Document omVdQn3xj3ypBrgaqkqo85v67

Hovonbcr 11 1971 Dr. r. A. Gunther Deportment of Entomology University of California Riverside, California 9? 507 Dear Dr. Gunthert Monsanto's Boh Conkin has informed mo of your interest in soil degradation of polychlorinated biphenyls (PCB). You probably hnve by now received a snrnple of Aroclor 1254 for une in your studios. As you know this commercial mixture contains tho higher chlorinated isomers. You may be interested in concurrently studying the degradation of a mixture which has predominately the lower chlorinated ieomars, such ns Aroclor 1721. If so, please lot me know and I will arrango for the shipment of a sample to you. Responding to your inquiry relating to Monsanto's interest in a PCD story for publication in Ronlduo eyiews, wo would profer foregoing any doeision regarding publication until final results from study programs now underway are available. X am very interested in nil studies involving polychlorinated biphenyls and hope that you will be able to share your test results as thay develop. If I can be of further service please let me know. Sincerely, WBP/er . V?, B. Papagaorgo Manager Environmental Protection beet R. A. Conkin - VIA *. E. Keller W. R. Richard - T3A E. S. Tucker E. P. Wheeler - A2SA - 1760 - 1760 093506 TT !.f A * ,'t <f 7 1 a.a., operated under a nitrogen carrier gas flow rate of 10-15 ml/min). The Apiezon column was programmed from 80 to 290C at the rate of 6C/ min; the FFAP col. was programmed from 120 to 270C at the same rate. The instrument used was a Varian Aerograph (Models 650D, 1200, and 1700) equipped with FID, (2) as above but using a Hewlett-Packard 700 instr. and the Apiezon L col. (3%), and (3) 1.3 m x 2.2 mm, i.d., s.s. col. packed with Z% Apiezon L on 80-100 mesh Chromosorb W, operated at 150 to 180*0 (programmed at the rate of 6*C/min) under a nitrogen carrier gas flow rate of 10 ml/min, using a Hewlett-Packard 5750 instr. equipped with an FID. The results obtained were interr.alibrated to determine the accuracy and precision of hydrocarbon analyses of such samples by GC. Retention data: chromatograms, p. 133. 89-58b-51b No. 74-0337 CHL0RDANE RESIDUES IN MILK AND FAT OF COWS FED HCS 3260 (HIGH-PURITY CHLORDANE) IN THE DIET H. W. Dorough and R. W. Hemken (Univ. of Kentucky, Lexington, KY) Bull. Environ. Contain. Toxicol. JL0, No. 4: 208-15 (Oct., 1973) Extracts of cow's milk or fat were analyzed by GC using a Varian Aerograph Series 1700 instrument equipped with an electron-capture detector and a 6 ft x 2 mm glass coLuran packed with 4% SE-30 and 6% QF-1 on 80-90 mesh Anakrom ABS, operated at 200C under a nit rogen carrier gas pressure of 18 psi. Retention times, in minutes, for the compound considered for quantitation were: heptachlor, 6.0; oxychlordane, 10.4; heptachlor epoxide, 11.1; a-chlordane, 13.4; Y-chlordane, 12.1. 89-61b 0337 No. 74-0338 OXIDATIVE DECOMPOSITION OF ETHYLENE-BIS-DITHIOCARBAMATES J. W. Hylin (Dept, of Agr. Biochem., Univ. of Hawaii, Honolulu, HI) Bull. Environ. Contain. Toxicol. 10, No. 4: 227-33 (Oct., 1973) Ethylene diamine was determined by GC of the trifluoroacet-di-araide derivative using a 6 ft col. containing 80-100 mesh Chromosorb W coated with 2% DEAS and operated at 190C with electron-capture detection. Elemental sulfur was estimated on a benzene extract by GC using the same col. and conditions but with sulfur-specific flame-photometer detection. No retention data. 89-88-60a-59-39 0338 No. 74-0339 DISTRIBUTION OF A POLYCHLORINATED TERPHENYL (AR0CL0R 5460) IN RAT TISSUES AND EFFECT OF HEPATIC MICROSOMAL MIXED FUNCTION OXIDASES J. Carlos Sosa-Lucero and F A. de la Iglesla (Warner-Lambert Res. Inst., Sheridan Park, Mississauga, Ontario, Canada); Gordon H. Thomas (Ontario Res. Foundation, Pesticide and Trace Anal. Lab., Sheridan Park, Ontario, Canada) Bull. Environ. Contam. Toxicol. H), No. 4: 248-55 (Oct., 1973) HONS 093507 ^0339 ) 15 Hexane extracts of rat tissues were analyzed for polychlorinated terphcnyl by GC, using a Varian 12Q0 series lnstr. equipped with a 6 ft X 1/8 in., i.d., colled glass column packed with 3X OV-210 and 3% SE-30 (ultraphase) on 60-80 mesh DMCS-treated Chromosorb W, operated at 255C under a nitrogen carrier gas flow rate of 25 ml/min. Retention data: chromatograms, p. 252. 89-61a-54b 0340 No. 74-0340 0XYCHL0RDANE RESIDUES IN HUMAN ADIPOSE TISSUE Francis J. Biros and Henry F. Enos (U.S. Environ. Protection Agency, Primate and Pesticides Effects Lab., Perrine, FL) Bull. Environ. Contain. Toxicol. 10, No. 5: 257-60 (Nov., 1973) Oxychlordane, BETA-HCH, p,p'-DDE, o,p'-DDT, and p,p'-DDT (organochloride pesticide) residues in human adipose tissue were analyzed by GC on (a) a 1.5% OV-17 column and (b) a 1.95% QF-1 column with 80-100 mesh silanized support operated at 200C under a nitrogen carrier gas flow rate of 60 ml/min. Relative to aldrin, oxychlor dane had a retention time of 1.38 and 1.56, respectively on these two cols. IR and MS were used to assist in the identifications. Retention data: chromatogram, p. 258. 89-88-61b-35b-35a / 0341) No. 74-0341 V __ ^POLYCHLORINATED BIPHENYLS- IN THE SEASTAR Acanthaster planci L. R. McCIoskey (Dept, of Biology, Walla Walla College, College Place, WA) and Karl H. Deubert (Lab. of Experimental Biology, Uuiv. of Massachusetts, East Wareham, MA) Bull. Environ. Contain. Toxicol. 10, No. 5: 261-64 (Nov., 1973) Tissues were extracted, cleaned up and analyzed for polychlorinated biphenyls by CC using a Varian 2700 instrument equipped with a 5 ft x 1/8 in., s.s. col. packed with 3% QF-1 on 100-110 mesh Anakrom ABS, operated at 190*C under a nitrogen carrier gas flow rate of 25 ml/min. Retention data: chromatograms, p. 263. ' 89-61a-54b ) No. 74-0342 CONFIRMATION OF HEXACHLOROBENZENE BY CHEMICAL REACTION Bruce E. Baker (Centre National de Recherches Agronomiques, Versailles, France)(Present address: Faculty of Agr., McGill Univ., McDonald College, Montreal, Quebec, Canada) Bull. Environ. Contain. Toxicol. 10, No. 5: 279-84 (Nov., 1973) Hexachlorobenzene, 1,2,3,5-tetrachlorobenzene, and pentachlorobenzene were separated by GC using an Aerograph 600 lnstr. equipped with a 5 ft x 1/8 in. Pyrex col. packed with 80-100 mesh HMDS-treated Chromosorb W, coated with 5% QF-1, operated at 130*C. Retention data: chromatograms, pp. 280-284. 89-61a-54a 16 MONS 093508 filter disk in the end of the col. A hand-operated device for thii; Is des cribed anil il lus t raced. For on-cu.l. inject u>n, only the det nc tor-end <; [),n col. is sealed. The device can be easily assembled from a few readily ac.iil-able components. Derailed drawings are available from the author. The device operated effectively and simply in one year's use. 91-B5a 0922 No. 74-0922 DISTRIBUTION OF DJELDRIN IN THE TURTLE James E. Pearson, Kathleen Tinsley, and Thomas Fernandez (Dept, oi Pham,., lxniisiana State Univ., Medical Center, New Orleans, LA) Bull. Environ. Contain. Toxicol. N. 6: 360-64 (Dec., 1973) The concentration of dieldrin in the plasma and various tissues of turtl' rwas estimated with a Micro-Tek 220 GC. The samples were chromatographed on a col. of 1.5% OV-17/1.95% QF-1 on 100-120 mesh Chromosorb W HP, and on a col. of 4% S]>30/6% QF-J. on 80-100 mesh Chromosorb W HP. Col. temp, was 200C; the detector was an electron-capture, parallei-plate (tri.tium-foi J source) detector. Under these conditions dieldrin had a. retention time relative to aldrin of 2.40 on the OV-17 and 2.15 on the SE-30 col. No retention data. 89-61b ( 0923 N No. 74-0923 _ POLYCHLORINATED BIPHENYLS IN SEA BIROS FROM ASCENSION ISLAND, SOUTH ATLANTIC ~ OCEAN David V). Johnston (Dept, of Zoology, Univ. of Florida, Cainr.vi 1 ] e, FI.) Bull. Environ. Contam. Toxicol. 1_0, No. 6: 368-71 (Dec., 1973) Polychlorinated biphenyls in liver, fat, and brain samples of the birds were extracted in hexane and analyzed by GC, using a Varian 2100 instr. equipped with a 6 ft x 1/4 in. glass r.ol. packed with 6.4% OV-210 and 1.6% 0V-17 on Chromosorb W, operated with a tritium electron-capture defector. A second glass col. packed with 1/5% OV-17 and 1.95% QF-1 on Gas Chrom Q of the same size was used for confirmation. Col. temp, were 200C, flow rate of the nitrogen carrier gas was 40 ml/min. No retention data. 89-61a-54b , 0924 L .. , No. 74-0924 PHOTODECOMPOSITION OF CHLORINATED BIPHENYLS AND DIBENZOFURANS Donald G. Crosby and Kenneth W. Moilanen (Dept, of Environ. Toxicol., of California, Davis, CA) Bull. Environ. Contain. Toxicol. TO, No. 6: 372-77 (Dec., 1973) Univ. Chlorinated biphenyls were irradiated, and the reaction mixture wss analyzed by CC on a 180 cm x 0.2 cm col. packed with 2% Carbowax 20M on 60-80 mesh Chromosorb G, operated at 150-250C (programmed at the rate of l0C/min). A thermal conductivity detector was used. Fractions were collected from the effluent gas in glass capillary tubes, purified by rechronaf.ography, and their spectra compared with those of authentic specimens. For MS, the collected 10 MONS 093509 fractions were rochromatographed on a 180 cm >: 0.2 cm col. packed with 27 OV-1 on 60-80 mesh Chromosorb G, operated at 150-250C (programmed at the rate of ]0C/min), detected with a Finnigan 3000 MS detector. The chlorinated dibenzofurans were handled similarly, except that the GC col. contained 57,; Sl~30 (195<'C, electron-capture detector) or 5% XE-60 (190C, FID). Tlie photodecoieposition products were mainly of the reduced and hydroxylntod type. No retention data. B9-88-61a-56c-54b-35b No. 74-0925 SOME CONSIDERATIONS OF THERMIONIC RESPONSE XN GAS CHROMATOGRAPHY Shun Araki, Shigetaka Suzuki and Masaaki Yamada (Dept. Ind. Chcm. Tokyo Metropol. Univ., Japan) Bunscki Kagaku 22, No. 9: 1228-30 (Sept., 1973)(In Japanese) Fac. Eng. 0925 Hie response of the thermionic detector (TCD) to hetero-orgnnic compds. was studied by using four different types of detector. The effect of hetc.roorganic compds. on the ionization of alkali metals In the upper flame was investigated by using detector type A. Ion currents caused by ionization of alkali metals were measured in the presence or absence of certain hetero- organic compds. eluted from the col. The effect of hetero-organic compds. on the volatility of NaCl coated on a Pt-coil was investigated using detector types B, C, and D. The Pt-coil was heated by an electric current except when using detector type D. Enhancement of the volatility was estimated by measuring emission intensity of Na in the resonance line. Effects of a col. effluent, of its combustion products, and of chemical species produced during the combustion, on the volatility of NaCl were studied by using detectors type B, C, and D respectively. The results of the studies are tabulatedj p. 1229-30. 91-89-81-67 No. 74-0926 0926 BUTYL ESTERIFICATION FOR SIMULTANEOUS DETERMINATION OF VOLATILE AND NONVOLATILE ORGANIC ACIDS BY GAS CHROMATOGRAPHY. STUDIES ON THE ANALYTICAL METHODS FOR ORGANIC ACIDS IN FOODS. PART IV. Ichiji Yamashita, Taro Tamura, Seiji Yoshikawa and Shigeji Suzuki (National Food Res. Inst. Min. Agr. and Forestry, Tokyo, Japan) Bunsek.t Kagaku 2_2, No. 10: 1334-41 (Oct., 1973)(In Japanese) A method is presented for the simultaneous GC determination of volatile and nonvolatile organic acids. An aqueous solution of the acids is neutralized with NaOH and evaporated to dryness. The residue is csterified with a mi>:L. of butanol, concn. l^SO^ and anhydrous Na2SO^ and refluxed. After esterification, 5 ml water is added and the esters are extracted 4 times with n-hexane. The hexane layer is transferred to a flask containing n-dodecane as internal std. and the flask is filled to volume with n-hexane. All traces of ll^SO^ and water are removed with anhydrous sodium carbonate. The hexane solution is then anal, by GC. Instrument.: GC-4B Detector: FID MQNS 093510 n No. 7/1-0934 ( 09 34 AQUEOUS SOLUBILITY, ADSORPTION AND VAPOR BEHAVIOR OF POLY CHLORINATED v------ - BIPHENYL AROCLOR 1254 Rtzwanul Haque, David W. Schmedding, and Virgil II. Freed (Dept, of Agr. Ghent. and Environ. Health Sciences Center, Oregon State Univ. , Corvallis, OR) Environ. Scl. Tochnol. ji, No. 2: 139-42 (Feb., 1974) The polychlorinated biphenyl Aroclor 1254 in water extract was analyzed by GC, using an 8 ft x 0.043 in., i.d., s.s. col. packed wiLh 7% DC-11 on 100-L2U mesh Chromosorb W HP, operated at 200C with an electron-capture detector. Isomers containing different numbers of chlorine atoms respond differently to the electron-capture detector; thus, a correction was needed to qunntitizo the data. The differential response for the various chlorine-containing isomers was referenced relative to p,p'-DDE. The final concentration of poly chlorinated biphenyls was determined by comparison to a known standard. Retention data: Chromatogram, p. 140. 89-61a-54b-48 No. 74-0935 CAS CHROMATOGRAPHIC ANALYSIS OF Cg - C18 HYDROCARBONS IN PARIS AIR Alain Raymond and Georges Guiochon (Lab. de Chimie Anal. Physique, Fcole Polytechnique, Paris, France) Environ. Sci. Technol. J3. No. 2: 143-48 (Feb., 1974) 09'3j GC/MS analysis revealed more than 70 peaks. The trapped hydrocarbons were analyzed on a 100 m x 0.4 ram, i.d., col. coated with QV-101, operated at 20-250C (programmed at the rate of 2C/rain) with an FID. For identification purposes, the col. was coupled to a TSN 205 SE mass spectrometer (Thomson) in which the sweeping rate is one mass decade per second, the resolution is about 400 at mass 170, and the ionization voltage is 70 eV. The mass spectro meter is directly connected to a computer for real-time acquisition of the spectra. Retention data: Chromatograms, pp. 144-47. 91-90-89-88-78-70-64-54-53-5251-35b No. 74-0936 RATE MODEl- AND MECHANISM OF LIQUID-PHASE OXIDATION UK PROPIONALDEHYDE C. V. Gurumurthy* and V. M. H. Govindarao** (Dept, of Che.m. Eng. , Indian Inst, of Sci., Bangalore, India)(Present addresses: *Dept. of Chem., Univ. of Southampton, Southampton, England; **Inst. fur Systcmdynamik and Regel- ungstechnik, Stuttgart Univ., Stuttgart, West Germany) Ind. Eng. Chem. Fundamentals 1^3, No. 1: 9-17 (Feb., 1974) 093b The liquid-phase oxidation of propionaldehyde to propionic acid in the presence of manganese propionate catalyst in a sparged reactor was investigated. The reaction mixture was analyzed by GC, using the method described by the authors in (Indian J. Technol. JI), p. 183, 1972). The GCli-2 GC employed was equipped with a thermal conductivity detector and a 1 m x 6 mm, i.d., s.s. col. packed with silicone grease on Celite, operated at 130C under a flow of hydrogen carrier gas. No retention data. 89-58b-56a MGNS 093511 15 No. 74-0040 KINETICS OF THE OXIDATIVE DEHYDROGENATION OF BUTENE TO BUTADIENE OVER A FERRITE CATALYST John S. Slerrctt and Howard G. Mcllvried (Gulf Res. and Develop. Co. , Pittsburgh, l'A) lad. Eng. Chcm. Process Design Develop. _1_3, No. 1: 54-59 (Jan., 1974) On-stream gas chromatographs provided an immediate analysis of the off-gas from the experimental setup in which butene was oxidatively dehydrogenated over a zinc-chromium ferrite catalyst. The two chromatographs provided complete analysis. In one chromatograph, a col. packed with 2-cthoxyethyL sebacate on Chroinosorb P separated nitrogen plus oxygen, carbon dioxide, butene isomers, and butadiene. In the other chromatograph, a col. packed with molecular sieve partitioned nitrogen and oxygen. No retention data. 90-89-70-50-49 0<)/, 0 No. 74-0941 BUTANE-1,4-DL01. FROM HYDROLYTIC REDUCTION OF FURAN James M. Watson (Cosdcn Oil and Chcm. Co., Big Spring, TX) ind. Eng. Chcm. Prod. Res. Develop. 1^, No. 4: 310-11 (Dec., 1973) 0941 The preparation of butane-1,4-diol via the hydrolytic reduction of furan over Raney nickel catalyst was investigated. Reaction mixtures were analyzed by a GC equipped with an FID and a 3 ft x 3/8 in. glass col. packed with 3X OV-210 on 45-60 mesh a.w., DMCS-treated Chromosorb G. Product identifications were carried out by comparison of retention times and IR spectra of authentic materials. No retention data. 89-88-55c-35a No. 74-0942 THERMAL REACTION OF 1,5-HEXADIENE. MECHANISM PROPOSAL Daisuke Nohara and Tomoya Sakai (Dgpt. of Chera. Reaction Eng., Fac. Pharmaceutical Sciences, Nagoya City Univ., Nagoya, Japan) Ind. Eng. Chcm. Prod. Res. Develop. 1_2, No. 4 : 322-25 (Dec., 1973) of The gaseous reaction products (including ethylene, propylene, 1-butene, butadiene, 1-pentone, cyclopentenc, cyclopentadiene, 1,3,5-hexatriene, 1,3-cyclohexadiene, and benzene) were analyzed by GC. Two instruments, equipped with FIDs, were used. The capillary cols. (50-m) were coated with oqualcne and di-n-butyl raaleate, respectively, and were operated at 50C and 0C. No retention data. 89-54a-52-50 0942 No. 74-0943 PHOTOREDUCTION OF 4,4'-DICHLOROBIPHENYL Gerald D. Nordblom and Larry L. Miller (Dept, of Chem., Colorado Fort Collins, CO) J. Agr. Food Chem. 2^, No. 1: 57-58 (Jan.-Feb., 1974) State Univ., 0943. Photolysis of 4,4'-dichlorobiphenyl at 3100 A light yielded 4-chlorobiphenyl. MONS 09351^ 17 The reaction mixture was analyzed by GC using a Bemlix 21J.0 instrument equipped with an electron-capture detector and a 6 ft x 1/4 in. Teflon-lined aluminum col. packed with 5% 0V-1 on 60-80 mesh Chromooorb W, operated at 1 8001: under i carrier gas flow rate of 33 ml/min. Preparative collection was performed in an F ( M Hewlett-Packard 3730 instr. equipped with a thermal conductivity detector and a 6 ft x 1/2 in. aluminum col. packed with 5% SE-30 on 60-80 mesh Chroroosorb W, operated at 230C under a carrier gas flow rate of 30 ml/mir. MS was used to assist in the identification. No retention data. 8 9-8 8-6 la-3 4b-331) 0944 No. 74-0944 INSECTICIDES IN THE TISSUES OF FOUR GENERATIONS OF RATS FED DIFFERENT DIETARY FATS CONTAINING A MIXTURE OF CHLORINATED HYDROCARBON INSECTICIDES Mildred Adams (Nutrition Inst., Agr. Res. Service, USDA, Beltsville, MO), Francis 15. Coon (Chem. Dept., WARF Inst., Inc., Madison, Wl), and C. E. Poling (Res. and Develop. Center, Swift and Co., Oak Brooks, IL) J. Agr. Food Chum. 2^, No. 1: 69-75 (Jan.-Feb., 1974) Tissue extracts were cleaned up and analyzed by GC for DDT, DDE, DDD, dieldrin, lindane, DHC, hcptaehlor epoxide, methoxychlor, and Perthane. The analyses were carried out in a Barber-Colman 5360 pesticide analyzer, equipped with a electron-capture detector and a 4 ft x 4 mm glass col. packed with 5% DC-200 on 80-100 mesh Crompert XXX, operated at 200C under a nitrogen carrier gas flow rate such that p,p'-DDT had a retention time of 6-8 mins. No retention data. 89-61b 0943 No. 74-0945 GAS CHROMATOGRAPHIC ANALYSIS OF METHOMYL RESIDUES IN SOIL, SEDIMENT, WATER, AND TOBACCO UTILIZING THE FLAME PHOTOMETRIC DETECTOR Robert C. Reeves and Donald W. Woodham (Plant Protection and Quarantine Programs, Brownsville, TX) J. Agr. Food Chem. 2_2, No. 1: 76-78 (Jan.-Feb., 1974) The dichloromethane extracts of soil, sediment, and water, and the dichlovomethanc/benzenc extract of tobacco are analyzed for methomyl (S-methyl-N(/methylcarbamoyl/oxythioacetimide; Lannate) by GC using a Tracer MT-220 instr. equipped with a flame photometric detector with a 394-micrometer sulfur interference filter and a 6 ft x 1/4 in., i.d., glass col. packed with 10X DC-200 on 80-100 mesh Chromosorb W HP, operated isothermally at 1408C under a nitrogen carrier gas flow rate of 80 ml/rain. Linearity range was between 5.0 and 30.0 ng of methomyl; detection limit ranged from 0.05 ppm in soil, sediment, and tobacco to 0.01 ppm in water. Retention data: Chromatograms, pp. 77-78. 89-61b 0946 No. 74-0946 AN INTEGRATED METHOD FOR TRIFLURALIN, DIPHENAM1D, AND PARAQUAT IN SOIL AND RUNOFF FP^M AGRICULTURAL LAND William R. Payne, Jr., and John D. Pope, Jr., and Jacquelyn E. Benner (Southoas Environ. Res. Lab., U.S. Environ. Protection Agency, Athens, GA) J. Agr. ' uod Chem. 2_2, No. 1: 79-82 (Jan.-Feb., 1974) 18 MQNS 093513 products of retention time and peak height. Instrument: Becker (Delft, Netherlands) Detector: FID Col. L/d: 4 m x 4 mm, i.d., A1 col. Stat. ph./concn.: (I) ]5% I.AC-1 -R-296; (II) 15% Carbowax 400 Support/raesh size: (I) 60-80 mesh a.w. Chromosorb W; (II) 70-80 mesh a.w. DMCS Chromosorb W Carrier gas/flow rate: N2 , 30 ml/min Oper. temp.: Col. 60, injection 70, detector 120C Retention data: Chromatogram, p. 313 Compds. sepd. : (By peak component number): 4. acetaldehyde, dimethyl sulphide; 5.furan; 6,ethyl formate, 2-mcthylpropanal; 7. 2-propanone; 8. 2-methylfuran; 9. ethanol, ethyl acetate, 1,1-diethoxyethane; 10.1-propanol, 2,3-butancdione; 12. 2-methyl-l-propanol, dimethyl disulphide; 13.unknown; 14. 3-methyl-l-butanol 89-63-48 No. 74-1042 RESIDUE ANALYSIS OF CHLORINATED PESTICIDES AND POLYCHLORINATED BIPHENYLS IN KISH AND WATERS. REPORT MO. I M. Eichner (Reg. Chem. Res. Inst. Offenburg, W. Germany) Z. Lcbensm. Untersuch. Forsch. 151, No. 6: 376-83 (1973)(In German) Ac 1042 V, GC was employed for the residue anal, of chlorinated pesticides and poly chlorinated biphenyls (PCB) in fish and waters. The pesticides are extracted with n-hexane and the extract is purified. The purified extract is sepd. by GC using several cols. (Cols. A-D). In a case where the sample contains both chlorinated hydrocarbons and PC&'s these are sepd. from each other on a Fiorisil col. The Florisil col. is eluted with 200 ml n-hexane, followed by 150 ml n-hoxane-diethyl ether, 1:1. The hexane eluate (containing the PCB'e) and the hexane-diethyl ether (containing the chlorinated hydrocarbons) are each anal, by GC on the 2% SE-30 col. employing an ECD. Instrument: Hewlett-Packard dual col. Model 5750G Detector: Dual FID (one of which is a P-detector Model 15110A) or ECD Col. L/d: 2 a x 1/8 in. , glass Stat. ph./concn.: (I) 2% SE-30; (II) 5% SE-30; (III) 5% QF-1; (IV) 5% XE-60 Support/mesh size: Not specified Carrier gas/flow rate: He, 50 ral/min Oper. temp.: 210C Retention data: Chromatograms, p. 377-78. 89-64-6lb-6la-54b No. 74-1043 COMPARISON OF FOUR METHODS OF ESTERIFICATION WITH THE FATTY ACIDS FROM "VERNIX CASEOSA" AS TEST SUBSTANCES G. Reichniann, D. Jakobza, and P. Schulze (Hautklinik, Humboldt, Univ. (Charite), Berlin, Germany) Z. Med. Labortech. 12, No. 5: 233-40 (1971) (In German) MONS 093514 1043 57