Document ozOLakzgOoDDx3noo4mX8MQo

FILE NAME: Flooring (FLR) DATE: 1989 May 30 DOC#: FLR025 DOCUMENT DESCRIPTION: Unpublished Report by Atlantic Environmental - Monitoring of Airborne Asbestos Fiber Release - Sent to Randolph Board of Education, NJ - with Several Letters and Memos Attached F la w F t RANDOLPH TOWNSHIP SCHOOLS ID H A ID H MZEZOVSKI, M. 0157*10 f S C lM f * usjncss orna SCHOOIHOUSE ROAD, AASDOlPH. N J 0786 (201) 328-278* NJDOH Asbesto CN 360 Trenton, Control Service NJ 08625 June 14, 1989 Att; Mr. Michael Lakat Special Assistant to the Director Ref: Vinyl Asbestos Tile* - Air Monitoring Report Dear Mr. Lakat: As per our telephone conversation earlier today, Wednesday, June 14, 1989 attached please find a copy of the report prepared by Atlantic Environmental Inc. (AE1) and our original scope of work. Based on your recommendation 1 have requested AEI to rerun the four TEM samples using another lab. We should have these new results vithin one week. I will call you with these findings as soon as they are available. The results of these preliminary tests may effect educational and public facilities across the State. We therefore are formally requesting the combined assistance and technical expertise of NJDOH Asbestos Control Service and NJ PEOSHA to deal with this potential State wide problem. Since "time is of the essence" with the summer cleaning period rapidly approaching and our intent to provide a safe, clean, and healthy working environment for our staff and students your guidance will be needed within the next two weeks. We will provide any assistance that may be required to complete these tasks. Should your require any additional information please do not hesitate to call. We look forward to your response. District Engineer E n clo su re CC: Mr. Robert Gordon, Superintendent Mr. Frank. Pepe, Assistant Superintendent for Business Rrenton, Program Specialist II, NJ PEOSHA QMvnJtfi 'Of<&40 TO: FROM: RE: DATE: Principals, 1-8 Robert Gordon, Superintendent $ ? Asbestos Abatement June 27, 1989 This memorandum is a follow-up to the meeting held yesterday regarding the cleaning of tile floors. Until further notice, no power equipment of any kind is to be used on tile floors. Custodians may continue to use normal cleaning and care procedures on terrazzo and wooden floors. This directive is designed to ensure against possible high levels of airborne asbestos fibers caused by abrasive treatments of these floors. There is to be absolutely jjo deviation from the terms of this directive. R G :dec Copy : Frank Pepe Edward Brzezowski fOW AIO H. crEZO V SKt. tX. oisTticr fivciNfru 4 11 i v ^ v v i N a m K S C H O O L S usiniss otnci SCHOOt MOUSE *OAO. KAN O O lfH . N J. 0?S*9 771ft June 29, 1989 NJDOH Asbestos CU 360 Trenton, Control Service NJ 08625 Attn: Mr. Michael Lakat Special Assistant to the Director Ref: Vinyl Asbestos Tiles - Air Monitoring Report Dear Mr. Lakat: Pursuant to our telephone conversation, Monday, June 26, 1989 in reference to the above: 1. The second lab TEM tests by EMSC confirm the original tests by AMA. 2. Based on these results, the normal process of stripping and waxing VAT appears to be above the PEOSHA action level of 0.05 F/CC. 3. NJDOH and NJ PEOSHA are reviewinq the methodology and report prepared by Atlantic Environmental Inc. 4 . Formal recommendations and guidance will be provided by NJDOH/NJ PEOSHA by the end of July 1989 or sooner. During this refrain from tiles.I review process, Randolph Township Schools will all stripping and waxinq of vinyl asbestos floor I thank you in advance for your prompt and serious attention to these matters. Edward H. BrZez o w s k i , P.E. District Engineer EHBrgb cc: lir. Robert Gordon, Superintendent of Schools fir-. Frank Pepe, Assistant Superintendent for M- r n .. I ---------------------- Business MOLLY JOEL COVE. ^ 0 M P M COMMISSIONER i - r - r 1234- C/tT <itj> tilatt of fteuj Jcrseu DEPARTMENT OF HEALTH CN 360. TRENTON. N.J 08625-0360 July 28, 1989 IC.,J BCARl JrrlC c ) J i Frank M . Makein, Supervisor Health and Safety Cooperative Faquamock Township Board of Education Oak Avenue and Lincoln Park Road Faquarmock, NJ 07440 Dear Mr. Makeln: The Asbestos Control Service (ACS) has reviewed the environmental survey comparing three methods of stripping and waxing vinyl asbestos floor tile (VAT). Major problem areas regarding the basic study design, execution, and conclusions were noted. These problems have caused the results and any subsequent interpretation to be called into question. At best, any inferences which can be drawn are of very limited value. Although no compelling evidence was presented which would warrant any regulatory action, the Service finds it necessary to issue an interim advisory for the maintenance of vinyl asbestos floor tiles. This action was predicated by the concerns raised primarily by members of the Health and Safety Cooperative for employee and occupant safety. 1. Pursuant to 40 C.F.R, 763.91(a), "[airy material identified as ixifliable AQEM or ncrLcriabxe assumed ACB4 must be treated as friable ACB*! for jxirposes of this section when the material is about to become friable as a result of activities performed in the school building." Since VAT falls within the purview of the above-referenced section, general guidelines found in the non- *" mandatory Appendix B to Subpart E-- Mark Practices and Engineering Controls for Snail-Scale, Short Duration Operations, Maintenance and Repair (06M) Activities Involving ACM are instructive; 2. Any operations and maintenance activity which has the potential to release fibers from vinyl asbestos floor tiles should be avoided; 3. If these activities must be performed, they shall be conducted only when the building is unoccupied; 4. A H operations and maintenance activities 1 waiving VAT shall be performed by individuals who have received he two-day 0 6 M training; 5. Dry stripping shall not be performed: 6. Non-abrasive means of stripping and buffing shall be erployed; 7. IXje to the potential for direct expo-ire to the individuals performing these activities, adherence to the provisions of the Safety and Health Standards for Public Drployees (N.J.A.C. 12:100 et 9eq.) shall be required. Specific references Inrdiidp/ but are not limited to: a. engineering controls (N.J.A.C. 12:100-12.4), b. general work practices (N.J.A.C. 12:100-12.5), c. respiratory protection (N.J.A.C. 12:100-12.8), ard d. personal protective clothing (N.J.A.C. 12:100-12.9); and 8. Pursuant to 40 C.F.R, 763.94(f), records regarding this activity shall be maintained as part of the school's asbestos management plan. As stated above, these recrituudations are predicated cn the results of a flawed study. Hcwever, the ACS has entered into preliminary discussions with several outside consultants as a prelude to fully addressirg this issue during the early part of 1990. If I can be of further assistance in this matter, do not hesitate to ccntact me at 1-609-984-2193. 'jVery truly yours. c: Virginia Brenton Edward H. Brretowski Michael F. Lakat Special Assistant to the Director Asbestos Centro! Service ?IHTL A S K S T O S FLOOR T I U Oprations and Maintenance Field Tetting COAL: To teat for the releaae of asbestos fibers during the normal tripping and waxing vinyl asbestos floor tiles. These tests docuaented results for both proper "vet" stripping and worst stripping and waxing. process of would provide case "dry" TEAM: The teaa would be coaprlsed of an NJDCA approved Asbestos Safety Monitoring (ASCM) firs and a NJDOL licensed asbestos contractor. school will provide the work, site and associated floor stripping equipment and saterials. Control A host and waxing SEQUENCE: An Isolated area of a school will be used as the test site on a day that school is not in session. Prior to running the tests the ASCM will take samples of the floor tiles to confirm the presence of asbestos fibers. The contractor will Isolate three separate work areas and Install "critical barriers'1 in order to prevent any possible contamination during the test. The asbestos contrsctor will also operate the stripping and waxing equipment during the test. The wo: alte shall be returned to original conditions and all debrl shall be disposed of by the asbestos contractor. METHOD#1 (SEMI-DRY STRIPPING) METHODS (VET STRIPPING) Strip dry/damp floor w/coarse pad using wacer/soap/scripper mix. Strip vet floor w/coarse pad using vater/soap/strlpper mix. Rinse w/clear water & vac. (Repeat 2 -3 tiaes) Rinse v/clear water A vac. (Repeat 2 -3 tiaes) Wax v/no-buff floor wax. (Repeat 2 tiaes) Wax w/no-buff floor wax. (Repeat 2 tiaes) METHOD#3 Same as Method?2 except a nonscrubbable stripper will be used. RESULTS: Multiple air sampling results will be analyzed using TEM to confirm the presence of asbestos fibers and their concentration levels during all test methods. A background test prior to starting this work shall also be made. RECOMMENDATIONS: After the results are analyzed, if asbestos fibers are released the ASCM will provide a 1 day "in-service" to review the proper methods of stripping and waxing VAT without releasing asbestos fibers. A written guidance document will also be prepared by the ASCM firm. RANDOLPH TOWNSHIP SCHOOLS OFFICE OF DISTRICT ENGINEER SCHOOLHOUSE ROAD RANDOLPH, N.J.07869 (201)328-2786 EDWARD H. BRZEZOW SKI, P.E. DISTRICT ENGINEER December 5, 1989 M r . Tom Leary c/o Annerardale County Public 9034 Fort Smallwood Road Pasadena, Maryland 21122 Schools Dear Mr. Leary: In response to your recent request, I am forwarding a copy of the air monitoring report for tests conducted on vinyl asbestos tiles in the Randolph Schools. I hope you find it to be useful. Sincerely EHB:gb Enclosure Edward H. Brzezowski District Engineer ATLANTIC ^ ENVIRONMENTAL INCORPORATED 2 E BLACKWELL STREET. DOVER. NJ 07001 (201) 366-4660 FAX (201).366-3116 June 14, Mr. Ed Brzezowski Randolph Board of Education Office of the Superintendent Schoolhouse Road Randolph, NJ 07B69 Dear Mr. Brzezowski: Enclosed is the report for the air monitoring performed at Ironia School on May 30, 1989. I am forwarding a copy of the report to the New Jersey Department of Health as per your request. Thank you for allowing us to be involved in your project. Should you have any questions regarding this report, or if we may be of further service, please feel to call. free Sincerely, / <U.-/ Melissa Bowles enc. cc: NJ DOH ATLANTIC 1 ENVIRONMENTAL Randolph Board of Education Ironia School, Ironla, NJ May 30,1989 Air Monitoring 1.0 INTRODUCTION Atlantic Environmental Inc. was retained by the Randolph Board of Education to perform monitoring of airborne asbestos fiber release during a comparative study of three methods of stripping and waxing vinyl asbestos floor tiles. The test was performed at Ircnia School, Ironia, New Jersey. All three methods of stripping and waxing were performed under full containment by Bergen Tech, a licensed asbestos removal contractor, New Jersey license #00125. Monitoring was performed at the request of Ed Brzezowski of Randolph Board of Education by Melissa Bowles of Atlantic Environmental. 2.0 P R O C E D U R E S The tests were performed on asbestos containing floor tiles located in the cafeteria/auditorium of Ironia School. (Please see Appendix A for tulk sample results.) Three portable 4'X 4'X 7* #4400 ,,Dispos-A-C.*Jn', containments, made of 2 layers of 6 mil plastic supported by pvc tubes, were erected in the center of the room. The containments were placed approximately four feet apart and were connected plasticized chambers constructed by the contractor. The wo;cers stood in these chambers while performing the stripping and w w i n g processes inside the containments. The three different stripping/waxing processes are described as follows: Page 1 ATLANTIC __ ` ENVIRONMENTAL Fanbolph Board of Educatici Ironia School, Ironia, NJ M ay 30,1989 Air Monitoring Me the 1 #1 (Semi-Drv Stripping) Strip dry/damp floor with course pad using water, soap and stripper mix Rinse with clear watar and vacuum (repeat 2-3 times) Wax with no-bi'ff floor wax (repeat 2 times) M ethci 47 - fWet Strippingx. Strip wet floor with coarse pad using water, soap and stripper mix. Rinse with clear water and vacuum (repeat 2-3 times) Wax with no-buff floor wax (repeat 2 times) Methci #3 - (Non-Scrubbable Stripper) Strip wet floor with non-scrubbable stripper mixture. Rinse with clear water and vacuum (repeat 2-3 times) Each of the abcve methods was used in a separate containment. The ccntractor was briefed on the proper procedures for these methods by the head custodian of Ironia School. Each method took less than fifteen minutes to complete. Two samplers were set up inside each containment. Samples to be analyzed by Transmission Electron Microscopy (TEM) were set at five feet above the floor and samples to be analyzed by Atlantic Environmental using Phase Contrast Microscopy were placed two feet above the floor. One TEM background sample was taken before Page 2 ATLANTIC k ENVIRONMENTAL Eandolph Board of Education Ironia School, Ironia, NJ M ay 30,1989 Air Monitoring stripping procedure; commenced. Other samplers were turned on at the beginning of ea,h procedure and were turned off approximately two and a half hours later (the time required to collect a sufficient volume of air to perform analysis.) After sampling was completed, the contractors collapsed the portable chambers and double bagged all other materials. All materials were to be disposed of by the contractor as hazardous waste. (See Appendix A for air sample results and Appendix B for a diagram of sample locations.) 3.0 SAM PLING M ETH O DS AND ANALYSIS Electric pumps /ere used to monitor the fiber concentration in the air during t'.a stripping procedures. Air was pulled by the pumps through 0.3 micron mixed cellulose ester filters mounted in electrically conductive 25 mm plastic cassettes attached to the pumps using plastic tubing. All pumps were calibrated before us a for a flow rate of 15 liters per minute, and checked immediately afterward for accuracy. Air samples we;s obtained using open faced methods required by the National Institute of Occupational Safety and Health (NIOSH). Transmission Electro i Microscopy (TEM) was used to analyze the background sample ai.i for cassettes placed in the breathing zone of each containment. This method is in accordance with AHERA level II method for airborne asbestos fibers. Phase Contrast Paae 3 -- ATLANTIC " ENVIRONMENTAL Randolph Board of Educatior Ironia School, Ironia, NJ M ay 30,1989 Air Monitoring Microscopy was used to analyze cassette filters placed two feet above the floor and for the clearance sample. This method is in accordance with NIOSH specifications #7400 Method for airborne asbestos fibers. 4.0 RESULTS All TEM air sanoles taken (except for the background sample) were found to contain between 0.0199 and 0.0822 fibers per cubic centimeter of air (f/cc). These results are within the Occupational Safety and Health Administration (OSHA) permissible exposure of 0.2 f/cc for an eight hour time weighted average;and are within the OSHA and the Asbestos Hazard Emergency Response Act (AHERA) "action level" of 0.1 f/cc at which employers must initiate compliance activities such as worker training and medical surveillance. Results associated with scrubbable strippers (methods # L and #2) are above the action level of 0.05 f/cc set by the New Jersey Public Employees Occupational Safety and Health Act. All sample results are above the Environmental Protection Agency (EPA) recommended level of 0.01 f/cc for air quality outside of a containment during abatement operations and also above the acceptable criteria for the re-occupation of an area after abatement (also 0.01 f/cc). All samples aralyzea by PCM method resulted in levels of less than 0.002 f/cc except for the sample associated with Method #1, the semi-dry stripping method, which resulted in a level of Page 4 i , J H -- _ ATLANTIC M tk " ENVIRONMENTAL Randolph Board of Education ironla School, Ironla, NJ May 30,1989 Air Monitoring 0.007 f/cc. According to AMA Analytical Services of NY/NJ, Inc., the majority of fibers in the samples analyzed by their laboratory using TEM were of less than .25 microns in diameter. Fibers this small axe not easily detectable using PCM method. CONCLUSIONS AND RECOMMENDATIONS While actual sa rple results cannot be compared to permissible exposure limits based on eight hour time weighted averages, the data suggests that a significant number of airborne fibers were releasee in the scrubbable stripper methods (Method #1 and #2). If similar levels resulted during the stripping and waxing of a normal sized area using normal custodial procedures, and if no containment were erected, then these levels would exceed the EPA and AHERA recommended level of 0.01 f/cc for areas outside a containment and for re-occupancy of an area after abatement. In fact, sample results would indicate that even Method #3, the non-scrubbable method, resulted in unacceptable levels of airborne usbestos fibers. It seems possible, however, based on o b s e r v a t i o n of the containment construction, that cross contamination betweui the containments occurred. In summary, additional data, including personal exposure data, would be needed to draw any definite conclusions. We strongly recommend, however, that in accordance with 40 CFR Part 763 Asbestos-Containing Materials in Schools? Final Rule and Notice, under Apoendix B to subpart E "Prohibited activities" Page 5 ATLANTIC __ " ENVIRONMENTAL andolph Board of Educatlor Ironla School, tronia, NJ M ay 30,1989 Air Monitoring that the floor tiler containing asbestos not be sanded or abraded unless proper contai unents, respiratory and air sampling methods are employed. Report written by: Report Reviewed by: v;, /. / Melissa Bowles '/ / C ^ /' < /(-* r ------- Michael Donovan, Manager, Field Operations File\arpl\RBED0530 Page 6 ATLANTIC ENVIRONMENTAL APPENDIX A RESULTS Page 7 ATLANTIC ENVIRONMENTAL SAMPL. ANALYSIS FOR BULK ASBESTOS Material Sampled: Vinyl Asbestos Floor Tiles Client: Randolph Board of Education Location: Ironia School Ironia, New Jersey SURVEY DATE: May 22, 1989 SAMPLING METHOD: Bulk Asbestos sampling ANALYTICAL METHOD: Polarized Light Microscopy in accordance with EPA recommended methods. SAMPLING PERFORMED BY: Kevin Collins ANALYSIS PERFORMED BY: Paul Valvo Sample Number Description IEM0522A Cafeteria, Brown floo tile IEM0522B Cafeteria, Red floor tile IEM0522C \ Cafeteria, Grey floor tile Results Chrysotile: 5% Non-fibrous minerals, binders Chrysotile: 4% Non-fibrous minerals binders Chrysotile: 5% Non-fibrous minerals binders Page B ATLANTIC ENVIRONMENTAL SAMPLE ANALYSIS FOR AIRBORNE ASBESTOS Material Sampled: Airborne Asbestos Client: Randolph Board of Education Location: Ironia School Ironia, New Jersey SURVEY DATE: May 30, 1989 SAMPLING METHOD: Electric air samplers calibrated before use and checked after use SAMPLING MEDIA: 25 mm cassette with 0.8 micron nixed ester filters Samples obtained using open faced method required by OSHA & NIOSH methods. ANALYTICAL METHOD: required Transmission Electron Microscopy according to AHERA level II method and Phase Contrast Microscopy in accordance with OSHA & NIOSH methods. SAMPLING PERFORMED Eif: Melissa Bowles PCM ANALYSIS PERFORMED BY: TEM ANALYSIS PERFORMED BY: Melissa Bowles AMA Analytical Services of NY/NJ Sample Number RBB053CA RBB0530B Location Outsid: containment, in cent *r of cafeteria (backgt 5und) Inside containment #1 5 feet from floor Method *1 Results fibers/cc TEM <0.0038 TEM 0.0822 ATLANTIC ENVIRONMENTAL RBB0530E RBB0530C RBB0530F RBB0530D RBB0530G RBB0530H Inside containment #1 2 feet from floor Method U Inside containment #2 5 feet from floor Method #2 Inside containment $2 2 feet from floor Method If2 Inside containment #3 5 feet from floor Method 13 Inside containment |3 2 feet from floor Method #3 Outside containments center of cafeteria adjacert to contain 41 (clearance) PCM 0.007 TEM 0.0552 PCM <0.002 TEM 0.0199 PCM <0.002 PCM <0.002 AMA AnolytlcoJ Services of NV/NJ, Inc. Environmentol Consultants CERTIFICATE OF AN ALYSIS Atlantic Envirwintnlal 7 Eatt laikofll Streat, Suite 74 Durer, RJ 07801 JOB SITEt JOB RUNIERt SUBNIHEO IVi Randolph Board Ol Ed 08C4-083? Atlantic Envirmweutal A1TN: Heliasa Boult ElllER IKIIAt HCE 73ue Riaeeter BRIE AMUTICBi CHAIN OE CtlSTOOT I PERSON S t M l I I I K i 0.1 Nitron Pormi tf DATE SANPIED 5/30/89 5/30/89 3/30/09 3/30/89 SUMMARY OF TRANSMISSION ELECTRON MICROSO ANA LAB IMIBER Cl IERI HUNIER VOIUNE SAItPLEP (LITERS) N9Q6010) RBI0530A 7100 N90MO2 R8I0530I 2143 N9060103 RII0330C 7100 H9040104 RIN330B 2100 FILTER RHEA ANALYZED UNI) .08)0 .0830 .0830 .0830 ANALYTICAL SENSITIVITY s/iw s/cc 1 13 0.007? 13 0.002? 13 0.0027 13 0.0072 RO. DT AS8E90S STRUCTURES CNRT. RNPN. 1 0 38 0 73 0 9 0 NO. OF RON-ASBESTOS STRUCTURES 0 30 9 0 ASI C0NCEI S/HN* 13 438 30? 109 Analytical procedure* a*fd o n t or exceed th* AHERA Materia Ir ansaisIon Electron Nicroscopp Analytical Hethod*' protocol dtK rlltd io Appendix A to Subpart ( ol 40 CFR Part 765. WHATSTi Robort R. f H.I'. pr|xDi j p p iin only tu i l * w m p li. or taniylet. Ir iv m iija ) am i li n oi i m i . * i l y HlN.Nivr u l Vw quality or condmon o l ap n an tH ly drill al O f vmtlj* (Kndm M Ac n I Hirer la b O tiim 'v . ihit >rporl it uilm uU fd and acCfptrd fot the fa rlu tiv f i w ol ilw i Im v h io w ho m * a d d iru rtf and t o o n H r (ondrtion i l i * rt ntn io br utut. w h o Ii.u if' wHioiil w iilirn iiUiotuaticHi lom ul Vju>|Hr lyprt, lorationt .imi i oltre Hun |Moiuiolt a ir b h r d upon the (rVormawm piovtdrtf by th* p ricon t k iln clava iiirin I atxMMOnet r r ip ifttly diulam * any k n o n M y r and lla U K y lot thr acculai y and lo n y ilrlrn rtt ol rhn tnlomMton A t rlgtci trcnvrd AMA Ana 1090 K in g G eo rges Post Road Suite 30/ ! dison , N J 00837 (901) 41/0 6 6 0 FA X: (901) 417-0664 To free 1(800)> AMA Analytical Services of NV/NJ, Inc. 6nvironmentol Consultants CERTIFICATE OF AN ALYSIS Allantic Environmental JOB SITE: Randolph Board of Ed 7 East Black*)I Street, Suite 7 JOB NUMBER: 0004-0837 Dover, NJ 07801 SUBMITTED BY: Atlantic Environaental ATTN: Melissa Soviet FILTER MEDIA: MCE 23mm Diaoeter DATE AHALY7ED: CHAIN OF CUSTODY I PERSON SUBMITTING: 0.B Micron Porosity DATE SAMPLED SUMMARY OF TRANSMISSION ELECTRON MICROSC AHA LAB NUttlER CLIENT NUMBER VOLUME SAMPLED (LITERS) FILTER AREA ARALY7ED IMAM ANALYTICAL SENSITIVITY S/HH S/CC NO. OF ASBESTOS STRUCTURES CHRY. AMPH. R0. OF R0PM5BEST0S STRUCTURES ASl C0NCEI S/HH 5/30/09 N9060I0J RBB0330A 7100 .0830 13 0.0022 1 0 0 13 5/30/81 N9060102 R8B03306 7143 .0630 13 0.0022 31 0 30 458 5/30/09 H9060103 RIB0530C 2100 .0630 13 0.0027 73 0 9 307 5/30/09 N9060104 RDD03300 2100 .0830 13 0.0077 9 0 0 109 Analytical procedures used eeet or reefed the AHERA ' Interi* Transmission Electron Microscopy Analytical Methods* protocol described in Appenda A to Subpart E of 40 CFR Part 76). Robert R. I (tin ip poti appbet o n ly io (he sam ple or tam plei, in v e sb g a ie d a n d it n o i n e c e iia n iy indicative o l the quality or co n d itio n o l a p p a re ntly Identical o r vm iiat p ro d u c o A i a n i n e la b o ia t o n e i in n report <l ju bm itte d a n d accepted lor ih e e x clu sive u ie o l Hie client to w n o m it n a d d r e n e d a n d u p o n the co n d itio n that it n n o i to be u t r d m no m ailer W iino ul prior written auiM uritation from u l Sample type! lo ia n o n t and loM ecliun protocol! are b ale d u p o n the inform ation provided b y the pei io n i lu b m iiiin g m ,rr i iim ia to rifi. w e e ip t e is ly d isclaim a n y k n o w le d g e a n d liability lot Hie accuracy a n d c o m p ie t e n e ii o f tbi| in fo rm a tio n All tight! leierved A M A An, 1090 K in g G e o rge s Post R o ad Suite 307 Edison, NJ 0 8 8 3 7 (2 0 1 )4 1 7 -0 6 6 0 F A X (2 0 1 )4 1 7 0664 Toll Free 1 (800)> 5 - J u n - 1989 12:22:10 N9060103-1A Atlantic Enviro., Inc. Vert* 100 counts Disp* 1 ZPreset* Oft' Elapsed* Integral 8 s 2-Jun-19B9 09:31:18 l-Jun-1989 16:50:35 N9060102-1B fit 1antic Enviro., Inc. Vert= 200 counts Disp. 1 Preset. ntt Elapsd= 1 -Jun-1989 16:35:39 Z- i Integral 0 l-Jun-1989 14:35:42 N9060101-1P Atlantic Enviro., Inc. Vert* 100 counts Disp* 1 2- Preset* Off Elapsed* ft Own erfCustody I Semple Pesenpoon For Afrcrwcopy Serve A M A Jholytlcol Srv(c*s o f NV/NJ, Iac SU BM IT T A L D A T A < ^ Date L/ / ) -/l-1 Bv m P r> . Job 1 O 'g Q M - 0 2 3 ? - -------------------- _ (print) Job Site t C U V C u o i W r N Com pany Name S i f r r Y iA d f lr p A -- <as" ) M nUAL h ^ l S V u ^ . j C TKaq- City '>LJ./> ^ Telephone (____i State J J 3 1 ZIP _ 0 ~ 7 y O ) U J L t O Fa* (____ Verbal Results Date ------------------ z-------------------- Z___________ Verbal Results Needed B v To W h o m _____________ _ W rm en Results Date SAMPLE DATA iNvcacrro1 f** p.o.> Company Dept/Dhrwor Attention__ Street/SFDi/Bo* , G ty _______ Telephone__ J. CERT1RCATETO CompanyNene . Dept/Dli istarr _____ In NameO f ' Street/RfD/BoK_____ C ity-------------- :--------Telephone (____ ). N 2153 (Please Refer to ths Number for Inquires) 9 6 q i Datr a ______ H P, *r<-- >- Sta te ______ ZIP -- -----)_ O PTICAL M IC RO SC O PY ELECTRON M IC R O SCO PY Number of Sam ples, Number of J Samples. L BY M ETH O D EPA Interim M eth od. BY TYPE AIRS____ BLAN KS, BY M ETH O D EPA Level II ^ BY TYPE AIRS > ^ B L A N K S NKDSH Method 7400, BULKS W IPES, AHERA BUUCS_____ W IP E S, OTHER, OTHER, OTHER, OTHER, Num ber of Sam ples b y filter Type. Total Num ber of Sam ples (All Types) Release Cnteria/Analytical Sensitivity F *W Sheet Attached' Q ves J_____ Bao LJ No LM CE i o s/cc If NO. D Mease Porosity 0.005 s/cc AHERA com plete the table below Additional $ % Asbestos sheets may c * -am (MCE) Other, attached fW A = ins.de Work Area O W A - O utside Work Area FB = Field Blank IB - Laboratory Blank FOR LA BO RA TO R Y USE.ONLY (CUSTODY) M e th o d orf Receipt: ^ e m p h ^ * & p r t s s " tMUJFtd Ex, > Wi DateYTime R e c'd 6 ^ _ L / S j O J O : I S Comments. \ 1sr Class Mart,___ O x rie rJ -OTHER '