Document oe89V2KK80JqJ8K1e1ZGyeXb3
PLAINTIFF'S EXHIBIT 1G-199S
GENERAL OFFICES
500 West Adam; Street, CHICAGO, ILL.
SALES OFFICES
Atlanta. On.. 1510 Cnmlhr 131.1".
Lev- An^cle*. Calif.. 507 Architect' Bide.. 5th St. at Ficneroa
Baltimore, Mil., 402 Kt-v-.fr BUI".
Memphis, Trim., Bank nt Commerce BUlir.
Buffalo, ,\. V,, r,36 Ellicott Sipiare Bills.
Charlcstmvn. Mass. (Boston Other], Mystic Wharf
Milwaukee. WB.. Oregon ami (trove Sts. Minneapolis. Minn., 2510 Fosltav Tower
Cincinnati, Ohio, 1009 Atlas Bank Bltlj;.
\ew "5 nrk City. X. .. 220 E. 42ml St.
Cleveland. Ohio. 1514 Builders' Exchange Bid".
Omaha. Xeh,, 925 Woodmen of the World Bids.
Dallas, Tex., 1510 Santa Fe Bids.
Philadelphia, Pa.. 1 500 Walnut St.
Denver. Colo., Continental Oil Bids. Detroit. Mich., 1527 Majestic Bids-
Pittshursh. Pa.. 1604 I.aw and Finance Bids.
St. Louis, Mo., Continental Life Bid".
Indianapolis, I ml., 41 7 Architects' Bids.
San Francisco. Calif.. 40S Second St.
Kansas Cite, Mo.. 505-6-7 Fairfax BUI".
Washinstnn, D. C.. 604 Lenox BUI".. 16th and L St., X. W.
Toronto. Ont.. Canada. 159 Bay St.
MILLS, MIXES, QUARRIES AND WAREHOUSES--See Map
1. Alabaster. Mich. 2. Amanda Park, Calif. 3. Arden. Nev. 4. Blue Rapids. Kan. 5. Boston, Mass. 6. Bronx, New York Citv 7. Buffalo, X. Y. 8. Chicago. III. 9. Cleveland. Ohio
10. Cordova, III. 11. Detroit. Mich. 12. East Chicago, Tnd.
13. Falls Village. Conn. 14. Eldorado. Okla. 15. Farnams, Mass. 16. Fort Dodge. Iowa
17. Genoa, Ohio IS. Great Barrington. Ma: 19. Grand Rapids Mich. 20. Gypsum, Ohio 21. Harrison. N. J. nn Heath, Mont.
25. Hillsboro, N. B. 24. Hollywood, Calif.
25. Jeannette, Pa. 2fy. Lancaster. Ohio 27. Laramie. Wyn. 28. Los Angele*. Calif. 29. Loveland, Coin.
50. Midland. Calif. 31. Milwaukee. Wis. 32. New Brighron, S. I.,
N. Y. 33. North Kansas Citv, Mo. 54. Oakfield. N. Y. 55. Oakland. Calif.
36. Philadelphia, Pa. 37. Piedmont, S- D. 3S. Plasterco, Va. 39. Portland. Ore. 40. Sacramento, Calif.
41. San Francisco, Calif. 42. Seattle, Wa*h. 43. Southard. Okla. 44. Sweetwater, Tex. 45. Warren. Ohio 46. Wentworth. N. S. 47. Windsor, N. S.
INDEX
Experience............................................................................................. I Manufacturing and DistributingFacilities................................ 1 Sale'* and Service Facilities............................................................ I Complete Diversified Line of Products...................................... 1 The Trade Mark--Your Guarantee.......................................... 1 Gypsum---General Technical Data
Gypsum ......................................................................................... I Fireproof ....................................................................................... 1 Standard X Plastering System Description ................................................................................... Preliminary Specification Requirements........................... -
Specifications................................................................................ 3 Details ........................................................................................... + Standard X Suspended Ceilings Description .................................................................................. 5 Specifications................................................................................ 5 Details ........................................................................................... '> Red Tup Rockluth Description .................................................................................. Red Top .Metal Lath and Accessories
Descriptions.................................................................................. ^ Illustrations.................................................................................. 9 Youngstown Pressed Steel Metal Lath
Descriptions ..................................................................................hi Illustrations................................................................................... Id North Western Expanded Metal I-arh Descriptions ................................................................................ Ii* Illustrations ................................................................................... I"
pacp
Gypsum Hardvvall Plasters
General Features...................................................
n
Advantages and Descriptions................................................ 11
Cement Plasters (Complete Data).............................................. 12
Wood Fiber Plasters (Complete Data)....................................12
Prepared Plasters (Complete Data).....................................12, 15
Knndcrete ( Complete Data )............................................................15
Red Top Trowel Finish Complete Data).................................15
Prepared Gypsum Finishes (Complete Data)........................15
Oriental Interior Colored Finish Piaster
(Complete Data) ................................................................ 13. 14-
Finishing Lime (Complete Data)..................................................14
Masons Lime (Complete Data).....................................................14
Gauging Plasters (Complete Data).............................................. 14
Red Top Keene's Cement(Complete Data).......................14, 15
Aridize Moulding Plaster (Complete Data)............................ 15
Red Top Patching Plaster (Complete Data)............................ 15
Master Specifications--Interior Lathing and
Plastering.......................................................... U,, 17. IS, lr), 20
Oriental Exterior Stucco (Finish and Base Coat)
Dt-cription ....................................................................................21
Specifications ........................................................................ 21, 22
Sheetrock--The Fireproof Wallbourd
Description ........................................................ ,,....................... 22 Specification* (Short Form;...................... I ........................2'
Sheetrock Reinforced Joint S\`-terns ( Description )........... 22
Sheetrock Tile Board ..................................................................... 25
(jvplap--Fireproof Sheathing (Description; ........................ 25
PRODUCTS DESCRIBED IN OTHER CATALOGUES See Sweet*' Manurncturers' Index for:
(1) Econo Expanded Metal. (2) Sheetrock--P\refill; Marks T System of Root Construc
tion; Reinforced Root Tile; Monolithic Floor* and Roof*; P\rohnr Partition and Furring Tile; Pvrohar Beam and Column Fireproofing.
f5) Chromite Sheer Metal Wall Tile. ;4) Insulation Product*. ' 5) Architectural Acoustic*. XnRe Abatement and Sound
Control.
'<'>) U. S. G. Paint Product*.
i
3 *3 2
nw
B2445
UNITED STATES GYPSUM COMPANY GENERAL COMMODITIES
Wall Plasters, Plaster Finishes, Lime, Exterior Stucco, Metal Lath, Gypsum Lath, Gypsum Wallboard and Sheathing Board
Experience
U.S Sales and Service Facilities
The United States Gypsum Company is a pioneer in the gypsum industry in America. For more than twenty-eight years, the com pany--through its laboratories, experimental de
6
The twenty-two sales offices in the important building centers guarantee adequate service to archi tects.
Complete Diversified Line of Products
partments and field investigations--has closely TRADE-MARK
Wherever gypsum is adapted to building uses
studied the requirements of the building industry.
there is a U.S.G. product specially designed to fulfill
Its formulae and mechanical equipment have been pains the particular requirement.
takingly designed to adapt each of its gypsum and other
The broad scope of the company's gypsum and other
products to meet comprehensively these requirements. products is indicated by the Products Index.
Manufacturing and Distributing Facilities
The superiority of U.S.G. products is based upon high grade raw material, perfected processes of manufacture and one control from mining to shipping.
The forty-seven mines, milles and warehouses, strategically
. located throughout the United States, assure exceptional national distribution facilities and a product specially manufactured to - fulfill variable local climatic conditions. The map below shows the location of the forty-seven U.S.G. centers and visualizes these important service facilities. In Canada, these commodities are sold exclusively by the Canadian Gypsum Company, Ltd.
The Trade-mark
Products bearing the trade-mark of the United States Gypsum Company are safeguarded against imperfections.' They are rigidly inspected by experts at every stage of production, from the selection of the raw materials to the shipment of the
finished products. Any variation from the highest U.S.G. Standard means
rejection. This rigid maintenance of quality over a long period of
years has established the name and trade-mark of the United States Gypsum Company as synonymous with the highest standard of excellence in building materials.
B3006 1092
GYPSUM--GENERAL TECHNICAL DATA
Cacn^PSum--Chemically, Gypsum is hydrous calcium sulphate "f '50-2H,0. It is a widelt distributed mineral' found in rock - ^troation. The rock gypsum is crushed, ground and then P'cined, which drives off a part of the molecular water, form-
a *}em`_hydrate or plaster of paris. This product, when - ixed with water, recrys allizes or sets.
Fireproof--The sui erior qualities of gypsum as a firenu* buildinS material have been definitely established by T-erous tests made by the Underwriters' Laboratories, Inc.,
"e Bureau of Standards. Columbia University, and by the
bureau of buildings in many of the larger cities. (Authentic test data furnished oh request)
The temperature on the unexposed side of the gyjwum slab cannot exceed 212 F. while there is any water of crystallization in the gypsum. This is due to the fact that the water of crystalli ation in the gypsum must be vaporized during the application of fire to it, and as !' gypsum slowly calcines, the cellular structure fills with steam. It is this barrier of calcined material which stubbornly resists the progress of the fire.
PAGE I
Continued on next page
, d ;ttj
STANDARD X PLASTERING SYSTEM
(Trouble-free Plastering)
Introductory
Through its twenty-eight years' experience in the manufacture and sale of lathing and plastering mate rials. the United States Gypsum Company has had forcibly impressed upon it the fact that unsatisfactory plaster work is usually the result of thinness ("skimp ing") of plaster coats, oversanding of plaster, or both. Exhaustive investigation has disclosed that these diffi culties are eliminated with the Standard X Plastering System.
As a result, the United States Gypsum Company has purchased the patents, good will and the sole privi lege of manufacturing and marketing the Standard X Plastering System. The purchase was made only after an investigation of some hundreds of buildings in which Standard X had been used, after consultation with archi tects, plastering contractors and building owners, and after extensive laboratory tests. _ The Standard X System has been extensively used It in Detroit and other cities for more than five years. It has been used in residences ranging in cost from $10,000 to SI.000.000, in apartment buildings and in business buildings. Owners, architects and plastering contractors have, without modification, declared it to be the solution of the plastering problem where trouble-free wall and ceiling finishes are sought.
Passed the One-hour Fire Test
; This system has successfully withstood the Standard Onc^nour Fire Test in accordance with specifications of the Amcr-
Society for Testing Materials, conducted at Columbia yCnk-ersity, New York City, on June 20 and July 18. 1929.
cPy ot' the signed abstract covering this test report will be rtomished on request.
Requirements of Satisfactory Plastering
satisfactory plastering job obviously is one that provides satjstactory plastering service, and that minimizes ordinary : and ceiling finish defects. A satisfactory plastering job is r-tothposed of five factors--good construction, lath, plaster, work-'
ant^ an adequately controlled system of installation. First, good construction eliminates many plastering defects nt to settlement, shrinkage, etc. V. Second, to provide maximum service, the lath used should U Pr'Proof, verminproof, non-deteriorating and should provide ught bond with plaster. Third, an ideal plaster must possess structural strength ,__Tcslst ordinary abuses to which it may be subjected. It must *??**eSs aPpreciable fire resistance, and it must permit of ease -reparation and application.
-fourth factor required to produce a satisfactory plas !S. workmanship--necessary precautions of erection hcation; precautions against adulteration; and full for plaster.
With the single exception of "good construction," all the factors just mentioned, including a "controlled system of in stallation.'' the Standard X Plastering System adequately pro vides, as exemplified in the ioliowing six paragraphs.
Standard X System--Description
General--The Standard X Plastering System is formed of Standard X Lath, Standard X Metal Fabric, Standard X base Coat and United States Gypsum Company Finish Plaster. It provides all the necessary requisites for a satis factory plastering job--lath, quality of plaster, assured thickness of plaster, and adequate joint reinforcing. It further provides more fire protection and more insulation than does the ordinary lath and plaster wall or ceiling.
Standard X Lath--Standard X Lath is a special gypsum lath % in. thick, lo in. wide and 48 in. long, finished on the back with a moisture-resisting fiber of a distinctive red color. It is shipped in bundles (a patented feature) to prevent injury. Standard X Lath is nailed and fitted with the ease of wood. It is fireproof, verminproof and non-deteriorating. Plaster, according to authoritative tests, bonds more tightly to it than to any other type of lath. In short, all the qualities necessary for a satisfactory lath are found in Standard X Lath.
Standard X Metal Fabric--Standard X Metal Fabrics, applied over all joints and corner angles after Standard X Lath has been erected, are composed of snips of expanded galvanized metal 3 in. wide, and made with a patented selvage edge. The fabrics are easily applied. They assure adequate thickness of base coat, a very important factor.
Standard X Base Coat--Standard X Base Coat is a gyp sum plaster scientifically compounded for use as part of the .Standard X Plastering System. It is entirely factory-mixed. Xothing is added to Standard X Base Coat, before application, but water. This base coat plaster is exceptionally plastic. It bonds tightly with Standard X Lath, and over the Standard X Metal Fabric, to form a hard, dense, unit plaster con struction that will be more resistive to cracking than other plasters.
Standard X Base Coat is much more resistive to fire than an equal thickness of ordinary sand-mixed plaster. It also has greater tensile ami compressive strength, ami provides a much more durable wall ami ceiling finish. Authentic test data will be furnished on application.
Installation--To assure maximum good workmanship where the Standard X Plastering System is installed, installa tion is by licensed plastering contractors only. In each locality the United States Gvsum Company issues licenses for the erection of the Standard X Plastering System to reliable con tractors, who bind themselves to install the Standard X System according to complete specifications. Further, the Standard X Plastering System is sold only by dealers to whom licenses are issued because of known reliability.
Moderate Cost
Although Standard X Plastering System is a unique prod uct and each of the component parts is of the highest quality, i; is not expensive. Its cost is such that it is adaptable to the small home as well as the most pretentious building.
8B006 1093
PRELIMINARY SPECIFICATION PROVISIONS
'Note: The following provisions should he mode in the proper specification divisions to assure the best installation T0f Standard X Plastering System.
(I) Carpentry Work
(la) Furring--All masonry surfaces shall be furred.
^(lb) Framework--All studding, joists and furring shall he X, .m^> kvel and true, and where possible, spaced accurately - *m. or 16-in. centers. <lc> Bracing--Place horizontal 2x4-in. bracing on line with
Vu a,1 a" openings for doors and arches and at headers *JIs for all window openings. Bracing shall extend from
the stud to which headers and sills are attached to the next stud, driven tight and securely nailed.
(ld) Backing--Where backing plates are necessary in framework provide 2x4-in. studding instead of the usual %-in. boards.
(le) Grounds--All grounds shall he standard % in. thick (lace of stud to face of finished plaster).
(2) Electrical Construction
(2a) Outlet Boxes--All outlet boxes, etc., shall be accu rately set with faces Is in. in front of the studding an 1 joist line (flush with face of Standard X Plaster when applied).
PAGE 2
Continued on next page
Lmicc Stii.Cc; Gvpsun: Compun^
Standard X Lath and Standard X Metals in Place Ready for Standard X Base Coat Plaster Note method of reinforcing all openings, fabric never lapped
NOTE: Stretch all fabrics tightly
THE STANDARD X FABRICS HAT RUN WITH JOISTS AND STUDS SHOULD BE NAILED ON LAST. USE TWO E'FINISHING NAILS TO EACH IE" STRIP.
FIRST APPLY STANDARD X ANGLE FABRICS, IN ALL IN TERNAL ANGLES. USING FOUR NAILS TO EACH AB" STRIP.
USE FOUR E* FINISHING TiailS TO EACH jc-stoip in FASTS'INC- STAN'DAFO X FABRICS THAT Run ACROSS JOISTS
FABRiesP" D NT LAP
USE STANDARD X EXPANDED CORNER BEAD ON EXTERNAL ANGLES, FULL LENGTH. ALLOW SUFFICIENT SPACE
for corner bead when
applying strips.
Sketch Showing Correct Application of Standard X Lath and Standard X Metals (Do not Up fabrics)
DETAILS--STANDARD X PLASTERING SYSTEM
PAGE 4
05 o c U'
o
United States Gypsum Company
B2449
STANDARD X SUSPENDED CEILINGS
Detcription
Standard X Suspended Ceiling System is a patented system ladling and plastering It is sold :>y licensed dealers and erected by licensed contractors and must be installed according to the manufacturer's specifications and directions.
Standard X Suspended Ceiling System provides a strong, rigid and economical ceiling construction for any type of build ing requiring a suspended or attached ceiling.
Standard X Suspended Ceilings are hung in the manner regularly employed for supporting suspended ceilings, following standard lathing practice.
SPECIFICATIONS
* Note: Notes are explanatory or advisory only and should not be included in the specifications
(1) Work Included
' The following ceilings shall be furred, lathed and plastered with Standard X Suspended Ceiling construction. Note: List and locate here all toork covered by this con tract and after each item note the finish, tohether "trotocl," sand float," "Oriental interior floated or textured."
(2) Materials
(2a) Hangers-- (2al) Minimum size lor attaching main channels to sup ports-- hi in. round steel or lxrk in. fint steel--spaced not to exceed 4 ft. in each direction. (2a2) Minimum size for attaching :>i-in. runner channels direct to supports--Xo. 8 galvanized wire--spaced not to exceed 2 ft. 6 in. in each direction. (2b) Tie Wire--Minimum size No. 16 gauge galvanized annealed wire. (2c) Main Channels--Minimum size He in.--minimum weight 442 lbs. per 1000 lin. ft.--maximum spacing not to ex ceed 4 ft. center to center. (2d) Runner Channels--Minimum size 94 in.--minimum weight 276 lbs. per 1000 lin. ft.--maximum spacing 2 ft. 6 in. center to center. (2e) Lath Channels--%-in. Standard X Lath Channels-- minimum weight 113 lbs. per 1000 lin. ft.--spacing per pair 16 in. on centers. (2) Lath--16x48x%-in. Standard X Lath--weight approx imately I860 lbs. per 1000 sq. ft. (2g) Metal Fabrics--2x2x48-in. Standard X Angle Fab rics. 3x48-in. Standard X Flat Fabrics. (2h) Thumb Tacks--Special large size Standard X Thumb Tacks.
(3) Erecting Channels
(3a) Standard main channel hanger spacing not to exceed 1 ft. on center in both directions, properly install 14-in. pencil rod or lxA-in. steel hangers to support lVi-in. main channels. Level and fasten main channel to hangers, and anchor channel ends at walls in an approved manner. Tie 94-in. runner chan nels, spaced not to exceed 2 ft. 6 in. apart, to main channels.
Note: Use above clause token the type of construction re quires main channels. (3b) Concrete joist and floor arches shall have hangers spaced not to exceed 2 ft. 6 in. on center throughout the length f joists or arches. Level and fasten runner channels to hangers, and anchor channel ends at walls in an approved manner. , (3c) (Concrete slabs) (holloso tile floor slabs) shall have nangers spaced not to exceed 2 ft. 6 in. on centers in both direcmms. Level and fasten runner channels to hangers, and anchor -cnannel ends at walls in an approved manner. (3d) Under bar joist construction, wire 94-in. runner chan
nels, spaced 2 ft. 6 in. apart, to lower chords of joists. Level and fasten runner channels to hangers, and anchor channel ends at walls in an approved manner.
Note: In the types of construction included in (3b), (3c) and (3d), :li-in. runner channels may be fastened directly to hangers loithout the use of main channels.
(4) Erecting Lath
After (main channels and) 94-in. channels are in place, erection of Standard X Lath Channels and Standard X Lath shall be started.
Clip in position at right angles to runner channels and tight against the wall, across the full width of room, one pair of %-in. Standard X Lath Channels, back to back. Use No. 2 Standard X Clips for attaching lath channels to runner channels.
Note: Sec top vieto, page 6.
Then place in position a row of Standard X Lath with trade mark up. Insert one edge' of the lath into the 9s-in. channels and support the opposite edge temporarily with No. 3 Standard X Clips, fastened to the 94-in. runner channels.
Note: Sec detail at start, page 6.
Next place another pair of Standard X Lath Channels, back to back, in position across the full width of room. Place one channel securely over the No. 3 Clips and 48-in. lath edges, and support both channels with No. 2 Clips.
Note: See top vieto, page 6.
Erect successive rows of Standard X Lath and Standard X Channels as above.
Break joints at ends of lath. Fill in any small places next to the wall with metal lath strips, securely fastened and completely covering adjacent lath channel joints.
Note: See detail at finish, page 6.
( 5 ) Reinforcing
Apply Standard X Metal Fabrics in all angles and over all joints, butting ends to form continuous reinforcing. Do not lap mds of fabrics. Fasten fabrics to Standard X Lath with special large size Standard X Thumb Tacks, approximately 12 ir apart, staggered.
irst apply Standard X Angle Fabrics in all ceiling angles, nailing one edge to wall and fastening the other edge securely to the lath.
The flat fabrics have a natural curvature. To obtain best lathing and plastering results, apply the fabrics with bow out.
Next apply Standard X Flat Fabrics over all continuous lath channel joints and then coyer the remaining lath joints with 12-in. lengths of Standard X Lath Fabric, securely fasten ing fabrics to lath with Standard X Thumb Tacks.
Note: See bottom vieto, page 6.
(6) Plastering
Note: Specify plastering as aiven in paragraph (6), page 3 for Standard X Plastering System.
ESTIMATED QUANTITIES OF MATERIAL REQUIRED FOR 100 SQUARE YARDS '
(Baaed on )2-in. total thickness of plaster and solid yardage measurements of ceilings, before erection of partitions)
One square foot of completed ceiling, including y2 in. plaster, weighs approximately S pounds
I H-in. Main Channels 4*ft. spacing
250 lin. ft. = f **'* 3 Standard X Clips
r 6-in. channel spacing
-- 250 pieces
3*-t8-in. Standard X Flat Fabric
___ 825 lin. ft.
A*-in. Runner Channels 2 ft. 6-in. spacing 400 lin. ft.
Standard X Lath 900 sq. ft.
Standard X Thumb Tacks 1500
%-in. Standard X Lath Channels
1400 lin. ft.
No. 2 Standard X Clips for 2 ft. 6-in. channel spacing
310 pieces
2x2x4S-in. Standard X .-inple Fabric Depends on partition layout
Standard X Base Coat 20-22 1004b. bags
Finish Coat
PAGE 5
continues on next pac
BB006 1095
n*rr c
0601 90090
United States Gypsum Company
B2451
RED TOP ROCKLATH
Description
to Rocklath than to any other type of lath. The uniform,
Red Top Rocklath is a solid sheet of gypsur.i encased
dense structure of Rocklath effectively eliminates plaster
n a tough fibrous covering, forming a uniform, strong, fireresisting plaster base, It is made n convenient, practical-size units. The fibrous covering iffords uniform suction, insur es a permanent, strong bond tvith gypsum plaster. Red Top Rocklath is easily nailed to wood studding, furring or joists.
Red Top Rocklath has the L'.S.G. patented reinforced folded edge which gives maxi mum strength. With the new rounded edge profile, the edge is not subject to injury and the boards are easy to han dle.
Sizes, Weights, Etc.
Applying and Plastering Red Top Rocklath
discoloration.
Economy in Erection-- Compared with ordinary lath, Red Top Rocklath requires only one-eighth the handling ami one-third less nailing for equal areas. Bundles are stacked and carried and the light weight units handled and erected quicker and with greater ease --there are no splinters. It scores and cuts cleanly and easily without waste. May be applied vertically in closets, corners or on pilasters.
Uniform Thickness -- Since no plaster is lost through droppings pushed through the lath and the ragged keying plaster behind the back oi the
Red Top Rocklath boards arc made Vs in. thick and in two sizes--16 in. x 32 in. and 16 in. x 48 in. The boards arc packed in bundles for easy handling and stacking--6 sheets to the bun-
lath is conserved, the thickness is uniform throughout. The job may be said to be both plastered and back plas
tered in one operation.
! die. Each bundle of 32-in. boards contain 21 % sq. ft. and weighs t about 40 Ihs.; each bundle of 48-in. boards contains 32 sq. ft.
and weighs about 60 lbs. Each 32-in. unit
Eliminates Moisture--Red Top Rocklath needs no wet ting before plaster is applied. The continuous dry gypsum
sheet, % in. thick, eliminates its propor
weighs 61/: lbs., the 4S-in. size, 10 lbs.
tionate part of the usual wet plaster mois
j _ Either size provides the usual vertical
ture and at the same time seals off the
j joint break (similar to that of wood lath)
applied plaster moisture from contact with
without cutting.
the, absorptive wood framing, preventing
much of the usual swelling and subsequent
i Advantages
Fireproof--Does not burn or readily
shrinkage. Due to there being less moisture
present, the plaster and building are dry
transmit heat. It interposes a continuous
and ready for the application of interior
fireproof sheet of substantial thickness over
wood trim and decorating in the minimum
the wood-frame construction, thus tending
time.
i to confine the fire to the room in which it originates.
Enduring--Does not disintegrate or corrode.
Soundproof--Gypsum is a poor con ductor of sound. As compared with wood lath and plaster, tests show that Red Top Rocklath and plaster walls arc su
No Expansion or Contraction--Does j not expand, warp or buckle when wet
perior in effectively resisting sound trans mission.
' Plater is applied; con.-uquently will not 7 shrink when plaster dries out.
Comparative Cost--The completed wall (Red Top Rocklath and plaster) costs
An Ideal Plaster Base--The strong
less than metal lath and plaster, and about
; fiber covering with its uniform suction pre
the same as wood lath and plaster.
vents the plaster from "slipping" when
applied. Gypsum plaster is easily applied ( 5Lnd the bond is strong and permanent, j Tests show that plaster bonds more firmly
Rocklath Does Not Burn
vpluces combustible material between walls; prevents waste ot plaster
Specifications
See Master Specifications, page 16.
88006 1097
| Home of Architect S. L. Adler, Mobile, Ala. T>;. Rocklath used, also Red Top Plaster and Oriental Interior Colored Plaster Finish
PAGE 7
Bundled Rocklath C onmun u oil next puge
12452
United States Gypsum Company
RED TOP METAL LATH AND ACCESSORIES
iuctory llThat the United States Gypsum Company may furnish
Icsatcrials required for lathing and plastering, thus making able to the distributor and the contractor the economy and ntage of mixed car shipments and to the architect centralresponsibility, the company has placed upon the market the
ppjete Red Top Line of Metal Lath and Accessory Products. Red Top Metal Lath products are distributed nationally,
pies furnished on request
Top Diamond Mesh Lath ^ Materials--
Open hearth steel, painted black. . Galvanized.
Copper bearing steel, painted black. Armco ingot iron, painted black. Weights--22, 2.5, 3.0, 3.4 lbs. per sq. yd. Self-furring (corrugated)--All above materials and ghts furnished in crimped or corrugated self-furring type. Sheet Size--24x96 in. packed 9 sheets (16 sq. yds.) per die.
Red Top Comerite and Strips (Diamond Mesh-
Special Selvage Edge)
Materials--Open lu-ar.h steel, painted black,
Weight--2.2 lb. per sq. yd. basis. Comerite, 140 lbs. per
M ft. Strips, 75 lbs. per M tt.
Size--Corncrite 3x5x<'
strips 3x96 in. each; packed
504 ft. per bundle.
Red Top Cold Rolled Channels
Material--Open hearth steel.
Stock Lengths--14. lo. IS. -<> "
Sizes and Weights--
,.
, ,.
a: in__776 lbs per KXHt lin. tt.; pneked 20 pieces to bundle.
1 in.--332 lbs. per 1000 lin. II-: l,:icked 10 Pieces t0 bundle-
iy, inn..--_415566 llbbss.. ppeerr H..XH>.....l.i.n... ft-: Packed 10 Pieces to
bundle. 2 in.--552 lbs. per 1000 lin. It-
packed 10 pieces to bundle.
Special large llange (Cnbro) 270 lbs. per 1000 lin. ft.;
packed 20 pieces lo bundle. jVore: Sold only in JU.
h""dl,'t
Top Vs -in- Flat Rib Lath Materials--
Open hearth steel, painted black. Copper bearing steel, painted black. Armco ingot iron, painted black. Galvanized in 3.6 lb. weight only. . Weights--2.75, 3.0, 3.4, 4.0 lbs. per sq. yd. Galvanized only (3.6 lbs. per sq. yd. . Sheet Size--24x96 in., packed 9 sheets (16 sq. yds.) per (idle.
TP %-in. Rib Lath Materials--
Open hearth steel, painted black. Copper bearing steel, painted black. Armco ingot iron, painted black. Galvanized in 3.6 lb. weight only.
Weights--2.75, 3.0, 3.4, 4.0 lbs. per sq. yd. Galvanized only
3.6 lbs. per sq. yd. Sheet Size--24x96 in., packed 9 sheets (16 sq. vds.) per
* ndle.
Red Top Comer Beads
Material--Gahanized.
Types and Weights-- No. 1A--26 gauge KspauMnn
. lype; we.ght 230 lbs. per
1000 lin. ft.
, ...
. ,, ~,n ..
No. 2A--26 gauge Scalloped lype; we.ght 220 lbs. per
1000No.' 4A--26 gauge Standard Type; weight 200 lbs. per
1000 lin. ft.
.. . , .,
No. 5A--28 gauge Tt-in. radius Hullnose; we.ght 24a lbs.
per 1000 lin. ft. No. 9A--Clips for btilhmsc bead. No. 10A-26 gauge 14-in. rad.us b.xpanston Type Bullnose;
weight 375 lbs. per 1000 lin- r`Packed--Crated, approximately 500 or 1000 hn. ft. per
crate, sold only in full crate;..
Red Top Base Screeds
Materials--Galvanized................ - - . - -
.........
No.P3A--26^mgeh.tSxpai'siou Hush; weight 230 lbs. per 1000
Im' No. 6A-26 gauge plain; weight 140 lbs per 1000 lin. ft
pd Top % -in. Rib Lath Materials-- Open hearth steel, painted black. Copper bearing steel, painted black. Armco ingot iron, painted black. Weights--.46, .56, .74 lb. per sq. ft. Note: '14-in. Rib Lath sold by square foot. All other lath
types sold by square yard. Sheet Size--24 in. wide by 4 to 12-ft (inclusive) lengths, i sheets to the bundle.
*d Top Sheetlath
Materials--Open hearth steel, painted black and galvar
I frights--4.5 lbs. (painted black) and 6.18 lbs. (galva-
| red) per sq. yd. Sheet Size--24x96 in., packed 9 sheets (16 sq. vds.) per
indie.
t
t ed Top Expanded Metal--1^4-in. Mesh for Stucco
Materials--Open hearth steel, painted black.
Weights--1.8, 3.6 lbs. per sq. yd.
Sheet Size--1.8 lbs., 48x96 in., 3.6 lbs., 51x96 in., packed
sheets to bundle.
Furring Nails--850 to box; weight 8.5 lbs. per box.
No. 7A__26 gauge curved ...... .. ; we.ght 19a lbs. per 1000 1,n' Packed-Crated. a,.pros imafly 500 or 1000 lin. ft. per crate, sold only in full crates.
Red Top Picture Mould
Material--26 gauge, galvanized. Weight-220 lbs. per 1<"*> l"1- ft' Packed-Crated. approximately 500 or 1000 lm. ft. per
crate, sold only in full crates.
Red Top Expansion Casings
Materials--Galvanized.
Types and Weights--
,
.
No 4-26 gauge, quarter round; we.ght 350 lbs. per 1000
Im' No 6-26 gauge, O. C.; weight 350 lbs. per 1000 lin. ft
No. 9-24 gauge, special quarter round, 43a lbs. per 1000
lin. ft
..
Clips--Patent casing locking clips.
Miters-Onc-pieco s.atnp-d rasing m.ters for Nos. 4.
6 and 9.
Master Specifications
For use of Red Top M-.al Lah and Accessories see Master
Specifications. p:ig<- 16
WEET'S
PAGE 8
Continued on next pmje
BB006 1098
United States Gypsum Company
B2453
660T 900U6
United States Gypsum Company
'OUNGSTOWN PRESSED STEEL METAL LATH DIVISION OF UNITED STATES GYPSUM COMPANY
action
_nprccedcnted service on metal lath products is assured I g'rrsult of the acquisition hy this company of the metal lath
jjjon of the Youngstown Pressed Steel Company. U.S.G. , maintain on thee products its usual ethical policy, and the [-of both metal lath and plaster being supplied by one stable manufacturer suggests a unified responsibility of nile advantage to every user.
PS %-in. Rib Lath
Materials-- Open hearth steel, painted black. Copper bearing steel, painted black. Weights--2.5, 3.0, 3.4, 4.0 lbs. per sq. yd. Sheet Size--24x96 in., packed 9 sheets (16 sq. yds.) per undle.
'PS Mahoning Diamond Lath
Materials-- Open hearth steel, painted black. Galvanized.
Copper bearing steel, painted black.
Weights--22, 2.5, 3.0, 3.4 lbs. per sq. yd.
Corrugated--All above materials and weights finished in Corrugated (self-lurriug) on order.
Sheet Size--24x96 in., packed 9 sheets (16 sq. yds.) per bundle.
YPS Z-Rib Lath
Materials--
Open hearth steel, painted black. Copper bearing steel, painted black. Galvanized (3.4 lb. weight only).
Weights--2.75, 3.0, 3.4 lbs. per sq. yd.
Sheet Size--24x96 in., packed 9 sheets (16 sq. yds.) per bundle.
YPS Smooth Edge Cornerite
Material--Open hearth steel, painted black. Weight--2.2 lb. Diamond Mesh. Sizes--Flange widths, 2, 3 and 4 in. Length, 8 ft. 50 pieces per bundle.
Packed
NORTH WESTERN EXPANDED METAL DIVISION OF UNITED STATES GYPSUM COMPANY
itroduction
p The acquisition also of the North Western Expanded Meial Company has made the U.S.G. line of Metal Lath ^Products complete, has further augmented manufacturing facilifties, and has brought in new technical experience which, work ing in conjunction with the U.S.G. and "YPS" engineers, assures manufacturing standards of the highest order. Every
toty and town in the country is now served by complete stocks metal lath products close at hand.
|Kno-bum, Jr. (Small Diamond Mesh Lath'S
Materials--
Open hearth steel, painted black. Galvanized. -Copper bearing steel, painted black. Pure iron, painted black.
- Weights--22, 2.5, 3.0, 3.4 lbs. per sq. yd. Corrugated--All above materials and weights furnished
corrugated (self-furring) on order.
--ar- Sheet Size--24x96 in., packed 9 sheets (16 sq. yds.) per
ndle.
Saver (Vs-in. Rib Lath)
, Materials--
1^7 ?Pen hearth steel, painted black.
Copper bearing steel, painted black,
height--3.4 lbs. per sq. yd.
ndjk*6*
*n-> Pac'<e<' 9 sheets (16 sq. yds.) per
Norwest Flat Rib Lath
Materials--
Open hearth steel, painted black. Copper bearing steel, painted black.
Weights--2.75, 3.0, 3.4 lbs. per sq. yd.
Sheet Size--24x96 in., packed 9 sheets bundle.
(16 sq.
yds.)
per
%-in. Longspan Rib Lath
Materials-- Open hearth steel, painted black. Copper bearing steel, painted black. Weights--3.0, 3.4, 4.0 lbs. per sq. yd.
Sheet Size--24x96 in., packed 9 sheets (16 sq. yds.) per bundle.
% -in. Longspan Rib Lath
Material--Open hearth steel, painted black. Weights--.50, .60, .75 lb. per sq. ft. Sheet Sizes--2 ft. wide x 4, 5, 6, 7, 8, 9, 10, 11, 12 ft. long.
Steelhart Stucco Base
Material--Copper bearing steel, painted black. Weights--1.8, 3.6 lbs. per sq. yd. Sheet Sizes--1.8 lb., 48x96 in. (32 yds. per bundle) ; J.6 lb., 51x96 in. (34 yds. per bundle).
BB006 1100
Kno-Bum Jr.
rhwEcr'i
Steelhart Stucco Base
YPS Z-Rib Lath
PAGE 10
Continued on next poyc
United States Gypsum Company
B2455
GYPSUM WALL PLASTERS
General Features
Description--Gypsum Plasters are made l>y driv ing off water of crystallization from gypsum rock through calcination, or heat treatment. The addi tion of water to this basic product (calcined gypsum rock) forms a plastic mass which unites with the same amount of water as was driven off during calcination. When this plaster is mixed with water it re-crystallizes or sets. The plaster resists fire and is extremely hard and strong.
All U.S.G. Plaster meets the standard specification for Gypsum Plaster of the American Society for Testing Ma terials.
Identification--Red Top Bag
In addition to the U.S.G. trade-mark on each bag of plaster, the United States Gypsum Company's Plasters are contained in the standard Red Top bag, which provides a positive means of identification that discourages substitution.
The red top is assurance that the material in the hag has been made and tested according to most rigid specifications.
Quick Set--Fast Drying--Gypsum Plaster sets up uniformly hard and homogeneous within two to six hours after application. Inside of thirty-six hours, under proper drying conditions, the plaster dries and there is no further dampness or sweating.
It is due to these prime characteristics that Gypsum Plasters have acquired almost exclusive preference and use.
Plaster Package
General--Every package of U.S.G. Gypsum Plaster bears the familiar trade-mark (see page 1), and bags have the Red Top. Each bag bears the brand and the mixing direc tions.
Multi-wall Paper Bag--The "multi-wall" bag, made of multiple layers of strong kraft paper with air spaces between, is the standard "paper" bag of the United States Gypsum Company.
'u_ Advantages
Adaptability--Gypsum Plaster adheres satisfac- torily to gypsum, wood or metal lath; gypsum or clay tile; brick or other approved plastering surface.
Fire Retarding--Made of gypsum, it is a valuable fire-resistant.
Exceptional Adhesiveness--Its exceptional ad__yhesiveness adds strength which greatly increases struc|=rtural durability.
Does Not Expand or Contract--It does not ex:pand and tear itself loose from the surface to which it is applied, even when subjected to fire. It will not crack of itself, shrink or stain.
Durable--Gypsum Plaster will withstand the wear yand tear of occupancy during the life of the building. =its hard, dense body affords a substantial foundation J0T the finish coat and applied decoration.
, . Saves Time--It sets in two to six hours and [Ones within 36 hours--interior trim and finish may
US' reasonab1}' soon, follow the plastering without ^danger from moisture.
Plasticity, Richness and "Slip"--U.S.G. Plas ters have been developed as much for the convenence of the plasterer as for perfection in the above
Because of its strength the bag can be dropped from as high as one can reach without danger of breakage. The multi-wall gives adequate protection--the several layers of paper keep the plaster dry in the warehouse, and a sudden shower while the material is in transit or unprotected at the job will do little if any damage. It is light in weight, easily handled and stored. The dealer and contractor have no investment tied up in bags which are to be returned for credit; nor do they lose the value of sacks stolen from the job or damaged.
In view of these advantages we recommend the multi-wall bag as the most satisfactory plaster package both from an economic as well as a practical viewpoint. Multi-wall paper bags are of SO-lb. and 100-lb. capacity.
Jute Sacks--When plaster is ordered in jute sacks, these are sold with the plaster and credited when returned in good condition, freight prepaid, to the mill from which the plaster shipment was made. Return of sacks must be made in accord ance with our standard shipping directions and our customary terms.
Cloth or jute sacks are of 100-Ib. capacity.
Brands
The standardization nationally of U.S.G. plasters under the "Red Top" brand is a protection to the architect and a con venience to the trade.
The architect is assured that the quality of the plaster, from whatever mill shipped, will be identical.
When specifying "Red Top" for use in a distant city, the architect is assured (1) that the plaster will be the same as that witli which he is familiar; (2) that a shipping mill is in close proximity; (3) that the plaster will be recognized as standard bv the local mechanics.
-named advantages. The result is an unusual rich.ness and "slip" which is ap-
J^cciated by the competent me chanic. They mix easily at the
J131- box; they go on quickly
. sPread far, resulting in f?Xlrnurn coverage with miniIgWwi labor.
Covering Capacity
quality of U.S.G. Plasters --r'j'y controlled by means of
> jCmical tests, physical ^bf in.,, . by every known kind rfacCuren/n C\ery StagC 0f
",
from the crude gyp-
jplesf to the finished product.
tn,it rom every shipment, large
are retained for future
RED TOP t FINISH
t UNITED STATES
GYPSUM COMPANY CHICAGO
U.S.G. Plaster Products Are Shipped in Strong Moisture-proof Multi-wall Fiber Bags
The covering capacity of U.S.G. Plasters is as great for each type of material as it is possible to at tain.
Covering capacity necessarily de pends upon conditions under which the plaster is applied--upon the mechanic, thickness of grounds, kind and trueness of the surface to be plastered, spacing or voids of lath, quality of sand, etc.
The covering capacity given hereinafter with each type of ma terial and for the various surfaces to receive the plaster is based on average conditions, and may thus be accepted as a safe basis for calculating the quantity of each class of material required accord ing to the Master Specifications given on pages !f> ;o 30 inclusive.
Pirr 1 i
I0T T 90060
t2456
United States Gypsum Company
CEMENT PLASTERS
Use for scratch and brown coats.
are uniformly satisfactory both in working qualities and ulti mate results in the finished wall.
ads
Note: See "Brands," page 11.
Red Top Cement Plaster. Red Top Eldorado Cement Plaster (Gvpsite).
Note: Gypsite plasters arc popularly known as "dark plasters." The distinguishing features of Gypsite are its long-keeping and easy-spreading qualities. Gypsite plasters are extensively used in the southwest states, as they are well adapted to the climatic and building cottditions of that section.
Package
Shipped in full weight SO-lb. and 100-lb. paper bags or 100-lb. jute sacks. Kings Windsor also supplied in 320-lb. (300 lb. net) barrels.
Covering Capacity
Note: See "Covering Capacity," page 11. Basis--Under average conditions Gypsum Cement Plaster mixed and applied in accordance with standard specifications will cover about as follows:
ription
Cement Plasters are "neat" materials--sand to be added the job.
Plastering surface Sq. yds. per ion
Wood lath
180-210 (Sanded 2 to 1)
Metal lath
105-135 (Sanded 2 to 1)
Gypsum lath
225-240 (Sanded 2 to I)
Brick and clay tile 165-200 (Sanded 3 to 1)
Gypsum ulc
235-255 (Sanded 3 to 1)
^Characteristics
_ These materials are unusually rich, spread well under the Specifications
and, when mixed properly with a good grade of sand.
See Master Specifications, page 16.
WOOD FIBER PLASTERS
[Use b Use for scratch and brown coats.
jwr|
ads
l/fote: See "Brands," page 11.
[Red Top Wood Fiber Plaster.
[Red Top Eldorado Wood Fiber Plaster (Gypsite).
...Note: Gypsite plasters are popularly known as "dark
plasters." The distinguishing features of Gypsite are its ilong-keeping and easy-spreading qualities. Gypsite plasters
are extensively used in the southwest states, as they are
well adapted to the climatic and building conditions of that section.
It is superior to sanded plaster in fire-resisting, insulating and sound-deadening qualities.
Its greater flexibility better adapts it to withstand vibra tions and strains.
Wood Fiber Plaster may be sawed like wood. It is especially adaptable to alterations and is desirable for winter use. It is nearly as economical in cost as Cement Plaster and is rapidly gaining in popularity. In many markets it is used almost exclusively.
Package
Shipped in full weight 80-lb. and 100-lb. paper bags or 100-lb. jute sacks.
aption
S*=-\Vood Fiber Plasters are shipped ready to use. requiring the addition of water. The base is Gypsum Plaster, to is added finely shredded wood fiber, uniformly distributed.
Covering Capacity
Note: Sec "Covering Capacity," page 11.
Basis--Under average conditions Gypsum Wood Fiber Plaster mixed and applied in accordance with standard speci fications will cover about as follows:
tenstics
SLWood fiber plaster avoids the handling of sand, the dan-
" of poor sand and oversanding.
.
"The very smooth and fatty nature gives easy spreading
1 excellent working qualities.
.. ,
Composed of gvpsum and shredded wood fiber, it is ot
;5Wer bulk- Whc" applied it is about two-thuds the weight
E^*-*jjnded cement plaster.
,,
Through the elimination of sand, the plaster is practically
V* gypsum, wood fiber serving as reinforcement. The plaster
^extremely lough, strong, dense and durable.
Plastering surface
Wood lath
Meta! lath
Gypsum Brick and Gypsum lath clay tile tile
Sq. yds. per ton
90-100
55-65
115-120
(Unsanded (Unsanded (Unsanded
--water --water --water
only
only
only
added)
added)
added)
150-170 (Equal parts sand to be added)
180-210 . (Equal
parts saml to be added)
Specifications
See Master Specifications, page 16.
PREPARED PLASTERS (SANDED)
LUse fir'
for
scratch
and
brown
coats.
added nothing but sharp, clean plastering sand, thoroughly graded and screened.
Correct proportions_ and mixing are accomplished by auto matic machines at the factory.
tNotc: See "Brands," page 11. l^ed Top Sanded Plaster.
Top Sanded vRtd Top Sanded
Plaster for Brick or Wood Fiber Plaster.
Tile.
ription
t*repared Plasters are shipped ready to
' Edition of water.
The
base
is
Gypsum
use. requiring only Plaster to which is
Characteristics
Prepared plasters are especially desirable in localities where good sand is difficult to obtain.
Since they are ready to apply with the addition of water only, they are particularly well adapted for use in winter when unfrozen sand is difficult or expensive to obtain.
Since these plasters may be readily mixed inside the build ing, they are useful for repair and remodeling work in all seasons.
PAGE 12
Contmuec on next page
Z0TT 9cos0
United States Gypsum Company
B2457
Package
Shipped in full weight 80-lb. and 100-lb. paper bags or 100-lb. jute sacks.
Covering Capacity
Note: See "Cohering Capacity," page 11. Basis--Under average conditions Gypsum Prepared Plas ter mixed and applied in accordance with standard specifica tions will cover about as follows:
Plastering surface Sq. yds. pwf ton
Wood lath
Metal lath
Gypsum lath
Brick and clay tile
Gypsum tile
60 to 70 35 to 45 j 7S to 80 45 to 55 65 to 70
(Plaster mixed with water oniy--no sand added)
Specifications
See Master Specifications, page lb.
BONDCRETE--FOR INTERIOR CONCRETE SURFACES
Use
Use for both scratch and brown coats applied over concrete surfaces.
Description
Bondcrete must not be applied over smooth concrete. Bondcrete must not be covered with a sanded brown coat-- use only Bondcrete full to the grounds. Bondcrete may be finished with any of the finishes described on this and the following page.
Ordinary gypsum plaster or lime mortar does not ad here properly to concrete--consequently the use of Bondcrete, a specially made plaster for concrete surfaces, is recom mended.
Package
Shipped in full weight 80-lb. and 100-lb. paper bags or 100-lb. jute sacks.
Characteristics
Bondcrete Plaster adheres strongly to dry concrete because of its cementitious qualities and because it maintains a prac tically unchanging volume during the process of setting and hardening.
Bondcrete is dense, durable and fire-resisting. It works well under the tools, and needs only water to make it ready for use.
Covering Capacity
Usually from 90 to 120 sq. yds. to the ton coverage depend ing upon regularity of concrete surface and thickness applied.
Note: Sec "Covering Capacity," page 11.
Specifications
See Master Specifications, page 16.
RED TOP TROWEL FINISH
Note: This finish is also furnished mixed with a small percentage of aggregate for texturing purposes.
Use
Use for white trowel finish coat only.
is necessary and because the finish is mixed in the box instead of on the hawk, it is economical. It contains no talc, clay or other objectionable ingredient. The alkalinity of the lime con tent is reduced by chemical action, so that the walls may be safely decorated as soon as dry.
Description
Of exceptionally fine quality is this prepared trowel finish, which works as easy and covers as much surface as lime putty. The admixture of water fits it for immediate use. Numerous field tests have convinced us that this is the ideal prepared finish.
Characteristics
It mixes easily to a light, creamy consistency and can be applied in two coats. Because no slaking or soaking of lime
Package
Shipped in full weight 80-lb. and 100-lb. paper bags.
Covering Capacity
Coverage equal to lime putty and more than any other prepared finish--450 to 500 sq. yds. per ton.
Specifications
See Master Specifications, page 16.
Use
Use for finish coat only.
PREPARED GYPSUM FINISHES
clean silica sand, properly graded, screened and thoroughly dried.
Brands
Note: See "Brands," page 11.
Trowel Finishes
Red Top Universal White Trowel Finish. Red Top Adamant Trowel Finish (White). Red Top Adamant Slate Colored Trowel Finish. Red Top Badger Trowel Finish (Gray).
Characteristics
These finishes are ready to use when water is added, assur ing a uniform mix of correct proportion. The sand float fin ishes are especially recommended in winter when unfrozen sand of the requisite quality is difficult to obtain. Decora tions may safely be applied as soon as the finish dries out.
Package
Sand Float Finishes
Red Top Silica Sand Float Finish (White). Red Top Adamant Gray Sand Float Finish. Red Top Adamant White Sand Float Finish. Red Top Sand Float Finish (Gray).
Description
Prepared Gypsum Finishes require only the addition of ^'ater to make them ready for use. Made of gypsum, they |rm a perfect and natural bond with any gypsum plaster base coat. The sand fioat finishes contain selected sharp
Shipped in full weight 80-lb. and 100-lb. paper bags or 100-lb. jute sacks.
Covering Capacity
Under average conditions Gypsum Trowel Finish, if mixed and applied in tccordance with standard specifications, will cover about 350 to 400 yds. per ton; Gypsum Sand Float Finish about 250 to 275 yds. per ton.
Specifications
See Master Specifications, page 16.
ORIENTAL INTERIOR--COLORED FINISH PLASTER
Use
is made in thirteen standard shades and white. Tints are pro
Use for textured or floated plaster finish coat.
duced with mineral colors, great care being taken to assure absolute uniformity of shade.
Description
Oriental Interior is ready for use with the addition of water only. It is used as a finish coat over the regular base
Oriental Interior is a colored finish plaster. The material coat of plaster and can be floated or textured.
Sweet'*
PAGE 13
Continued on next page
t o n 90008
4B245S
United States Gypsum Company
(Characteristics
t With ordinary tools, attractive, tinted, float or textured (finishes may be obtained with Oriental Interior in perfect {accord with modern decorating practice. Tile or stone unit reflects may be produced by scoring walls before Oriental Intterior has hardened. t: Change of color scheme may be accomplished at any time by "the application of paint or other decorative mate-
1 Unvarying uniformity in both color and quality is assured.
(.The material is scientifically mixed at the mill--the addition tof water only is required for immediate use. * The positive regulation of color insures walls with the
minimum amount of "joinings" and avoids the danger of in accurate mixing
Package
Shipped only in full weight 100-lb. paper bags. color name designated on color cards or samples.
Order by
Covering Capacity
The covering capacity of Oriental Interior finish is approxi mately 250 sq. yds. per ton, varying according to textures.
Specifications
See Master Specifications, page 16.
FINISHING LIME
|Use
Use finishing lime for finish coat only in conjunction with 55uging plaster described below.
|Brands
Note: See "Brands," page 11.
Hydrated Finishing Lime
Red Top Ivory Finish Lime. Red Top Grand Prize Finish Lime. Red Top Finish Lime. Farnam Cheshire Superior Hydrate.
Finishing Quick (or Common) Lime
Farnam Cheshire Finishing Lime--in Lump, Pulverized, jranular and Superfine.
Berkshire Hills Crescent Finishing Lime--in Granular and tPnlverized.
VST
cripfa'on
iThese limes are specially prepared for finishing purposes, ey possess a rich plasticity that makes them spread easy and rW; hence they save time and labor.
acteristics vHydrated lime saves the time and trouble of slaking and
ning lime on the job. The famous Ohio dolomite from Red Top hydrated lime is made, together with U.S.G.
ards of manufacture, make this lime unexcelled for fin
ishing purposes. It is uniformly burned and thoroughly hydrated, is of a snowy white color, and is absolutely free from "pops" and "pits." It meets the standard specifications for hydrated lime of the American Society for Testing Mate rials.
Farnam Cheshire and Berkshire Hills Limes are burned from selected high calcium rock and are of exceptional quality. Because of their exceeding purity and the physical character istics of the stone, these limes are unusually quick slaking and arc free from popping and pitting. They have a high putty yield.
Package
Hydrated Lime is shipped in full weight 10-lb. and 50-lb. paper bags. Quick Lime is shipped in 180-lb. and 280-lb. net weight wood barrels and steel drums, also in bulk. The Superior and Granular Quick Lime is shipped also in 80-lb. Multi-Wall paper moisture-proof bags.
Covering Capacity
Under average conditions one ton of Red Top Hydrated Lime, when used in proportion of two parts of dry lime to one part of dry gauging plaster by weight, should finish about 800 sq. yds. A ton of Quick Lime, when mixed in the above pro portions, should finish about 1000 yards.
Specifications
See Master Specifications, page 16.
MASON'S LIME
Note: The United States Gypsum Company also manujacturcs a high-grade Agricultural Lime.
life
jgA* a mortar for setting brick, stone, etc., and for mixing Portland cement and concrete.
ft-Note: Sec "Brands,'' page 11. Hydrate Brands
.Ked Top Mason's Hydrate. -Parnam Cheshire Superior Hydrate. ?^ason * Quick (or Common) Lime Brands
?,c^ Top Pebble Li me. 1 ^ .'V. Mason's Quick Lime, in Lump, Granular, and cJ*v*nzed.
arnam Cheshire Mason's Quick Lime, in Lump, Pebble, niiar and Pulverized.
Description
The use of lime for mortar means more bricks laid per hour, no loss in droppings, no loss from hardening in the mor tar box, and no time lost in mixing or retempering.
Red Top and U.S.G. Mason's Hydrate are prepared limes of uniformly high quality, requiring no slaking on the job.
Of excellent quality also is our Mason's Quick Lime. It is exceedingly quick slaking and yields a putty of high sand carrying capacity.
Package
Mason's Hydrate is shipped in 50-lb. paper bags. Mason's Quick Lime is shipped in 180 or 280-lb. wood barrels or steel drums, also in bulk.
Proportions Recommended
1 part lime putty to 3 parts sand, by volume. Or 8 sacks of hydrate, or 8 cu. ft. of putty to 4 sacks Portland cement and 1 cu. yd. of sand.
rife '^above'TM5*1 Cat
GAUGING PLASTERS
'n coniunct'on whh *`me Putt>' ^e'
Red Top Kings Diamond Gauging Plaster (White). Red Top NYC Mills Gauging Plaster.
Description
: ^cc "Brands," page 11.
jlovr Set
These plasters are made of raw materials carefully selected from gypsum deposits unusually well suited for the manufac ture of calcined plasters for this particular purpose.
jrP.j ?P Slow Set Gauging Plaster (Gray). SP Star Gauging Plaster (White).
E&Reri m011 Vperfine Finishing Piaster (White). W7 ,rp Plater Paris for Painters. \Quick Set
Characteristics
They are made in both "slow set" and "quick set," and arc uniformly ground to just the right fineness to insure easy working and mixing qualities.
Ejlcd op Quick Set Gauging Plaster (Gray).
- op Champion Gauging Plaster (White).
Package
Shipped in full weight 80-lb. and 100-lb. paper bags; 100-Ib.
PAGE 14
Continued on next pane
V0TT 90068
United States Gypsum Company
B 2459
100-11' paper-lined jute sacks; 250-lb. (230 lbs. net) f32u-lb.\3U0 lbs. net) barrels.
Capacity Under average conditions one ton of Gauging Plaster,
mixed one part of dry gauging to two parts of dry hydrated lime by weight, will cover about 1600 sq. yds.
Specifications
See Master Specifications, page 16.
RED TOP KEENE'S CEMENT
t'se for high grade plasterwork. particularly to receive fine tiTe treatment and where the utmost in sanitation is
ription
~>Red Top Keene's Cement is the hardest and densest gypsum "Serial that is applied with a trowel. It is manufactured from
dally selected gypsum mined at Southard, Oklahoma. Red op Keene's Cement excels in smooth, uniform working qual` i and in tensile strength, due to the selected material and the U.S.G. improved methods of manufacture and rigid mill in spection.
Note: Red Top Keene's Cement is regarded by many man ufacturers as the best on the market }or scagliola xaork.
white in color and takes a very high, glass-like polish. Its ex tremely^ hard surface is impenetrable to rodents and vermin and ahords no lodgment for disease germs. It is easily cleaned It contains no alkali to stain delicate wall tints or saponify the oil in paints, hence it is an ideal base for fine decorating.
Package
Shipped in 100-lb. jute and paper-lined jute sacks.
Covering Capacity
Under average conditions one ton of Keene's Cement, when used neat and in accordance with specifications, will cover about 400 to 500 sq. yds.
Characteristics
Specifications
Keene's Cement is ground to extreme fineness, is pure
See Master Specifications, page 16.
RED TOP (ARIDIZE) MOULDING PLASTERS
Use
A Use for ornamental moulded plaster work.
great strength, and breakage by handling and manipulation in the moulding and casting stage is diminished.
Brands
Note: See also "Brands," page 11.
- jjy. Red Top Moulding Plaster. Red Top No. 1 Moulding Plaster (White).
.Description
The requirements for moulding plaster arc distinctly dif.ferent from any other class of plaster. Gypsum deposits suit able for making this material are exceedingly rare.
These plasters are produced by a manufacturing process, patented by the United States Gypsum Company, which arti ficially ages the plaster, giving it those desirable characteristics of easy mixing and great hardness not obtainable in ordinary plasters until 8 to 12 months' ageing. y- Heretofore, plasters have been aged by storing in waresouses but the results could not be uniform because of varia tions in temperature and humidity conditions. The production of Aridize Plasters, however, depends in no way on the atmos pheric conditions, for an artificial atmosphere is produced at a tonperature and humidity that will assure uniform ageing; con sequently the plaster is always uniform.
Pre-ageing lowers the water carrying capacity of the P"*ter; hence Aridize Plasters set into denser, stronger and aore durable moulds.
Even when green, moulds made of these plasters possess
Characteristics
Aridize Moulding Plasters are made from selected gypsum ideal for the purpose and unequaled for whiteness and purity. This, together with the special patented process of manufac ture, produces a particularly smooth working plaster of abso lutely uniform setting quality.
These plasters are ground much finer than other similar products, assuring a more thorough solution and a finer sur face to the finished work, with an absence of pinholes. The fine satin-like surface increases the life of the moulds.
In addition to these qualities, the plasters are cooler work ing and slower setting, which accounts for low expansion and absence of warped moulds. The slow generation of heat in setting insures protection to gelatine or glue moulds. Slow setting gives time for blending and working out trapped air bubbles and working the plaster into angles and corners of moulds.
Package
Shipped in 80-lb. and 100-lb. paper bags; 100-lb. jute and paper-lined cloth sacks and 250-lb. (230 lbs. net weight) barrels and in 320-lb. (300 lbs. net weight ) barrels.
Specifications
See Master Specifications, page 16.
RED TOP PATCHING PLASTER
u*
Specifications
fr filling cracks and abrasions in plaster. Especially Pted to the repairing of old work preparatory to refinishing.
Description
Mixing--Pour the dry plaster on a clean, smooth board and form a central depression (bowl shape), into which pour clean water.
ior ^"P ^atching Plaster is the finest material obtainable
Imifo '"I* plaster cracks, breaks and crevices. It is white, orrn m quality, works easily, goes far and is quickly applied.
Ek^cteristics
Thoroughly work the plaster into the water with a putty knife or semi-flexible scraping knife, adding water or plaster as required to produce the proper consistency.
Mix only in small batches that can be entirely used in 30 minutes. Do not retemper.
The set is regulated to permit ease in spreading and proper stremf Wlt{10ut shrinkage cracks. The plaster makes a hard,
fttlcim' sur`ace that withstands wear and tear and takes paint,
Colora!"6'
PaPer ot Textone like a new wall, without dis-
'wai.r.IOn'i_- Top Patching Plaster mixes easily with clean
' nthing else is to be added.
ekage
Application--Cracks shall be cut out to approximately Vs in. in width. Abrasions shall be cleaned of all loose mate rial.
Apply the patching plaster with a putty knife, semi-flexible scraping knife or small trowel as best adapted, using sufficient force to fill the crevice completely.
Smooth carefully, making the surface level with the sur rounding surfaces.
t? cc"vcnier.t 21~>-lb -y* llh a distinctive red top.
and I5-lb.
After the patching plaster has set hard, smooth carefully with fine sandpaper.
^WEETs
PAGE 15
c.
f i O I I 9 0 0 faB
MASTER SPECIFICATIONS
PREFACE
Specification Form . The form of this specification is that of a "Master" j. which includes all clauses which in ordinary practice ; applv to average work. All clauses, obviously, do not ^ apply to every building. In formulating the "Interior
Lathing and Plastering Specifications" for a particular building, only those clauses which apply should be ser lected for inclusion. Special provisions or methods but l seldom required are not included--such clauses should b be added wherever necessary to clearly define the proi, cedure and especially to obviate controversy involving i_ responsibility' and cost.
r Local Ordinances Correlate these specifications with the requirements
of Local Ordinances and Trade Customs relating to this Sr division of the work.
Alterations and Additions
These specifications cover new work only. For T additions and alterations add such clauses covering re-
pairs and replacements and the joining of old and new L work as may be required.
Advisory Service
The technical staff of the United States Gypsum Company is at all times accessible tor advice and recom mendations in the formulating of the specification for Interior Lathing and Plastering. Special data, the result of much extended research work, relating to the selection and application of Interior Plastering and "Explanations of Job Conditions which Affect Plastering" will be fur nished on request.
Notea
Notes in italics are explanatory or advisory only and should not be included in the specification.
Selective Words or Phrases Wherever words or phrases occur in the body of
the specification paragraph printed in italics and en closed in parentheses, choose that word or phrase which applies to the particular work, omitting those that are irrelevant. Wherever the word "specify" occurs in italics enclosed in parentheses, thus (specify), add the particular word or clause applicable, optional with the specification writer.
INTERIOR LATHING AND PLASTERING
Note: For complete guaranteed and bonded plastering system see Standard X Plastering System, page 2.
Note: For exterior stucco, see Oriental Exterior Stucco, page 21.
Note: For Sabinite Acoustical Plaster, sec Sweet's Manu facturers' Index for the United States Gypsum Com pany's complete catalogue covering "Fireproof Sound Absorbents--Acoustical Treatment" and "U.S.C. System ~ f Sound Insulation."
(1) General Conditions
a The general conditions governing the General Contract ^PPly to the work under this division.
-- Note: The American Institute of Architects' standard ri fT,n of General Conditions is advocated.
?(2) Work Included
.(2a) The work included under this heading shall be the "owing;
(3f) Exterior walls are not furred. Plaster shall be ap plied directly on the (specify).
(3g) Partitions are of (specify).
(3h) Walls back of finished tile work shall be lathed only. No plaster shall be applied.
(3i) Omit all plaster on interior masonry walls and (hollow tile) (Pyrobar) partitions back of marble work.
(3j) All exterior masonry walls, not furred, shall receive one coat oi plaster back of marble work.
(3k) Omit the finish coat of plaster on all stud walls back of (marble work) (blackboards) (specify).
(31) Omit the finish coat of plaster back of all (wood wainscots) (specify) and similar solid trim.
(3m) (Specify) shafts shall be plastered full height.
(3n) All chases in unfurred masonry walls which are to be plastered shall be lathed with metal lath. Lap the masonry at least 3 in. and secure at masonry joints. Wide chases (over 16 in.) shall be furred to receive lath.
(2b) Al| rnetal suspended or furred ceilings. (2c) All metal stud partitions (2d) AH metal wall furring. (20 All miscellaneous metal furring. ^ (2f) All lathing. s|""/2g) All plastering.
General Scope
S'- ^a,`d locate either in schedules on plans or here portions of the building to be finished, the base to receive P aster and here include sufficient data to insure accuracy r.m tshmates.
jT (3a) The following require no plaster (list and locate).
(4 ) Scaffolding
(4a) This contractor shall provide and erect all scaffold ing. staging, etc., necessary for the proper execution of his work.
(4b) He shall co-operate with other trades to the extent that erection ol scaffolding shall not conflict with the execution of other work immediately preceding or carried on, without undue conflict, simultaneously with the lathing and plaster ing.
(4c) !f, after hie authority has been granted to erect scaffolding, it is necessary to remove parts thereof for the accommodation of others, demolition and re-erection shall be done only after allocation of cost, if any, has been equitably adjusted.
The following require but (one (1)) (two (2)) coats g_pwsier (list and locate).
PrO Ceilings noted as furred (on plans) (in schedules) red with (metal) (gypsum board) (wood).
^(3d) All supports for lath are spaced 16 in. on centers.
^(2*) AH exterior walls are furred with (specify).
(5) Heat
(5a) Adequate temporary heat will be provided by otherfor the proper execution of work under this contract.
(5b) This contractor shall provide salamanders, fuel and attendance and shall maintain without fire hazard adequate heat for the proper execution of work under this contract.
PAGE 16
Continuea on next page
9011 90060
II li
United States Gypsum Company
B2461
(6) Closures
(6a) Provide temporary cloth closures for all exterior openings during plastering.
(15) Workmanship
All work shall be executed by skilled workmen in a manner to satisfactorily fulfill the provisions of these specifications.
(6b) During the summer months exterior openings shall be screened to prevent plastering drying out before it has crystal lized.
(16) Examination
(16a) All construction to receive lathing and plastering is presumed to be substantial, sound, level, plumb and true.
(7) Protection
(7a) Adequately protect from damage and plaster drop pings all finish of the building.
(7b) Adequately protect the building with layers of heavy waterproof paper from damage by water at sources, gauging barrels and mixing boxes.
(8) Damage Breakage of glass or other damage to the building or
equipment through accident or carelessness incident to work undeT this contract shalt be satisfactorily repaired or made good by replacement at this contractor's expense.
(9) Cleaning
(9a) At completion, remove all rubbish, plaster droppings, etc., and leave the building broom ciean.
(9b) This contractor shall remove all plaster from glass and other finish and leave in the condition found.
(10) Cutting and Patching
After the erection of finish by others, this contractor shall, when called upon, cut out where required, patch and paint up all finished plaster work and leave the entire work in perfect condition.
(16b) This contractor shall examine all construction, sup ports and base to receive lathing and plastering and shall report to the architect in writing any defects which will deleteriously affect work under this contract.
(16c) Failure to so report defects for correction or replace ment prior to execution of the work under this contract will be construed as acceptance of the construction and shall not relieve the contractor from obligation under his guaranty.
(17) Materials and Mixing
(17a) General--Store all plaster at the site in a dry place, raised above the bare ground.
Provide clean, water-tight mixing boxes (approximately 3V'ex7 tt.xlO in. deep for base coats and 2Vjx4Vi: ft.xl0 in. deep for finish coats) raised 4 in. at one end. Clean mixing boxes after each gauging.
Tools shall be kept clean. Do not rinse tools in gauging water.
Do not mix more material than can be applied in approx imately one (1) hour.
Do not mix one gauging with another. Never retemper plaster after it has commenced to set.
All material except sand (wood lath) shall be as manu factured by the United States Gypsum Company.
(17b) Water--Water shall be clean, free from alkali and impurities.
(11) Sample Panels
This contractor shall furnish and erect, where directed for the approval of the architect, sample panels of one square yard area each, to illustrate each type of finish required under this contract.
The finished work shall equal in all respects the approved panels.
(17c) Sand--Sand shall be dean and sharp and free from organic matter with grains graded from fine to coarse, meeting fully the Standard Specifications for Plastering Sand of the American Society for Testing Materials. Screen through a 6-mesh screen.
(17d) Metal Furring--(Specify sices) Red Top Cold Rolled Channels.
Note: See page 8.
(12) Concrete Surfaces
Note: Concrete surfaces to receive plaster must not be smooth. Use rough form boards. Avoid dressed or oiled boards.
(12a) Concrete surfaces must be half green and free from dust, oils and efflorescence.
(12b) Burn off all oil or grease from the surface with a torch.
(12c) Remove efflorescence with a wire brush and wash with a one (1) to five (5) solution of muriatic acid and water. Thor oughly wash off acid with clean water.
(17e) Metal Partition Studs--(Specify sizes) Red Top Cold Rolled Channels.
Note: Sec page 8.
(17f) Wood Lath--No. 1 (white pine) (cypress) (spruce) free from knots, sap and bark.
(17g) Gypsum Lath--Rocklath % in. thick, 16x32 in. and 16x4S in.
(17h) Metal Lath--(Specify brand, material and finish) lath; ------ lb. for horizontal positions and -------- lb. for vertical positions.
Note: See pages S. 9 and 10. Select and specify weight for both horizontal and vertical positions.
(12d) Surfaces too smooth to receive plaster shall be thor oughly hacked.
(12e) Hacking will be done by others.
(13) Grounds
All lathing and plastering shall be laid to not less than me following grounds:
*4 in. for Vi in. gypsum lath, wood, wire or expanded netal lath; % in. for % in. gypsum lath; % in. for brick or "ay tile; Vi in. for Pyrobar.
(17i) Comerite--Red Top or VPS Cornerite, 3x3x96 in. with special selvage edge.
Note: See pages S and 10.
(17j) Comer Beads--Red Top Corner Bead No. (specify) Note: Sec page 8.
(17k) Base Screeds--Rep Top Base Screed No. (specify). Note: Sec page 8.
(171) Metal Picture Mould--Red Top Picture Mould No. (specify).
Note: See page 8.
(14) Guaranty
(14a) This contractor shall guarantee all work and mate^ols under this contract for a period of (specify) from the date t completion and acceptance.
(14b) Any defects attributable to faulty workmanship or "'sterial furnished under this contract shall be made good at "'ts contractor's expense.
(17m) Metal Expansion Casings--Red Top Expansion Casing No. (specify).
Note: Sec page 8.
(17n) Base Plaster (Scratch and Brown Coats)-- Note: Select type best adapted.
(17nl) (Specify brand) Cement Plaster (Unsanded)-- Note: Sec page 12.
(14c) This shall include the cost of repairs or replace
ment of any decorating or other finish damaged bv the defects.
(a) For scratch coat on gypsum lath, wood, wire and
expand -d metal lath, mfx 2 parts by weight of dry sand with 1 part of plaster.
Sweet's
PAGE 17
Continued on next page
3B006 1107
B 2402
United States Uypsum Company
(Jj) For brick, Pvrobar gypsum tile, clay tile and second or brown coat, mix 3 parts by weight of dry sand with 1 part of plaster.
(c) Do not mix sand and plaster until ready to add
water. (d) First put in the mixing box a layer of sand, then one
of plaster in raised end of box. Hoe dry from one end of box to other and then back again, working sand and plaster thoroughly together to a uniform color. Put water in other end of box : hoe plaster into the water, mixing thoroughly. Mix thin with water at first, then bring to the proper consistence for appli cation by addition of properly proportioned dry sand and plaster.
(17n2) (Specify brand) Wood Fiber Plaster-
Note: Sec page 12. (a) Neat--Put the plaster in upper end of mixing box and water in lower end. Hoe plaster into water and allow to soak from 10 to 20 minutes. Then mix to proper consistence for application. Note: Used for -wood lath and gypsum lath and scratch coat on zaire and expanded metal lath. See "Application of Base Plaster," page 19. (b) Sanded--Mix equal parts by weight of plaster and dry sand. Mix as specified above in (a). Note: Used for brozen coat on zaire and expanded metal lath and for all plaster on brick, Pyrobar gypsum tile or clay tile.
(17n3) (Specify brand) Prepared Plaster (Sanded)--
Note: Sec page 12.
(a) Add nothing to the material but water.
(b) Put the plaster in upper end of mixing box and water in lower end. Hoe plaster into water, mixing thoroughly. Mix thin at first, then add sufficient dry material to bring to the proper consistence for application.
(17p) Sand Float Finish--
Note: Select type best adapted.
(17pi) (Specify brand) Prepared Gypsum Sand Float Finish--
Note: See page IS.
Put the finish in the upper end of mixing box and water in lower end. Hoe finish into water. Allow the material to soak and draw in the water without hoeing for at least 10 minutes. When the material has soaked and shows no further signs of air bubbles, mix thoroughly and, with particular care, break down the mix to a smooth, even, creamy consistency. Transport in buckets.
(17p2) (Specify brand) Sand Float Finish (Job Sanded)--
Note: See page IS.
Screen sand through a Xo. 12 screen. Mix dry to a uni form color 1 part of Cement Plaster to 1 part of dry sand by weight (equal to from 4 to 6 shovels of sand to each 10O-Ib. bag). Put dry mix in upper end of box and water in lower end. Hoe material into water and mix thoroughly to a smooth creamy consistence. Transport in buckets. Keep tools and box clean.
(17q) Oriental Interior (Colored Float or Texture Finish)--
Note: See page 13.
(17ql) Color(s) shall be (specify) as subsequently deter mined upon.
(17q2) Put the Oriental Interior in upper end of box and water in lower end. Hoe material into water, using approxi mately 1 part water to 2 parts Oriental Interior, by volume. Let Oriental Interior soak overnight (not over 24 hours). After soaking, mix thoroughly and carefully hoe the mix to a smooth, creamy consistence. Transport in buckets.
(17n4) Bondcrete (For All Concrete Surfaces)--
Note: See page 13. (a) For both scratch and brown coats.
(b) Add nothing to the material but water. (c) Put the plaster in the upper end of mixing box and Her in lower end. Hoe plaster into water. Allow the material to soak at least 10 minutes. Mix thoroughly and break down toe mix to a smooth, even creamy consistence.
(17o) Trowel Finish--
Note: Select type best adapted.
(l7ol) Red Top Trowel Finish--
Note: See page IS.
Put the finish in the upper end of mixing box and water
'the lower end (S to
gals, to the 80-lb. bag). No soaking
J* .necessary. Mix thoroughly. Add more water if necessary to
bring to a light, creamy consistency.
(17o2) (Specify brand) Prepared Gypsum Finish--
Note: Sec page IS.
Put the finish in the upper end of mixing box and water lower end. Hoe plaster into water (using approximately -UP311 f water to 2 parts of plaster measured by volume). JyOW the material to soak and draw in the water without hoc8 tor at least 10 minutes. When the material has soaked and -wiST5 n- ll,rtoer signs of air bubbles, mix thoroughly and, "particular care, break down the mix to a smooth, even, .omy consistence. Bring the mix finally to a very thin contence. Transport in buckets.
(17r) Red Top Keene's Cement-- Note: Sec page 15. Clauses below are for finish coats only.
(17rl) Add water only, mix thoroughly and bring to a working consistence.
(17r2) Add 1 pail of lime putty to each 100-lb. bag of Keene's Cement where extra plasticity is required.
(17s) (Specify brand) Aridize Moulding Plaster-- Note: Sec page 15. (17si) Add water only, mix thoroughly and bring to a working consistence.
(17s2) Add 50% lime putty to the moulding plaster where extra plasticity is required for run work.
(18) Furred or Suspended Ceilings
W'here so indicated on plans (or listed in schedules) ceil ings shall be furred or suspended with metal furring members.
Note: Describe construction. Apply to the United States Gypsum Company for specifications for metal lath and gypsum lath systems.
(19) Metal Stud Partitions
Where so indicated on plans, partitions shall be constructed of metal studding.
Note: Describe construction. Apply to United States Gypsum Company for specifications and details.
(Specify brand) Finishing Lime and (Specify Z-"nd) Gauging Pfas ter--
Note: Sec page 11.
th'^a (Hydrated Lime) Fill watertight box one-half to
full of clean water. Add dry lime gradually, prefersifting through a ',4-in. mesh screen, until all water is - UP- Allow lime to soak overnight to develop full plasticity. 01 hoe or screen after soaking unless lime is dirty or lumpy.
in^^ (Quick Lime) Add water and lime gradually while
toe; S' constantly agitating the mixture to prevent burning of ;I!f a'cet^ Portion. Mix to a thin consistency and screen. mto ageing box.
3 parts of lime putty by measure with 1 part of
Part
Poster (equal to 2 parts of dry hydrated lime and
i.. 1 "O' gauging piaster by weight). Mix thoroughly.
(20) Metal Wall Furring
W'here so indicated on plans (or listed in schedules) ex terior walls shall be furred with %-in. channels spaced (specify) on centers with flange to wall. Furring channels shall be secured to floors and ceilings in a substantial manner and shall be substantially secured to walls with special hook nails driven into the mortar joints. Provide rigid framing at all openings.
(21) Miscellaneous Metal Furring
Provide of 94-in. channels, furring for all (false beams) (ornamental plaster cornices) (stair soffits) (specify), etc., as shown on the plans and as detailed. Furring shall be set (specify) on centers and rigidly secured to the building con struction.
PAGE 18
Continued on next page
BB006 1108
(22) Application of Wood Lath
*(22a) All (exterior stud walls) ('wood furring) (interior stud partitions) (ceiling joists) (stair soffits) (specify) shall be lathed with wood lath. Lath shall be spaced not less than }i-in. nor more than %-in. apart and shall be secured to each bearing with standard wood shingle nails, two (2) to each end and one
(1) to intermediate bearings. Lathing shall break joints everv eight laths, all put on
horizontally. Under no circumstances shall lathing stop and form a long, straight, vertical joint nor be put on vertically to finish out at angles or corners; neither shall any lath run through and behind studding from one room to another. All corners must be made solid before lath is applied.
(22b) All re-entrant angles shall be reinforced over the wood lath with Cornerite. Strips shall butt (not lap) at ends
and shall be substantially secured.
(23) Application of Red Top Rocklath
All (exterior stud u-alls) (wood furring) (interior stud partitions) (ceiling joists) (stair soffits) (furred or suspended ceiling) (metal stud partitions) (specify) shall be lathed with Red Top Rocklath.
(23a) Cutting shall be done by scoring with a sharp hatchet or knife and then breaking down and up over a straight edge.
Kails shall be 1% in., 13 gauge, 'Is-in. head, blued, long point, sterilized nails.
Red Top Rocklath boards shall butt with broken joints in each course. Stagger joints between walls and ceilings so the vertical joints on wall will not meet ceiling joints.
Fit Red Top Rocklath tight together at all re-entrant angles and corners. Cut accurately and fit Red Top Rocklath neatly around all electric outlet boxes, etc.
Space nails 4 in. apart at every support, nailing to center support first, then outer edges. Each nailing edge must have a firm bearing on studs, joists and furring. Drive nails home.
(23b) All re-entrant angles shall be reinforced over the Red Top Rocklath with Cornerite. Strips shall butt (not lap) at ends and shall be substantially secured.
(24) Application of Metal Lath
All (exterior stud walls) (wood furring) (interior stud Partitions) (ceiling joists) (stair soffits) (furred or suspended ceilings) (metal wall furring) (metal stud partitions) (miscel laneous metal furrings) (specify) shall be lathed with metal lath.
Note: Complete specifications will be sent by the company on request.
(25) Corner Beads
All corners (both vertical and horizontal) shall be protected with corner beads for their full height (or length).
Note: If there arc exceptions so note. Comer beads shall be substantially secured, accurately set, nb, true and straight.
(26) Metal Base Screeds
The following rooms shall have base screeds: fote: List and locate either in schedules on plans or here. ^Screeds shall be substantially secured, accurately set. straight
1116 10 line and parallel with the finished floor line.
=v?)
Picture Moulds
^Rowing rooms shall have metal picture moulds; a,,d locate either in schedules on plans or
*tra'1Ib mou^s shall be substantially secured, accurately ar,d true to line and parallel with the ceiling line.
^Metal Expansion Casings
following openings shall have metal expansion casings: here* *~'sl a,,d locate cither in schedules on plans or
fusion casings shall be accurately set in line with jambs
ir. accordance with details. Secure with screw's and locking metal clips. Provide one-piece stamped casing miters.
(29) Application of Plaster--General
Keep plaster from freezing for 24 hours after application. Do not apply finish coat on a base coat which contains frost. In hot, dry weather screen all openings while plastering to prevent material drying out before it has set. If plaster should dry out (showing soft, white spots or areas) sprinkle those portions so affected with clean water from a spray pump or a brush. After plastering has set, open the windows and permit the wall to dry out as quickly as possible. Use judgment in pro cedure during freezing weather. For grounds see "Grounds," page 23. Unless specially otherwise noted, all plaster shall be applied in three (3) coats-- scratch, brown and finish. Scratch coat shall be applied and the surface well scratched. When scratch coat is set and nearly dry, follow with brown coat. Brown coat shall be brought lu a true level plane with rod and darby flush with the grounds, ready to receive finish coat. Angles and corners shall be left straight, true and plumb.
(30) Application of Base Plaster (Scratch and Brown Coats)
(30a) Cement Plaster and Prepared Plaster--
(30al) On Wood Lath--Soak lath thoroughly the day before and again an hour or so before applying the plaster. Apply in two (2) coats, scratch and brown, the scratch with sufficient pressure to obtain a good key. Darby the brown coat lightly, and use water sparingly.
(30a2) On Gypsum Lath--Do not wet lath. Apply in two (2) coats, scratch and brown. Scratch coat shall be well scratched in to fill all interstices between lath boards. Darby brown coat lightly and use water sparingly.
(30a3) On Wire or Expanded Metal Lath--Apply in two (2) coats, scratch and brown. Scratch coat shall be applied lightly covering the lath and filling meshes. Darby brown coat lightly and use water sparingly.
(30a4) On Brick, Pyrobar Gypsum Tile, or Clay Tile-- (Soak brick or tile walls thoroughly.) (If necessary, sprinkle Pyrobar lightly to reduce suction.) Apply in two (2) coats, scratch and brown, and fill out to grounds. Darby lightly and use water sparingly.
(30b) Wood Fiber Plaster-- Note: Neat tl'ood Fiber Plaster may be troweled down to a smooth finish omitting further finish coat. If desired, so specify.
(SCbl) On Wood Lath--Soak lath thoroughly the day before and again an hour or so before applying the plaster. Apply scratch coat with sufficient pressure to obtain a good key. Rake or scratch the surface. Apply brown coat using sufficient material to fill out to the grounds.
Before the plaster begins to set, broom the surface to receive the finish coat.
(30b2) On Gypsum Lath--Do not wet lath. Apply in two (2) coats, scratch and brown. Scratch coat shall be well scratched in to fill all interstices between lath boards. Before the plaster begins to set, broom the surface to receive the finish coat.
(30b3) On Wire or Expanded Metal Lath--Apply in two (2) coats, scratch and brown. Scratch coat shall be applied a little stiff, covering the lath and filling meshes. Brown coat shall be applied to fill out to the grounds. Before the plas: r begins to set, broom the surface to receive the finish coat.
(30b4) On Brick, Pyrobar Gypsum Tile or Clay Tile-- (Except over dampprooj paint.) (Saak brick or tile walls thor oughly.) (If necessary, sprinkle Pyrobar lightly to reduce suc tion.) Apply in two (2) coats, scratch and brown, and fill out to the grounds. Before the plaster begins to set, broom the surface to receive the finish coat.
(30c) Bondcrete (For All Concrete Surfaces)--
Note: See paragraph 12, page 17.
Note: Bondcrete may be troweled down to a smooth finish omitting further finish coat. If desired, so specify.
Apply in two (2) coats, scratch and brown, and fill out to grounds.' Before the plaster begins to set, broom the surface to receive the finish coat.
BB006 1109
PAGE 19
C ontmuea on next page
B 2464
United States Gypsum Company
(31) Application of Trowel Finish
(31a) Location--The following shall receive trowel finish:
Note: List and locate either in schedules on plans or here
(31b) Prepared Gypsum Finish--
Base coat must be half green before finish is applied. If suction is too great, sprinkle lightly with clean water from a clean brush.
Apply in three (3) coats. The first time over, put on suffi cient material to cover the surface completely, using material as thin as possible and grinding it thoroughly into the base coat. Allow this to draw a few moments to avoid blister ing.
The second time over, lay the material on perfectly level.
The third time, make the material as thin as can be handled on the hawk and fill in cat faces and imperfections. After it has drawn a few moments, trowel to a smooth surface, applying water with a damp brush. Do not drench with water (drench ing will kill the face of the material), Work top and bottom
(33d) Texture Finish--Apply in two (2) coats. First apply a thin coat, grinding this into base, thoroughly covering the surface, and allow to draw a few moments. The second time over, lav the material on perfectly level, working it into the desired texture.
Proper drying conditions must be maintained in order to protect the color. During the late fall, winter and early spring months, the slow-drying periods of the year, artificial heat and proper ventilation must be arranged for. Failure to provide this protection may result in color difficulties.
Note: The Ukited States Gypsum Company will furnish on application a Special Bulletin covering the execution of textured finishes.
(33e) Tile or Masonry Effects--Markoff with a straight edge while the material is "green"--preferably from 4 to 5 hours after application. Units shall be rectangular and joints shall be clean cut and even.
(34) Application of Keene's Cement Finish
of the wall at the same time to avoid joinings.
(31c) Red Top Trowel Finish or Lime and Gauging Plaster--
(34a) Location--The following shall receive Keene's Cement Finish:
Note: List and locate either in schedules on plans or here.
Apply over dry walls, using more water if the walls arebone dry. Scratch in a thin coat, then go over a second time filling imperfections and cat faces. Trowel to a smooth finish applying water with a damp brush. Troweling should be com pleted before the finish has set. In cold, damp weather, provide heat and ventilation until the finish is dry.
(32) Application of Sand Float Finish
(32a) Location--The following shall receive sand float finish:
(34b) General--
Note: Specify same as (31c) in opposite column.
(34c) Marble Panels--Keene's Cement wainscots shall be divided into even vertical panels with V-joints while the material is `'green"--preferably from 4 to 5 hours after application. First rake out plaster base at joints for a depth of Vi and Vi in. wide, laid to a straightedge, plumb and true--clean of loose particles. Apply Keene's Cement as above and form clean cut, even vertical V-joints at panel divisions.
(34d) Tile Effects--
Note: List and locate either in schedules on plans or here.
Note: Specify same as Oriental Interior--Tile Effect.
(32b) Prepared Sand Float Finish or Cement Plaster Sanded--
(34e) Polished Surfaces--After the cement is dry, polish with a cloth to a highly polished surface.
Apply sand float finish after base coat has set firm and
bard, but while still green--within twelve hours after base (35) Ornamental Work
coat has been applied. Lay on with a trowel and then use a (cork) (carpet) or
(felt) float, working the material to a true, even surface, free from float marks and cat faces.
Note: Cork float preferred.
.Use as little water as possible while working, so as to avoid killing the surface. Use damp brush only. Do not attempt to Work after the material begins to or has set.
Work top and bottom of the wall at the same time to a*oid joinings.
(33) Application of Oriental Interior (Colored Fin" ish Coat)
(33?) Location--The following shall receive Oriental In; r Finish:
List and locate either in schedules on plans or
,no (33b) General--Brown coat should be broomed or left ** Vndvr darby to insure a good bond. Remove all loose or
' particles from base coat which may show through -coat.
coat must be set firm and hard before the appli0 j Oriental Interior. On all types of masonry eonslrne-
**~'ou hi Sypsum tile, clay tile, etc., the Base coat must he ~ ^jUmy dry. On other types of lathing base, such as plaster
^tertheK,,. or metal lath. Oriental Interior may be applied * ~too p "ase coat >s 50% dry. If the suction in the base coat
i t0 Permit case of application, wet down lightlv
^tformly with clean water.
'
tIo*'--** cut*`nB irce--oenutrraannit angles, use a xtrroowweil wimth e<digges `jjj a curve approximately the circumference of a dime,
killinir * wa,er as possible while working, so as to " me surface. Use damp brush only. Do not at-
rk ,rk mater'al after it begins to or has set. P and bottom of the wall at the same time to avoid
^ eoaL^at ?'n*sb--Apply in two (2) coats. First apply
?J|lnS (hi? into base, thoroughly covering the
the m 0VV -tO ^raw a fc*w moments. The second time
cr (Mm"`o' on Pcrt"ect'.v level and then use a (cork)
"tfree f
hoat, working the material to a true, even
rorn float marks and rat faces
(35a) Location--The following rooms require ornamental plaster in accordance with details.
Note: List and locate either in schedules on plans or here.
(35b) Models--
(3Sbl) .All ornamental work shall be executed from models.
(35b2) Models shall he furnished at the contractor's ex pense for all ornamental work. These shall be made by a skilled modeler (selected) (approved) by the architect, preferably in (name place) so that they may be under the direct supervision of the architect while being prepared. Models must be submitted for approval while in the clay.
(35b3) The contractor shall allow the sum of (specify) to cover the cost of models prepared under the direction of the architects, delivered f.o.b. cars (specify).
(35b4) The owner will furnish, without cost to the con tractor, models prepared under the direction of the architect, delivered f.o.b. cars (specify).
(35c) General--
(35cl) All curved work shall he (run) or (cast) to true radial lines.
(35c2) Leave all ornamental plaster work in perfect condi tion for decorating, true arid smooth, with surfaces and inter sections rubbed down with fine sandpaper, it necessary..-
(35d) Run Work--All run work shall be executed in gauged Moulding Plaster.
Furnish clean cut, accurate templates made in strict accord ance with the architect's (full sice) details.
Run all mouldings straight and true with perfect arrises and miters.
(35e) Cast Work--All cast work shall be executed in Moulding Plaster.
Ornamental work shall be cast hollow or solid as best suited to conditions, thoroughly strengthened with fiber and braced where necessary.
All cast work shall be set accurately--true, plumb and straight.
If necessary, members shall be substantially fastened around furring: where nails are used, they shall be gal vanized.
PACE 20
8B006 1110
United States Gypsum U)mpan;
ORIENTAL EXTERIOR STUCCO
(Base Coats said Colored Finish Coat)
Description
Oriental Exterior Stucco is a completely factory-mixed ex terior stucco material of the highest quality. The finish coat is scientifically colored in a wide range of tints. It is the product of careful and thorough investigation and research by the United States Gypsum Company.
The chief limitation of stucco heretofore has been the dif ficulty of producing the desired texture and color to harmonize with the architectural design when the color has to be mixed in on the job, or of matching a certain color when the batches are mixed at different times or under different condi tions.
Oriental Exterior Stucco is scientifically compounded and is water-resistive, non-staining, plastic, easy to apply, and permanent. Its use eliminates much of the uncertainty and deiects inherent in both quality and appearance in the usual job-mixed stucco work.
Bases--Oriental Exterior Stucco may be applied over steel fabric, metal lath, wire lath, tile, brick or concrete. It is particularly adapted to use over Gyplap wall construction (see page 31). It is also adaptable for overcoating old cement stucco walls, masonry surfaces and walls of frame buildings.
Oriental Exterior Stucco contains no ingredient that will in any way weaken or corrode steel reinforcement.
Base Coat--Oriental Exterior Stucco Base Coat is a spe cially prepared, factory-mixed, permanent, water-resistive base for Oriental Exterior Stucco Finish, with the correct propor tion of uniformly graded, selected sand, and other ingredients added to make it plastic.
Factory mixing prevents oversanding or improper propor tioning of other ingredients on the job. Its uniformity assures perfect joinings of various mixes that will not show through the delicate coloring of the finish coat.
Being made ready for use by the addition of water only, it is economical of time and labor and assures a base of uni form suction and strength.
Finish Coat--Oriental Exterior Stucco Finish is mixed with mineral colors and prepared ingredients that make it water-resistive. The formula used is based upon methods used in producing the famous Old World stuccoes and one success fully used in America for 20 years.
Oriental Exterior Stucco Finish is furnished in white and eleven standard colors. AH ingredients, including the mineral colors, are weighed and the charge thoroughly machine mixed.
Water only needs to be added at the job. A uniform color and correct mixture are thus assured, entirely eliminating the un avoidable variations which occur when stucco is hand-mixed on the job.
Characteristics
Oriental Exterior Finish sets slowly enough to permit proper finishing, thus avoiding unsightly streaks or shading.
Proper manipulation by the workman will produce in Ori ental Exterior Stucco the beautiful texture and color effects that mark the finest of both Old World and modern stucco work. Besides the period textures, it is easy to achieve the smooth trowel, stipple, sponge, rough cast or spatter-dash finishes.
Oriental Stucco Finish increases in hardness, strength and water resistive qualities with age.
Use
Use for base and finish coats of exterior white or colored stucco of the highest quality.
iVote: Oriental Exterior Stucco Finish imiy be applied over standard Portland cement base coats.
Package
Oriental Exterior Base Coat is shipped in SO-Ib. paper bags, and Oriental Exterior Finish Coat is shipped in 100-lb. paper bags. Order Finish Coat by the number on color cards or samples.
Covering Capacity
Note: See ''Cohering Capacity," page 11.
Base Coat--The approximate covering capacity of one ton of Oriental Exterior Stucco Base Coat (scratch and brown coats) on the basis of the average job, is as follows:
Plastering surface
Brick and day tile
Sq. yd. per ton 20 to 23 .
Metal lath
20 to 22
Wire fabric
Cement and cinder tile
Concrete
20 to 25 20 to 22 20 to 25
Finish Coat--One ton of Oriental Exterior Stucco Finish, not to exceed Vi in. in thickness, will cover from ISO to 200 sq. yds., depending on the texture selected.
ORIENTAL EXTERIOR STUCCO--SPECIFICATIONS
Note: Notes are explanatory or advisory only and should not be included m the specifications.
(1) Work Included
The following surfaces shall be finished with Oriental Ex terior Stucco:
Note: Here list and locate all work included under this contract, together with the description of texture and color selected. If more than one texture or color is used on the :cork, list, locate and describe separately.
( 2 ) Examination
This contractor shall examine all base surfaces to receive stucco and shall report to the architect in writing any defects which will detrimentally affect the work under this contract. Commencement of work under this contract, without such notice, will be construed as acceptance of the base surfaces, and full responsibility for the perfect final condition of the finished work.
(4) General
All materials shall be States Gypsum Company. skilled workmen.
as manufactured by the United AH work shall be performed by
(5) Materials
(5a) Red Top Expanded Metal Stucco Mesh--l'.i-in. mesh, painted: weight f 1.8) (S.6) lb. per sq. yd. Nails shall be
special self-furring nails. (5b) Woven Wire--Electrically welded, 2-in. mesh fab
ric of No. 14 gauge cold drawn steel wire, thoroughly galvanized and crimped for self-furring. Nails shall be special No. 10V
gauge, 1% in. long.
---
Note: Furnished 48 in. -wide, 112% ft- long containing 50
sq. yds., especially for use over Gyplap sheathing See page SI. It is equally adaptable for use over toood[ sheath.
Note: Select cither expanded metal or ile*!*eir*~,t)csh for
frame construction as desired,
... lrVTli"rUiE -
(5c) Base Coat--Oriental
(3) Sample Panels
The contractor shall furnish on the site, where directed, three (3) sample panels one (1) square yard in area for the approval of the architect. Panels shall be executed on the base specified and in accordance with the architect's selection of tex tures and colors. The stucco work shall be finished in accord ance with the approved panel or panels.
Lathing
tote: Include only for
6a) Expanded Metal-
uds. Secure with facturer's direction*.>P
PAGE 21
tfdrSytal across
` *?th the Wuds.
08006 1121
B2466
United States Gypsum Company
Lap pieces of expanded metal 1 in. Carry metal around all corners to the first support. Thoroughly secure the metal at
all openings. (6b) Woven Wire--Apply reinforcement across the
studs with the crimps against the (Gyplap) (Sheathing). Nails 0 in. apart on studs. Lay pieces of reinforcement at all sides and ends so that cross-wires lap I in. Vertical joints shall be broken and shall come at supports. Carry reinforcement around all corners to the first support. An extra piece of reinforcement shall be nailed diagonally across corners of all openings.
(7) Mixing and Application of Stucco
(7a) General-- (1) Use a clean, tight mixing box, about 3V2X7 ft., raised
about 4 in. at one end. .Mix with a hoe. Clean the mixing box
after each gauging.
..
(2) Use only clean water, free from alkali and impurities;
keep tools clean. Do not rinse tools in gauging water.
(3) Do not mix more material than can be applied in about
one h(4o)ur.Do not mix one gauging with another and do not
retemper stucco after it lias commenced to set. (5) Do not apply during freezing, cold or wet weather, nor
when rainstorms threaten. Note: Freezing will cause disintegration as well as color
difficulty. Slow or sluggish drying or a rainstorm before hardening takes place, generally results in cloudy effects and color distortion. Careful treatment of this phase of stucco work is the greatest guarantee of uniformity in color. The material should not be applied to greasy surfaces. Integral waterproofing or anti-freeze solutions should not be used.
(6) Keep stucco in a dry place. Do not store on the bare ground.
(7b) Base Coats--Add only clean water to Oriental Exte rior Stucco Base Coat and mix to the proper consistency. Apply in two coats. The first coat shall be not less than bi in. thick, scratched. After the first or scratch coat has thoroughly set but not dried, apply the second coat not less than % in. thick properly rodded and floated to a true plane. Rake or thoroughly scratch each coat to provide a key for the succeeding coat.
(7c) Finish Coat--Add only clean water to Oriental Ex terior Stucco Finish and mix to the proper consistency. Allow finish coat to soak from 20 to 30 minutes. After the second base coat is completely dry, spray wall sufficiently to cut suction and apply finish coat not less than % in. or more than V* in. thick, as required for the finish selected.
The finish shall be: Note: Here specify or describe the finish selected. V.S.G. Bulletin OS-3 describes in detail the methods used to obtain various texttires.
SHEETROCK--THE FIREPROOF WALLBOARD
Description
Advantages
Sheetrock is a fireproof wallboard. It is made
Fireproof--Does not burn or readily trans
of gypsum, moulded while in a plastic condition
mit heat. It interposes a continuous fireproof sheet
between two sheets of tough protective paper. In
of substantial thickness over the wood frame con
the finished product the gypsum has recrystallized
struction.
and the board is strong, lasting, tough, durable ami
Permanent--Does not disintegrate.
slightly flexible. The long edges are reinforced and
No Expansion or Contraction--Does not warp,
protected by the same material with which the board
shrink or crack, because it is unaffected by climatic
is sheathed. These patented edges are square, uni
conditions.
form and true. The Sheetrock Reinforced Joint System described on next page provides a uniform, strong, jointless surface ideal for any finish.
The following are recent developments in the
Sew Improved Sheetrock.
G.S.G. Patented Re in iorced Edges Pro vide Extra Nailing Strength and Insure
Tight, Flush Joints
Substantia] Thickness--% in., almost twice as thick as ordinary fiber wallboard.
Strong Close Longitudinal Joints--The boards fit close and even. The tough paper covering of Sheetrock is folded square over the longitudinal
A New Surface--New Improved Sheetrock has a close- edges, forming a patented feature which insures an extra
grained, highly calendered surface of ivory color. It is tough strong nailing edge and tight, flush joints. When finished with
and highly resistant to scuffing and abrasion. Light colored Sheetrock Reinforced Joint System (see bottom of page 29),
paints retain their original freshness and clarity. All paints the joints are permanently hidden and are not apparent even
spread farther.
under wallpaper.
The Improved Core--The new cellular structure makes
Sound and Heat Insulation--Its greater thickness and
New Improved Sheetrock more insulating. It also increases permanently tight joints increase its insulating qualities mate
flexibility, reducing the chance of breakage in transport, han rially over those of ordinary wallboard.
dling and application. The gypsum at the ends is specially
It is a non-conductor of sound to a surprising degree.
hardened.
Easy to Install--It is sufficiently light in weight for easy,
Improved Nailing Edges--Nailing edges on the New rapid handling. The tough sheets can be sawed and nailed
Improved Sheetrock are square and uniformly thick. The like lumber.
Paper enveloping the core has been chamfered so that the
reinforced edges are of precisely the same thickness as the rest Use
f the board, thus eliminating bowing in the piles. Panels join
Because Sheetrock possesses so many high grade, practical
-Frmly and smoothly.
features, it has a correspondingly wide field of usefulness.
New Marking--On the back of each panel will be found
Use for walls and ceilings in buildings of all types; build
? distinctive marking. This new marking will he recognized ing new rooms in old buildings; lining garages and attics;
^mediately as the sign of the New Improved Sheetrock.
fireproofing over heating plants; factory dry rooms: exhibi
Sizes
tion booths; walls and ceilings of remodeling work. It is particularly adapted to office partition work in existing build
4 .Sheetrock is made
thick; 32 and 48 in. wide and ings. since it eliminates the time and dirt of plastering.
Lf ** Sli, 9 and 10 ft. long. The widths fit stand-
Sheetrock walls, particularly when finished with Metal "A"
,.16-in. centering of studding and joists and the lengths Joint System or Sheetrock Reinforced Joint System, take all
adapt it to average ceiling heights.
types of painting and decorating, including wall paper.
Sheetrock is also made V4 in. thick and 6, 7, 8, 9 and 10
Textonc, the Plastic Paint described on page 37, is a par
,W- Be sure to specify the thickness desired.
ticularly desirable decorative medium for Sheetrock.
SHEETROCK REINFORCED JOINT SYSTEMS
United States Gypsum Company has developed two ~?ltlT|i of joint reinforcement, which add permanent joint
to the other advantages of Sheetrock. The join-
i[ T11.
boards are "laced" by reinforcing (either the
- ***! V'V' System or the Fabric System) embedded in
__=_- j . joint cement of unusual strength and adhesiveness.
* ,s applied as illustrated on page 23. This assures
;^C f 90ncealment of board joinings and lessens the possi-
Vf'nt cracLs showing through the decoration.
'lc':al "A" Svstem of reinforcing consists of a per-
tape packed in a box containing 230 lin. ft. IT*
" ts -~ ^s. 07 joint cement which is sufficient to treat
Fah
s9- lt' <,t*
surface.
r`c System of reinforcing consists of a specially
woven and processed cloth fabric, packed as above described for Metal "A" System, except the bag contains 10 lbs. of cement.
The Metal "A" System is somewhat more expensive, hut
is preferable. Select the system desired. Sheetrock Finisher is a specially prepared material, far
superior to so-called joint fillers, with none of the disadvantages of the old type of plaster filler. When mixed with water, Sheetrock Finisher forms a cement, which is easily, quickly and economically applied with a semifiexibie scraping knife. It is used to conceal joints, spot nailheads and repair surface abra sions. Supplied in 5- 10- and 25-lb. packages. .5 lb. should finish joints and cover nailheads for 500 sq. ft. of Sheelrock.
PAGE 22
C`>nHnutC "i next page
09006 1112
United States Gypsum Company
APPLICATION OF SHEETROCK REINFORCED JOINT SYSTEM
B2467
Sheetrock Joint Be* fore Reinforcing
Buttering"--Working the Cement Into the Joint
Putting Metal "A" or Cloth Fabric Reinforcing in Place
Forcing Cement Through Metal "A" or Fabric and Lev*
eling Surface
SHEETROCK SPECIFICATION--SHORT FORM
( 1 ) Work Included
Note: List and locate all 'walls and ceilings la be covered with Sheetrock.
(2 ) Framing
All studding and joists shall he spaced 16 in. on center. Provide 2x4-in. headers on ceilings to take all end joints of Sheetrock and where required to form nailing base for wood beams, cornices, etc. Cut in 2x4-in. headers on walls to form substantial nailing for baseboards, wainscot caps and similar interior woodwork trim.
(3b) Nails--3d cement coated common nails (flat head) l's in. long.
Note: On buildings of two or more stories 'with u floor above Sheetrock ceiling, use -Id nails.
(4) Application
Apply Sheetrock direct to framing as per directions of the United States Gypsum Company, manufacturer.
Note: Specify joint system desired. Do not use plaster paris or ordinary joint tiller.
(3) Materials
(3a) Wallboard--"i-in. Sheetrock as manufactured by the United States Gypsum Company.
(5) Decoration
Note: Specify type of decoration, to be applied aecording to the directions of the manufacturer of Sheetrock.
SHEETROCK TILE BOARD
Description
Sheetrock Tile Board is a fireproof, gypsum wallboard made to obtain conveniently and at low cost, beautiful tiled-wall effects. ..... ^Sheetrock . Tile Board is a perfected product mat makes possible lacquered and enameled surfaces ff>at resemble the best ceramic tile in any shade of color desired, thus enabling the decorator to obtain complete color harmony.
After Sheetrock .Tile Board has been erected and decorated, it can be washed clean when soiled.
The surfacing of Sheetrock Tile Board is of heavy nber. which has a distinctive cream color, especially adapiecl tor decorating.
Sizes
. Sheetrock Tile Board is made in panels '!* in. thick, -JS Jn. wide and 6. 7. S. 9 and 10 ft. long. The tile im
pressions are
in., a standard size for built-in
s- There is a selvage or trimming edge on each
end outside the tile pattern. The panels are
packed two in a bundle, with the tile face inside and edges reinforced.
Advantages Because it is made from gypsum. Sheetrock Tile
Board does not burn. Neither does it warp or buckle, nor does it harbor vermin, and, though it is made from gypsum rock, it is light enough for convenient erection and can be nailed, sawed and fitted with the ease of wood.
The material has all the advantages inherent in Sheetrock. See page 22.
Use Use for tiled-wall effect in bathrooms, kitchens,
lavatories, lunchrooms, dairies, (lectors' offices, restau rants. delicatessens and barber shops.
Erection and Decorating Complete directions for erection and decorating of
Sheetrock Tile Board are on the hack of each panel.
GYPLAP--FIREPROOF SHEATHING
tption
is a solid sheet nf gypsum encased in a tough fibrous
7o* the outer surface of which is moisiureproof. Its
fram' an^ 5trt'ngth make it an ideal material for sheathing c itructures under siding, stucco and brick veneer.
Gyp| 1
excellent fire stop between tutors.
UaP has the U.S.G. patented reinforced folded edge.
maximum strength. The largo units, spanning
in,, s;nds. have been found hy tests to support the
Tj.,1,l<ri.'r 'h'lti does wood sheathing laid horizontally.
P .ms .1,! m.'erlocking joint. ar.d. as the sheets do -r t
warp and -eparatc at the joints, the wall is wind-light. The use of building paper is unnecessary.
The material saws and nails as easily as lumber, and. because of the rapidity with which the large units can be applied and the elimination of building paper, this fireproof sheathing costs but little, if any. more than wood sheathing in
the completed job.
Sizes
Gvplap is 'it in. thick, 24 h ns.
wide. 0 ft. 8 in. and 8 ft.
PAGE 23
I I I 9C0UH