Document oe6xM4mqyLmoKp7JO2q4LYkzD

INTEROFFICE CORRESPONDENCE ..a To Z. .. Tellenbeck - Beaumont Attn: U. ?. Pepper date c. c. September 12, 197^ " 'fJS . _ ?. Medlin - 3eaumont 10 D. 2. Miller - New York H. Murray, Jr. - Mew York . J. Selfridge - New York Attn: /*. T. Oregg ...... w-.i .o. . H. A. Sinclaire, M.D. - !Tew York Attn: 2. X. Daniels INDUSTRIAL HYGIBNE SURVEY., - :m-5 3-7^ '" Asbestos Insulation Removal Hydrogen Unit Beaumont Refinery Beaumont, Texas August 1, 197k_________________ __ .Attached you will find an industrial hygiene surrey conducted at the Beaumont Refinery which was conducted to determine airborne asbestos concentrations during the insulation removal process on a reactor vessel, performed by R. L. Witzke on August 1, 197k. The results of sampling indicated that asbestos fiber concentrations- were below the current O.S.H.A. Standard of 5 fibers greater than 5 microns per cubic centimeter. Although all samples were below 5 fibers.- some exceeded 2 fibers oer cubic: ogr.r.^.pr.py limit which will become effective in 1976. The data presented in this report represents the most adverse conditions that could be expected. There were no wet control methods used to reduce fiber concentrations. Therefore, to insure work area asbestos fiber con centrations comply with the 1976 limit of 2 fibers, a wet control method should be used as required to reduce airborne asbestos fiber concentrations. If further questions arise or further assistance be necessary, please contact this office or Mr. Witzke's in Beaumont, Texas. RLW: rm Attachment Regional Medical Director 05545 447316 WESTERN REGION MEDICAL DEPARTMENT DALLAS, TEXAS WR-53-7^ August: 1, 19T1* Industrial Hygiene Survey WR-53-7U Asbestos Insulation Removal Hydrogen Unit North American Division Beaumont Refinery Beaumont, Texas 05546 447317 An industrial hygiene survey vas requested by Paul Pepper, Complex Plano Manager, oo determine airborne fiber concentrations of asbestos emitted during the removal of asbestos bearing insulation. 'This study vas performed by the undersigned on August 1, 1974 as part of the Medical Department's continuing surveillance of in-plant occupational health conditions in the Mobil North American Division facilities, to insure compliance with safety and health standards of the Occupa tional Safety and Health Act of 1970. . ::. SUMMARY The results of samples collected and analyzed for airborne concentrations of asbestos fibers greater than five microns in length, indicate that the levels vere found below the current 0.5.5.A. Standard limit of five fibers per cubic centimeter, as presented in 'Table I; although some of the breathing cone samples collected vere found above the O.3.H.A. limit, which becomes effective in 1976, of two fibers per cubic centimeter. A.t a distance of 25 feet downwind from the work area, with a 10 mile per hour vina, fiber concentrations were found 50 times below the current O.S.H.A. limit of five fibers per centimeter. . III. RECOMMENDATIONS Based on the results of this survey, the eight-hour time-weighted average exposure of workers handling asbestos containing material vere below current standards. To hazardous situation existed during this sampling episode. Even though the data represents compliance with current standards, airborne concentrations did exceed the 1976 O.S.H.A. limits for an eight-hour time- weighted exposure. The present work policy of the refinery provides adequate personal protection to employees working in asbestos areas. All asbestos bearing insulation should be wetted to reduce air fiber concentration. The distance to be designated as a dusty area will depend on the wind :;pcau mm height of the insulation being removed above ground. In this study, 25 feet was more than enough. IV. INDUSTRIAL HYGIENE SAMPLING In worker breathing zones end the general work area, air samples were collected to determine worker exposure levels to airborne asbestos dust concentrations. Air vas drawn through an open-faced Millipore, type AA, 37 millimeter filter, at an airflow rate of 2.00 liters per minute by means of a small battery-operated pump (Mine Safety Appliance Company, Model G). Worker breathing zone samnLcn were collected by placing the pump on the worker's belt and connecting the 05547 AA73A8 sampling head to the worker's collar. 3amples were then sent to a private analytical laboratory where they were analyzed for fibers greater than five microns in length and counted. A fiber is classified as having a ratio of 3 to 1 between its length and fiber diameter. V. REPORT and discussion An industrial hygiene survey was performed during June of 197^ {VR-47-71) regarding the. asbestos fiber concentrations emitted during pipe insulation removal. Again insulation was removed without wet control methods. The results of that survey showed all samples to be below two fibers per cubic centimeter. A study at the Paulsboro Refinery showed no fibers were detected by sampling when a wet control method was used to reduce airborne dust concentrations. There were eight workers, four pipe insulators and four laborers assigned to strip block-type insulation from the Xethanator Reactor vessel wails. The vessel has a surface area of around 730 square feet of which 300 square feet was removed during the sampling duration. Insulation on upper portion of this vertical drum was removed. Insulators would loosen the insulation and hand it to laborers also located on the vessel scaffolding. The insulation was placed into burlap bags which had a polyethylene bag lining on the inside. When the bag was full, it would be lowered to the ground where a worker would shake the bag down, tie, and place a "Caution" tag on the bag. The material was then removed by truck for disposal. A restrictive barrier was located at a distance of 20 feet around the vessel. The wind was blowing from the north at 10 miles per hour, which was sufficient to blow dust particles outside the perimeter of the restricted area. Asbestos samples collected 25 feet from the vessel showed very low asbestos fibers were among the dust particles present at that distance. RLW:rm Assistant Regional Industrial Hygienist THESE RESULTS HAVE TVFHTW DISCUSSED WITH THE PLANT MANAGER BEP0HE LEAVING THE PLANT. 05543 447319 u 2 3 a o > <cu -aO aj Q0) O O etvoa o p co 447320 P ia n t: N o rth A m erican D iv is io n , the aumon R e fin e ry ft. L. WiLoke