Document p22b8a0Jme3ap5R4VEMMr9zL6

Tentative Bulletin Iuz. i Al ms 1289 A Heat Transfer Fluid Candidate for Replacement of Therminol FR Lo-Temp for the Trans Alaskan Pipeline - Use Range of -20 to 400F. "Nothlnf contained hewn is to be constrood n recommendation to Mt any product in conflict with iny pttent. MONSANTO MAKES NO WARRANTIES AS TO THE FITNESS OR MERCHANTABILITY OF ANY PRODUCT REFERRED TO. no luirintto ol sotisfutory nulls from rtlitnco upon contained infoimstion of recommendetione, ond disclaims ill liability lot any rosoltini loss or Monsanto Industrial Chemical Co. Specialty Products 0100559 TOWOLDMONOQ22149 c Typical Properties of MCS 1289 Composition Appearance Odor Pour Point Plash Point PIre Point Autoignition Temperature (AIT) Specific Gravity at 75F Density, lbs/gal. at 75p , Viscosity, os -65P 0*P 100P 200P 300#p 400P Vapor Pressure 420"P 572P 6l0P Specific Gravity -60" P -20#P 75P 200 P 300 P 400#P Specific Heat 212P Modified Ester Base Clear Yellow Liquid Paint -65F 405 P 438P 705P .919 7.63 6490 125 8.85 2.70 1.30 .85 10 mm Hg 180 mm Hg 590 mm Hg 976 958 MS 825 785 approx. .56 BTU/#F 0100560 TOWOLDMONOQ22150 MCS 1289 is intended for use as a heat transfer fluid where low ambient temperatures cause pumping problems with exist- . ing heat transfer fluids. The normal use range for MCS 1289 will be -25P to 400F bulk temperature maximum with an upper limit on film temperature of 450F. For long term use we suggest a maximum bulk temperature of 375P in a non-pressurized system; however, we do suggest a light inert gas blanket or cold seal for the expansion tank vent to preclude air contact at temperatures over 150F. MCS 1289 is not a fire resistant fluid. Although normal use temperature is below its flash and fire point we suggest that suitable precautions be taken to minimize the risk of fire. Preliminary toxicity studies indicate that MCS 1289 should re quire no special handling precautions nor should it present an environmental hazard. Continuing studies are'under way to pre pare more complete toxicity data. MCS 1289 has been tested in an N & C (nltrogen'and corrosion) test for 168 hours at 450P with metal coupons to check metal compatibility. The tests indicate no abnormal metal attack, carbon formation or fluid property change. Heat transfer fluids are intended for indirect heating purposes only. Under no circumstances should heat transfer fluids con tact or in any way contaminate food, animal feed, food products, food packaging materials, pharmaceuticals or any food related items. Any contact may contaminate these items to the extent their destruction may be required. 0100561 TOWOLDMONOQ22151