Document oe7O377X0Bnjmaa3bM9ZxDkK7

P. O- Box 9217 FfL* PHONE 512 8 84-8863 SOUTHWESTERN REFINING COMPANY, INC. CORPUS CHRISTI, TEXAS 78408 February 5, 1986 Bill Stewart, P.E. Executive Director, TACB 6330 Highway 290 East Austin, Texas 78723 Dear Mr. Stewart: My letter to you, dated May 31, 1985, stated that Southwestern Refining Co. Inc. did not anticipate any removal of asbestos for the year 1986. This has changed; whereby, please acknowledge this letter and enclosed proposal as being in compliance with 40 CFR 61-145/146 Standard for Demolition and Renovation of Asbestos material. Thorpe Insulation Company has been chosen to perform this job for us and enclosed Is a copy of their detailed procedure. Should there be any questions, please call. Sincerely SOUTHWESTERN REEHJING CO y INC. Vr . TWT__a__y1 lIo-n TLJitto__n__ Manager of Safety/Hygiene am cc/enc: W. T. Palmer, P.E. Regional Director A.L. Cock, Region 5 5602 Old Brownsville Road Corpus Christ!, Texas 78415 SWRf/Asbestos 6439 1H 041799 THORPE INSULATION COMPANY o i r . - r : : February 3, 1986 r D J S r '? I A i N 5 U L r ! Texas Air Control Board 5602 Old Brownsville Road Corpus Christi, Texas 78415 Attention: Ms. Debbie Stine Subject: ASBESTOS INSULATION REMOVAL PROCEDURES Southwestern Refining Company Cat Cracker Unit Corpus Christi, Texas Please be notified of our intent to perform asbestos removal at the above subject project, pursuant to Title 40 Code Federal Regulations 61.146. We are familiar with the latest OSHA and EPA Regulations and Standards for asbestos removal and we take all the necessary steps required to perform this type of work. In accordance with the above regulations, please see the Notifi cation Requirements outlined below: A. ) The owner of the facility is Kerr-McGee Corporation - 1700 Nueces Bay Boulevard - Corpus Christi, Texas. B. ) The materials containing asbestos shall be removed from the reactor and stripper and reactor skirt (outside only) on the Cat Cracker Unit. The Cat Cracker is approximately 9.5*0 x 30' . The facility is approximately 32 years old. C. ) The approximate amount of friable asbestos material present is 34 cubic yards. D. ) The location of the facility is Cat Cracker Unit at Southwestern Refining Company - 1700 Nueces Bay Boulevard - ' Corpus Christi, Texas. E. ) The asbestos removal on the above subject project shall commence on or about February 21, 1986 and the completion date shall be on or about February 23, 1986. SWRf/Asbestos 6440 1H 041800 February 3, 1986 Page -2- F. ) In addition to our own established company asbestos removal procedures, we shall be following applicable Federal Regulations 29CFR1910.1001 - ASBESTOS STANDARDS; 29CFR1910-134 - RESPIRATORY PROTECTION; 40CFR61 SUBPART A and 40CFR61 SUBPART M. G. ) The work area shall be enclosed with a layer of .6 mil clear plastic stretched over a scaffold frame work. We will be using a HEPA Air Filteration to create a negative pressure within the work enclosure. Additionally, we shall use the HEPA Vacuum for clean up along with our standard cleanup procedures. The area and materials shall be sprayed with water containing a wetting agent. While materials being removed are still wet, they will be placed in properly labeled .6 mil plastic bags. Our employees shall also wear an approved Type C Fresh Air Mask and disposable hoods, boot covers, gloves and coveralls during this work. They will be required to shower before lunch and before leaving the jobsite. During the jobs progress, personal and environmental samplings shall be performed. H.) The bags of friable asbestos waste materials shall be disposed of at Waste Disposal, Inc. - P. 0. Box 1095 - Sinton, Texas. We hope this will provide you with a thorough explanation of our Asbestos Removal Procedures than previously submitted. SWRf/Asbestos 6441 1H 041801 February 3, 1986 Page -3- If you should have any questions, please do not hesitate to contact us. THORPE INSULATION COMPANY W. R. Moake Vice President/Operations Manager WRM:sgs cc: file copy: Kerr-McGee Corporation 1700 Nueces Bay Boulevard Corpus Christi, Texas 78407 Attention: Mr. Waylon Litton J. T. Thorpe Company P. 0. Box 33399 Houston, Texas 77233 Attention: Mr. Gregg Roberts SWRf/Asbestos 6442 1H 041802 SOUTHWESTERN REFINING COMPANY, INC. CORPUS CH R I STI, TEX AS 78408 May 31, 1985 Bill Stewart, P.E. Executive Director, TACB 6330 Highway 290 East Austin, Texas 78723 Dear Mr. Stewart: To comply with TACB regulations. Southwestern Refining Co., Inc. will continue to follow the AO CFR 61-145 Standard for Demolition and Renovation of asbestos material. We do not anticipate any removal of asbestos for the remainder of this year 1985 or 1986. Should any future plans fall within the standard guidelines, we will inform your office and the local office here in Corpus Christi. Sincerely, am xc: W. T. Palmer, P.E. Regional Director A. L. Cock Region 5 5602 Old Brownsville Road Corpus Christi, texas bxc: Burnell Brown-FYI 78415 V. Waylon Litton Manager of Safety SWRf/Asbestos 6443 1H 041803 JOHN L. BLAIR Chairman CHARLES R. JAYNES Vice Chairman ALLEN ELI BELL Executive Director March 12, 1986 6330 HWY. 290 EAST AUSTIN, TEXAS 78723 512/451-5711 VITTORIO K. ARGENTO, P. E. BOB G. BAILEY FRED HARTMAN 0. JACK KILIAN, M. . OTTO R. KUNZE, Ph. D.. P. E. R. HAL MOORMAN HUBERT OXFORD, III Air Quality Control Region 5 5602 Old Brownsville Road Corpus Christi, Texas 78415 512/289-1696 Mr. V. Waylon Litton Manager of Safety/Hygiene SOUTHWESTERN REFINING COMPANY, INC. Post Office Box 9217 Corpus Christi, Texas 78408-9217 Re: NESHAPS Asbestos Notification Dear Mr. Litton: This is in regard to your letter dated February 5, 1986 regarding asbestos removal from your company's Cat Cracker Unit. This letter acknowledges receipt of your letter and the methods described in your letter. Should you have any questions, please do not hesitate to call Ms. Deborah Stine at 512/289-1696. Sincerely* W. T. Palmer, P.E. Regional Director SWRf/Asbestos 6444 1H 041804 Celebrating 150 Years of Texas Independence 1836 - 1986 U. S. Department of Labor Corpus Christi Area Office Government Plaza 400 Mann Street, Room 300 Corpus Christi, TX 78401 512-888-3257 Occupational Safety and Health Administration Reply to the Attention of: RLMH: keg February 12, 1986 Southwestern Refining Co. P.O. Box 9217 Corpus Christi, TX 78408 Attn: Mr. Waylon Litton, Safety Manager Dear Mr. Litton: The Occupational Safety and Health Administration is currently conducting a National Emphasis Program for programmed health inspections of estab lishments where asbestos is used, stored or processed. Also included in this National Emphasis Program are any sites involving asbestos demolition and removal activities. (OSHA Instruction CPL 2.60B) Currently OSHA receives notices regarding the asbestos demolition/removal activities from the Environmental Protection Agency and the Texas Air Control Board, but in an effort to improve its response time OSHA re spectfully requests that your company notify us of any asbestos demo lition or removal activities on your site. OSHA would like for you to also inform your asbestos demolition/removal contractors of the assistance available from our local office. The local OSHA Office functioning as a full service office resource center will gladly meet with any asbestos demolition/removal contractors prior to their scheduled work. The 29 CFR 1910.1001 Asbestos Standard will be fully discussed including viewing of a video tape and/or slides. Also in this session will be a discussion of respiratory protection, other PPE and specific monitoring requirements. For notification purposes the address of our office is as follows: U.S. Department of Labor, OSHA Government Plaza 400 Mann Street, Room 300 Corpus Christi, TX 78401 (512) 888-3257 Together we can make the workplace safer and more healthful. Sincerely SWRf/Asbestos 6445 R. U. m-lKiS HUWTiSK Area Director 1H 041805