Document omY3wG0ra62gLoZnrDbJLJK97
bcc: AG Fades
. GR Buchanan
_________
f7 2nd Street~-~Don~Roush
; NEW YORK - H Gilbert
' CHICAGO - DL Hosmer
. CHICAGO - AH Kempel
ANNISTON - Owen Dolin
. April 20. 1965
Mr. P. D. Heniee, Production Supervisor '
:
; L-ever Bros. Company
;! ;
1200 Calumet Avenue
/ ;. :
'
Hammond. Indiana
'A
.' -
.
/ : .
Bear Pete:
Bavc Hosmer, our Fluid Specialist for your area, and I will be
visiting with, you as planned, Friday morning, April 30.
''
Pete, regarding the deposit sample you sent Gwen Bolin, while
I haven't seen it, my guess is that it is iron chlorides. Y/c see
it occasionally when there has been some fluid degradation with
the subsequent release of hydrogen chloride. The gas dissolves
' in moisture in the expansion tank, forming an acid which attacks
- the -steel. Iron chloride i formed. The areas where you have
found the crystals arc relatively cool and the hydrogen chloride/
. water will condense at those points. Did you examine the flange
areas for signs of corrosive attack? Keeping the esqiansion tank
hot (approximately 215 - 220F. ) may be a solution to the problem.
However, before we make any recommendations let us see if Owen
Dolin has any comments on the nature of the deposit cample. Also,
v;e will have an opportunity to review the system next week to fill
' . in the details. .
,'"
.
I'm locking forward to visiting with you ivgain. It has been about two years since I was in Hammond.
.
Best regards. . ...
-
.' Cordially,
S. Shaw . Karkct Specialist Functional Fluids
DSW 435101
STLCOPCB4088162