58:___________________ } CHAPTER 3 ________. 1946 Guide from which: W% = 0.002847,- hi -- 17.820. At the temperature of the resulting mixture, ' therefore, Aa + 0.002847 Wit's = 17.820 At 61 F the Iefthand member of this equation has the value 17.750; at 62 F its. value is. 17.991; by interpolation the temperature of the resulting mixture is 61.29 F where the humidity ratio at saturation, also by interpolation, is 0.01161; hence the'degree of saturation of the resulting mixture is (1 = 0.002847 -r 0.01161 = 24.52 per cent . On the MolHer Diagram, Fig. 5, a straight line is drawn between point 1 (0 F, 80 per cent) and point 2 (70 F, 20 per cent); then point 3 is located on the line one-eighth of the distance from point 2 to point 1. The temperature and degree of saturation at point 3 are read directly. Adiabatic Mixing with Injected Water Another typical air conditioning.process is that of injecting water into . an air stream to mix with it adiabatically.. Let W2 -- Wi, denote the increase in humidity ratio of the air; this is obviously the quantity of water injected per pound of dry air; it follows that the quantity of energy injected per pound of dry air is (W2 -- Wi)hy,, where h,, denotes the specific enthalpy of the water as injected; if the process is adiabatic this produces an equal increase in the enthalpy of the air, namely, hi -- hu therefore, . fe - hi = h,,(W, - W,) (10) according to which: the process of injecting water into an air stream to mix adiabatically with it is represented by a straight line on the Moilier Chart whose direction is fixed by the specific enthalpy of the water as injected. ' The protractor drawn, on the. Mollier Diagram provided with this book ' provides a'convenient means for determining this direction. Example 9. It is desired to increase the humidity ratio of air at 70 F dry-bulb, without changing its temperature. Under what conditions may water be injected in. order to accomplish the desired result: .' Solution. .At 70 F the increase of enthalpy'per unit increase of humidity rations. : Aas/Hs = 17.27 -r- 0.01582 = 1092 Btu per pound of water. This must be the specific - enthalpy of the water added if the state point of the air is to be moyed along the 70 F' isotherm. Saturated steam at 668 F has this specific enthalpy (see Keenan-Keyes, Thermodynamic Properties of Steam). ' On the Mollier Diagram, Fig. 6, it is seen that the 70 F isotherm is parallel to the line on the protractor for a specific enthalpy of 1092 Btu per pound. Adiabatic Saturation Any process by which the state point of moist air is moved to the saturation curve adiabatically may properly be called adiabatic satu ration. ... Example 10. Liquid water chilled to 35 F is evaporated into an air stream initially at 90 F and 50 per cent saturation. How much water must be evaporated to bring the air ,. to saturation at what temperature. , Solution. The initial enthalpy of the air is 21.625 + 0.50 X 34.31 = 38.780 Btu/lba; the initial humidity ratio is 0.50 X 0.03118 = 0.01559 lbw/lba; the specific enthalpy of the chilled water is 3.06 Btu/lbw; therefore, the temperature at which the air reaches ' the saturation curve must be such that the enthalpy As and humidity ratio Ws at satu ration satisfy the equation, As. - (Ws - 0.01559) X 3.06 = 38.780 The solution is.75.19 F where the humidity, ratio at'satnration is 0.01894; consequently, Fig. 5. Illustration of Use of Mollier Diagram in Solution of Example 8 Fig. 6. Illustration of Use of Mollier Diagram in Solution of Example 9