints. When used for texturing, for best re- G-P SPEED SET"" G-P Speed Set Joint Compound makes possible the taping and finishing of all gypsumboard joints within a single day. It can be used for all coats. Speed Set is a setting rather than a drying type of compound, and will not shrink once it A/ALL TEXTURES-- G-P Wall Texture is an unaggregated texture compound for hand tool or spray application. When applied with a spray, a splatter or orange peel texture is formed. When applied by hand, a stipple, swirl, or brocade texture can be produced. G-P Wall Texture can be applied immediately after G-P Ceil- CEILING TEXTURES G-P Ceiling Textures are designed for spray application over ceilings constructed with gypsumboard or concrete. The resulting texture simulates acoustical texture finish. Vermiculite--A 40 lb. bag of this aggregate is available in 3 particle sizes (fine, medium and coarse). An ideal prod uct for concealing surface defects. Coverage: 200-300 sq. ft. per bag. Texture samples available on request. Polystyrene--A new powder product in a 32 lb. bag. This rich white texture finish has strong adhesion with maximum G-P GRAB!'" G-P Grabit is an adhesive which permits direct attachment of gypsumboard to masonry walls. It may be used on poured concrete, cinder block or concrete block walls which are reasonably straight and true and are free from surface treatment, decorations, or protrusions. Grabit may be used on exterior walls which are above grade level with out waterproofing. Grabit can be used to adhere gypsum board to polystyrene insulation material. Adhesion is secure and permanent, with no need for furring strips or fasteners. After being mixed with water as directed, G-P GYPSUMBOARD TAPE G-P Tape is a full 2" width, "Miracle Crease" spark per forated tape with skived edges and sanded surface both 6 applied using standard hand or mechanical tools. There is low shrinkage and it is easily sanded. When the applica tion is completed, the surface is ready for priming and decoration as desired with no further preparation neces sary. Coverage: 60 lbs. per 1,000 sq. ft. 25 and 50 lb. bags. Can be used as a Texture. Coverage: 12-50 lbs. per 1,000 sq. ft. bility throughout the job. It has a long wet life and will not spoil even when the container is left open. Ready Mix Joint Compound produces an excellent surface for any type of decoration. For best results, the surface should be primed before being decorated. Coverage: 5 gal. per 1,000 sq. ft. Package--1 and 5 gal. cans, 4 gal. cartons. suits, apply a vinyl primer to the entire area before texturing. The texture may be applied with a roller, sponge, brush or can be sprayed, depending on the type of configuration desired. Coverage: 60 lbs. per 1,000 sq. ft. 25 lb. bag and packaged 18 lbs. of compound plus 250' roll of tape. has set. Comes in two ways--"1 Hour Working Time" and "2 Hour Working Time". For best results, use a primer sealer over surface before painting or texturing. 25 lb. bags. ing overspray wipedown. It is made for fast, volume applica tion. Because of its formulation, G-P Wall Texture matches G-P Ceiling Textures, and allows them to blend together. Coverage: 12-50 lbs. per 1,000 sq. ft. depending upon texture. 25 Lb. Package. coverage and excellent hiding qualities. The fragments of this very rough texture retain their size and shape during mechanical mixing. Coverage: 200-300 sq. ft. per bag. Especially designed for volume operations, these products give unsurpassed economy. The texture dries harder and tighter. The texture maintains a high quality white decora tive finish, and gives exceptional coverage if used as in structed. Grabit can be applied with blade or caulking gun. Only four 1" ribbons are needed for each 4' wide gypsumboard panel. The adhesive fills in all normal irregularities in the masonry. In 3 to 4 hours, Grabit sets hard, and joint taping and finish ing operations may then be started. This adhesive may be used wherever there is need to attach gypsumboard to ma sonry walls: in homes, apartments, hotels, offices, and plants. Coverage: Up to % lb. per sq. ft. depending on roughness of base surface. 50 Lb. Package. sides. Excellent bonding qualities. Stabilized against shrink age and movement. SGP 0025178 U. S. and Canadian Specification Directory Gypsumboard Products GeorgiaFfecific ^ PRODUCT G-P REGULAF* GYPSUMBOARD Tapered Edge Square, Tapered or Round Edge G-P INSULATING GYPSUMBOARD Square, Tapered Edge or Round Edge G-P ETERNAWALLTM Modified Beveled Edge THICK NESS 94" r %" %" %" Vz" 94" Vz" 94" G-P FIRESTOP GYPSUMBOARD Square, Tapered Edge or Round Edge G-P FIRESTOP INSULATING GYPSUMBOARD Square, Tapered Edge or Round Edge 94" 94" Vz" 94" WIDTH 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' 4' LENGTH ASTM & CSA STANDARDS | C 36 6' to 12' 6' to 16' 6' to 16' 6' to 16' 6'to 16' | C 36 6'to 15' 6'to 16' 1 C 36 8' Std.f 8' Std.f \ ' 6' to 16' J 6'to 16' 6' to 16' | 6' to 16' C 36 C 36 USA FEDERAL SPECIFICATION APPLIED UNDER SS-L-30c Type Ill-Grade R 3/20/67 ANSI A97.1 SS-L-30C Type Ill-Grade R 3/20/67 SS-L-30C Type Ill-Grade R or Grade X Class III 3/20/67 SS-L-30c Type Ill-Grade X 3/20/67 SS-L-30C Type Ill-Grade X 3/20/67 ANSI A97.1 ANSI A97.1 ANSI A97.1 ANSI A97.1 G-P TILE BACKER BOARD Tapered Edge Vz" 4' 8', 11' 94" 4' and 12' C 630 - - G-P GYPSUM SOUND DEADENING BOARD Square Edge 94" 4' 8' Std.f C442 SS-L-30C Type IV--Grade R G-P BACKER BOARD Square orT&G Edge 94" 4' 8' Std.f | C 442 94" 2' 8' Std.f 5/s" 2' 8' Std.f SS-L-30C Type IV Grade R Grade X G-P FIRESTOIP GYPSUM SHEATHING Long-Edges - Square Edge Core-treated or non core-treated Tongue a id Groove Core-treated or non core-treated Vz" 4' 8'&9' 94" 2' 8' Std.f C 79 1 ) SS-L-30C > Type II C 79 1 l Grade R&W - - G-P DENS-COTE BASE G-P FIRESTOP DENS-COTE BASE G-P DENS-COTE PLASTER 94" 94" 94" BRAND G-P G-P PRODUCT JOINT SYSTEM MATERIALS METRO-MIXTM G-P FORM BOARD f standard Length-Other Lengths on Order. Alt astm standards--Per Latest Revision. aii Canadian standards in Blue 4' 6' to 12' C 588 - 4' 6' to 12' C 588 C 587 - - ASTM* STANDARDS C 475 FEDERAL SPEC. SS-J-570a 10/24/66 APPLIED UNDER ANSI A97.1 0317 ANSI A59.1 Type V C318 SS-L-30C ANSI A59.1 Grade R Any questions not answered by the information on this page or available from local sources should be referred to Georgia-Pacific, Gypsum Division, 900 S.W. Fifth, Portland, Oregon 97204. SGP 0025179 7 Gypsumboard Nails & Screws Selector Guide Oescription Applications HV GWB-54 Annular Ring Nail 12"^ ga.; with a slight taper to a small fillet at shank. Bright finish; med. diamond pt. V2", Vt" and Vi" Gypsum board, V2" and %'r Gypsum Backer Board to wood frame 14V Annular Ring Nail (Same as GWB-54 except for length) Va" Gypsumboard to wood frame 2W 7d Nail 13 ga,, 1/4" diamond head 3>- Vs" Firestop* Gypsumboard face layers over V2" Sound Deadening Board or 2 layers Vi" Firestop to Wood Studs lVa" 6d Nail 13 ga., W diamr-d head Vb" and V4" Gypsumboard over existing surface, wood frame l7/a" 6d N il 13 ga., V4" diamc j head Vb" Firestop Gypsumboard to wood frame >> Gypsumboard to Metal Framing Gypsumboard to Wood Framing lVb" 5d Nj I 13J/2 ga., `%4" diar ond head V2" Firestop Gypsumboard to wood frame lVb" Matching Color Head Nail (Steel) V/e" Matching Color Head Nail (Steel) Predecorted Gypsumboard; to wood frame over exist ing surface, wood frame lVb" Matching Color Head Nail (Brass) Predecorated Gypsumboard (colors) to wood frame 1" Gypsumboard Screw Type S Single Layer Gypsumboard to 25 gauge Steel Studs. Gypsumboard to Resilient Channel. Gypsumboard to Metal Furring. l>/4" Gypsumboard Screw Type S lVb" Gypsumboard Screw Type S 1" core units to L Runner in 2" Solid and Semi-Solid Partition Systems. lVb" Gypsumboard Screw Type S Double-Layer Gypsumboard to 25 gauge Steel Studs. Double-Layer Gypsumboard to Metal Furring. l7/e" Gypsumboard Screw Double-Layer Gypsumboard. Type S 1" Gypsur >oard Screw Type S-12 Also available in lVb" & 1FV' lengths For single or multi-layer application of Gypsum board to heavy gauge steel (up to 12 gauge). 11/4" Gypsumboard Screw Single Layer Gypsumboard Type W to Wood Framing. Gypsumboard to G%ypSsuXm&tRSib&sfXf&Ssr- IV2" Gypsumboard Screw Type G lVb" Gypsumboard Screw Type G Gypsumboard to Gypsum Ribs in Semi-Solid Partition Systems. Wood Trim to Metal Framing lVb' Gypsumboard Screw Type S Trim Head 2V4 "Gypsumboard Screw Type S Trim Head Wood trim over single layer of Gypsumboard on 25 gauge Steel Studs. Wood trim over double layer Gypsumboard on 25 gauge Steel Studs. Metal Studs to Door Frames and Runners l! BSC Vfc" Gypsumboard Screw S-12 Pan-Head Metal Door frame to 12 gauge (max.) Steel Studs. Metal Studs to Metal Runners. Metal Trim & Door Hinges 7/a " Type S-18 Oval Head Door hinges to door frame to jiletal Framing Also available in 4V, and aluminum components toacxxcoo 1 Va" & lVi," lengths to metal. Horizontal and Vertical Application: TYPE S AND G--Metal studs or furring spaced 24" on center. Screws should be spaced 12" on center unless otherwise noted in the detailed assemblies shown in Georgia-Pacific literature. TYPE W--Wood studs 16" or 24" on center. Screws should be spaced 12" on center unless otherwise noted in the detailed assemblies shown in GeorgiaPacific literature. Selection of the proper nail for each application is extremely important, par ticularly for fire-rated constructions. The nails recommended comply with per formance standards adopted by the Gypsum Association. 8 Technical Data: Walls, Columns, Floor/Ceiling Construction and G-P Gypsumboard or Dens-Cote Veneer Plaster Systems. The following tables are summaries only, based on tests at Underwriters' Lab., National Bureau of Standards, (Jniv. of Calif., Ohio State Univ., Geiger and Hamme, Riverbank Lab. and/or Ohio Research Corp. spon sored by the G-P Gypsum Division, Gypsum Association, or others. Fire rating, weight, and sound characteristics are based on a combination of specific details as tested and published. Where carpet and pad is used in sound tests, carpet is 44 oz. and pad 40 oz. weights. All systems are ranked by STC number in each category. *Many of these are new numbers assigned by Underwriters' Laboratories (old numbers are in parentheses). COST INDEX BASIS: For wocd and gyp.um partitions, 100 is for 2x4 studs, 16" o.c., W Regular Gypsumboard each side. For metal stud partitions, 100 is for 21/2" studs, 24" o.c., %" Firestop each side. Other assemblies are rated against those two. Allow for local differences in labor and material costs. FIRE HAZARD (FLAME SPREAD) CLASSIFICATION: Official Underwriters' Tests. i/2" and %" G-P Firestop, 10-15 (Labeled); V2" and %" G-P, 10-15 (Not Labeled). More complete listings and details are avail able. Inconsistencies in test results are due to tests over a period of many years and variations in laboratory facilities. 1. STC under sound characteristics is Sound Transmission Class. 2. Official Underwriters' Tests have proven joint finishing is not required for the rating in assemblies of Firestop. 3. Under "Building Code Approvals" (A) refers to International Confer ence of Building Officials; (B) refers to Southern Building Code Con gress; (C) refers to Building Officials Conference of America. Addi tional approvals requested. Check with local building officials for verification of approvals as may be required. 4. Not all code jurisdictions belong to Model Code Groups. Therefore, we advise consultation with local building officials if acceptance of these test results are in doubt. Combustible Assemblies-For all 45 minute and 1 hour ratings %" struc tural interior plywood or particleboard underlayment grade, over build ing paper, over V2" structural interior plywood with exterior glue CD grade may be used over the wood joists with ceilings as detailed. Non-combustible Assemblies--Ceilings for all 1 hour, l1/ hour and 2 hour incombustible floor and ceiling construction assemblies with 2" or ll/i" concrete floor on metal lath over steel bar joints, unless otherwise speci fied, may be directly attached or suspended. G-P Firestop is listed by Underwriters and carries the UL Label for 45 minutes, 1, 2 and 3 hour Fire Resistance in various designs and with a Fire Hazard Classification of Flame spread 15, fuel contributed 15, smoke developed 0. SOUND CHARACTERISTICS--References: Geiger and Hamme, Inc.; Riverbank Labs; Kodaras. More complete listings and details are available. Inconsistences in test results are due to tests over a period of many years and variations in laboratory facilities. SGP 0025180 TECHNICAL DATA Walls and Column Construction G-P gypsumboard or Dens-Cote" veneer plaster system FIRE RESIST. 6-P STST. # RATING TEST* REFER. SOUND TRANS. STC TEST REFER. COST INDEX PART. THICK NESS WEIGHT AND SO. FT. .v V 8- 3 A C N 8 ; 3 c s -- ^ c -i, o 080 20 min. EST 31 EST 90 4*4" 5.2 Georgiafacific ^ CONSTRUCTION WALL SURFACE REFERENCES BLDG. DETAIL CODE INFO APP PAGE %" G-P Gypsumboard Both Sides -- 082 30 min. EST 32 EST 100 4%" 5.9 %" G-P Gypsumboard Both Sides ABC - 084 45 min. U.L.1 32 EST 110 W 5.9 V2" G-P Firestop Both Sides BC - 086 I hr. U. 501 34 OR-64-8 (U.L. 5) 087 1 hr. U. 501 34 OR-64-8 (U.L. 5) 092 11/2 hr. EST 37 CR-64-11 115 434" 125 434" 135 5y4" 7.0 7.0 9.5 094 1 hr. G.A. 38 EST 135 4%" 8.2 096 li/2 hr. G.A. 39 NBS 140 5%" 9.9 % " G-P Firestop Both Sides Basic 1 Hr. Fire Rated Wall G-P Tile Backer Board Both Sides %" G-P Firestop, 1 Layer, One Side, 2 Layers Other Side %" G-P Gypsumboard, 2 Layers, Both Sides 1/2" G-P Gypsumboard, 2 Layers, Both Sides ABC 16 ABC -AC- 098 2 hrs. T-194 41 0R-64-12 160 5%" 12.0 % " G-P Firestop, 2 Layers, Both Sides ABC 16 MOOD DA3"r'~'0NS Gvosum Sound Leadening Board 3 'uds--2 c IB1 5 : 100 1 hr. U. 312 45 BW-27-FT 145 4%" (U.L 30) 7.96 1/2" G-P Firestop, 1 Layer Strip Laminated Over %" Gypsum Sound Deadening Board, 2 Sides ABC 16 102 1 hr. U. 312 47 BW-28-ST 160 5V4" (U.L. 30) 8.3 %" G-P Firestop, 1 Layer Laminated over J4" Gypsum Sound Deadening Board, Both Sides ABC 16 G-P Firestop, 1 Layer Over % " Sound 104 1 hr. EST 47 BW-29-ST 175 67/g" 8.79 Deadening Board, Both Sides Laminated, Staggered Studs 106 1 hr. U. 312 50 (U.L. 30) BW-35 175 5%" 8.7 %" G-P Firestop, 1 Layer Strip Laminated over Gypsum Sound Deadening Board, 2 Sides, 2" Insulation 1/2" G-P Firestop, 1 Layer over V4" 105 1 hr. EST 52 BW-30-ST 190 6%" 8.92 Gypsum Sound Deadening Board, 2 Sides, 2" Insulation, Staggered Studs 108 1 hr. EST 50 BW-31-ST 225 10" 1/2" G-P Firestop, 1 Layer Laminated over 9.14 lk" Gypsum Sound Deadening Board, Both Sides, Double Studs 1/2" G-P Firestop, 1 Layer Laminated over 109 1 hr. EST 55 BW-32-ST 240 10" 9.29 1/4" Gypsum Sound Deadening Board, 2 Sides, 2" Insulation, Double Studs . ABC 17 . ABC 17 __ 17 See Page 8 For Notes SGP 0025181 9 FIRE RESIST. SOUND TRANS. 6*P SYST. ! RATING *1 TEST* REFER. STC TEST REFER. WOOD ST JDS Resilient Channels COST INDEX 112 1 hr. T-3127 44 OR-64-7 135 PART. THICK NESS 5i/8 WEIGHT AND SQ. FT. 6.3 CONSTRUCTION WALL SURFACE %" G-P Firestop, 1 Layer Nailed 1 Side, 1 Layer on Resilient furring other side 114 iy2 hr. EST 48 OR-64-15 155 5%" 8.8 WOOD ST'JDS Resilient Channels Insulating Blankets 116 1 hr. T-3127 50 OR-64-16 150 5i/s" 6.4 %" G-P Firestop, 2 Layer 1 Side, 1 Layer on Resilient furring other side % " G-P Firestop, 1 Layer Nailed 1 Side, 1 Layer on Resilient furring other side, plus fiberglass insulation in stud space STAGGERED STUD WALLS 150 li/2 hr. EST 43 OR-OO-O 175 W 11.0 %" G-P Regular, 2 layers, Both Sides 152 2 hrs. EST 47 TL-69-210 190 W 12.7 Based on 154 1 hr. U. 501 48 (U.L. 5) DOUBLE WOOD S~'JDS EST 140 6%" 7.0 170 1 hr. EST 46 EST 215 7.5 175 2 hrs. WP297 FM 57 ~ RAL - 11 Vs" - WOOD STUDS ciber Sound Board 118 1 hr. T-3006 46 OR-64-73 165 5%" EXTERIOR WALLS 500 2 hrs. U302 (U.L. 23) 50 See Page 8 For Notes EST 5%" LO CO %" G-P Firestop, 2 layers, Both Sides s/8" Firestop, 1 layer each side, 2x6 plate, 2" insulation 5/s" Firestop, 1 layer each side double row of studs 1" apart on separate 2x4 plates, insulation in stud space V2" G-P Firestop Gypsumboard, 2 layers face each side of wall, 1 layer attached to each stud inside, with 1" space between inside layers Lot Line Wall 5/8" G-P Firestop, 1 layer over y2" Fiber Sound Deadening Board, Both Sides %" G-P Firestop, 2 layers interior, i/2" Gypsum Sheathing, 2'x8" T&G Brick Wall Exterior REFERENCES BLDG. DETAIL CODE INFO APP PAGE ABC 17 - 18 ABC 18 -ABC ABC - ---- - 18 ABC 18 ABC SGP 0025182 10 G-P SYST. # FIRE RESIST. RATING TEST REFER. SOUND TRANS. STC TEST REFER. COST INDEX PART. THICK NESS WEIGHT AND SQ. FT. Georgia-Pacific ^ CONSTRUCTION WALL SURFACE REFERENCES BLDG. DETAIL CODE INFO APP PAGE 240 1 hr. U510 35 BW-8-FT 75 (U.L. 10) 2Va" 242 1 hr. EST 51 OR-65-19 125 4%" 244 1 hr. T-3128 51 OR-64-57 150 43/4" 7.2 7.2 7.9 % " G-P Firestop, 1 layer each side, height limit 12 ft. based on L/120, 5 lbs. PSF Yi" G-P Firestop, 1 layer 1 side, other side screwed to resilient channels plus 2" fiberglass insul. in stud space 5/s" G-P Firestop, 1 layer over y2" G-P Sound Deadening Board, both sides ABC - ABC - 230 2 hrs. G.A. 36 G.A. 90 2" 8.1 232 2 hrs. G.A. 36 G.A. 95 2" 8.1 234 2 hrs. EST 37 G.A. 100 2Va" 9.1 1/2" G-P Firestop, 1 Layer Each Side, 1" Coreboard, height limit 9 ft. based on L/120 5 lbs. PSF i/2" G-P Gypsumboard, 1 Layer Each Side, 1" Coreboard, height limit 9 ft. based on L/120, 5 lbs. PSF 5/s" G-P Firestop, 1 Layer Each Side, 1" Coreboard ' 9-.AI3 ;apc ^AP'-'OVS >o-- cs-e v.:-.::; 224 2 hrs. U502 35 TR-57-42 (U.L. 7) 4" 13.4 1/2" G-P Firestop, 2 Layers Each Side, 1" Rib Coreboard 222 3 hrs. U501 40 TR-57-43 (U.L. 5) 5" 13.4 Yi" G-P Firestop, 2 Layers Each Side, 1" Rib Coreboard 200 2 hrs. T-2575 47 OR-64-39 - 6" 13 i/2" G-P Gypsumboard over 1" Coreboard Each Side of3" airspace APS 19 ABC - -- ABC ABC ABC 19 204 3 hrs. EST 51 OR-64-58 - 6" 17 202 3 hrs. EST 57 OR-64-59 - 6" 17.2 206 2 hrs. T-4958 - 2 hrs. 208 Chase T-4991 Wall - 210 iy2 hr. T-4982 - See Page 8 For Notes - - 2%" 10.5 - 73/4" 9.0 - 2y4" 8.4 1/2" G-P Gypsumboard, 1 Layer over 1" Coreboard both side of 3" air space with 1" Coreboard Yi "G-P Gypsumboard, 1 Layer over 1" Coreb'd. Each side of 3" airspace with 1" Coreb'd centered in air space and fiberglass insulation in space on 1 side. -- 19 G-P 1 Yt" core unit plus two face layer y2" G-P regular screw-laminated, track and vertical "T" splines G-P 1 %" core unit, angle runners, 23/2" metal studs, one facing layer of %" Firestop screwed to studs G-P 1%" core unit, plus face layer 5/s'' Firestop screw-laminated. Track and vertical "T" splines on 24" centers ---- SGP 0025183 ii FIRE RESIST. SOUND TRANS. S-P SYST. # RATING TEST REFER. STC TEST REFER. COST INDEX METAL STUDS INSULATING BLANKETS PART. THICK NESS WEIGHT AND SQ. FT. 328 1 hr. T-5316 41 OR-66-5 110 3%" 4.3 CONSTRUCTION WALL SURFACE REFERENCES BLDG. CODE ARP DETAIL INFO PAGE i/2" G-P Firestop, 1 layer each side, 2" fiberglass insul. in stud space, 2y2" studs, 24" o.c. - 19 300 1 hr. T-2316 44 OR-64-81 115 2% " 0.0 316 1 hr. T-4848 48 OR-66-6 125 5%" 7.0 330 1 hr. T-2316 48 OR-64-80 145 3%" 7.2 5/8" G-P Firestop, plus 2" fiberglass insul. in stud space, 1%" studs i/2" G-P Firestop, 1 layer 1 side, y2" regular G-P Gypsumboard, 2 layers other side (insulation in cavity for STC), 35/8" studs ABC 20 - 22 %" G-P Firestop, 1 layer 1 side, 2 layers other side ABC 2" fiberglass insul. in stud space, 1%" studs - 334 1 hr. EST 48 0R-66-6 130 4" 6.3 14" G-P Firestop, 1 layer 1 side, 2 layers other side plus 2" fiberglass insul. in stud space, 2y2" studs - 310 2 hrs. T-3218 48 BW-12-FT 155 4V2" 8.0 318 iy2 hrs. T-3126 50 OR-64-51 150 5V2" 8.0 i/2" G-P Firestop, 2 layers each side, STC based on ABC 21 2" insul. in stud space, 2y2" studs %" G-P Firestop, 1 layer 1 side, 2 layer other side plus 3" fiberglass insul. in stud space, 3%" studs _ 22 324 2 hrs. T-2557 52 OR-64-50 170 6%" 11.1 %" G-P Firestop, 2 layers both sides plus 2" fiberglass in stud space, 3%" studs ABC 23 METAL STUDS GYPSUM SOUND DEADENING BOARD 304 1 hr. U410 45 BW-16-FT 130 4" (U.L. 32) 7.0 %" G-P Firestop, 1 layer, laminated over S.D. ABC 20 Board, both sides screw attached, 2y2" studs 306 1 hr. U410 (U.L. 32) 50 BW-17-FT 140 4" 308 1 hr. U410 (U.L. 32) 54 BW-18-FT 145 4%" 7.12 8.12 y2" G-P Firestop, both sides 1 layer, laminated to *4" S.D. Board, screw attached, 2" fiberglass friction fit in stud space, 2y2" studs %" G-P Firestop, both sides, 1 layer laminated to % " S.D. Boards, screw attached, 2" fiberglass friction fit in stud space, 2y2" studs ABC 20 ABC 21 METAL STUDS FIBERBOARD SOUND DEADENING BOARD 320 1 hr. EST 44 OR-65-10 125 5%" 5.75 %" G-P Firestop, 1 layer 1 side, other side, 1 layer over y2" fiber S.D. Board, 3%" studs - 22 336 1 hr. EST 49 0R-65-11 135 5%" - %" G-P Firestop, 1 layer over y2" fiber S.D. Board, both sides 3%" studs -- STEEL STUD CHASE WAlL (l " Metal Studs 24' o.c --6 x '2 --'< Gypsur.ooarG Spacers: 326 1 hr. EST 47 BW-335T - IVi" 6.69 1/2" G-P Firestop, 1 layer laminated over S.D. ABC 23 Board, both sides 327 1 hr. EST 52 BW-345T - 71/2" 6.84 12 i/2" G-P Firestop, 1 layer laminated over y4" S.D. ABC Board both sides, plus 2" insul. in stud space SGP 0025184 See Page 8 for Notes Georgia-Fbcific ^ FIRE RESIST. G-P SYST. # RATING TEST REFER. VE~'_ S'"- 340 35 min. EST SOUND TRANS. STC TEST REFER. COST INDEX 35 OR-65-2 90 PART. THICK NESS WEIGHT AND $Q. FT. w- i 302 1 hr. T-2316 35 j TL-62-72 95 i m" 342 1 hr. T-2898 35 OR-64-65 130 33/4" 5.2 - 344 1 hr. T-2069 39 OR-63-1 100 33/4" - CONSTRUCTION WALL SURFACE 3/2" G-PGypsumboard, 1 layer each side, 23/2 " studs Yz" G-P Firestop*, 1 layer each side, 1 Yz" studs Yz" G-P Firestop, EternawallTM, 1 layer each side, lYi studs Yz" G-P Firestop, 1 layer each side, 23/2" studs REFERENCES BLDG. DETAIL CODE INFO APP PAGE -ABC 20 ABC - ABC - 346 1 hr. T-2016 42 OR-63-11 105 4 %" 312 hr. EST 43 OR-63-2 135 4 H" 6.0 7.5 313 IV2 hr. EST 43 OR-64-32 140 5%" 8.0 314 2 hr. T-2557 46 EST 150 5" 10.4 Yz" G-P Firestop, 1 layer each side, 3%" studs ABC - Yz" G-P Firestop, 1 layer 1 side, 2 layers other side, - 21 21/2" studs Yz" G-P Firestop, 1 layer 1 side, 2 layers other side, 3Yz" studs - 21 Yz" G-P Firestop, 2 layers, 2 sides, 23/2" studs ABC 21 322 2 hr. T-2557 47 OR-64-52 - 350 2 hr. T-2406 47 EST - STEEL COLUMN ":P = ?? EC^NG - 1 hr. G.A. - - - 1 hr. EST - - - 11/2 hr. G.A. - - - 2 hr. X520 (U.L. 20) - 2 hr. X517 - (U.L. 8) - - 3 hr. X513 - (U.L. 39) -- 3 hr. X509 -- (U.L. 18) -- - 4 hr. X501 (U.L. 26) See Page 8 For Notes - - - - - -- - 6y8" 11.0 6*4" 10.4 Yz" G-P Firestop, 2 layers, 2 sides, 35/8" studs Yz" G-P Firestop, 2 layers, 2 sides (face layer-- Eternawall), 35/8" studs ABC 22 ABC - --- -- -- -- 3/2" G-P Gypsumboard, 2 layers Yz" G-P Firestop, 1 layer 3/2" G-P Gypsumboard, 3 layers 1/2" G-P Firestop, 1 layer 5/3" G-P Firestop, 2 layers -- AB -- -- ABC - -- 3/2" G-P Firestop, 2 layers -- ; Yz" G-P Firestop, 3 layers i - ! Yt" G-P Firestop, 4 layers ABC -- ABC - SGP 0025185 13 SOUND CONTROL & FIRE RESISTANCE TECHNICAL DATA 6-P SYST. * WEIGHT LB./ SQ. FT. SOUND RATING FIRE RESISTANCE RATING | TEST REF. i RATING TEST REFT WOOD jO!StS -6'' c.c. finished floor cn rough sub-floor, except as noted ...... 400 Vs" G-P Regular, 1 layer ---- -- 1 1 15 min. -- BLDG. OETAIl CODE INFO APP. PAGE ABC -- 401 Vz" G-P Regular, 1 layer 11.4 -- -- 25 min. -- ABC -- 402 Vz" G-P Firestop-, 1 layer applied to metal furring channel 16" o.c. with 1" x 6" T. & G. subflooring, 1 layer of resin building paper, and 1" x 4" T. & G. finished flooring -- STC 47 TL64-155 1 hr. L502 (UL-33) ABC 23 403 Vz" G-P Firestop, 1 layer 11.4 -- -- 45 min. U.L. No. 1 AB -- 404 G-P Firestop attached to resilient metal furring 24" o.c. with Vs" plywood subfloor and carpet and pad -- STC 48, L-224- INR + 18 3&4 1 hr. EST. ABC 24 405 Vs" G-P Firestop, 1 layer 12.0 STC, 38, INR- 16, (EST.) 1 hr. L501 AB -- (U.L. No. 1) 406 Vi" G-P Firestop, 1 layer attached to 2" x 8" joists 16" o.c. and 2" x 4" joists 16" o.c. Vz" plywood subfloor attached to 2" x 8" joists 16" o.c. with rug and pad, 3" insulation in cavity -- 407 Vi" G-P Firestop, 1 layer nailed; 2nd layer Vs" Firestop 16.0 applied to resilient furring channel 24" o.c. between layers STC 51/ INR + 29 -- KAL-22414+15 -- 1 hr. ~ 24 2 hr. L505 ABC j -- (U.L. No. 217) 408 Vi" G-P Firestop, nailed, lVs" lightweight concrete, Vi" -- STC 53/ L-224- 1 hr. EST. A-- plywood, wood joists, 16" o.c., insulation, resilient INR+ 23 27 & 28 furring, carpet and pad 409 Vz" G-P Firestop, 1 layef nailed 13.0 -- -- 1 hr. L503 ABC -- (U.L. No. 46) 411 Vi" G-P Regular, 2 layers 413 Vz" G-P Regular, 2 layers -- i -- -- -- -- 30 min. -- 1 hr. EST. EST. ---- ---- 415 Vz" G-P Firestop, 1 layer, laminated and nailed to W G-P -- STC 41/ BW-2MT 1 hr. EST. A 23 Gypsum Sound Deadening Board, with floor of Vs" CD INR+ 25 plywood, Vz" particleboard underlayment, carpet and pad 417 Vi" G-P Firestop, 1 layer laminated and nailed to lA" G-P -- STC 42/ Gypsum Sound Deadening Board with floor Vs" CD INR+ 25 plywood, Vz" particleboard underlayment, carpet and pad (EST.) 1 hr. 420 Vz" G-P Firestop, 1 layer screwed to resilient channel 24" -- STC 53/ OC 3-MT j 1 hr. o.c., Vs" plywood subfloor with Vs" particleboard over INR + 22 wood joists 16" o.c., 3" insulation, carpet and pad EST. ABC -- FC 181 (FM) -- 24 1 422 Vs" G-P Firestop, nailed, 15/s" lightweight concrete, Vs" plywood, wood joists 16" o.c., insulation, carpet and pad See Page 8 for Notes 14 -- STC 47/ L-224- 1 hr. INR + 15 29 & 30 EST. A -- SGP 0025186 Georgia-Ffecific ^ 5 0UNC G-P SYST. n '.i " WEIGHT LB./ SO. FT. SOUND RATING RATING TEST REF. FIRE RESISTANCE RATING TEST REF.* BLDG. OETAIl CODE INFO APP. PAGE 475 Vb" G-P Firestop, 1 layer attached to resilient channel 16" o.c., %" T. & G. plywood subfloor over 2" x 10" joists 24" o.c. STC 50 1 EST. i 1 hr. 1 _______ _______ U.L.L513 24 410 Vz" G-P Firestop, one layer over Vz" Sound Deadening Board (direct attached) 6.5 _ ~ :i = "' - ~ " ; \,i 421 W G-P Firestop nailed or screwed to metal furring 16" o.c. 423 Vb" G-P Firestop Backer, nailed or screwed to metal furring 16" o.c. 425 Vb" G-P Firestop, 1 layer, metal furring 24" o.c. 34.2 -- 34.2 -- 32.0 -- 427 Vz" G-P Firestop, metal furring 24" o.c. 33.9 -- 429 Vb" G-P Firestop, metal furring 24" o.c. 431 Vb" G-P Firestop, metal deck 24" o.c. 36.4 -- 37.0 -- 2'z ' C 0 N C P z :0 3 ON V! S" A L L A" -> ;/=.- 5 -* a . : s s 2 440 Vz" G-P Firestop, metal furring 24" o.c. 38.5 -- 442 Vb" G-P Firestop, metal furring 24" o.c. 39.3 -- -- ! 1 hr. U.L. No. 47 A _ 11 -- 1 hr. U.L. No. 2 ABC -- -- 1 hr. U.L. No. 2 ABC -- ___________ -- 1 hr. G501 ABC -- (U.L. No. 19) -- lVz hr. G502 ABC -- (U.L. No. 17) -- 2 hr. G505 ABC -- (U.L. No. 259) -- 2 hr. U.L. File ABC -- R4024-12 - *c 5<T>b'J3tioi3 -- 2 hr. G504 ABC -- (U.L. No. 237) -- 2 hr. U.L. No. 69 ABC -- 450 Vb" G-P Firestop, 18" deep combination steel-wood -- STC 47/ L-224- 1 hr. joists 32" o.c., 3" insulation, resilient furring, carpet and INR + 18 35 & 36 pad, Wb" plywood subfloor 452 Vb" G-P Firestop, 18" deep combination steel-wood joists 16" o.c., 3" insulation, Vb" plywood, lightweight concrete deck, carpet and pad -- STC 46/ L-224- 1 hr. INR + 11 37 & 38 ; T '. ",......... ' -- Vb" G-P Firestop, two layers ---- -- 2 hr. 'Many of these are new numbers assigned by Underwriters' Laboratories. (Old numbers are in parentheses.) SGP 0025187 EST. -- -- EST. N501.N502 -- -- (U.L. No. 254, 255) See Page 8 for Notes 15 SYSTEM INSTALLATION DETAILS %' G-D C;PES"'C ~ ; LAVE'. rC'H SIDES BASIC 1 HR. FIRE RATED WALL) ~086 STC/41 SOUND TEST OR-6 -12 FIRE RATING/2 HR COMBUSTIBLE FIRE TEST T-194 Materials Used 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. %" Firestop Type X Gypsumboard 4. 6d and 8d Nails 2 ' 3-P F:RES" .? ..... :V- -c SUi/! SOUND DEADENING BOARC STC/45 SOUND TEST G&H BW 27FT FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L. U312 (U.L. 30) Materials Used 1. 2" x 4" Wood Studs 11 ' o.c. 2. 2" x 4" Wood Plates 3. Vi" Gypsum Sound Deadening Board 4. Vi" Firestop Type XXX Gypsum board or Firestop Eternawall!M 5. 5d cc Nails 6. 4d Finish 7. G-P Joint Compound G-P VF-EL`M SOUND DEADENING BOARD STC/47 SOUND TEST G&H BW 28FT FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L. U312 (U.L. 30) Materials Used 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. Vi" Gypsum Sound Deadening Board 4. % " Firestop Type X Gypsumboard or Firestop Eternawall,M 5. Joint Compound 6. 4d Finishing Nails 7. 5d Nails 16 'iC SGP 0025188 Georgia-Fbcific G-P FIRE3T0P LAMINATED TC 3Y=3UM SOUND DEADENING 30ARD STC/47 STC/52 WITH INSULATION SOUND TEST G&H BW 29ST/G&H BW 30ST FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Used 1. 2" x 4" Wood Studs staggered 8'' o.c. on opposite sides of 2" x 6'' Wood Plate 2. 2" x 6" Wood Plate 3. Va " G-P Gypsum Sound Deadening Board 4. Vi " G-P Firestop Type XXX or Firestop EternawallTM 5. G-P Joint Compound 6. 4d Finishing Nails and 4d Common Nails 7. 5d Common Nails 8. 2" Insulation Batts (on BW-30ST for STC/52) .A ' E ~ STC/50 SOUND TEST G&h l W 35FT FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L. U312 (U.L. 30) Materials Used 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. Va " Gypsum Sound Deadening Board 4. % " Firestop Type X Gypsumboard or Firestop EternawallrM 5. Joint Compound 6. 4d Finishing Nails 7. 5d Nails 8. 2" Insulation Batts. VT'ri :p M A' ND DEADE,N!>i STC/50 STC/55 WITH INSULATION SOUND TEST G&H BW 31ST/G&H BW 32ST FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Used 1. 2" x 4" Wood Studs (d uble row) 16" o.c. 2. 2" x 4" Wood Plates--V apart 3. Va " G-P Gypsum Sound Deadening Board 4. Vi " G-P Firestop Type XXX or Firestop EternawallTM 5. 4d Finishing Nails, 4d Nails 6. 5d Nails 7. G-P Joint Compound 8. 2" Insulation Batts (on BW 32ST with insulation for STC/55) G - ? r ' E E c no ;N P- ; = N" li N -' STC/44 SOUND TEST OR-64-7 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST T-3127 Materials Used 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. % " Firestop Type X Gypsumboard 4. Resilient Channels 5. 1 Va " Type W Gypsumboard Screws 6. 1" Type S Gypsumboard Screws 5/8" FIRESTOP 2x4 WOOD STUDS RESILIENT METAL FURRING CHANNELS 1/2" GYPSUM FILLER STRIP. 2x4 WOOD PLATE ^ SGP 0025189 17 5't" G-P FIRESTDP- 2 LAYERS 1 1S*ID* E* 1 LAYER ON RESILIENT CHANNEL OTHER SIDE STC/48 SOUND TEST OR-64-15 FIRE RATING/1 % HR. COMBUSTIBLE/EST. Materials Used 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. %" Firestop Type X Gypsumboard 4. Resilient Channels 5. 1 %" Type W Gypsumboard Screws 6. 1" Type S Gypsumboard Screws G-P FIRES^OF- ON RESILIENT CHANNEL WITH INSULATION IN CAVITY STC/50 SOUND TEST OR-64-16 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST T-3127 Materials Used 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. %" Firestop Type X Gypsumboard 4. 2" Insulation 5. Donn DG-8 Resilient Channels 6. 1V* " Type W Gypsumboard Screws 7. 1" Type S Gypsumboard Screws H" 3-D c!RES"0D OVER FIE ER SOUND DEADENING BOARD 2 SIDES STC/46 SOUND TEST OR-64-73 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST T-3006 Materials Used 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. 2" x 4" Wood Fire Blocks 4. Vt" Fiber Sound Deadening Board 5. % " Firestop Type X Gypsumboard 6. 5d Cement Coated Nails and 8d Box Nails 7. Laminating or Joint Compound -P FIP:] LAVERS ON FACE. 1 oA^ER INSIDE. BCTH SIDES STC/57 STC/59 WITH INSULATION SOUND TEST R.A.L. FIRE RATING/2 HR. COMBUSTIBLE FIRE TEST FM WP-297 Materials Used 1. 2" x 4" Wood Studs 24" o.c. 2. Fireblocks--2" x 4" x 22V2" 3. V2 " Firestop Type X Gypsumboard 4. 8d Coated Box Nails 5. 6d Coated Box Nails 6. 6d Nails 7. 12d Common Nails 1/2" GYPSUM FIRESTOP 2x4 WOOD STUDS 2x4 WOOD PLATES 18 l<D>, SGP 0025190 "iPE3T= ' / EP EiC - 3.CE 3VE-' Georgia-Ffecific ^ SGP 0025191 19 S'B" G-P FIRESTOP' 1 LAYER EACH SIDE 2 G-P FiRESTOP' 1 2.AYER OVER U' GYPSUM SOUND DEADENING EC /-' : EACH SIDE STC/45 SOUND TEST BW16FT FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST T-3854 & U410 (U.L. 32) Materials Used 1. 21/2 " Steel Studs, 24" o.c. 2. 2V4 " G-P Steel Track 3. '/*" Gypsum Sound Deadening Board 4. 1" Type S Gypsumboard Screws 5. Vz " Firestop Type XXX Gypsuirv board or Firestop EternawallTM 6. 1 % " Type S Gypsumboard Screws '/2 G-P FIRESTOP OVER V2' GYPSUM SOUND DEADENiNG BOARD WTn -\S-_LATlON iN DA * 1 STC/50 SOUND TEST BW17FT FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST ULU410 Materials Used 1. 2V2" G-P Steel Studs, 24" o.c. 2. 2Vz" G-P Steel Track 3. 2" Insulation 4. 'A " G-P Gypsum Sound Deadening Board 5. 1" G-P TypeS Gypsumboard Screws 6. y2" G-P Firestop Type XXX Gypsumboard or Firestop EternawallTM 7. 1%" G-P Type S Gypsumboard Screws SGP 0025192 20 Georgia-Ffecific ^ v," G-P FIRESTOP' OVER Y," GYPSUM SOUND DEADENING BOARD W^w INSULATION IN CAVITy STC/54 SOUND TEST BW18FT FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST ULU410 Materials Used 1. 2'h " G-P Steel Studs, 24" o.c, 2. 2'h " G-P Steel Track 3. 2" Insulation 4. 'A " G-P Gypsum Sound Deadening Board 5. 1" G-P Type S Gypsumboard Screws 6. 5/e" G-P Firestop Type "X" Gypsumboard or Firestop Eternawalf"1 7. 1*3/4a1"2G-P Type S Gypsumboard Screws -103 V' G-P FIRESTOP , 2 LAYERS 2 SIDES WITH INSULATION IN CAVITY STC/48 SOUND TEST BW 12FT FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST T-3218 (fiberglass insulation not required for fire rating) Materials Used 1. 2V2" Steel Studs, 24" o.c. 2. 2V2 " Floor and Ceiling Tracks 3. 'h " Firestop Type XXX Gypsum- board 4. 2" Insulation 5. Laminating or Joint Compound 6. 1" and 1 3/a " Type S Gypsumboard Screws Y, " G-P FIRESTOP'. 1 LAYER 1 SIDE, 2 LAYERS OTHER SIDE STC/43 SOUND TEST OR-63-2 FIRE RATING/1 V2 HR. NON-COMBUSTIBLE/EST. Materials Used 1. 21/2" Steel Studs, 24" o.c. 2. 2'/2 " Floor and Ceiling Track 3. Vs" Firestop Type X Gypsumboard 4. 1" and 15/s" Type S Gypsumboard Screws 'V' G-P FIRESTOP . 2 LAYERS 2 SIDES STC/46 EST. FIRE RATING/2 HR. NON-COMBUSTIBLE/EST. FIRE TEST T-2557 Materials Used 1. 2'h'' Steel Studs, 24" o.c. 2. 2'h" Floor and Ceiling Track 3. 5/a" Firestop, 2 layers each side 4. 1" & 1 % " Type S Screws 2 LAYERS 5/8" FIRESTOP 2 Vz'' STEEL STUDS 2'/!" FLOOR AND CEILING TRACK SGP 0025193 21 y2" G-P FIRESTOP". 1 LAYER 1 SIDE. y2 " G-P REGULAR. 1 _.VE~$ C~- STC/48 EST. FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST T-4848 Materials Used 1. 3% " Steel Studs, 24" o.c. 2. 3%" Track 3. Vi " Firestop Type XXX Gypsum- board 4. Vi " Regular Gypsumboard, 2 Layers 5. 2" Insulation (not required for fire rating) 6. 1" and 1%" Type S Screws 5/e" G-P FiRESTOP". 2 LAYERS 1 SIDE, 1 LAYER OTHER 1 STC/50 SOUND TEST OR-64-51 FIRE RATING/1 y2 HR. NON-COMBUSTIBLE FIRE TEST T-3126 Materials Used 1. 3% " Steel Studs, 24" o.c. 2. 3% " Floor and Ceiling Track 3. %" Firestop Type X Gypsum- board 4. 3" Insulation 5. Laminating Compound 6. 1" and VM" Type S Gypsumboard Screws /i - K s/8" G-P FIRESTOP". 1 LAYER 1 SIDE. 1 LAYER OVER 2" r'BEP . 5: / - STC/44 SOUND TEST OR-65-10 FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST T-2557 Materials Used 1. 3%" Steel Studs, 24" o.c. 2. 3%" Floor and Ceiling Track 3. Vi" Fiber Sound Deadening Board 4. Laminating Compound 5. % " Firestop Type X Gypsumboard 6. 1" and 1% " Type S Gypsumboard Screws Vb" G-P FIRESTOP", 2 LAYERS 2 SIDES STC/47 SOUND TEST OR 64-52 FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST T-2557 Materials Used 1. 3%" Steel Studs, 24" o.c. 2. 3% " Floor and Ceiling Track 3. Laminating Compound 4. 5/e" Firestop Type X Gypsum board 5. 1" and 1%" Type S Gypsumboard Screws Vh "STEEL STUDS 5/8" FIRESTOP 3W" FLOOR AND CEILING TRACKS 22 SGP 0025194 5/, ' Q.p "*1 2p3=43T0P , 2 LA/EPS 2 SIDES WITH INSULATION IN CAVIT'/ STC/52 SOUND TEST OR-64-50 FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST T-2557 Materials Used 1. 35/a " Steel Studs, 24" o.c. 2. 35/8" Floor and Ceiling Track 3. Vs" Firestop5Type X Gypsum- board 4. 2" Insulation 5. Laminating or Joint Compound 6. 1" and 1%" Type S Gypsumboard Screws 5-3 3;q r : 2VHP GVP3UM SOUND DEADENING SOAPD STC/47 STC/52 WITH INSULATION* SOUND TESTS: BW-33ST/BW 34ST FIRE RATING/1 HR. NON-COMBUSTIBLE Materials Used 1. IVs" Steel Studs, 24" o.c. 2. 1 Vs " Floor and Ceiling Track 3. V* " G-P V* " Gypsum Sound Deadening Board 4. Vs " Firestop Type XXX Gypsum board or Firestop Eternawall'"1 5. 1 % " Type S Gypsumboard Screws System if327 6. 1 Vi " Type S Gypsumboard Screws 7. Vs" x 6" x 12" Gypsumboard Spacers 8. 2" Insulating Batts (on BW-34ST for 52 STC) Georgia-Ffecific GYP3UV1 SOUND DE ADEN'NG 30APD STC/41 INR + 25 (WITH CARPET & PAD) SOUND TEST G&H BW 2-MT FIRE RATING/1 HR. COMBUSTIBLE EST. BASED ON L 503 (U.L. 46) Materials Used 1. 2" x 10" Wood Joists 2. Carpet and Pad 3. Vs" Particleboard Undertayment 4. Vs" CD Grade Plywood Subfloor 5. Vi " G-P Gypsum Sound Deadening Board 6. Vs" G-P Firestop Type XXX Gypsumboard 7. 4d Ring Shank Nails; 6d Common Nails; 8d Common Nalls 's ` G-P F'RESTOP ON RESILIENT METAL FURRING 'FLOOR CEILING STC/47 SOUND TEST TL 64-155 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST L502 (U.L 33) Materials Used 1. 2" x 10" Wood Joists 2. Rosin Building Paper 3. 1" x 6" Tongue and Groove Subflooring 4. 1" x 4" Tongue and Groove Finished Flooring 5. Donn DG-8 Resilient Channels 6. Vs " Firestop Type XXX Gypsum board 7. 1" Type S Gypsumboard Screws and 8d Nails ^ 22 4 .122 SGP 0025195 23 STC/48 SOUND TEST L-224-4 FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Used 1. 2" x 8" Wood Joists--16"o.c. 2. %" Plywood 3. 44 oz. Wool Carpet 4. 40 oz. All Hair Pad 5. 3" Insulation 6. Resilient Channels 7. Yb " G-P Firestop Type X Gypsumboard 8. 8d Nails 9. 1" and 1'A" Gypsumboard Screws STC/51 INR + 29 SOUND TESTS: KAL-224-14, KAL-224-15 FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Used 1. 2" x 8" Wood Joists 2. Vi" Plywood 3. 44 oz. Wool Carpet 4. 40 oz. All Hair Pad 5. 8d Nails 6. 2" x 4" Joists 7. 3" Insulation 8. % " G-P Firestop Type X Gypsumboard STC/53, INR+ 22 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST FC 181 (FM) Materials Used 1. 2" x 10" Wood Joists 2. % " Plywood Subflooring 3. % " Particleboard 4. 1'A "Nails 5. 8d Nails 6. Vz" Firestop Type XXX 7. Resilient Channel 8. 8d Nails 9. 1" Gypsumboard Screws 10. 3Vz" Insulation 11. Carpet and Pad STC/50/EST., IIC/70/EST. (WITH CARPET & PAD) FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L. L513 Materials Used 1. z%2" T. & G. Plywood 2. Elastomeric Adhesive 3. %" Gypsumboard Strips 4. 2" x 10" Wood Joists 5. Resilient Furring Channels 6. %" Firestop Type X 5/8" FIRESTOP GYPSUMBOARD 24 SGP 0025196 GeorgiaFfecific Vz" Firestop--2 Hr. Rating-- Incombustible, Floor/Ceiling 2" SAND-GRAVEL CONCRETE Denswall Texturing Products Georgia-Pacific offers 4 basic textures. All are dry i products and contain a tested balance of aggregate duce the effect you want. The coverage, however, w with different types of surfaces, spray equipment, manship, and customer requirements. Wall Texture Wall Texture packaged in a 25 lb. bag has no aggr G-P's wall texture may be applied with spray equi: large wall brush, roller, or trowel. Wall Texture is white" and matches all G-P ceiling textures. This p offers a hard durable surface, good hiding properties, mum coverage, and is easily worked. U.L. Design G505 (UL259)--2 Hr. (with 2" concrete) G-P produces lighter weight board and better fire resist ance! %" Firestop Gypsumboard reinforced with glass fibers covers many ratings listed by Underwriters' Labora tories for the %" thick material. This means that G-P fire-rated board can be used in most kinds of wall, floor and ceiling assemblies. The 10% reduction in weight can result in savings in labor and materials in multiple story construction. Concrete Floor - Metal Lath Steel Bar Ceiling Texture (Vermiculite) Ceiling Texture packaged in a 40 lb. bag contains ve ulite aggregate and is available in either fine, mt or coarse textures. Vermiculite aggregate offers an a tical finish appearance for ceilings but does not pr acoustical sound correction. The use of this product re in a "high white," rugged texture with semi-rounded and valleys" that help conceal surface defects while ducing a beautiful, decorative textured ceiling. Ceiling Texture (Polystyrene) Ceiling Texture packaged in a 32 lb. bag. Polystyrene ture is designed for fast, economical spray applies The resultant texture is "high white," with strong s sion. This product offers maximum coverage and exce hiding qualities. Polystyrene aggregate is a plastic ! which is shredded into coarse angular particles that duce an extremely rough texture. These aggregate tides will retain their size and shape during long per of mechanical mixing. An ideal product for volume s application. All 3 DenswallTM texture products from G-P are designer spray application over ceilings constructed with gyps board or concrete and will produce a simulated acousr texture finish. UL Design G505 attachment details Texture Wall Texture Vermiculite Ceiling Texture Polystyrene Ceiling Texture Finish Bag Siae Water Mix* St 25 lb. Add 2V4 Gallons Remix Do not exceed 3% Gallons Average Coverage Gypsumboard j Con Spray : 1,000 sq. ft. j Trowel : 200 sq. ft. : FM 40 lb. Add Do not Spray 3( & ct 3V4 Gallons exceed 400 sq. ft. I sq. 5 Gallons ct 32 lb. Add Do not Spray ; 3C 6 Gallons exceed 400 sq. ft. j sq. 8 Gallons 'Mix until dry powder is wetted and well dispersed. Th allow to soak for 20 minutes. Remix and adjust to desir consistency. If desired, up to IVz gallons of compatible water bas paint may be added, per bag, to impart color. tS--Smooth (no aggregate) F--Fine M--Medium C--Coarse Installation Details Application of Rigid Predecorated Panels to Gypsum Substrate Use %" or Vi" gypsumboard. Attach to studs with 13/b" gypsumboard nails, 1" gypsumboard screws (metal studs) or drywall stud adhesive. Joints need not be taped or sealed. Install the gypsumboard vertically with the edges centered on the framing members. The rigid predecorated panels should be applied using a bead of panel adhesive over each stud. Secure paneling at top and bottom plates with 4d. finishing nails 12" o.c. Field fasteners not required unless panels are bowed. The addition of gypsumboard as a substrate when using predecorated panels provides increased FIRE RESISTANCE and SOUND CONTROL. Application Over Masonry Walls On masonry walls either above or below grade, be sure the wall is properly waterproofed before furring is applied. Although moisture barrier gypsumboards are available-- there is obviously no substitute for proper waterproofing. Wood Strips or Metal Channels: Apply furring horizontally or vertically. Space 16" o.c. for Va" and %" gypsumboard, and 24" o.c. for Vi" and 5/a" gypsumboard. Use concrete stub nails or power driven fasteners to install furring. Gyp sumboard should be applied perpendicular to furring. Use Georgia-Pacific insulating Gypsumboard. Test Results Paneling (No Gypsum) Burn thru Time Better Sound Rating Better Impact Resistance 8 min. 28 STC 26 Paneling With %" Gypsum 42 min. 40 STC 82 Paneling With Vi" Gypsum 73 min. (plus) 40 STC 82 Georgia-Pacific GrabitTM, a Masonry Adhesive: Apply 1" ribbons of Grabit to each edge and 16" o.c. in field of back of each piece of gypsumboard. Be sure surface to be cov ered is reasonably straight, and free of fragments of mortar or other protrusions. The adhesive fills in irregularties in the masonry surface. Grabit may also be used to apply gyp sumboard to polystyrene insulation material that has been used against the masonry. Grabit may be used without wa terproofing on exterior walls which are above grade. Tem porary fasteners or bracing may be necessary until Grabit sets. SGP 0025198 26 GeorgiaFfecific 4^ Water Resistant Gypsumboard G-P Tile Backer Board is a water-resistant gypsum product with a light blue face paper, designed for use as a base for the adhesive application of ceramic, metal or plastic tile. The gypsum core consists of incombustible gypsum rock, combined with an emulsion giving high water resistance. This new G-P product is ideal for bathrooms, kitchens, powder rooms and all high moisture areas. For fire rated partitions between bathrooms or interior areas subject to moisture use 5/e" Firestop Tile Backer proven by Underwriters' Laboratories in a 1-hour assembly over wood studs. The raw edges of Tile Backer Board (end joints, cut edges, cut-outs) are to be caulked with a coating of the waterproof compound used in applying the tile. As an alternate to caulking, G-P can provide a special 214" wide self-adher ing vinyl tape to place over edges and cut-outs. Solid and Semi-Solid Gypsum Partitions Partition systems composed entirely of gypsumboard have the added values of increased fire resistance and max imum use of space. In the following four systems the common factor in each is that they are all constructed (except for floor ceiling run ners) entirely of gypsum incombustible materials. 2" Solid Laminated-- (Non-Load Bearing) A 1" gypsum coreboard with Vz ` gypsumboard laminateo to each side; no air space. A 2" solid wall system has a 2 hour fire rating, an STC rating of 35, produces smooth monolithic walls and creates extra usable floor space. 2" Solid Laminated Floor and Ceiling Details For fire and sound rated construction the Tile Backer Board must extend to the floor. j ' Rat taping j i '' 1 to ce<hng ...ITT? fiberglass ': or other non combustible resilient I '! material [ Caulkng Concrete nail or power shcf fastener CONCRETE CEILING i Wood trim -/Vh [\ (Optional) kri : 1--1, ; CONCRETE CEILING Homogenous j or laminated j | ;l | Vinyl trim -- i (Optional) 1 Caulking - ' Caulking WOOD FLOOR DETAIL CONCRETE FLOOR DETAIL 2V4" Semi-Solid Laminated Gypsumboard 214" Semi-Solid Laminated--(Non-Load Bearing)--A cen ter vertical rib (or stud) composed of 2 layers of laminated gypsumboard (1" x 6" rib, 24" o.c.) is the base upon which s/b" gypsumboard is laminated to each side. This leaves intermittent 1" dead spaces for wiring. The 214" system has a 1 hour fire rating, money saving simplicity of installation, a 30 decibel STC, creates smooth walls and provides extra floor space. Double Solid Laminated-- (Non-Load Bearing) Consists of laminating Vz" gypsumboard to a T tongue and groove coreboard homogenous or laminated on each side of a 3" air space. There is absolutely no connection over the air space except at the jambs. This system has a 2 hour fire rating, greater strength than standard frame or thin solid wall, a 47 decibel STC and produces smooth wall surface. Triple Solid Laminated- sgp 0025199 (Non-Load Bearing) The center piece is a 1" gypsum core panel running the height and length of wall, on one side of which is dead space the other side is filled with fiberglass insulation. Outer sec tion of wall (on both sides) is Vz" gypsumboard laminated to 1" coreboard (this gives a IV2'' wall on both sides of center section). This system has a three hour fire rating, a 57 decibel STC and produces smooth monolithic walls. 27 Wood and Steel Stud Application There are many different kinds of construction systems and all are based on the requirements of your particular build ing installation. Basically, the main considerations are us ually: Fire Resistance, Sound Transmission, Relative Strength of the Installation, Dimensional Restrictions and Economy. After the wall and floor/ceiling constructions have been selected, it is important that they be installed properly. The following precautions should be taken during installation to avoid situations or conditions which will detract from the sound control properties of the assembly: Avoid connecting plenum chambers, ducts, vents, etc. These permit the unrestricted flow of sound. Corrective measures are to make partitions full height, and use ducts lined with absorbent material. Materials: All gypsumboard shall be G-P Gypsumboard V2" or 5/e" thick Regular or Firestop, 4' wide x ceiling height for vertical application or up to 16' long for hori zontal application, tapered edge. All joint treatment prod ucts are to be G-P materials. Framing: Piior to the gypsumboard application, all framing members should be true and firmly fastened in a plane sur face. Provide double studs at all corners. Both inside and outside intersections are formed by extending one edge of a panel over the other edge in a flush position and covering with tape and joint treatment. In single ply installation, all ends and joints of gypsumboard shall occur over fram ing members, except that this is not required for treated joints at right angles to framing members. Application: Gypsumboard may be applied horizontally or vertically to framing with nails or screws. (Alternate meth od-stud adhesive may be applied to studs before applying gypsumboard.) The gypsumboard shall be attached with nails meeting ASTM-C514 or with VA" long G-P Type "W" gypsumboard screws or 1" long G-P type "S" Gypsum board screws, for wood and metal or framing respectively. SINGLE PLY GYPSUMBOARD MAXIMUM FRAMING SPACING Gypsumboard Thickness Application %" sidewalls.................................... Horizontal or Vertical 16" o.c. 1/2 " sidewalls................................ _. .Horizontal or Vertical 24" o.c. y8" sidewalls.................................... Horizontal or Vertical 24" o.c. Vi" ceilings................................ Parallel or Perpendicular 16" o.c. s/s" ceilings ...................... Parallel or Perpendicular 16" or 24" o.c. NOTE: If heavy spray texture or other heavy finish is applied to the ceiling, do not install gypsumboard parallel to joists. NAILING OR SCREW SPACING FOR SINGLE-PLY GYPSUMBOARD (Framing 16" o.c.) Gypsumboard Thickness Single Nailing Double Nailing %" sidewalls...................... 8" o.c. Max......................12" o.c. Max. Vi" sidewalls...................... 8" o.c. Max......................12" o.c. Max. %" sidewalls...................... 8" o.c. Max......................12" o.c. Max. ceilings........................ 7" o.c. Max......................12" o.c. Max. Framing 16" o.c. Framing 24" o.c. Gypsumboard Thickness Screw Spacing Screw Spacing % " sidewalls.................... 16" o.c. Max....................... -- Vi sidewalls..................... 16" o.c. Max......................12" o.c. Max. 5/b " sidewalls..................... 16" o.c. Max......................12" o.c. Max. ceilings...................... 12" o. c. Max......................12" o.c. Max. NOTE: Nails or screws should be driven not less than %" from edges or ends of panels. While fasteners are being driven, the gypsumboard shall be held in firm contact with the underlying supports. Preferably, application of fasteners should proceed from the central portion of the gypsumboard to the ends and edge. Dimple nails or screws without breaking the face paper. Joints: All joints should be taped and finished with tape and joint compound, nail or screw heads should be finished with joint compound. Ex terior angles are covered with G-P Metal Casing Beads and finished with joint compound. 28 Column Fireproofing Fireproofing with G-P Firestop Gypsumboard provides a fast, efficient and economical method of protecting steel columns. Fire resistant assemblies of two, three and four hours are obtainable depending upon the number of layers of %" or Vz" G-P Firestop used. These layers are held in place by a combination of screws and metal studs. The two, three and four hour fire rated assemblies of Firestop have passed Official Fire Tests conducted by the Underwriters' Laboratories. Fire Resistance--For three hour protection, two layers of V2" Firestop Type XXX c: be used. Test No. X513 (UL 39-3 hour). Two hour protection can be obtained using 1 layer of 1/2" Firestop Type XXX. Test No. X520 (UL 20-2 hour). These are for heavyweight columns (14 W.F. 228). For lightweight columns (10 W.F. 49) use 4 layers of s/a" G-P Firestop Type X f 4 hour protection, 3 layers for 3 hours. Test No. X509 (I . 18) and 2 layers for 2 hour, Test No. 517 (UL 8). Lighter--As compared . other types of fireproofing, a dead load saving of from 50 0 75% can be realized with G-P Firestop Column Firepr. ofing. Speed of Erection--G-P Firestop Gypsumboard can be installed quickly and easily when used for column fire proofing following G-P details. Minimum amount of the wire and adhesives are used. ILLUSTRATION--THREE-FOUR fire rated steel column assembly with 5/e" Firestop. X509 (UL 18). Minimum size of column W10X49. ILLUSTRATION--TWO HOUR fire rated steel column assembly with 5/e" Firestop. X517 (UL 8). Minimum size of column W10X49. SGP 0025200 Shaft Liner GeorgiaFfecific ^ Gypsumboard Enclosure Systems Description Georgia-Pacific Shaft LinerTM is a gypsumboard partition for enclosing elevator shafts, stairs, smoke towers and other vertical openings. It is a non-load bearing wall, designed for resistance to uniform wind loads without excess deflection. Important advantages of the system are: t. Much lighter weight than masonry. 2. Non-combustible. 3. Economical. 4. Can be completely erected from one side. 5. Practically eliminates the need for scaffolding. 6. Non-progressive system; panels can be individually re moved for backside maintenance (prior to face layer applicatio ). 7. Minimum ean-up. 8. Full length panels not required (can be spliced). 9. Sound anc ire rated. 10. Cavity anc solid types available. The partition consists of a basic pre-laminated panel 1 s/e" thick by 24" wide, which fits into a top metal "J" and bot tom "L" runner. Metal "T" splines are inserted between each panel. The panels are subsequently secured to the "T" splines, and top and bottom runners. Installation of the facing layers and/or channel and surface finishing can be accomplished later to coincide with interior partitions. This system meets the ASTM El 19 requirements for 1 and 2 Hour Fire Resistive Classifications. It is also designed and tested to meet a variety of wind loads at various heights (see chart on page E/31). The standard gauge of the metal components is 20 gauge. Furring channel used in the cavity wall is 25 gauge. The G-P Shaft Liner System is designed for versatile per formance. Ease of construction from one side also makes this wall ideal for use in other vertical openings (such as stairwells). The "T" splines in the back side can be covered by erecting a layer of gypsumboard first before screw attaching the Shaft Liner panels to the metal components. The UL tested systems may be spliced vertically for ease of handling or greater heights. The facing consists of layers of Vz" or %" G-P Gypsum board. The exposed layer may be Dens-Cote Base and Dens-Cote Veneer Plaster, or G-P Tile Backer. 2 Hour Wall (Basic) Fire Rated Both Sides 2 Hour Fire Rated Cavity Wall Fire Rated Both Sides Installation Basic 2 Hour System (UL U503) STC 40 (EST) #5000 Install the perimeter framing first. This consists of the top metal "J" and bottom "L" tracks. These components are to be secured with power driven fasteners, or equivalent, at 24" maximum centers. The 1%" Shaft Liner panels are in serted top first into the "J" track and pushed flush against the bottom angle runner. The "L" track and IV2'' metal strip may be substituted for the "J" track at the top. These panels are separated by the "T" splines which are positioned so the flat, or flange, side faces the shaft. Type S-12 drill point screws 2"-23/s'' long are used, 24" o.c. to fasten the panel to the "T" splines. At the extreme top and bottom, screw the core to the runners, at points 2" on each side of the spline, using the drill point screws. Screws will protrude slightly on the unfinished shaft side. To splice core panels, use 2' section of "T" spline at all horizontal butt joints. Stagger butt joints a minimum of 24 '. Two layers of %" Georgia-Pacific Firestop Gypsumboard 4' wide by wall height are then applied to the face side. Each is installed parallel to the Shaft LinerTM panels. The first layer is offset from the "T" spline by 12", and the second layer staggered 24" from the first. Installation is by %" beads of adhesive or applying Georgia-Pacific Ready-Mix Joint Compound in strips with a gun. For improved sound reduction, adhesive or compound should fill the joints at each "T" spline. Caulk around perimeter of panel. The fac ing sheets are also secured with V/z "-15/s" type G screws spaced 24" o.c. at edges and center (1st layer) and 16" o.c. at edges and center (2nd layer). Finish joints and screw heads in normal manner in preparation for the final deco ration. 2 Hour Cavity Wall System (UL U514) STC 47 #6000 Install the perimeter and 15/e" core unit as instructed in the basic 2 hour system. Install 25 gauge furring channel ver tically to face of panels spaced 24" o.c., and offset 12" from "T" splines. Fasten channels with V/z" type G screws 24" o.c. each side and at extreme top with 2%" type S-12 screws. Two layers of Vz" Firestop Gypsumboard are then installed vertically and screw attached to the furring channel. The joints of first layer of gypsumboard should fall on channel and be fastened with 1" type S screws 12" o.c. along edges and 16" o.c. on intermediate channels. Stagger joints of SGP 0025201 29 second layer 24" from first and fasten with 15A6" type S screws 12" o.c. along edges and intermediate channels. Tape and finish joints. For STC 47 rating, #6000, install 1" fiberglass insulation* vertically between channels. For STC 48, #6250, install insulation* and 2 face layers of 5/b" Firestop Gypsumboard, use IV2" screws. For STC 50, #6500, install insulation* and 3 layers of %" Firestop Gypsumboard. 2 Hour Chase Wall (O.S.U. T-4991) #8000 After erecting metal components and 15/s" panel, attach G-P "L" angle runner horizontally at levels approximately 40" apart through core unit into "T" spline. Erect 2Vz", 25 gauge steel studs and track a minimum of 3" from core unit. Brace studs with angle runner. Apply one layer of 5/a" Firestop to studs. See page E/33 for details. Alternate 2 Hour System (O.S.U. T-4958) STC 39 #2000 Install framing and 15/s'' Shaft Liner panels in same manner as described for the Basic 2 Hour Wall (UL U503). Two layers of regular V2" Georma-Pacific Regular Gypsum board, 4' wide by partition he ,ht are applied to the face side. Each is installed parallel to the Shaft Liner panels. Proceed with the application 0 these facing layers in the same manner as that for the B. "sic 2 Hour System (UL503). Alternate 2 Hour System (U511) STC 39 #3000 Same as above except facing layers are V2" G-P Firestop. m Hour Wall (O.S.U. T-4982) #1000 The "L", "J", and "T" components and the 15/a" panel are erected in the same manner as in the Basic 2 Hour System. The one layer of %" G-P Firestop is laminated to the panel and secured with G screws 16" o.c. and 1" S-12 screws at extreme top and bottom. Offset joints from "T" splines by 12". General Working Conditions During cold weather, temperatures in the building should be maintained at not less than 50F during application of acoustical sealants, adhesives, or joint treatment. There should be adequate ventilation to dispose of excessive moisture during these periods. For steel frame construction, installation of top track should be completed before application of any spray-on fireproof ing. The poured concrete floor should be reasonably smooth in the area where the track is to Id > installed. If the track is in stalled close to the edge, the concrete may spall unless a fastening plate is set into the concrete to which the track can then be applied.** The "T" spline and shaft liner panels should be no shorter than %" less than height of the shaft opening (floor to ceil ing). The "J" track can be used to eliminate top fastening of panels during initial placement. Working conditions of con tractor can determine choice of metal to be installed at top. The strip should be 22 gauge, IV2" wide and secured with 23/s " screws located 2" either side of "T" splines. ' 'When a separate plate is used it should be 12 gauge and the track may be attached with V2" S-12 No. 8 pan head screws 24 o.c. Precautions 1. Georgia-Pacific Shaft Liner walls are non-load bearing. 2. Do not use in areas of unusually high moisture condi tions. 3. Voids in solid walls created to accommodate mechanical piping, wiring, etc. should be filled with mineral fiber in sulation. As an alternate, furred construction may be used. 4. Provide control joints at maximum 30 ft. intervals. 5. When hand rails or other heavy items are anchored to the Shaft Liner System, install 20 gauge metal strip be tween the Shaft Liner panels and facing layers. 6. 1" side of 1 5/a " core panel must face shaft opening. *1" thick by 23" wide masonry or mobile home type insulation with di 30 G-P Shaft LinerTM System Soundt/Firett Tests SOUND TESTS BY GEIGER & HAMME System # Description-- Face Layers * STC 1000 Solid Wall--1 Layer %" G-P Firestop -- Fire Rating IVz Hr. 6000 Cavity Wall--2 Layers Vz" G-P Firestop 1" Insulation 6250 Cavity Wall--2 Layers G-P Firestop 1" Insulation 47 48 2 Hr. 2 Hr. 6500 Cavity Wall--3 Layers 1/2" G-P Firestop 49 EST. 2 Hr. 2000 Solid Wall--2 Layers V2" Regular Gypsumboard 39 2 Hr. 3000 Solid Wall--2 Layers V2" G-P Firestop 39 2 Hr. 7000 Cavity Wall--3 Layers %" G-P Firestop 1" Insulation 50 5000 Solid Wall--2 Layers s/a" G-P Firestop 40 EST. 3 Hr. 2 Hr. 5500 Solid Wall--3 Layers s/a" G-P Firestop 44 EST. 2 Hr. 2500 Solid wall---3 Layers 1/2" G-P Firestop 43 EST. 2 Hr. 8000 Chase Wall--1 Layer s/b" G-P Firestop tBased on ASTM E90 ttBased on ASTM El 19 39 EST. 2 Hr. of %# to 1# per cu. ft. SGP 0025202 Shaft Liner Height Selection Table Fire Test Shaft Side O.S.U. T-4982 Wall Thickness 21/4 " Allowable Deflection L = Wall Height L/120 L/240 Both Sides U.L. U514 31/2" L/120 L/240 Both Sides U.L. U514 33/4" L/120 L/240 Both Sides U.L. U514 4" L/120 L/240 Shaft Side O.S.U. T-4958 25/a " Shaft Side U.L. U511 25/8 " Both Sides Both Sides U.L. U514 U.L. U503 4% 2%" Both Sides U.L. U503 3 Vs" Shaft Side U.L. U511 Shaft Side O.S.U. T-4991 31/2" 25 ga. 21/2'' Stud 16ga. 35/e" Stud PRODUCT SPECIFICATIONS L/120 L/240 L/120 L/240 L/120 L/240 L/120 L/240 L/120 L/240 L/120 L/240 L/240 L/120 L/240 Georgia-Ffacific ^ LIMITING HEIGHT FOR UNIFORM LATERAL LOAD 5 psi 7.5 psi 10 psi 12.5 psi 15 psi CO Tf 11'4" 15' 10" 12' 7" 16' 5" 13'1" 17' 13' 6" 17' 5" 13' 10" 17' 5" 13' 10" 17' 9" 14'1" 19' 15'1" 20' 4" 16'2" 22' 17' 5" 14' 23' 18'3" to 0 CD <0 12'5' 13'10" 11' 14'4" 11'4" 14' 10" 11'9" 15' 2" 12' 1" 15' 2" 12' 1" 15'6" 12'4" 16' 8" 13' 2" 17' 9" 14'2" 19' 2" 15'3" 12' 20' 2" 16' 11'4" 9' 12'7" 10' 13' r 10'4" 13' 6" 10' 9" 13' 10" 10' 11" 13' 10" 10' 11" 14' 1" 11' 2" 15' 1" 12' 16' 2" 12' 10" 17'5" 13' 10" 10' 18'4" 14'6" p cn 10' 6" 8'5" 11'8" 9'3" 12' 1" 9' 7" ' 2 6" 9' 11" 12' 10" 10' 2" 12' 10" 10' 2" 13' 1" 14' 11'2" 15' 11' 11" 16' 2" 12' 10" 8' 17' 13'6" 9' 10" 7' 10" 11' 11' 4" 9' 11' 9" 9'4" 12' 1" 9' 7" 12' 1" 9' 7" 12' 4" 9'10" 13' 2" 10' 6" 14' 2" 11' 2" 15' 3" 12' 1" -- 16' 12' 8" Gypsumboard, Vz" and %" Gypsumboard, 1" Dens-Cote Base, Vz" and % Dens-Cote Veneer Plaster ASTM C 36 ASTM C442 ASTM C588 ASTM C587 Tile Backer Special Metal for Components Furring Channel (25 gauge) ASTM C630 ASTM C446 ASTM C645 SGP 0025203 31 1. INSTALLING FLOOR TRACK. 2. INSTALLING CORE PANEL. 3. ATTACHING CORE TO T-SPLINE. 4. APPLYING FINISH LAYERS. 32 Metal Components STC 39 STC 39 System #2000 STC 43 System #3000 2 H0UR WALL <AI-TERNATE> STC 40 CAULK AS REQUIRED 1 V2 ' METAL STRIP SCREW ATTACH G-P "L" 1H" SHAFT LINER PANEL METAL T SPLICE FOR EXTENOED HEIGHTS V FIRESTOP GYPSUMBOARD (2 LAYERS) G-P ANGLE RUNNER FLAT STRIP SCREW ATTACH CAULK AS REQUIRED 2 HOUR WALL (ALTERNATE) System #5000 STC 44 FIRE TEST U.L. U503 2 HOUR WALL (BASIC) Rated Both Sides System #2500 System #5500 FIRE TEST U L U503 SGP 0025205 STC 47 STC 50 1H" SHAFT LINER System #6000 STC 48 1H" SHAFT LINER 2 HOUR FIRE RATED CAVITY WALL RATED BOTH SIDES System #7000 STC 39 2 HOUR FIRE RATED CAVITY WALL RATED BOTH SIDES T SPLINE System #6250 STC 49 2 hour fire rated CAVITY WALL RATED BOTH SIDES FIRE TEST U L. U514 System #6500 34 2 hour fire rated CAVITY WALL RATED BOTH SIDES System #8000 FIRE TEST T-4991 3GP 0025206 Gypsumboard screws designed specifically for Shaft Liner systems 23/a" TYPE "S"-12 BUGLE HEAD 2" TYPE "S"-12 BUGLE HEAD %" TYPE "S"-12 PAN HEAD 2y2" TYPE "S" BUGLE HEAD 1 5/b" TYPE "S" BUGLE HEAD 1 yl6" TYPE "S" BUGLE HEAD r TYPE "S" BUGLE HEAD 1Yz" TYPE "G" BUGLE HEAD 35 Top Wall Intersection Bottom Corner corner bead End SGP 0025208 36 SGP 0025209 37 ETERNAWALL" Combines gypsumboard with the beauty of sheet vinyl These fire-resistant panels are factory laminated with a quality, washable vinyl sheet providing a permanent scuff, crack and chip-resistant surface. Colors are fade-resistant and the texture or design will not be impaired when cleaned. Eternawall panels are available in 12 standard colors and 3 simulated woodgrains plus 15 new vinyl surfaces, including 10 colors in G-P's Burlap texture, 2 colors in weave and 3 new woodgrains. The long edge is completely wrapped with vinyl and eased to form a modified beveled edge*. Georgia-Pacific Firestop EternawallTM is available for use when the wall construction requires the gypsumboard to be of fire rated construction. Firestop EternawallTM has a gypsumboard base contair ig greater glass fiber rein forcement and unexpanded ermiculite. Specifications All vinyl surfaced gypsumboard scheduled and/or indi cated on the drawings shall be Georgia-Pacific EternawallTM as manufactured by the Gypsum Division of Georgia-Pacific Corporation. The panel construction shall consist of sup ported or unsupported vinyl of "wall surfacing grade" fac tory laminated to G-P Regular or Firestop Gypsumboard. The long panel edges shall be a modified bevel and com pletely wrapped with vinyl. The colors and patterns shall be as selected from the EternawallTM Standard Line or spe cial new colors and textures. (See page 4 for colors.) PRODUCT DATA Thickness: 14", V2" and 5/e" Regular Gypsumboard, 1/2" and 5/a" Firestop Gypsumboard. V2" Regular Eterna- wallTM is the stock thickness. Standard sizes: 4' x 8' and 4' x 10'. Special lengths avail able upon request in one foot increments from 4' x 7' to 4' x 16'. Special sizes (length and width) available on special order basis. FIRE HAZARD CLASSIFICATION 14" and Vs" gypsumboard consisting of gypsum core, surfaced on both sides with paper or with a vinyl facing on one side. Fire Hazard Classification Basic Board With Vinyl Facing Flame Spread 15 25 Fuel Contributed 15 10 Smoke Developed 0 20-50 Classified by Underwriters' Laboratories, Inc. UL labeled Eternawall available. EDGE DETAIL Modified Beveled Edge Color coated stainless steel nails are available to match all Standard colors and woodgrains. Trim accessories are available in 8' x 10' lengths to match all standard colors and woodgrains. Matching moldings are available for the new EternawallTM colors and textures from Keller Products, Inc., 41 Union Street, Manchester, New Hampshire 03103. Snap-on type moldings are not available for the new special order colors. TRIM ACCESSORIES SGP 0025210 Snap-On Interior Trim SOUND CONTROL PARTITIONS--EternawallTM Surfaced. These fire and sound rated vinyl-surfaced gypsumboard systems eliminate the need for battens. G-P Firestop EternawallTM is laminated directly to G-P 14" incombustible Gypsum Sound Deadening Board. They are not only simple to install but they are inexpensive and provide a very du rable wall, and very high STC ratings. in BUILOING INSULATION Demountable Partitions Demountable wall systems are installed by using any of the appropriate or approved color-matched moldings. To lami nate to existing wall surfaces, use G-P Laminating Com pound and secure panels mechanically at top and bottom plates. Panels may be applied with adhesive directly to metal studs, wood framing or furring strips. For application directly to masonry walls, use G-P GrabitTM Masonry Adhesive. `Colors are listed on Page 4. Swatches are available in Sweets Design Catalog or by writing Georgia-Pacific Corporation, 900 S.W. Fifth, Portland, Oregon 97204. 38 Fire Test U.L. U312 Fire Rating--1 Hour Combustible STC 50 System *106 Fire Test U.L. U410 Fire Rating--1 Hour Incombustible STC 50 System *306 `Insulation not required for fire rating. Standard colors ***** "'XJ, - -v' y-.y* GeorgiaFtecific ^ Stucco GP-705 Willow Green GP-701 Snowdrift White GP-651 Buff GP-704 Tangerine GP-702 Cherry GP-681 Flax GP-688 Oak GP-697 Burnt Sugar GP-108 Shadow Beige GP-205 Tarnished Gold GP-111 srp 0025211