Document oe4wk8q0p8XjRqbxOmD9zGxv3

8 Is no question that recovery can be effectively increased In every [/ major industry we now serve. If Monsanto does not assume or . lnitiat^ this program for our own fluids it will be done by another ; company . 'i -' ' In the case of synthetic fluids, perhaps more so than other chemicals, the customer can, through improved or modified housekeeping procedures, recover synthetic fluids and most do net have to install a waste treatment facility. Each of our key irdustries is discussed separately with regard to feasibility of synthetic fluids recovery. Diecasting Y/aste treatment facilities are rare in this industry. The only area where treatment is found is for cutting oils and plating . chemicals, where the plant machines and paints or plates the diecast part. This market represents about 30% of the 1000 diecasting accounts in the United States, according to Detrex^Incorporated, the major supplier of degreasing chemicals and systems. ' The major products consumed by the diecaster are dielubes (water or .. solvent base), lubricating oil arid greases, cleaning solvent and hydraulic fluids. Hydraulic fluid (Pydraul) usage is substantial at 20-30% of total fluids consumed in the plant, with larger die- cast plants,!.e. ,JohnsonMotors using the smaller ratio of FR fluid to total chemicals. Although the amount of other products consumed .. . . is substantial there appears to be limited Intermixing with the waste Pydraul. Dielubes are vaporized when .contacted with the hot diecast part and lubricating oils and greases are - In machining DSW 297315 STLCOPCB4067225 ;9 outside or adjacent to the immediate diecasting area. Pydraul usage escapes into four separate sources in the diecast plant.' These sources include bulk wasi e (major line breaks and .> spills) adhered to diecast parts, water effluent and through floor dry absorbent material. A diecaster's -"water effluent" is an open trench network in the plant floor that carries cooling water to the diecast machine dies. This water is normally recirculated to a . cooling tower with limited overflow to sewer. Table I displays results found by personal contacts at 9 different diecasting accounts. In all cases either the floor absorbent or the water effluent represented 80-100j of the Pydraul consumed at the account. Those plants reporting no Pydraul escaping into the water effluent have closed cooling water circulating lines. The other accounts reporting escape to water have open accesses where liquids flow freely from the diecasting area directly into the water. In th*e case of Johnson Motors the machines are cleaned regularly with solvent and everything is flushed into the troughs. At Johnson Motors a total of 85-90; of their Pydraul consumption escapes directly into the water stream. Based on the above results and our knowledge of the diecasting market, several points are.important: . l) Of the estimated 400-500 diecasting shops using synthetic inw v.-.f; v-r >. v, sTsT'-dhly^a^strair1 percentage: 'have open access trenches where Fydraul contacts water directly. Dsw 297316 STLCOPCB4067226 10 Although a small percentage, however, these accounts are the larger dlecasters (Johnson Motors, Central Foundry, Lestee Castings, etc.)* > 2) The diecaster is concerned about pollution and all are anxious to maximize cost savings. We must expect that the larger volume of fluid escaping into the stream will require the customer to provide adequate sumps/ponds or virtually close off access to his water stream. The * ; logical choice for most is closing off access to insure ' compete safety from tighter pollution laws. Thus, the majority of the diecasting industry would revert to . absorbent as the primary escape source for hydraulic fluids. Separate fluid analyses from the interceptor pits of "sumps" of Johnson Motors, Lester Castings and Central Diecasting are reported in Table II. In all cases the Pydraul was found to be of high purity. In all cases the Pydraul isn't being reclaimed. The pre- sence of large amounts of solids In the Johnson Motors and Lester Castings samples as well as the 30^ non-Pydraul content in the sump of Johnson Motors is felt, to be a direct result of housekeeping. Both the level of solids and the amount of contamination from oil, etc., can be controlled. Milt Tegethoff of Findett has indicated that of all the bulk waste and "sump" Pydraul forwarded to him by our customers over the past several years for reclamation all have been of reclaimable quality. In the few cases where analysis beforehand Indicated unacceptable fluid quality discussions with plant personnel resulted in fluid of reclaimable- quality." It is ' i . * - DSW 297317 STLCOPCB4067227 11 important to note that in cases where the level of solids is high a.solvent extraction technique is required for effective Pydraul recovery. Sol/ent extraction techniques were successfully evaluated by Research on Pydraul-absorbent mixtures. This subject is discussed separately. ;v`.f.v'-V3' .. . DSW 297318 STLCOPCB4067228 V V 4- CO a fi H H co H Z Po 0 u < A w w to E-c n CO W d1 >< * o< A P H O --i H^ H& <' < CO O U M H < r w o CO ." :rw4 *.; ; +OJ CO CcHOl CJ o o u Cl u>* o +J cn Cl 5 o 12 co 001 e mU cn Sb *-c O.H --I noTOi oH tcm* tbJO 2 n8J h 4o-> a id m * O uo p** 6or; mU oa. 0> twu *d3 N. poL, 1 rdd o A 08 . . . N 't Ifi -I (M m OSVM 2973^9 STLCOPCB4067229 13 Steel Industry . Figure^! outlines the operations at Wisconsin Steely Wheeling- Plttsburgh Steel and Timken Steed, where Pydraul is currently being used and where samples were taken of the water and scale pit areas to analyze for Pydraul content and recoverability. The results of these analyses are valuable because each process is different yet typical of high volume Pydraul consumption that comes In direct contact with vater. The processes analyzed were a continuous caster, hot strip mill and two tube mills. In these hot steel operations hydraulic fluid leakages directly contact the cooling water. Oxidized steel solids (scale) settle from the cooling water in the scale or settling pits where residence times were as much as 1-8 hours. Cooling water flow rates through vary from 300-10000 gpm, depending upon operation and.size of plant. Results of the Pydraul analyses from Wisconsin, Wheeling and Timken Steel are reported on Table III. The high Pydraul content in the casting pit and scale pits equals almost the entire reported Pydraul usage at that plant even when using a conservative estimate for the amount of scale produced per day. The overflow' from the pits contains minute quantities of Pydraul. The small amount of fluid and the presence of other chemicals pre cludes economical recovery .using conventional absorptive, filtration techniques. Pydraul in the overflow from the settling areas of DSW 297320 STLCOPCB4067230 these steel companies ranged from less than one gallon per year to about 200 gallons per year at parts per million levels of 1 or less. Although Pydraul levels are too low for recovery, escape is directly to the sewer which opens questions to pollution control. In the case of every steel company contacted during this study (total 6) waste treatment plants were either in existance or planned for the immediate future. All plants follow essentially the same basic approach to treatment which involves: 1) DeemuLsification and flotation of oils. 2) Skimming and concentration of oils both at the scale pit and clarifier areas. Oils arc then pumped to storage and either disposed of or reclaimed. 3) Chemical flocculation and clarification of solids and precipitable salts and acids. '.A) Filtration of precipitated sludges. 5) Disposal of filtered sludges either by incineration, ' lagooning or land fill. The minute quantities' of Pydraul overflowing from the scale pits can thus be expected to end up in the sludge. The growing trend for sludge disposal is incineration due. to restrictions now being placed on land fills and private lagoons. For those operations using FR fluids in direct contact with the cooling water, the descaling area has been identified as the prime ...... .escape source. Economic recovery of the FR fluids from scale would require solvent extraction. This process, although favorable for * 1 DSW 297321 STLCOPCB4067231 15 diecasting appears impractical Tor the steel industry as: 1) Outside contaminates are high and uncontrollable. In the case of Wheeling Steel the ratio of Pydraul to the other products consumed in their 80 inch hot strip mill is about 1:2 Pydraul:kerosene solvent and 1:500 Pydraul: soluble rolling oil. ' -` . ` 2) The growing practice in the steel industry is to sinter dredged scale from the scale pits. The by-product is reused in the steel making process. Sintering temperatures are over 1000F. indicating adhered lydraul is vaporised at the sintering plant. A substantial amount of synthetic fluids are consumed in the steel industry in equipment not in direct contact with water. For example., scrap chargers, increased use of hydraulically operated furnaces, GPS soaking pits fuel-air regulators, etc. Findett customers for reclaimed Pydraul have included Laclede Steel and Wisconsin Steel. It is reasonable and conservative to assume that at least 10-20^ of the consumption from the primary steel producers is reclaimable. Fluid in these cases will come from leakage, spillage and mass line breaks. . V: DSV\J 297322 STLCOPCB4067232 B to C v S P Q W B O Aw Ap A < wco i H 1/3 w B <; B to W W D <J to D P p <; p B P 39 P< a pCO 0 VI 0bO *oMd c3 O 23 o> u rut h Bu ^o o >> O1 ' ,h in cj . co s <oD roH & fio ' o CdO> OH 1 c oo m a O c> 2 rt Xs . in in O p J j-i H wo I--l daS'* a<iu,y* tn o '3 <--CJl 3 H C<-u (J a cj <ti to rt o pCJ *od jO ^ in 3X vi CJ 2ra . * 1--oI B 0> u 4o- * I--< P -(- p o I->op (0 p, J-I P3 QCyO in mg g.-o BP oo P CJ io 2rt 6 a in 1w hJ O^ LBLl. <S CHO-* l-J 4nn STLCOPCB4067233 . - Company Fluid Used . TABLE II ^- 40 SALVAGE FLUID QUALITY-DIECASTING . . , t' ' . Johnson Motors Les;er Castings . Central Diecasting Pydraul A-200 pydraul 312 Pydraul 312 Location-Sample Analy s is- Sample Sump Stream Bed ' Sump . % Solids 70 80 44 % Fluid 30 20 56 Specific Gravity 1.22 . Fluid 1. 41 1.09 . Specific Gravity 1. 42 New Pydraul 1. 42 1.10-1.20 % Pydraul 70% 100% 95-100% Solids Present Absorbent Aluminum Fines Absorbent & Inorganic Absorbent Aluminum Fines Comments on Pydraul Recovery* E . * Solve nt Solvent extraction extraction required. required Solvent extraction required Sump 2 98 1.13 1.10-1. 20 100% Absor bent Aluminum F ines Filtration type only DSW 297324 STLCOPCB4067234 . TABLE III PYDRAUL EFFLUENT ANALYSES STEEL INDUSTRY (see Figure I) 41 Solid/Fluid* Pydraul Ratio PPm b gal/yr %Total Usage Recoverability Wisconsin Steel (1) Caster Pit (2) Settling Basin 3727 2400c 1. 53 0. 2 ~100% nil Difficult-solvent extract N/A (3) Cooling Tower Gve rflow 0. 63 0.1 nil N/A Wheeling Steel (1) Scale (2) Scale Pit ove rflow 155 22 00d 0.1 200 ^90 10-12 Diffi c ul t - r. olve nt extract N/A Timken Steel (1) #3 Tube Mill 0.017 25 0.1 N/A (2) #4 Tube Mill 0.125 200 1 N/A (3) Pond-Top . (4) Pond - bottom 1:50 4:1 (5) Pond-overflow 0.126 nil No evidence of Pydraul-all oil No evidence of Pydraul, all oil. Solvent extraction from solids require a) excluding water b) expressed as PCB content c) at 100 lbs per day scale (solids) throughput c)at 1 ton per day scale (solids) throughput DS\N 297325 i I STLCOPCB4067235