INTEROFFICE / LAKE CHARLES
TO FROM
Mark Wood .
Max. Hekmat
April 12, 1990 1990 Monitoring Strategy
In reference to the 1990 Industrial Hygiene Monitoring Strategy, a few items need to be revised.
1. The Monitoring Strategy for Vinyl Chloride specified that in the event that any sample taken shows exposure levels in excess of the action level, a second, follow-up sample will be collected within 6 months from receipt of the analysis. Based on OSHA Standard 29 CFR 1910.1017.d.2.ii, any vinyl chloride results above the action level must be re-monitored every 3 months.
2. The Monitoring Strategy requires 122 STEL samples for chlorine. This number should also include TWA exposures ( 25%). This can be a combination of sampling and calculation, but compliance with the 0.5 PPM TWA, OSHA PEL must be addressed.
3. There has been some modification on the progress report time table. Satisfactory progress will be considered 25% by 4/1, 60% by 7/1, 80% by 10/1 and completed by 12/1.
In order to make the Laboratory's Progress Report more pleasant, I have enclosed two separate Progress Report Forms designed recently for organic and inorganic sampling. Please use these forms to report your progress.
MH/fq
Enclosure
cc: Ron Williams Jim Barter - G.O. 36W1 (w/o enclosure)
Loren Anderson - G.O. 36W1 (w/o enclosure) S
Clyde Dennis Bob McCorquodale (w/o enclosure)
SL 0^3060
c (%i' 'lit
/vip/P**1 Company:
Analytical Laboratory
34 PENN CIRCLE WEST PITTSBURGH, PA. 15206
Wayne Hebert
PPG Industries P.O.Box 1000 Lake Charles, La.
(412)363-6600 70602
Assay: Hexavalent Chromium (Cr+^) Analytical Method: NI0SH 7600 Limit of Detection: 0.3 yg
Received: 5/1/90 Reported: 5/14/90
IHF No.
Sample I.D.
Cr+6 M9
5006-90 5007-90 5008-90
1 2 3
0.3 0.6 0.6
5009-90
Blank
<0.3
A"alJ,st:
f<
Accredited by: AIHA Accepted by: EPA
L'-V'U-
David R. Fussaro, Ph.D. Laboratory Supervisor
Licensed by: CDC and Pa. Dept, of Health
SL 043061
Uor? ^
Analytical Laboratory
C&mpany:
34 PENN CIRCLE WEST PITTSBURGH, PA, 15206
Wayne Hebert PPG Industries P.0. Box 1000 Lake-Charles, La.
(412) 363-6600 70602
J-aktikdh.
Assay: Free Silica
Received: 5/30/90
Analytical Method: NI0SH 7500
Reported: 7/2/90
Limit of Detection: 0.02 mg Quartz; 0.01 mg Cristobalite
IHF No.
Sample I.D.
6232-90 6233-90 6234-90 6235-90
2 Blank
7 Blank
Dust Wt. mg
0.07 --
0.52
__
Quartz mg
<0.02 <0.02
0.251 <0.02
Cristobal ite mg
<0.01 <0.01 <0.01 <0.01
Dust weights are provided by PPG Industries.
JUL20
Analystifs^-^f^
Accredited by: AIHA Accepted by: EPA
David R. Fussaro, Ph.D. Laboratory Supervisor
Licensed by: CDC and Pa. Dept, of Health
0A362 S^*