Document p24YEOzO1zVz8XLM2pb92x5ed
f
lfi] //
"
/
Avoid Oral Instruction
Date AS# J /SS^
l/
To MMZ. F/SfMAW# /)AfF //Air {3 scrs)
SotrtATr y/Aiyts -
70 f/J * 7fr# ft# fiMAMt/f# Mftf/MAnr /A/S7&90 Of
Arr&wfj____zs____&
MAty7?60 0f7F*rsAfjQv7S#S &/y sw
Jdr At*rs 77//S />*/ a^/e
li/j/i/) />/?//SS/s? - S2 A7^e* #/> 77?* Z//A/S &/T*f
y/fia;/fr;A/7S.______;________________________________________________-________________________________
_____________/Vz ft* t/A/ #1/
A&&TUX/P ..M77t. /tSS> /S&
tt/HfAj r'/o Mf .7-4 ttr Alt ygjae /d/Ssr-
ms// s7~ sa/ jv-
AM-686-A
fttAt/K$ &x. YM#
Signed
\/rcf dt*sum+
-
ucc
050929
ouyulgs / /lA,
S&etX'o pAJULM\^A^d^\
fljt Qd^aLp' ^ct&. tdc*-' /t#Ad$ Ct/K^fa-sfe -"'^^
ucc
050930
From the desk of:
SAM NORWOOD
UCC 050931
From the desk of:
SAM NORWOOD
_k
DN p. o. eox
X Ct^/7J<Ls
S<3,94^^
r Xl rfi--. J\ / d<J
March fU^ fg 1
^
/! St**
pAjLU*
Q&\&Lp' jOalg: tdLf'
/DaotXX^
:^ 4 VI (v#rrf"~
lGesnf\-- $(y*f
Method of Compliance with Part 61/ Vinyl Chloride Monomer Control/ 1 Chloride Strippers______________________
Several years ago a proposal was submitted to the TACB in Austin and the EPA in Dallas for consideration of a statistically-based control system for vinyl chloride monomer (VCM) in our Solution Vinyl Resins production unit at Texas City.1 This proposal was not acceptable to the EPA because it did not meet the daily monitoring requirements that the EPA considers vital to the degree of control desired for residual VCM under the terms of the regulation. An EPA document ^ was provided which suggested that a daily monitoring of process control parameters that would assure the required residual VCM levels could be attained would be a satisfactory alternative to the stripped sample analyses specified in the present regulation. Such a parameter monitoring program is the subject of this present request.
BACKGROUND INFORMATION
The Solution Vinyl Resins unit at the Texas City Plant of Union Carbide Corporation produces a series of copolymers of vinyl chloride/ vinyl acetate and other comonomers by unique solvent-based process technology. Because the major reactant in this copolymerization process is vinyl chloride monomer, the process unit is subject to Federal
1, 2 See References, page
ucc
050932
Mr. Cecil Bradford Mr. Allyn Daws March 29, 1984 Page 2
Government regulation under Part 61, National Emission Standards for Hazardous Air Pollutants (NESHAPS), Subparts A and F and Appendix B, Methods 106 and 107.
Accordingly, since the effective date of this regulation, we have been providing a semiannual report as prescribed by 61.70 of Subpart F. This report includes a record of the VCM content of polyvinyl chloride copolymer resins produced here and analyzed according to Method 107. The analytical data are reported as the daily weighted average VCM content of the dry copolymer resins calculated by the formula 61.70 (c)(2)(ii) and (c)(2)(v). According to 61.64 (e)(1)(ii) which specifies the emission standard for various polyvinyl chloride processes, specifically, for sources following the strippers, the maximum daily weighted average is 400 ppm, dry resin basis, for each type of resin produced.
From information published prior to the promulgation of this regulation for VCM control, we understood that the VCM stripping operation of primary concern involved the removal of unreacted VCM from Suspension, Bulk and Latex products. All three processes are characterized by having small solid resin particles present in dynamic equilibrium with unreacted VCM in the stripping steps of the processes. Because the physical mechanism of removal of VCM from solid particles in these three processes is highly dependent upon VCM diffusion properties and rates in the mixtures, the level of 400 ppm VCM was considered a stringent requirement, calling for considerable care and attention in these production facilities. As a result, the regulation was established with very stringent sampling and analytical procedures and requirements to be sure the processes were adequately controlled to meet the 400 ppm VCM limitation.
However, in the continuous stripping of VCM in the Solution Vinyls Process from the autoclave product solutions, there are no particles of solid resin present. The material is a single phase mixture of copolymers, unreacted monomers and solvents. In this situation, the stripping operation is conducted in a continuous still system by a distillation mechanism which for VCM removal is much more rapid and complete than when a diffusion mechanism is controlling the separation rates, as described above.
As a result of this process characteristic, we are able to consistently remove the VCM to an average level of 10 ppm or less (dry resin, daily average basis). The sampling and analytical procedures and schedules prescribed by the regulation are far more frequent, extensive and costly than necessary to assure ourselves and the regulatory agencies that the 400 ppm limit is being met.
ucc
050933
Mr. Cecil Bradford Mr. Allyn Daws March 29, 1984 Page 3
DESCRIPTION OF STRIPPING OPERATION
The production unit has four separate polymerization and product recovery lines, each capable of accommodating the different molecular weight and compositional variations of the copolymers in our production inventory. Each train begins with several polymerization vessels which feed in parallel into a dilution tank for the solvent adjustment of the varnish prior to stripping to provide the optimum specific gravity for the stripping step. The properly diluted varnish then goes to the top of a stripping still column containing sixteen valve trays. All system components in contact with the varnish are of stainless steel construction. The columns vary in diameter from one line to another and have varying capacities as indicated:
Stripper No.
1
2
34
Column I.D., inches 48
42
42 36
Average Varnish Feed Rate, Lb/Hr
25,000
18,000
18,000
7,000
Control of the stripping operation^ to remove the maximum amount of VCM is achieved by the counter-current upward flow of solvent vapors from the base of the stripping column, thereby contacting the down-coming varnish across the valve trays and carrying out the more volatile VCM in the vapor stream from the head of the column
The schematic shown as Figure 1 illustrates a typical stripper configuration with the various streams involved. The description of the designated streams marked in Figure 1 are listed in Table I.
HISTORICAL DATA
As previously stated, this distillation mode of stripping is capable of consistently removing VCM to a much lower level of residual VCM in the resin stream than the 400 ppm weighted daily average required by the regulation. Because of this, we believe that the high frequency of sampling (every eight hours) and the subsequent analytical effort constitute an excessive amount of time, effort and funding for the purposes of the regulation.
3 The solvent boiling point is 56C, vinyl chloride monomer (VCM) boils
at -14.3C and the two materials are infinitely soluble in one
another.
UCC
050934
Mr. Cecil Bradford Mr. Allyn Daws March 29, 1984 Page 4
The Semiannual Report data for the past three years is summarized in Table II, which confirms the previous statements. In reviewing this information, several items should be pointed out. First, there has been only one daily result greater than the 400 ppm upper limit during this three year period. (At that time, there was some question about the validity of the samples which could not be resolved, so the test results were retained.) There is a definite improvement in the mean value for Ati for the six-month periods since September 1982 as well as a significant reduction in the number of days in each period having A^-i results of over 10 ppm.
In our Semiannual Report of October 21, 1981 for the March-August 1981 period, we mentioned that we were attempting to collect operating parameter data to correlate with the VCM analytical data for corresponding daily samples of stripped resin. Allowing for several extensive shutdowns for inventory control and availability of technical manpower during this time, we attempted to correlate the daily VCM results (Ati values) with the stripping system operating parameters.
The major controlling variable in the stripping operation is the ratio of the liquid varnish feed down the column trays to the solvent vapor flow up thru the trays (L/V ratio). As long as there is sufficient liquid varnish feed to cover the trays to the proper depth for correct tray valve operation, the solvent vapor passing upward provides the heat and contact time to almost completely remove the VCM from the varnish.
We normally could show very good stripping effectiveness if this L/V ratio stayed within certain limits. However, in the data we collected from the production operations, there was a small number of erratic VCM test results on individual varnish samples that were much higher than expected from the L/V ratio in effect at that time. We could not assign any definite causes for these infrequent excursions, other than the possibility that there were opportunities for nonequilibrium and nonuniform conditions to exist from time to time in the varnish feed from the autoclaves into the stripping column. We were dealing with a viscous polymer solution that may not have been uniformly mixed before sampling for VCM analysis.
PROCESS IMPROVEMENTS
A technical review was conducted by the production staff and several situations were disclosed which could have contributed to this problem. The following process modifications were incorporated into the systems over about two year's time, as manpower and funds became available, to reduce the VCM levels in the stripped varnish and improve the reproducibility and uniformity of the VCM content in the streams.
1) "Dynatrol" specific gravity measuring instruments were made fully operational in the first quarter of 1982. This change increased the reliability and accuracy of this process control which permits higher vinyl chloride conversion to polymer in the reaction step. This in
UCC 050935
Mr. Cecil Bradford Mr. Allyn Daws March 29, 1984 Page 5
up
turn reduced the amount of unreacted monomer in the varnish feed to the stripping stills. The "Dynatrols" have smoothed out autoclave polymerization operations so that more steady state operations can take place in the stripping step of the process.
2) In the first quarter of 1983, the operation of the gravitometers on the stripping stills was improved by changing from an intermittent to a continuous flow to the instruments, thereby smoothing out the feed to the stripping stills. This helped to improve steady state operation of the stripping stills. We know that it is very important to maintain steady state conditions in the base of the still if the VCM levels are to be consistently low and uniform.
3) Further improved control of the polymerization step of the process that has contributed to better stripping still operation involves an automatic on-stream analyzer coupled with a computer control. An AMSCOR MS IV analyzer has been installed to accurately monitor the quality of the feed streams and other components used to make up the feed streams. This analyzer has been matched with a MOD COMP computer that provides valuable historical data and makes the necessary calculations required to maintain a more uniform autoclave feed consistent with specified product properties desired. This addition was made in the third quarter of 1983.
4) At present, we have just completed a change in autoclave operating procedure that allows for the continuous purging of inerts from the vapor phase in the autoclaves. This improves heat transfer from this exothermic reaction and causes a more reliable temperature control of the polymerization. This improved temperature control in turn permits operating with a greater degree of confidence in the polymerization step, leading to higher conversions of monomer to polymer and thus, less VCM to strip from the varnish to the recovery system.
These changes have effectively improved the stripping operation as shown in Table II with lower daily maximums and a significantly
reduced mean value (from around 6 ppm to less than 4 ppm VCM) for the different six-month periods.
STRIPPING CALIBRATION TESTS
In order to show conclusively that the VCM content of the stripped resin could be properly controlled by maintaining the proper L/V ratio on the strippers, we conducted four separate full-scale production tests to d termine a quantitative relationship that could be used to achieve the required control for compliance with the regulation.
Three separate tests were run on the largest stripper (No. 1 - 48" diam. column) during the production of VYHH resin, our highest volume product, at high, medium and low varnish rates. VYHH resin is a high
UCC 050936
Mr. Cecil Bradford Mr. Allyn Daws March 29, 1984 Page 6
molecular weight, high PVC content copolymer which produces a relatively high viscosity varnish that would be the most difficult to strip of all residual VCM.
The basic controlling factor, as stated previously, is the ratio of stripping still varnish feed rates at the top of the column to solvent vapor feed rates into the base of the stripping column. Accordingly, with steady varnish feed rates at each of the prescribed flows, the vapor feed rates were reduced stepwise (thus increasing the L/V ratio) until the VCM content of the varnish began to increase.
A fourth test was run at low varnish feed rates on VMCC resin (a low molecular weight, low PVC copolymer providing much lower varnish viscosities) in No. 3 stripper (42" diam). This test was selected to see if a VCM breakthrough would occur because of rapid rundown of varnish through the trays without sufficient contact with the solvent vapors.
We would expect in a stripping operation involving equilibrium conditions between a viscous polymer solution and compatible solvent vapors that the higher PVC content, higher molecular weight copolymer varnishes would be more difficult to strip because of the higher varnish viscosity and that the less viscous varnishes would be the easiest. This was clearly demonstrated by the test runs that we made (see Figure 2), although the practical differences were not significant insofar as me ting the NESHAPS requirement for a 400 ppm top limit on VCM content.
The test data for these calibration tests is shown in Table III and the graphs are plotted on Figure 2. It appears quite obvious that as long as the L/V ratio is maintained in the range below 2.5 that the VCM content would be expected to fall below 10 ppm. There are several other variables in this stripping process, but they do not vary appreciably and have far less effect on the VCM remaining in the varnish. The range of operating conditions possible in these stripping stills is shown in Table IV with the corresponding L/V ratios encountered.
UCC 050937
________________P/fy?6Sf>
a*/>
_ ^___________________ftA/TM/ftfC/S y?fcA//Stf X77?//>/*///St Ca#7&0t /foeWreFT/e
MOV/mwa.
I r-
m\
&yUtyyafa Itrtfa 7fa
fa cfafafa /^tP suc<n</ fa& G0\*4ks /sycusucf ^
et4&U*/ 40/fafa> yCW pfaffUrupfa #ufa _
fat /uyufaSSy faSnfafa /?/P^u-u-fa^ fa&ts art &ffafa
/^faSA^fa *^wyfyrtS wfa jfaj? fatfat/\
_.jpAfU/J Ufa* ? afafa yrty /) /K/y /*yfa~ a~// yfaSuA faufay fa fat
____ fa/yrtny cyrtrtsLsyrt,
. <S/t. autoo arfart cW^fafattfaA*faa>7 /tuu/TP
fa______ ycr^n fa ccfaaZn oyrttfafajrt fa ^****(. yA/prtn z^rtfa/ fa______
___CavS^fafay -fafay -^/rtAufaSy trt su<yfa/
fayyfa-y
...
. faSjfayrtfaaia fanya
fa/ <^2efafaty fay fa- fa Joa/ fat
.__ .__
____tymtfaj *M AMT*A(_ /
ytl/yteofa fa fa &rtfa /fa y/rtrt&*.
_______________________ fakcxfafay/ ^ fa fait fafaufac#?^ a stypsuafa Ay faefa
____ fa) fai fafa/ui rfrturt&j C/pl^a/ jzwi&O fat /fartf**^
?r\ 4
A*fa*:. _.
j)./**### Pee# #*-&, A?fa/fa^
_-(/)
Jl) SotefAST MASK fffP
Mfafafa
OWirfad//itcaiMo ,.~. fa/).-
-fa) __ fay A/far jh*r> /) Ars( /)
far
________________ fa afarxyo yfafart Jp. S'___________
_--------------.fafac/t
------------
Jyfafan fa*^ fa/} ff*t/>i efartacfaui-fai
UCC 050g38
A
<7^jfek/
dukfef ^y TL
I4y/
deAopj <Y Tfc AyTfep .
/$JSfyafarns rft**
T? tpZ&tfefeO HfTOoi) TO yPAAA-r^xfei sfepotw a**/ A_***pA
. jTfWl fe\ 7*^6-U/l fe yu^fe-C/ jfe dUM/s/
Tj
A^OcTt'&KjytA
A CC^fXTp<z^yt t_S JtrTO) 70s z77?sT7
CuAsirtJ &kw?\ fei /Zc^usU ,
s^^Acfe-A At? fe
typ&feb &// TO
feO~ TfeitOy fefeO A&uTfe*
tviZh TO
A/dcr Ayfe~*Ap. sfe0 Tab*) J?,6~.
----- .---------- /T> /fey Ahitzfe^ ^un aTfe cPufea<^^T^ ht<00/
filhti'' sfeis A^4sfeu7?Wyrife ASA tOriyo &7 sfe/T -~fes>i/i
_______tfeZcil-Tlfe J/\ JO ^sUAA>A&u; Tufet/ aferi
J.&cJi pAf*Ulfefefe /few
4 _ tfe*
/$aO
.TO 6rud // # c7 thy / w~
-ti-C/^PP/tf /SSjZ-Z>
y)fetfe fe\ Osh/ /pWUtfej ffelppAlA C/7i/y /a ftn/cttjOtA&f
---- (Iru/
A*} jfrfece 0j/ 70 /fe^- /TA-fes ^4rttfltdty
AA^?/vhi{jh) -aT
T# fey^y a? /h(p 'tfA-feza
- t~y /fe
/fe*0 j$fe-> -?
TO PPTA7 t/nTZpr y''
.JA yuAn A A/ ,/n-?yrS/ TauuW ZiA/A trAS /-7<^
Jb
//*?* ?nds?s&*?vUMv jpzt c^fejf Py TO /Cfy^Ttfe^.
.
... ^fTTusi/Oy^ Tilt &&[ *MAj
fMyMwfewyTOf
j/ hfe yAp/ntsi/ T# acctfi&TT'^ At? Tfefe TO TfeTfe*>^/7?
_ JpWiriTj tyCfcwjrtid AtA^OnT~ feCZP A tOtfe c's>?C*-feO& , Jtrfeccfe &tr> y&t?-fwO T~H'thy Af^tyew y/ a///t&lfeu+T
___y?/itA??Afeij^ a,*u7 &h cfeOO/ aw fe /tTyT ***' a* c7
$(rUT Th jytnS '
iCr&i/ys
/f^cTuA jfe oaL/
____'00 fei& jO/) yw^tnfey p*iym4<?
wTkO&df
CtTWytToCf^tf<
TZr
ucc
050939
TABLE I DESCRIPTION OF PROCESS STREAMS IN
VARNISH STRIPPING OPERATION (REFER TO FIGURE 1)
A Autoclave varnish to dilution tank.
B Fresh acetone to dilution tank.
C Fresh acetone to vaporizer to stripping still (also designated vapor feed = "V").
D Overhead vapor from dilution tank to vent condenser.
E Diluted varnish feed to stripping still (also designated liquid feed = "L").
F Stripping still overhead vapor to vent condenser.
G VCM and solvent vapor to monomer/solvent recovery system.
H Reflux solvent to stripping still.
J Stripped varnish to resin recovery system.
MATERIAL BALANCE - TYPICAL FOR NO. 2 or NO. 3 STRIPPING STILLS
E+C + D=
G
+
J
16,855
+ 10,655 + 1575 - 11,675
+ 17,410 = 29,085
LA RATIO - E / C = 1.58
ucc
050940
Period Sept. 83 - Feb 84 March 83 - Aug 83 Sept 82 - Feb 83 Mar 82 - Aug 82 Sept 81 - Feb 82 Mar 81 - Aug 81
TABLE II
SEMIANNUAL REPORT DATA SUMMARY - MARCH 1981 THRU FEBRUARY 1984
No.of Operating Days 117 172 111 111 122 180
Mean A^i PPM VCM
3.8 3.6 4.4 6.4 17.0 5.9
Highest An for Period
87 104 217
82 795*
62
Comments 9 days over 10 ppm 11 days over 10 ppm 7 days over 10 ppm 19 days over 10 ppm 34 days over 10 ppm 25 days over 10 ppm
*Only day over 400 ppm, next highest day was 215, all other values for this six-month period were less than 90 ppm.
oC ! O
O
STRIPPING STILL No. 1 48" Diam. Date: 11-21-83
Dat : 11-16-83
Date: 11-8-83 No. 3 (42" Diam) Date: 11-8-83
TABLE III VARNISH STRIPPING CALIBRATION TESTS
TYPE RESIN
VARNISH FEED RATE, L
#/HR
VAPOR FEED RATE, V
#/HR
LA RATIO
VYHH
HIGH RATE -
Time
7:50 am 9:55 am 10:20 am
27,000 27,000 27,000
15,500 10,800
7,700
1.7 2.5 3.5
AVERAGE RATE -
11:55 am 12:35 pm
1:10 pm 1:50 pm 2:30 pm 3:10 pm
22,000 21,700 21,700 21,700 22,100 21,000
17,000 14,500 12,000
8,700 7,200 6,000
1.3 1.5 1.8 2.5 3.0 3.5
LOW RATE - X
11:25 am 12:10 pm 12:40 pm
1:30 pm
15,000 14,500 14,500 14,500
10,000 8,000 6,000 5,000
1.5 1.8 2.4 2.9
VMCC
LOW RATE
8:20 am 12:00 n 12:35 pm
1:25 pm 2:15 pm
10,500 10,500 10,500 10,500 10,500
7,500 6,500 5,500 4,500 3,500
1.4 1.6 1.9 2.3 3.0
STRIPPED VARNISH VCM CONC. (1) PPM
0.28 nil 30.5
0.48 0.52 0.55 0.79 9.00 112.00
nil 0.11 4.12
93.40
0.27 0.28 0.20 0.25 0.66
ucc
050942
(1) Dry resin basisr same as used to calculate A^i daily weighted average.
ucc
050943
V
TABLE IV
SOLUTION VINYL RESINS PROCESS
TYPICAL OPERATING PARAMETER VALUES
Stripper No.
Stripper Column Diameter, Inches
I. Feed Rates
STRIPPING STILLS
12
3
4
48 42
42
36
II.
Ill IV
A. Varnish Liquid * E
Lb/Hr
Max
Avg
Min
B. Solvent Vapor - C
Lb/Hr
Max
Avg
Min
32,000 25,000
8,000
21,000 18,000
8,000
21,000 18,000
8,000
14,000 12,000
6,000
19,000 18,000
8,000
14,000 13* 000
6,000
'
C. Ratio L/V = E / C Most likely operating ranges.
Max/Max Max/Avg Avg/Max Avg/Avg Avg/Min Min/Min
1.52 1.39 1.00 1.78 0.44 1.19
1.50 1.50 1.33 1.75 0.67 1.28
1.36 1.38 1.33 1.46 0.62 1.28
Still Columns, average base temperature: 63C, All Columns, + 3C, Solvent boils at 56C at 1 ATM.
Still Columns, average base pressure: 2 psig. All Columns.
Column differential pressures, base to head, inches of H2O.
10,000 7,000 5,000
8,000 ' 7,000
6,000
1.25 1.00 0.83 1.43 0.71 0.88
Stripper
1 2 3
Diff. Press, Inches
30
70
70
4 40
---... iU%ifc
"-tFtI
SOLUTION VINYL RESINS PROCESS VARNISH STRIPPING STEP TO REMOVE UNREACTED VINYL CHLORIDE MONOMER CVCM)
XRR374
woso
oon