Document omdMQE5oZ5bO1LmXngNLLZmyD
G. llcEendry
Project Analysis
Highland Park
Director-Plant Ingireering
Corporation Hfg. Staff
Russell Street Office
/
Dececber 18, 1956 /
/
siren, isebcts or project.bewuesi res bMxz.lisiks fabrication at ciclet^d/
e wish to advise that we hare ehecked into the safety aspects of the
subject Project Request, and have discussed the industrial hygiene
problems with Don Fowler.
In our opinion, this Request provides for the aechanieal features, such as ventilation, sprinkler protection, and earbon dioxide systems that are required to sake a safe operaiion. The Industrial Hygiene Depart ment informs us that they have no objections to the installation.
In general, the operations that will be performed in the proposed brake lining set-up are very similar to sxisting operations and hazards in the Cycleweld cement production.
JvRiab
ee: L. A. Churgay D. G. Fowler
Lf U
File Memo
Plant: Eldon Avenue Axle Plant
Subject: Exhaust Ventilation and Dust Concentrations - Depart
ment 78, Brake Shoe Grinding
Date:
March 25, 1968
On March 25, 1968, the exhaust ventilation system of the brake shoe
grinders in Department 78 was surveyed. Also, samples were collected
to determine air-borne asbestos dust in the breathing zones of employees operating the grinders. The results obtained are listed on the attached data sheet.
The duct velocities recorded at the time of the survey ranged from 7500 to 11,000 feet per minute. It was determined that the quantity of air exhausted at a belt sander provided with a duct 3% inches in diameter was 435 cubic feet per minute (cfm) and the quantities of air exhausted at three Excello Brake Shoe Grinders provided with ducts four inches in diameter ranged from 745 to 960 cfm. We were informed that the grinding wheel diameters as purchased are six inches and widths are either 2 3/4 or 3 i inches. The width of the belt for the belt sanders is six inches. It was observed that the wheels were well enclosed and indraft face velocities ranging between 2800 to 5800 feet per minute were measured at the brake shoe grinders.
Air-borne dust concentrations obtained in the breathing zone of employ
ees operating the brake shoe grinders ranged from 0.2 to 1.4 millions
of particles per cubic foot of air. This indicates that the present
exhaust ventilation system# provides adequate control of this air-borne
contaminant.
Information taken from the Centri-Spray Wet Dust Collector Serial No.
AW 53861359A name plate indicates that the capacity of the collector
is 10,000 cfm air and handles a volume of 1850 gallons of water. There
are twelve machines in this location, four of which are belt sanders
for repair only, and the remainder are production brake shoe grinders.
At the time of this study the belt sanders were not utilized for any
length of time. Also, only four operators were performing brake shoe
grinding operations.
LR: hm cc: N. A. Trombley
L. Redmond
Data Sheet Elc'on Avenue Axle Plant
Exhaust Ventilation
Location
Duct Velocity
Feet Per Minute
Volume
Cubic Feet
Per Minute
Department 78:
Brake Shoe Grinders - Bay R-15 through Bay R-19;
XLO Machine #550134, 4" diameter XLO Machine #550141, 4" diameter XLO Machine #550136, 4" diameter Repair Belt Sander, 3.25" diameter
9000 11,000
8500 7500
785 960 745 435
The above readings were obtained with
Alnor Velometer, Type 3002.
Dust Concentrations
Location
Threshold Limit value
Department 78:
XLO Machine #550134, XLO Machine #550135, Repeat sample
XLO Machine #550136,
Repeat sample
XLO Machine #550141,
breathing breathing
breathing
breathing
zone zone
zone
zone
sample sample
sample
samp le
Millions of Particles Per Cubic Foot of Air
5.0
0.2 0.6 0.5 1.6 1.2 0.2
The above samples were collected with Mine Safety Appliances Company Midget Impinger Flasks and Pump.
Total Weight of Dust
Location
Department 78:
XLO Machine #550135
XLO Machine #550141
Milligrams Per
Cubic Meter of Air
1.2
0.8
The above samples were collected with a Unico Model 30 Pump using glassfiber filters.
t
Hr. K. M. Hayes
Manufacturing Mgr Chemical Div
Mr. L. Redmond
Indust. Hygiene
Alfl-BOfiWB AS8SS7VS DVST SXHG&TMTim.^-DEPARTMENT-7ZQQ
May 27, 1963 Trenton Snginf Highland Park
As requested on May 22. 1963, samples were collected to determine the air-borne asbestos dust concentrations created by the sawing and forming of brake linings. The exhaust ventilation system was also checked at this time.
j.
The results obtained, which are listed on the attached sheet, indicated that the dust concentrations were at acceptable levels and that the exhaust ventilation system was functioning properly.
LR:slh
cc: B. J. Sauber, M.D R. H. Weidner
Louis Bedmo Senior Industrial Hygienist
pm jgflfigr
ASfi-BQfifflE A8QSS.TPS CCKCmRATIOKS
fkA'i ^
3
iQCMtlflB
Threshold limit val^e At #1 saving machine - removing brake shoes At #2 saving machine - removing brake shoes At both Bolling Machines
Results in Millions of Particles Per Cubic Foot
Pi .Air. ------------------------------
5.0 0.4 0.3 1.0
The above samples were collected vith a Mine Safety Appliances Company's Midget Xmpinger.
Location
At #1 sawing machine At *2 sawing machine
YflBtilMtiPa
Results in Feet POT MiOUtfl-----------
500 - 1100 700 - 1200
The above measurements were made with an Alnor Velometer. Serial #2100.
xaaa
PLANT ANALYSIS FOR
/) S>Q-~
DATE TAKEN BY Z <S .
<r- -3 -
i-'