On June 19-23, 1978 an industrial hygiene survey was conducted at the Henry Chemical plant.
The plant's program for controlling vinyl chloride and the medical surveillance program for all workers are functioning adequately.
Procedures for handling and disposing of asbestos insulation must be developed and implemented as quickly as possible, A plant-wide respirator program must also be written.
The plant management is to be complimented on the enthusiasm of its staff. I would like to thank the Henry plant manage ment for the consideration given to me during my visit and I look forward to working with them in the future.
v
cc:
A.W, J.D. N.L. D.E.
Otto Kruxnholz Kuchenmeister Giffin
T, S, Bialke Industrial Hygienist
a F G-i
4*0 2/77
USA
cn
co
CO
C:
o
BFG46069
IH Survey - Henry June 19-23, 1978
1.
RECOMMENDATIONS
1. Asbestos
Remove and properly dispose of all 2" I.D. preformed pipe insulation designated by sample #1 stored in carpenter shop as it contains asbestos.
Develop and implement asbestos insulation removal procedures requiring the use of approved respirators, wet methods, bag labeling and proper disposal (see Appendix I for example of asbestos insulation procedures and OSHA 1910.1001).
Restrict purchase of insulation to asbestos-free types.
2. Respirator Program
Develop and implement a written respirator program and provide for ongoing review of the program by placing one individual to be totally responsible for the program's maintenance and enforcement.
Provide for periodic review of the serviceability and clean liness of those respirators assigned to individuals.
Provide maintenance personnel who carry respirators with them with storage bags that can be hung on maintenance carts.
3. Install hydrocarbon and CO removal devices in breathing air lines at reservoirs leading into PVC, PC and 3114 process buildings.
4. Implement a program for periodic cleaning and maintenance of all local exhaust ventilation systems in the compounding and polymer chemical buildings.
5. Maintain a stock of toxic dust respirators and require them to be worn when compounding toxic pigments i.e., Pb, Cd, Sb pigments. If the use frequency of such pigmenCST'is increased, the compound weigh booth ventilation system must be reevaluated and increased to provide at least 100 fpm across workers breathing zone.
6. Poly Building
Repair steam and compressed air leaks in poly building.
Conduct additional noise dosimeter monitoring of baggers and others.
BFG46070
IH Survey - Henry June 19-23, 1978
O'
RECOMMENDATIONS (con't)
7. Polymer Chemicals
Clean local exhaust ventilation systems.
Develop plans to upgrade existing and provide new local exhaust ventilation at dry compound addition points and bagging operations,
3114 Process
Modify local exhaust ventilation hood over manhead to provide higher capture velocity across manhead opening.
Provide hoods and hangers at the end of flexible exhaust ducts provided for sampling point spot ventilation that will allow for easy access to sample sites.
9. Supply noise dosimeter data to the plant nurse so that comparisons with individual audiometric results can be made.
DISCUSSION AND FINDINGS
Five bulk samples of various types of insulation were collected and analyzed for asbestos (see Table I for results). Two samples were found to contain asbestos; sample #1, a preformed 2" type of pipe insulation discovered in the carpenter shop storage room and #5, a sample of insulation found in a 55 gallon drum outside the polymer chemicals building which had been removed as a result of repair work on the MBT crude reactor. The material found in the barrel was disposed of improperly and had not been wetted down upon removal.
An asbestos handling procedure similar to the one prepared by Avon Lake (Appendix I) must be developed and implemented by the Henry plant. The preformed insulation corresponding to sample #1 must be properly disposed of (see Appendix I or OSHA 1910.1001 for procedure). All pipe insulation, unless known otherwise, should be handled as if it were asbestos.
The Henry plant uses a number of respirators of different types. During my walk-through, X observed many practices such as improper storage of respirators, failure to clean respirators and nonapproved airline respirators that were in violation of OSHA. The plant needs to develop a written respirator program with responsi bility for the program assigned to one individual for the monitoring of its effectiveness. The program has to provide for the periodic review of the serviceability, cleanliness and maintenance of all respirator equipment by an individual or individuals trained in and impressed with the importance and necessity of such a program.
BFG46071
IH Survey - Henry June 19-23, 1978
3.
DISCUSSION/FINDINGS (con't)
Respirators assigned to maintenance personnel were found to be draped over the handle bars of their tool carts. Such practice
is improper as far as OSHA is concerned and will eventually lessen the service life of a respirator. Small canvas bags are being used at other plants to store respirators assigned to maintenance personnel. Avon Lake General Chemical plant obtained canvas pouches that do the job from Salem County Rehabilitation, Mannington Road, Salem, New Jersey 08079. Cost is $7.50 per pouch and they are called "canvas respirator pouch with belt".
Currently CO and hydrocarbons are being removed from instrument air at the airline stations to provide approved breathing air. Such a dispersed filtration system is hard to maintain and is expensive when replacement of many filter cartridges is required. Centralizing the production of breathing air by filtering instrument air before it enters either the PVC, PC or 3114 process areas would reduce the frequency of replacing filters and reduce operating costs. The certainty of supplying adequately filtered breathing air to all airline stations within a building would be assured. Such plans are under consideration by the
plant and are encouraged.
The local exhaust ventilation systems of both the PVC compounding building and Polymer Chemicals building were found to be in need of a clean-out. A branch of the local exhaust system over the bin in the compounding building was totally plugged. A require ment for routine cleaning of all ventilation systems was described to me. Such a procedure, to be effective, must be properly implemented and maintained to insure adequate ventilation.
The handling of toxic pigments (Pb, Cd, Sb) in the PVC compounding building is very infrequent. However, when such pigments are used, the employees must wear toxic dust respirators such as the 3M 9900. Respirators are required as the ventilation in the weigh booth and Henschel area is not adequate to control toxic dusts. The system is adequate, however, for nuisance dusts. If,the use. frequency of toxic pigments is increased to weekly, the ventilation system must be upgraded and monitoring for toxic pigments begun.
The Poly building has a potential for overexposing workers to high intensity noise. More dosimeter work is needed in this area to adequately characterize the exposure, especially for PVC baggers. Steps can be taken to reduce noise and save energy by initiating a program to plug steam leaks, compressed air leaks and sealing faulty switches and agitators, all of which are sources of high
frequency noise in the area.
BFG46072
IH Survey - Henry June 19-23, 1978
4.
DISCUSSION/FINDINGS (con't)
The polymer chemical building has numerous sources of dust exposure to both raw materials and final product at the packaging sites. Dust monitoring has not shown any overexposure to nuisance dust. Most, if not all, compounds used or bagged in the PC building are characterized as such. Even though no overexposure exists, as defined by present standards, it behooves the Henry plant to proceed with plans to upgrade existing local exhaust systems and to install additional exhaust ventilation at other sources of dust exposure; the packaging operations for example.
Steps must be taken to close up existing sources/leaks of dust as much as possible.
As noted in the 3114 process start-up review, the local exhaust ventilation drops at the sampling points are in need of modifi cation. Various suggestions have been made to provide adequate ventilation at the sample site to remove any vapors produced and yet allow for easy access to the sample site. Whatever design is decided upon will certainly provide for better conditions than now exist with the free hanging flexible ducts with no hoods or hangers. The exhaust hood over the manhead also is poorly designed. It needs to be lowered or modified to provide a higher capture velocity across the manhead. Here again, various design changes have been suggested. Any of these will do a better job. When a design is decided upon, its installation must proceed rapidly.
Noise dosimeter results are to be provided to the plant nurse so that she can compare them with an individual's audiometric examinations and properly counsel him/her on whether a hearing problem is a result of on or off the job noise exposure.
Air sampling for vinyl chloride, benzene and acrylonitrile was
performed (Table XI) . All readings were within published or
recommended standards. The plant's physical examination require
ments were reviewed and found to be in order.
--
TSB
900966SZ
BFG46073
TABLE I.
INSULATION BULK SAMPLE RESULTS Henry Plant
Sample No.
1. 2" I.D. preformed pipe insulation
2.
6" I.D,
ditto
Collection. Site
Carpenter Shop storage
ditto
3. 6" x 1%" x 32" preformed pipe insulation
ditto
4. Eagle-Picher Super 66
ditto
5. MBT crude reactor insulation
Uncovered waste barrel outside PC bldg.
Constituent Asbestos
Fiberglas synthetic fiber ditto
Rock wool Asbestos
A0Q966S2
BFG46074
Location PVC Milling PVC Milling Polymer Chemicals Polymer Chemicals
3114 Building
TABLE II.
AIR SAMPLING RESULTS Henry Plant
Type
General area
Over mill
PC operator
General area, 3rd fir. slurry tank
General area 3rd floor 3114 dryer
Sample Time
(min.)
Pollutant
284
VC
260
VC
245
Benzene
250
Benzene
PPm <.0.1
0.2 0.1 0.1
239 Acrylonitrile <o.:
800966SZ
BFG46075