The Fox Furnace Co.
,Air Conditioning Automatic Heating Systems
:am
AIR ONINO
Sunbeam Coal Fired Air Conditioning Unit (Cont'd)
Series No. 80 Users throughout the country attest to the long life and high efficiency of this Sunbeam Series. The riveted and welded heating element combined with efficient Sunbeam Filters make the Series No. 80 the cleanest system available. An inner casing prevents heat loss and keeps exterior cabinet cool.
Exterior Cabinet--Modern design gives attractive appearance. Die cut and formed parts connected by
snug fitting slip joints, and the use of 20 gauge steel provide rigid, air-tight construction. Finished in green crystalline baked enamel.
Heating Element--No. 7 gauge boiler plate, riveted and welded. Radiator made of No. 12 gauge boiler plate, welded.
Equipment--Blower, Motor, Filters, Humidifiers
No. SO. showing blower, motor, and filters.
and Controls same as in Series No. 20. Stoker Fired and Oil Fired Models--The Series
No. 80 is available in specially designed stoker and oil fired models. See table for capacities.
Series No. 5500
This new Unit supplies the demand for an air conditioner
with a steel heating element--at a low price. .It measures up to the high Sunbeam standards in performance, dura bility and attractive appearance.
Exterior Cabinet--Modern design gives attractive appearance. Die cut and formed parts connected by snug
fitting slip joints and the use of 20 gauge steel, provide rigid, air-tight construction. Finished in green crystalline baked enamel.
Heating Element--No. 8 gauge boiler plate steel riveted
and welded. Radiator made of No. 12 gauge steel, welded. Equipment--Blower, Motor, Filters, Humidifiers and
Controls same as in Series No. 20.
Interior of Series No. 6500 showing blower, motor and
filters.
Capacities--Blower-Motor-Filter Specifications--Series Nos. 20, 80 and 5500 See next page for Dimensions.
Blower No. Diam. of Blower Wheel Pitch Oia. of Blower Pulley Number Blowers Motor Hp , Motor Rpm Number Filters
Btu Capacity at Coal Hand Fired Oil or Stoker Fired
Register
No.
JApprox.
tApprox.
tCfm Blower jam Blower
Coal Oil Fired Required Rpm Required Rpm
Hand or Stoker at 65 F at// at 65 F at'//
Fired Fired S.P. S.P.
4420 95.000 108,000 1020 401
1158 430 1-12 12* 12'
Va 1725 4(20* x 20*)
4820 II 1.000 126,000 1195 5220 133.000 150,000 1426
430 459
1356 1618
459 487
1-12 12* 12' 1-12 12* 12'
|
Vi 1725 4(20* x 20*) Vi 1725 4(20* x 20*)
5620 153,000 173,000 1644 487 1865 516 1-12 12* 12*
H 1725 4(20* x 20*)
Blower No. Diam. of Blower Wheel Pitch Diam. of Blower Pulley Motor Hp | Number Filters
Coal Hand Fired Coal Stoker Fired
Oil Cun Type Burner
Oil Rotary Burner
No. Btu Cap tCfm Btu Cap JCfiu Btu Cap tCfm Btu Cap tCfm acity at Required acity at Required acity at Required acity at Required Register at 65 F Register at 65 F Register at 65 F Register at 65 F
sb>o
o
z6
2280 103.000 1112 113,000 1210 117,000 1260 134,000 1441 1-12 12* 12' 1 Vi 4(20* x 20*)
248(1 118,000 1269 129.000 1381 134,000 1439 153,000 1645 1-12 12' 17' 1 Vi 4(20* x 20*)
278(J 155,000 1666 169,000 1814 176,000 1890 201,000 2160 1-15 15* 15* 1
4(20* x 20*)
3080 182,000 1962 199.000 2136 207,000 2225 237.000 2543 1-18 18* 15* 1 % 5(16* x 25*)
3480 222.000 2385 242,000 25% 252.000 2705 288,000 3091 1-21 21* 15* 1 V. 6(16* x 25*)
5520 76.000 815 83.000 888 86.000 924 98,000 1057 1-9 9i// 17* 5522 89,000 956 97,000 1041 101,000 1085 115.000 1240 1-12 17* 12* 5524 104,000 1114 113.000 1213 118,000 1264 134,000 1444 1-12 12* 12* 5527 132,000 1415 143,000 1541 149,000 1605 171.000 1835 M2 12* 12*
Vi 2(16* x 25*)
% 4(20* x 20*)
Vi 4(20* x 20*) 4(20* x 20*)
JAir heated from 65 to 165 F increases 19 per cent in volume. Therefore, warm air ducts should have capacity for 19 per cent greater Cfm than listed above.
Nos. 2280, 5520 and 5522 are not available in special Stoker-Fired Model.
896
The Fox Furnace Co. Air Conditioning, Automatic Heating Systems
Dimensions--Series No. 20
No.
Height
Overall Heating
Width
Compart ment
Height Blower Compart ment
Depth of Blower
Compart ment
Overall Depth
Air Discharge Opening
Air Intake Opening
Smoke Collar Diameter
Approximate Distance from Floor to Center of Smoke Collar
4420 44'/,' 4820 46'/,' 5220 52' 5620 56*
60* 60* 64* 64*
36%' 36%' 36%' 36%'
29%' 29%' 29%' 29%'
67%' 71%' 75%'
7W
20* x 20* 22* x 22* 23* * 23* 24'x 24'
14* x 36i/2* 14* x 361/2* 14* x 36// 14* x 36/2*
9* 9* 10* 10*
453// 453/4* 49'// 49%'
Allow clearance in rear equal to depth of blower compartment for removal of filters, blower and motor.
Dimensions--Series Nos. 80 and 5500
Height
No.
Overall Heating Width Compart
ment
2280 73%' 2480 75%' 2780 82%' 3080 91%' 3480 101%'
60* 60* 67* 67* 67*
Height Blower Compart ment
36%' 36%' 41* 41* 51%'
Width of Blower
Compart ment 29%' 29%' 33%' 36%' 42%'
Overall Depth
43%' 46%' 51%' 54%' 58%'
Air Discharge Opening
Air Intake Opening
20* x 20* 22* x 22* 25* x 25* 27'x 27* 32* x 32*-
14* x 36i/2* 14* x 36(4* 16* x 45* 20* x 51'// 24* x 55*
Smoke Collar Diameter
Approximate Distance from Floor to Center of Smoke Collar
9* 9* . 10* 10* 10*
41// 4P// 43y/ 44'/** 45%'
5520 65%' 5522 69%' 5524 73%' 5527 771%'
58* 58' 58* 61*
28%' 36%' 36%' 36%'
26%' 29%' 29%' 29%'
38%' 41* 43%' 48%'
18'x 18* 20* x 20* 22' x 22' 23* x 23'
10* x 281/2* 14* x 36'/2* 14* x 36'A* 14* x 361/4*
8* 8* 8* 9*
24V** 24V*' 24%' 24'
Smoke Pipe Tee extends out approximately 28 in. additional in Nos. 2280 and 2480, and 36 in. in
larger sizes.
.
Allow clearance at side equal to width of blower compartment for removal of filters, blower and motor.
Sunbeam Stoker Fired Air Conditioning Unit Series S The New Series "S" is designed for Stoker Firing exclusively. Either hopper or bin feed type stoker can be installed from front, rear, either side or below floor level through
openings provided by the factory. The large double radiator will accommodate several months to a full season's accumulation of fly ash without reducing the rated heating capacity of the Unit. Cleanout Collars are at front of radiator. Clinkers are con veniently accessible and can be dropped into clinker pan, located between clinker door
and fire pot, to cool. Heating element is constructed of No. 7 gauge boiler plate riveted and welded; radiator of No. 12 gauge steel, welded. Blower, motor, filters, humidi fiers and controls are the same as used with other Sunbeam Units.
Dimensions--Capacities--Blower-Motor-Filter Specifications--Series S
24-S 27-S
Distance From Center of Drum To Far Side of Blower Compartment...................
17i/2 150,000 4(20* x 20*) 61V* 9lg' 583/a*
34)6' 55* 26* x 26* 16'// x 44*/ 43'// 17* x 8'/2*
4*// 283//
2936' 29)6' 62%'
23'A 200.000 5(16* x 25*)
98%' 63%' 36>34' 56%'
203/s* X 5036* 44'/8*
17' x 81/2* 4*// 31' 313// 3136' 67%'
Combustion rate of stoker must conform to heating requirements of installation. Ratings based on coal having a calorific value of 12,000 Btu per pound.
LEFT: Interior view of Series S showing blower, motor ' and fillers. Bin Feed stoker is in-
stailed.
RIGHT: Heating element show ing Double Radiator; Cleanout Collars; Clinker Pan; Chutes; Chute Extension; Hopper stoker
installed from rear.