Document om2VMeYoZbRe2yXrMxYeZkxjw

Boilers Oil City- BoilerWorks V Oil Citij-- ..... .L -------- - New York, N. Y., 501 Fifth Ave. Pittsburgh. Pa.. 1116 House Bldg. Atlanta, Ga.. 202 Red Rock Bldg. Baltimore, Md., Whitaker Bldg. Indianapolis. !nd.. 117 East Michigan St. Richmond, Va., American National Bank Bldg. Detroit, Mich., 715 Donovan Bldg. Chicago, III., 19 W. Jackson Blvd. Los Angeles. Calif.. 1003 Union Trust Bldg. Charlotte. N. C.. 225 Latta Arcade Cincinnati, O., S. W. Cor. 3rd and Walnut Sts. Shreveport. La.. P. O. Box No. 298 Boilers The Wm. H. Page Boiler Co. 200 Madison Avenue, New York Boston, 123 Beverly Street Brooklyn, 98--49th Street Philadelphia, 1126 Washington Avenue Washington, 1117--15th Street, N.W. Cleveland, Rose Building Meadville, Pa., Factory Makers of Boilers for more than 70 Years "OH City" Smokeless Boiler "OIL CITY" low pressure boilers are offered to the trade as the last word in "Heating Economy" comprising in one unit all the elements of a modern plant for steam or hot water heating, especially adapted for Schools, Office Buildings, Hotels, Churches, Club Houses, Hospitals or for any purpose where the service of a universally recognized fire box boiler of high merit is desired. "OIL CITY" boilers are designed and constructed to meet all requirements of modern engineering as formulated by the American Society of Mechanical Engineers, the boiler laws of the various states and cities, and are backed by 35 years of suc cessful practical experience. Description--"OIL CITY" boilers are built in smokeless and straight draft types for portable and brick settings, self con tained with all steel construction thor oughly braced, stayed, inspected, and tested for 15 lb. working pressure. These boilers have large fire boxes thereby insuring ample combustion space in which heat-giving gases and air freely mix before entering tubes. The arrangement of tubes in relation to shell allows free circulation of water at all times, together with large steam space, insuring dry steam and steady water level. " D" Type Boiler The above view shows the new "D" type residential boiler built in capacities 400 to 2000 sq. ft. direct steam radiation. Send for Circular H-23. Ratings--Ratings are very conservative, only such parts of the boiler coming in actual contact with passage of the hot gases, and lying below the zone of normal water level being considered as heating surface. Equipment--Equipment with all boilers includes, in addition to complete set of shaking grates, all the necessary castings, safety valves, steam gauge, water column, etc., required for a complete installation. Oil Fired--Where oil is used exclusively we recommend our new Series 1900 Port able Return Tubular Fire Box Oil Burning Boiler. Complete specifications and measurements shown in Circular H-22. Every "OIL CITY" boiler bears the official stamp of the A. S. M. E. Boiler Code, indicating the pressure at which the boiler may be worked. At a small increase in cost "OIL CITY" boilers are furnished, braced and stayed, for a safe working pressure of 100 lb. Complete specifications, measurements and weights shown in Catalog H-9. 554 Monarch Water Tube Monarch Sectional Steam and Water Boilers Rating No. Sq. Ft. Steam 4-22 5-22 5-22 7-22 4-28 5-28 6-28 7-28 8-28 9-28 5-40 6-40 7-40 8-40 9-40 10-40 11-40 12-40 6-60 7-50 8-50 9-50 10-60 11-60 12-60 15-50 14-50 15-60 16-60 17-60 18-60 19-50 20-60 850 1075 1300 1525 1600 2100 2600 3100 3600 4100 3400 4200 5000 5800 6600 7400 8200 9000 6600 8200 9800 11,400 13,000 14,600 16,200 17,800 19,400 21,000 22,600 24,200 25,800 27,400 29,000 Rating Sq.Ft. Water - (Size of Grate Inches (Full Height Area Overall of Grate Inches Sq. Ft. Steam Width Overall Inches Steam Height Width Water Outlets Size of Es.Overall Overall Length Line and Smoke Inches Inches Inches Inches Inlets Water Water Steam Inches 1400 1775 2150 2525 22x20 22 z 26% 22 x 32% 22 x 39'/$ 3.06 4.03 5.00 5.98 59 59 59 59 39'/. 39% 39% 39'/. 52. 52 52 52 35 27% 41 2-3 13 35 33% 41 2-3 13 35 39% 41 2-3 13 35 46% 41 2-3 13 2650 3475 4300 5125 5950 6775 28 x 24% 28 a 33*4 28x41*4 28x49% 28 x 58% 28x66% 4.826.45 8.07 9.70 11.32 12.96 70% Wt 70% W7Wti 70V) 45'/, 45% 45'/, 45% 45% 45'/, 62% 62% % 62% 62% 62% 41 41 41 4! 41 41 35% 43% 51% 60% 69 771/, 51 2-5 51 2-5 51 2-5 51 ' 2-5 51 2-5 51 2-5 16 16 16 16 16 16 5600 40 x 33% 9.20 80 59% 72% 55 43% 58 2-5 21 6925 40x41% 11.52 80 59% 72% 55 51% 58 2-5 21 6250 40 x 49% 13.85 80 59% 72V) 55 60% 58 2-5 21 9575 40 x 58% 16.18 80 59% 72% 55 69 58 2-5 21 10,900 40 x 66% 18.50 80 59% 72% 55 77% 56 2-5 21 12,200 40x75 20.82 80 ' 59% 72V) 55 85% 58 2-5 2! 13,525 40 x 83% 23.13 80 59% 72% 55 94 58 3-5 21 14,850 40x91% 25.50 80 59% 72% 55 101% 58 3-5 21 - 10,900 60x41% 17.29 m 86-/, 74% 82 51% 60 2-6 26 13,525 60 x 49% 20.78 8! V) 86*/, 741/, 82 60% 60 2-6 26 16.175 60 x 58% 24.27 81V) 86% 74% 82 69 60 2-6 26 >8.800 60 x 66% 27.76 81V) 86% 74% 82 77% 60 3-6 26 21,450 60 x 66% 31.25 81V) 86% 74% 82 85% 60 3-6 26 24,100 60 x 66% *34.74 81V) 86% 74% 82 94 60 3-6 26 26,725 . 60x75 29,375 60x75 *38.22 81V) *41.72 81V) 86% 86% 74% 74% 82 82 1n0o1%% 60 60 3-6 26 3-6 26 32,000 60x75 *45.20 81V) 86% 74% 82 >18% 60 3-6 26 34,650 60 x 83% *48.69 81V) 86% 74% 82 127% 60 3-6 26 37.300 60x83% *52.18 81V) 86% 74% 82 >35% 60 3-6 26 39,950 60 x 83% *55.67 81V) 86% 74% 82 . 143% 60 3-6 26 42,600 60x91% *59.16 8IV) 861/, 741/, 82 152% 60 3-6 26 45,200 60x9!% *62.65 81V) 86% 74% 82 160% 60 3-6 26 47,850 60x91% *66.14 81V) 86% 74>/, 82 168% 60 3-6 26 Ratings, as given, are derived from tests made in accordance with the American Society of Heating and Ventilating Engineers' Low-Pressure Boiler Testing Code. JGratc areas are for entire length of firebox, but, unless otherwise ordered, these boilers will be shipped with bridgewall section to reduce grate to length in table of dimensions above. 555