Meeting your steam requirements
with CONTROLLED SUPERHEAT over WIDE TOAD DANCES
METHOD of superheat control which
Boiler feedwater is diverted around the
A successfully overcomes the disadvan* economizer and passed through tubo bundles tages of methods such as damper by-pass,located in the superheater inlet header. This
"desuperheating" by spraying water into steam, and others, has been developed and applied to Foster Wheeler steam generator*.
The Foster Wheeler method operates by reducing the latent heat of the steam in the superheater inlet header. It differs from con ventional desuperheating because no water
relatively cool feedwater condenses some of the entering cleaned and dried steam. The amount of moisture entering the superheater is regulated to provide positive and accurate control of final temperature. In addition to the wide range control possible when this
is added to superheated steam. Simply, device is used, superheated steam is not con
superheating becomes a controlled operation taminated by water, and excessive metal
from inlet to outlet
stresses are avoided.
A reprint ot an article describing in detail a specific application ol Foster Wheeler condenser-type superheat control is available. Ask for B-46-20.