Document oea1a1Z56K6w0ng4Rp5bDaRy8
1
I'upci!?
2.1^3 \-r?ys construction department
' AIR SURVEY L. V. Thfc-cher ar.d A. L. Linch
0iJ October 21, 1966
Problem:
To determine:
A. Whether or not the total air-borne asbestos dust count generated during the fabrication and installation of asbestos containing insulating materials exceeds, either at the source or in the breathing zone, the Threshold
Limit Valve of 5 million particles per cubic foot
(m.p.p.c.f.) established by the American Conference of
Governmental Industrial Hygienists (ACOIH).
f.'Sir: --** *
.-*
'4
B. Extent of air-borne asbestos contamination of the general shops area, surrounding grounds, and installation sites.
C. Total dust count for use in the evaluation of over-all atmospheric dust loading and for detection of other potential dust problems.
Note:
Item C will involve little additional cost as the differential counting of the sample is
nominal compared to the cost incurred in
procuring the sample particularly where special set-ups of work, tools, and materials are involved.
Procedure: I. Collection
Two methods will be used for the initial 'survey:
A. Station sampling - portable.
'Tht' "Unico Constant Rate Uni-Jet" "Freon - 12" powered
sampler equipped with the improved standard midget impinger
("Unico 2000"; followed by an 0.8 micron, pore size
millipore filter (Cat. No. MAH0033D) will be used. The
dust collected in "dust-free" distilled water in the
\ impinger will be counted at the University of Pittsburgh
Graduate School of Public Health by the method approved
by the Asbestos Textile Institute. The dust collected on
the bacffc-up filter will be counted also at the University
" of Pittsburgh. This filter will collect the particles
iu .he size range be*ovi 3 microns which is mot retained
05C
in the first stage es well es larger pertlculete which might
carry over from the impinger. The limit of resolution in
counting is-1.3 microns.
-
0Ci2!o 00P 0900626
SC-DP-01460
Page 2
Tne "tJni-Jet" sampler will be preset to aspirate air samples &t the recocimended standard rate of 0.1 cfm, and the sample volur.e calculated from the aspirating time (usually 1 cu. ft.). The seapllng assembly is readily portable and can be located close to operating tools, machines, and manual operations.
B. _ Personnel.
The light-weight, compact battery operated "Unico Model 440
Mighty-Mite Air Sampler1' has been selected for this phase
of the survey. A water-filled "Micro Impinger" bached
by the "Millipore" filter will be employed to collect
the dust samples. This sampler assembly will be carried
at all times by the man selected during his work assign
ment and will collect a continuous sample from his breathing
zone. Samples collected by both methods simultaneously
will reveal the amount of air-borne particulate at the
tool and at the point of inhalation. These results will
demonstrate whether the material does, in fact, get
inhaled and the efficiency of the ventilating system In
reducing the dust count.
,
II. Sample Counting.
Samples will be sent by Air Mail--Special Delivery to insure delivery to the analyst within 24 hours as speci fied by the Asbestos Textile Institute. The counting, sizing, and calculation of results will be carried out according to the Asbestos Textile Institute's procedure under the direction of Mr. Raymond J. Manella, Instructor.in Occupa
tional Health, of'the uHiversi'ty of"Pittsburgh^
A differential count; that is, asbestos and total dust will be - made on each impinger sample but only a total dust count will be taken from the filter as, by definition, fibers will not be present at this stage. This increases the cost to some extent, but only In this Banner can a reliable conclusion be drawn in conformance with the criteria presented in the "Problem."
Equipment acquired.
ITEM
' A) "Unico Automatic Uni-Jet Air Sampler" (Constant Rate)
B) "Mi'ghtty Mite Air Sampler"
ORDER NO. Have on hand
Ordered
PRICE Borrowed
($124.50)
C) "Freon"(Registered) Gas Propellant
LO-PAC-7533
L0-FAC-7u36
( 47.30)
nrws . - *
DUP 0900627
r<i 3
I D) Extra Midget Ir.pingers
LO-PAC-7955 LO-PAC-7533
< 75-20)
E) Hygrometer P) Killipora Filters
LO-PAC-7872 LO-PAC-7871
( 16.00) ( 20.00)
0) Two-Range Temperature _
Thermometers
"
LO-PAC-7952
( 72.00)
H) Micro-Impingers
. ( 15.75)
TO DATE TOTAL PURCHASED
C$230.50)
Other similar cost items may be required as the program progresses.
Interpretation of Results.
A. L. Linch of the Chambers Works Industrial Hygiene Laboratory will interpret the results. After the accumulation of approximately 50 counts, the problem will be evaluated and redefined if necessary. A preliminary report will be prepared and recommendations for continua tion cr termination of the study presented. With allowance for blanks, the 50 counts will permit collection of approximately twelve samples.
%
Scope.
.
This survey, to be effective, must encompass all facets of the work performed in the shops and in the field. Some, at least token sampling of sites other than Chambers Works should be Included for control purposes. The possibility
that this program may be required on a routine basis indefinitely whenever end wherever asbestoe containing
materials are encountered must be considered. Certain restrictive, regulatory actions by Governmental agencies
. can be expected as a result cf the publicity attached to
' the implication of asbestos in respiratory illness. The burden of proof of compliance with Threshold Limit Values will rest on the user.
Preliminary Results. \
The initial dust counts have indicated a very low air-borr.s
dust burden in the fabricating shop. This result was somewhat"surprising and will require extensive confirmation.
A conference held with Mr. Corn end R. J. Hsnella at the
University of Pittsburgh on October 17* 19<S6 developed the
following conclusions: c
DUP 0900628
or
Page 4
1. Our sampling technique is acceptable but must be . considered to represent the minimum required; that is, use of the baching filter should be continued and used whenever asbestos dust samples ere collected. This precaution is necessary for our protection as health studies to date have not
. established vrnich site range is responsible for pathological effects.
2. Semples should be collected with ventilation facilities sr.ut dcwn to determine what the potential dust burden could be if no protection was furnished. These results would provide an estimate of ventilation efficiency and maximum dust generation levels.
3. The personnel sampling program (Part B of ProcedureZ Collection) is sound and would provide the first information of this type available on actual individual exposure levels during an entire work assignment. Both Mr. Corn and Mr. Mahella expressed Interest in a collabrative effort on this phase.
SPECIAL KOIC:
1. At least three counts vlll fee made for each sampls to dIfferentiete between total count and asbestos, and then* the after filter stust be counted.
2. At this time ve estlrcte we'll heve to sample about 150 cstcrial`fabricating combination functions.
3. Each of these samples will get three counts costing $10 per
count. Total cost Is tha projected to approximately 54,500
spread over the entire sampling period which will likely be 18 months.
\
C
Dup 0900629