1981 April 7
HTPALQNP AREA
J-6 Respirator Fit-Test
'With the increased emphasis by CSHA in the fourth quarter of 1580 for the fit-
testing of disposable respirators, the plant has elected to discontinue use of these types of respirators, in favor of the Ccmfo H with appropriate cart ridges. This policy has affected mechanics site-wide and selected employees (a phosphate sensitive individual in the Methanol Area). This group of employees are now using respirators for which they have not been fit-tasted,
although testing is due this year. It is recommended that employees not be required to wear respirators that they have not been fit-tested and trained in
the use of.,,
7-7 Self-Contained Breathine Apparatus
The pressure of the air supply cylinder of a 30-minute self-contained breathing apparatus was only 1600 psig. It is recommended that the cylinder be maintained in the full condition. A full cylinder will be one in which the pressure gauge
is the full indication range or at least within 90S of the rated tank pressure. If monthly regulator checks are responsible for lew tank pressures, it may be useful to use a spare cylinder for these inspections.
J-8 Employee Respirator Cleaning
The site uses a cleaning solution of 30? isopropyl alcohol for daily cleaning
of Individually assigned, respirators. Some locations have encountered problems
when using alcohol containing solutions, which can carnage the facepiece by
causing swelling or hardening of the robber. It is recommended that use of
alcohols should be avoided. A convenient alternative way to do intermediate
cleaning is with an aqueous clearer/sanitizer solution, e.g., Antiseptic Tcwelette, by Msd-?ak Corporation P. 0. 3ox 5^8,, Ppca, w.v. 25159*
S-9 S-10
Gloves
FVC gloves are used as protection against carbon tetrachloride, chloroform and other solvents. PVC gloves have a low breakthrough time for these solvents.
Plans to evaluate more protective gloves on basis gf.permeability data ; collected by Haskell are highly endorsed, f
Sn-m s-ccedures
The area has developed sane emergency procedures. Three different sheets
addre33 this item and different statements about personal protective equipment
are indicated, e.g., rubber gloves, PVC gloves or only protective equipment for
carbon tetrachloride. It is recamended that concise emergency spill proce
dures be develooed. They should contain beside other information the exact
types cf protective equipment that should be used in a spill situation.
Chemicals with similar properties caa-ee-gsus^ together. Sample procedures
can be provided. Other areas lik^Mcrdei, TE^need to develop similar
procedures.
DUP 0502204
DU 001867
ichcidt_________________________Field fetes rZPAICN (Cont'd.)
1981 April 7
Information on Chemical Hazards
a. Esaloyees are informed about the hazards of the chemicals they handle
annually. This training is documented with the names of the eroloyees and
the dates they received this information It is recommended that the scope
of the information on chemicals with carcinogenic or embryopctic potential
be included in the documentation.
:.
b. The Chemical Data Sheets ('used and prepared by Hypalcri Area) on carbon tetrachloride and chloroform which serves as information basis for employees do not contain information on the carcinogenic potential of these chemicals. This information should be added.
S-12 Respirators
Two face pieces of Scott Air ?aks had some soil on than/ 'It is recommended
that dirty respirators be cleaned when found during the monthly inspection. k dirty face piece was also found in the Nordel Area.
b. Breathing air stations for airline respirators are marked as such. It is recommended that the phrase 'blow out line before using mask' (Engineering `Standard S1H) be added. This appears to have plant-wide application.
NORDEL AREA
<7-13 Air-Line Respirators
The air-line respirators in the' Nordel Control Hocm are all similar in appearance and function. The approval designation on one of the units was by the Bureau of Mines 3K-19B-36.
This style of respirator was no longer approved for use past March 31, 1580, 'unless modified by the manufacturer (no modification was apparent). A similar
style of respirator was in use in the Methanol Control Room, but it carried a current approval number. 3oth styles of respirator use a quick disconnect urn which, appears to have been fabricated on site.
An approved air supplied respirator must use components and part3, which have been submitted to the NIQSH/ICEA approval organization and approved as a unit, this includes vortex coolers. Interchange of parts and substitution of other parts will void the approval.
A similar quick disconnect unit is present on the 5 7.5 and 10-minute escape respirators.
It is recommended that the air supplied respirators be inspected to assure that the entire unit is composed of approved components. In addition, the breathing air station in the Nordel Control Room should be properly identified (see
DUP 0502205
DU 001868
jam-iii-.i t ssiBHnttlisiu
?leld fetes
19Q1 Aorll 7
N'CHIZL-S (Cow'd.)
loe Machines
a. A coffee cup was being used to rerove ice frcro the ice maker. After use it was placed in the ice bin where the handle was in contact with the ics It "is recccmended that the handle not be placed in contact with the ics,
due to the potential contamination of the handle and subsequent ice contamination.
b. The ice bin is beginning to rust creating difficulties in cleaning and the
potential of rust particles in the ice. It is reccranended that the unit be cleaned and painted to eliminate the rusty condition. $
Respirators
Two out of five Scott Ska Paks were filled below the full mark. It is recom mended that the air pressure of emergency respirators be kept in the full range of the pressure gauge. The same deficiency was found at an escape pak in the
Methanol Area.
S-ls Refrigerator
Refrigerators for cooling food do not contain thermometers. It is recommended
that all refrigerators on tfcff'plant be equipped with a therrometer (not mercury
bulb) to assure that the temperature l*e kept#at or below 45F to assure proper
feed storage. >
~f
S-17
Instrument Shoo
Pans for catching mercury were installed under manometers. Various items were
stored, in. the pans. It is reconmendad that nothing be stored in their, to inpair
detection and cleanup of spills. --^
METHANOL AREA
<T-l3
Escape Respirators
a. Air purifying respi^Hors (half-mask Corafo U with ammonia cartridges) have been* placed in various areas of the Methanol Area. The Methanol Area is adjacent to the Annonia Area. Two of the respirators were dirty and the storage bag was not sealed to provide clean, uncontaminated storage. Spare cartridges were also stored in the box. It is recommended that the respirators be cleaned, stored properly and spare cartridges stored ir. a central location (in an emergency, an employee should not be concerned with, changing cartridges).
b. Since annonia is an eye irritant, the area should evaluate the need for ful face respirators in those locations that eye irritation could prevent successful escape in an emergency situation. It is recanr.endsd that the neeji fyp fun-face respirators be evaluated.
DUP 0502206
DU 001869
? Schmidt MESANCL (Cent'd.')
Field Motes
1981 April 7
S-18 Hearing Protection
a. No hearing protection is required in the Water Treatment Laboratory but is required beyond both exits. It is reconmertded that signs be posted at
both exits to remind employees that hearing protection is required when leaving the laboratory.
b. An air powered portable grinder had no indication that hearing protection
is required when it is operated. It is recommended that the noise level be evaluated and the tool be marked if the noise exceeds the aoplicable limit. #,/< ,