4 lapel (lapel). Closed-face Glasrock (#1505) cassette filter holders fitted with half inch extenders and probes developed by N10SH*S^ vere used for both the in-mask and lapel samples. The sample probes are specially designed to minimize the loss of particulates. The cassettes contained 0.8 urn, 25mm cellulose ester filters. The sample trains vere calibrated before and after taking each sample using a mass flow meter. The mass flow meter was calibrated against a bubble flow meter at the beginning and end of the study. A flow rate of 2 Lpm was used for in-mask samples. Lapel samples were taken at 0.5-1.0 Lpm to avoid overloading. Samples vere collected for a one to tvo hour period. Each sample represented a single vearing of the respirator. Fiber counts.vere done per NIOSH procedure PS-CAM 239 ^ ^ (phase contrast microscopy), except that the triacetin/acetone mounting method vas used as described in (7) NIOSH method 7400 . Counting vas done according to the "A" counting rules in method 7400. Five hundred fields vere counted for in-mask samples to increase analytical sensitivity. All analyses vere done by one counter who participates successfully in the American Industrial Hygiene Association`6 Proficiency Analytical Testing quality assurance program. Concentrations vere calculated from the actual number of fibers counted (even if fever than 50 fibers vere counted) per the formulas in the NIOSH method. DUP 0907358