Document omMoZzGQXv24k7pD9Qo5kb99r
INTERNAL I CORRESPONDENCE
UNION CARBIDE CORPORATION TECHNICAL CL-NTEB
PO BOX B3S1. SOUTH CHARLESTON, WV 25303
T cr (Nome!
LCCDC'O' ArHt*
A. F. Terry 704 511
Copy co
C. P. Maxwell - 701/2 R. G. Rowe, M.D. - 791 C. L. Ruddle - 704 R. E. Sergent - 704
Date U* -g.-iecng Oepr, Are& Subiec*.
February 18, 1987 EM&TS - HS&EA Industrial Hygiene Asbestos Exposure Monitoring
Attached are the results of the Asbestos exposure monitoring performed on F. R. Creech on February 10, 1987. He was monitored while
stripping 2 Reactor Heaters from 770-237 Autoclave Lab using glove bags. The
stripping was done in a designated room, located in Building 777. He also spent approximately 3 hours in Building 740 fan loft.
He was equipped with disposable coveralls and an AO R57-A HEPA filter, half-face carrtridge respirator.
The exposure monitoring results indicate that the levels were well below the 0.1 fiber/cc Action Level, established by OSHA for an 8-hour workday (TWA8).
Please notify F. R. Creech of his exposure monitoring results as soon as possible. Please have him sign and date this report and return to M. A. Patel at Building 701-330.
If we can be of further assistance, please call us on extension 4779 or 3750.
WORK BY:
APPROVED BY:
Vance F. Stover
Attachment
VES:MAP:rab 211 IP
y^j .A- -
Manhar A. Patel
UCC 024807
ASBESTOS EXPOSURE MDNIT0RIN5
Date 2-10-87
Sanple Type/ Employee Name
Personal/ F. R. Creech
Sanpling Time
Air Cone Fibers/cc
7 hrs 33 min
0.011
Fibers/cc 0.0104
COMMENTS
Collected viiile stripping 2 Autoclave heaters, frem 770 Autoclave Lab, and while working approx. 3 hours in Building 740 fan loft.
AS8ESIOS Permissible Exposure Level
TWAq
0.2 fibers/cc
Action Level 0.1 fibers/cc
OSHA
2111P
UCC 024808