Document oeqOoJebgz62JV5nrk4EqMzo3
J
RROQRE99 REPORT
JiOE no.
report no.
^^^^MCCHNICAL^ERVICEj^EPTV-JLJLHjRUMEWCN^LAjf^^^J^^^LJT^^J^^^^^^
ibate
^f^JL^
W.O. KRUNMRlCN PLANT
BG.L. Bratsch JJR. Nettesheim a
#ED.W. Jackson . fl3
a
O P. E.'heisler'
fflB. W. Corlew to
D R. McCutchan `
*B H. J. Horner B D. J. Roth Its
J. Francis. '
m
a a " a
o
D R. Blowers '
B
O TO RECEIVE DETAIL SECTION
. 1B
*
.
OENERAL OPPICE
OTHER!
0 M. P. Lux g) D. Danna
(4)
Anniston i B3 J.C. Landwel
*D D.B. Hosmer/
Nitro
F. J. Holzapfel O W.R. Kellogt
R.E. Howard
S. 2nd St.
@ W.R. Richard P.0, DeGara*
J.R. Savage *OT.M. Patrick
Q *D J.F. Quinn
El Anniston *0 R.L. Wiese
#B G. L. Arnett #13
'
TITLBl
AROCLOR QUALITY
PERSONNELI W. A. Krull, C.
1st (W. C. Engman)
Regain pre-September, 1970, quality levels on Aroclor 1260 and 1242.
Pour consecutive lots of Aroclor 1260 from late September through early December, 1970, failed the after corrosion chloride test. No lots have failed specifications since Aroclor 1260 lot KM-1019 In early December.
All four stability measurements on Aroclor 1242 have Indicated a decrease in stability since October, 1970, as shown by cumulative sum charts.
To date, none of the actions or checks have linked a cause with the problem. Following is a list of actions and results to this point.
1. Raw Material Checks
.
a. Ferric chloride was out of spec, but not to a degree which should cause a problem.
b. Lime was checked against Anniston lime and found
to be normal grade.
o>
. CD
c. Biphenyl checks were made and no abnormal material c5
was found as compared to reserve samples from May. i>
a
d. Bromine and organics in chlorine have been checked.
, Although impurities are present, no stability
relationship has been found.
2. Laboratory distillation of Individual plant chlorinator
COMPANY CONFIDENTIAL INFORMATION
This doouMat to thr property of MooiiNo Ccpoay uf too leelptoto to reapoartblo for Ito oaftkoeplrm oaf diopooMtoa. ft orattoo eeat
ttol toforaotloa of Mooooato Coavoop okkhOMt aotbe roproduood, toooolod to. naoattwrlaod porooao or orat cutoUto Ort eoapoay orl
pr*por oatbortootioa. Eithor rototo to ooouro Etoo or destroy.
'
Poan woi^r^wrUTA^
STLCOPCB4066833
91570:4286(1)
2 February 10, 1971
SUMMARY (continued)
batches showed all chlorinators bad.
5. Laboratory chlorinations were Inconclusive. Our method failed to duplicate plant results in parallel runs.
4. Laboratory redistillation of previously analyzed bad material
produced specification grade Aroclor 1260. Only one trial
was made,
*
5. Cross checks between Anniston and WGK control labs have shown variations in stability analysis between the labs on eight samples.
6. A designed experiment was prepared for improving Aroclor 1260 stability but not run as normal conditions produced good Aroclor.
Future Work
1. Continue to monitor all stabilities of all electrical grade
Aroclors for trends.
^
2. If Aroclor 1260 does not meet specs, on the next run, instigate cross checks with Anniston, run the designed experiment, and redistill bad material in the plant.
5. Continue to improve the data bank relative to raw materials, especially chlorine and biphenyl. .
4. Continue cross checking with the Anniston Lab.
5. Determine a method for checking the efficiency of the chlorine demisters.
/br
Technical Services Dept
DSW 296921
STLCOPCB4066834
91570:4286(1)
-5-
February 10, 1971
I. BACKGROUND
A. Aroclor 1260 Stabilities (Data in Appendix A)
1. After Corrosion Chlorides
In September, 1970, ot KM-1016 of Aroclor 1260 failed the after corrosion chloride (A. C. Cl) test. Lots KM-1017, 1018 and 1019 subsequently failed A. C. Cl. Of these lots, only KM-1016 showed A. C. Cl drastically above the specifications (0.22 vs 0.05 max.). The other three lots showed A. C. Cl close to the specification (0.06, 0.09). Some intermediate sampling of these lots showed scattered values from normal (in specifica tion) to very high. Resampling and reanalysis was done with no significant change in results.
2. Monsanto Stability
Monsanto stability failed on Lot KM-1016 only, although it was bordering failure at 0.6l to 0.67 (spec. 0.7 max.) on the other three lots.
5. Hydrolysis Stability
Aroclor 1260 hydrolysis stability showed no significant variance from normal.
4. Rechecking Reserve Samples
A recheck of reserved samples from KM-1008, 1009, 1010, 1011 and 1015 for A. C. Cl. was done and resulted in good checks of OF 1008, 1009 and 1010 but failures on 1011 and 1015. All of these lots were analyzed as good material during the period May through August, 1970. A recheck of Monsanto stability of Lot KM-1015 showed it was ok.
B. Aroclor 1254
Electrical Grade 1254 showed no significant change in any of the stability measurements made (Monsanto, Thermal Chemical Chlorides, Westinghouse and Hydrolysis).
C. Aroclor 1242
Aroclor 1242 showed a decrease in stability, but it appears to have occurred closer to early October or about a week later than the 1260 problem. All four of the stability measurements have shown a decrease in stability of Aroclor 1242 although none have failed specifications.
DSW 296922
STLCOPCB4066835
91570:4286(1)
-4-
February 10, 1971
BACKGROUND (Continued)
D. Cumulative Sum Charts (Appendix B)
Cumulative sum charts of the stabilities of Aroclors 1242, 1254 and 1260 are attached as Appendix B.
II. WORK DONE AND RESULTS
A. Lab Distillation of Plant Batches (Appendix C)
Samples of each plant chlorinator were lab distilled and all five chlorinators showed poor A. C. Cl and good Monsanto stabilities.
B. KTA Session
A KTA session was held to analyze the problem. Raw materials, sample handling and analysis or plant operations were possible
problem areas. More information on all of these areas was required since no single^solution was evident. In order to isolate a raw material problem, lab chlorinations were planned. Further checking of plant and laboratory operation changes was also planned.
C. Lab Chlorinations (Appendix D)
Details of the lab chlorinations can be found in WGK AR&D
Report No. 1771 dated November 19, 1970. Of the trials the most significant were the last two which were run parallel to plant batches and then samples were distilled in the lab. Neither of these runs corresponded to the plant batches indicating our methods were not able to duplicate plant operation.
D. Raw Materials (Appendix E)
.
1. Biphenyl
A check on biphenyl showed that the biphenyl being used in November was not different than biphenyl used during May when good 1260 was produced.
2. Lime
Lime was checked against Anniston lime and found to be of equal quality. Purchasing confirmed that no change in lime source had occurred.
DSW 296923
STLCOPCB4066836
91570:4286(1)
-5-
February 10, 1971
WORK DONE AND RESULTS (Continued)
3. Ferric Chloride (Catalyst)
Although a sample of the catalyst failed to meet some of the specifications, it was not thought to be sig nificantly poor to cause the problem.
4. Chlorine
a. Bromine content is the only variable analyzed regularly that is considered to affect stability. This data showed no change in bromine content.
b. Organic content in chlorine is being checked by AR&D. This method has shown carbon tetrachloride and trichloroethane in the chlorine at Dept. 246. WGK AR&D Report Ho. 1821 dated January 18, 1971* describes the method and preliminary results.
c. Crosschecks with other chlorine using departments revealed low assays in chlorophenol production. This problem was .noticed around the first of October and seems to coincide.
d. The chlorine demjsters in Dept. 246 have been trapping a milky'"substance. In May, 1970, a similar material was caught. This material was identified as sulfuric acid with some carbon tetrachloride
,, present. During this period, 1242 TCC's increased and batch reactions were killed. The organic layer recently contained an unknown with a boiling point of about 300 C.
e. Point Comfort chlorine was identified as the source - of the acid/organics. (See memo by Dave Hobelmann
dated July 15* 170). An attempt was made to correlate the frequency of'-Point Comfort car unloading with the 1260 problem. No relationships seemed to exist between the source of chlorine and Dept. 246 usage.
f. A header change made in the Chlorine Department at the end of 1970 will provide Dept. 246 with a larger percentage of Point Comfort chlorine.
E. Redistillation
A laboratory redistillation of a sample of Aroclor 1260 with high A. C. Cl resulted In material which passed the test.
F. Plant Operations
The department was combed for changes in equipment .operations.
DSW 296924
STLCOPCB4066837
91370:4286(1)
-6-
February 10, 1971
WORK DONE AND RESULTS (Continued)
The only change found that could be connected to stability was a lowering of the biphenyl feed storage temperature (115 to 95 C,) for safety reasons. This in turn lowered the starting chlorination temperature from about 125 C. to about 110 C." Research reports and the SMP recommend starting chlorination at no lower than 125 C.
G. Designed Experiment
Since the starting chlorinator temperature was suspect, a designed experiment was drawn up to include it and two other variables, each at two levels.
Variable
Normal or Low Level
High Level
Starting Biphenyl Temp.
. 110 C.
1250 c.
Chlorination Temp.
150 C.
190 C.
Catalyst Level
2 #/Batch
4 #/Batch
These variables are the ones which have been shown to affect the stability of Aroclor 1242 in past research. When this test was started with all variables at the normal level, good Aroclor 1260 was produced. Since no inventory was on hand, production made the decision to complete r run at normal levels to insure ales could be met. No Aroclor 1260 has been produced since this run.
H. Control Lab Crosschecks (Appendix F)
Samples have been exchanged between the WGK and Anniston control labs. Both laboratories show occasional high values for the stability tests. There seems to be a lack of con sistency in the data whether on good or bad material.
III. CONCLUSIONS
A. The stabilities of AroclQrs 1260 and 1242 have apparently decreased (worsened) on the most recently produced lots as shown by the cumulative sum charts. No lots have failed tests since Aroclor 1260 Lot KM-1019.
B. Laboratory chlorinator batches were of little use in pinning down causes while troubleshooting. It was impossible to duplicate the plant chlorinator with our method.
DSW 296925
STLCOPCB4066838
91370:4286(1)
-7-
February 10, 1971
CONCLUSIONS (Continued
C. No definite raw material can be blamed for the upset. Although no conclusive data was found, the wide variances in the quality of finished goods in a single run seem to indicate chlorine as the most suspect of the raw materials,
D. Although it was done only once, redistillatjon improved the stability of Aroclor 1260,
E. To this point, data received from lab crosschecks has shown inconsistencies.
IV, RECOMMENDATIONS
A. TSD continues to monitor finished goods stability to catch any differences that may be correlated to the chlorine header change or any other change,
B. If further 1260 problems are encountered with after corrosion chlorides:
1. Make crosschecks with the Anniston lab,
2. Try redistillation in the plant,
3. Complete the designed experiment,
C. More data be obtained during production mans. Bromine, . sulfuric acid and organics In chlorine and methyl biphenyl and low boilers in biphenyl are examples. This will give something to compare to if upsets occur and help pinpoint causes.
D. Continued crosschecking between the control labs Is needed and should be carried out to determine normal variability between labs. Samples should be handled as similar as pos sible beforeanalysis to reduce sample variability.
E. TSD Investigate ways to check the efficiency of the chlorine demisters.
/br
W. tf. Krull Technical Services Dept
DSVJ 29M20
STLCOPCB4066839
91570:4286(1)
-8-
February 10, 1971
APPENDIX A
Date
5/18 5/50 5/5 5/8 5/15 5/17 6/5 6/21 7/10
Lot
1005 1004 1005 1006 1007 1008 1009 1010 1011
1970 AR0CL0R 1260 LOT SAMPLES
-
Monsanto
Stability (Spec. 0.7 Max)
1st Analysis Reanalysis.
(PPm)
(Date)
(Spec. 0.05 Max)
After Corrosion
___________ Chlorides
1st Analysis Reanalysis
(ppm)
(Date)
0.43
0.51 0.54 0.46
0.45 0.25
0.51 0.43 0.40
0.46 (5/14)
0.02 0.03 0.02 0.02
0.02 0.02 0.03 0.05
0.14 (5/14)
8/9 9/10 9/22
1015 1015 1016
0.52 4.9
-
2.3 (9/23) 3.6 (9/24)
0.02 0.35 0.22
0.05 (8/11)
0.68 (9/25) 0.57 (9/24)
10/2
1017
10/8
1018
12/9 12/25
1020 1021
0.61
0.67 0.63 0.51
0.67 (10/4) 0.59 (12/14)
0.06
0.09 0.08 0.04
0.06 (10/4) 0.06 (10/5)
0.05 (12/14)
OS'N ^
STLCOPCB4066840
91570: /l&GCLOK J&42
-9CoMVL&TtV
. February iu, y(
SvtA CftfiXT
APPENDIX B
BOO
*^TGt t~(TV
s<
****
>H^
^oo
\
so
too
. .......... .. f|yg.^^4y^fS
__
10*,t,*^*t*****4H*r
- too EROfefr SLOO
O'
?r- $frA8tt.n*y
***`
y1 >-
iod
o
rae
*\
DSW 296928
x'V W 'fVsV '|:tVmVm 'V '5' o-'' N ' D 13"'
LCS /*.
* j*v **
71
STLCOPCB4066841
91570:4286(1)
/}g&C.6lZ
4
trigs
/ :.
Boo
............. ...
' 1 .. 1
'..j
( 'STA&tUYy
v' -ZOO ...... -
-10-
February 10, 1971
C>VteQU)TlOZ SotA..C^JZT ....
APPENDIX B (Cont'd)
&GQ
T C
~&@Q
;
ttii/y v/gs?#A*<s/*wsr
D 's<^>Jt*ST8 0/4 /ry
-E?<9# :
.
.
/00 Hvb.V5/$
SV ns
-100 (
I
DSW 296929
STLCOPCB4066842
91570:4286(1) /~)r e> c uo& /26 0
S'T'rtEfLt 7~>6 s
$0
/jpT&H
... ;
/
(' Cto&eswt*
Ch
- 11 -
February 10., 1971
CoMVt.nTn>Z Som
V
APPENDIX B (Cont'd)
^ BSO
.
O ***-^H.vw**' *
- -ggQ $T8WUYy
Li /*A
I
DS\N 296930
STLCOPCB4066843
91570:4286(1)
12 February 10, 1971
APPENDIX C
AR&D Distillation of ll60 (Part of Lot KM-1018)
Chlorinator No. Porocel Treatment Mons. Stab. A. Ci Cl A. C. Acid A. C. Color T. C. Chlorides
#1 No .04 .19 .001 20
#1 Yes .04 .10 .001 15 ---
#2
No .06 .10 .001 15 --
0o0
00 .
#5 No
.14 .001 25 0.84
H _#4
#5
Yes
No
No
.49 .24 .06
.05 .14
.002 .001 .001
20 0.75
10 ...
15 . _--
DSW 296931
STLCOPCB4066844
91370:4286(1)
- 13 APPENDIX D
February 10, 1971
LABORATORY CHLORINATIONS
Date
Method _
-
Week of 1. Aroclor 1260 in lab from
10/26
plant Biy> and cylinder Clg
2. Aroclor 1260 from purchased Bi<|) and cylinder Clg
3. Aroclor 1260 in field from plant crude Aroclor 1154, plant Cl2
11/2
1. Aroclor 1260 from plant raw materials
This plant rim parallel to plant batch #421. Lab distillation of #421. crude produced i;hese
results - 0.35 '
11/4
1. Lab size batch parallel to plant batch #428 with plant materials, then lab dis tilled both plant and lab.
Lab size
Plant #428
A. C, Cl 0.03 0.04 0.04 0.06
0.11 0.01
Mons. Stab.
0.89
0.27 0.49
0S\N 296932
STLCOPCB4066845
91370:4286(1)
- 14 APPENDIX E BIPHENYL ANALYSIS
February 10, 1971
Sampling Date
8/6/70 8/13/70
9/1 9/2
9/3
Car No. NATX 21258 NATX 21265 GATX 94514 NATX 21249. NATX 21265
2,4 Methy1Biphenyl
740 ppm
1260
670
710
700
Low Boilers
380 ppm 290 260 400 300
Est. Use Date
-
-
9/3, 9/4 9/3, 9/4 9/5, 9/6, 9/7
Samples of biphenyl representing AM-160, or May production. was compared to car NATX-21249 dated 11/2/70 by GC and found to have no significant differences.
os*196911
STLCOPCB4066846
91370:^26#' (1)
- 15 APPENDIX E (Cont'd)
February 10, 1971
FERRIC CHLORIDE ANALYSIS
Assay
Sulfates
Ferrous Salts
Solubility: Water Alcohol
Epee. 97.0#, Min. 0.05$, Max. Trace, Max.
Complete to SI. Turbid, Max.
Actual 98.9$ 0.20J6 7 Trace
7SI. Turbid
29^
dsnN
STLCOPCB4066847
91570:4286(1)
Date
1-19-70 1-26 1-25 1-21 1-28 2-2 2-5 2-7 2-8
2-9 2-17 2-18 2-21 2-22 2-22 2-25 2-24
2-25 2-25 2-27 2-27 2-28 2-28
5-5 5-6
5-7 5-11 5-18 4-1 4-8 4-22 4-29 5-7 5-15 7-28 9-4 9-50 10-6
11-5 11-12 11-16 11-25 12-2
Bromine (ppm)'
42 246 452 220
90 81 162 222 190 66 98 54 592 262
515 571 480 146 480 210 494
589 599 400 516 552 252
25 66
250 298 294
177 10
212 90
246 40 76
280 187 247 282
- 16 -
February 10, 1971
APPENDIX E (Cont'd)
BROMINE IN CHLORINE -
Carbon
Date
Tetrachloride
' (PPm) From 246 Vaporizer
,
12/14/70
57
Trichloroethan (ppm)
25
12/21/70
40
55
1/11/71
175
15
From Nash Pumps
1/12/71
5
14
o**1
STLCOPCB4066848
V
91370:4286(1)
- 17 APPENDIX F
February 10, 1971
AR0CL0R 1260 CONTROL LAB COMPARISON
Sampled
KM-1019 12/3A0
Test
A. C. Cl Hydrolysis Monsanto
Spec..
Typical
0.05 Max. None 0.7 Max.
,0.03 0.20 0.40
Anniston (Rerun)
0.02
0.71 0.58
WGK (Rerun)
0.24
0.45
0.80
KM-1019 Finished Product Tank 12/3/70 KM-1020
KM-1021 12/14/70
Am-7 KM-401?
AM-705
AM-137
A. C. Cl Monsanto
0.05 Max. 0.7 Max.
0.03 0.40
0.17 0.15
0.04 0.64
A. C. Cl Free Cl Monsanto
0.05 Max. 0.05 Max 0.7 Max.
0.03 0.01 0.40
0.07 0.07 0.37
0.03 0.59
A. C. Cl Free Cl Hydrolysis
Monsanto
0.05 Max 0.05 Max. None
0.7 Max.
0.03 0.01 0.20
0.40
0.018
0.018
0.46 (0.53)
0.39
0.04 0.09 (0.10 0.51
A. C. Cl"
0.05 Max.
0.03
0.04
0.01
Hydrolysis
None
0.20
0.28
Aroclor 1242 Control Lab Comparison
Monsanto
0.4
0.10
0.03
0.25 0.15
Hydrolysis TCC Monsanto Hydrolysis TCC
0.5 0.65 0.4 0.5 0.65
0.07 0.15 0.10 0.07 0.15
0.28
0.19 0.05 0.07 0.15
0.07
to
i 0.10 (0.14
<J>
% 0.03
0.07
0.26 (0.28
TCC
0.65
0.15
0.16
0.21 (0.22
(0.14)
STLCOPCB4066849